Routine evaluation of BACTEC NR-16A and NR-17A media.

R J Courcol 1, A V Durocher 1, M Roussel-Delvallez 1, A Fruchart 1, G R Martin 1
PMCID: PMC266682  PMID: 3183014

Abstract

The purpose of this study was to determine whether the BACTEC NR-16A and NR-17A media were more effective than the BACTEC NR-6A and NR-7A media in recovering organisms from the blood of patients undergoing antimicrobial therapy. A total of 986 sets of four blood culture bottles were compared, giving 141, 174, 93, and 104 isolates with BACTEC NR-6A, NR-16A, NR-7A, and NR-17A, respectively. BACTEC NR-6A and NR-7A media recovered 234 isolates, whereas BACTEC NR-16A and NR-17A media recovered 278 isolates. The recovery rate of bacteria when aerobic resin media were used was better than that with conventional aerobic media (P less than 0.001). The mean detection times were 51.5 and 69.7 h with NR-16A and NR-6A, respectively (P less than 0.01), whereas they were 68.2 and 71.3 h with NR-17A and NR-7A, respectively (P greater than 0.05). The small number of anaerobes recovered precluded a statistical comparison of relative recovery for that group of organisms.

Full text

PDF
1619

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Appelbaum P. C., Beckwith D. G., Dipersio J. R., Dyke J. W., Salventi J. F., Stone L. L. Enhanced detection of bacteremia with a new BACTEC resin blood culture medium. J Clin Microbiol. 1983 Jan;17(1):48–51. doi: 10.1128/jcm.17.1.48-51.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Courcol R. J., Fruchart A., Roussel-Delvallez M., Martin G. R. Routine evaluation of the nonradiometric BACTEC NR 660 system. J Clin Microbiol. 1986 Jul;24(1):26–29. doi: 10.1128/jcm.24.1.26-29.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. DeGirolami P. C., Eichelberger K., Siegel J. Detection of bacteremia with the BACTEC 16B resin blood culture medium. Am J Clin Pathol. 1984 May;81(5):643–646. doi: 10.1093/ajcp/81.5.643. [DOI] [PubMed] [Google Scholar]
  4. Doern G. V., Gantz N. M. Detection of bacteremia in patients receiving antimicrobial therapy: an evaluation of the antimicrobial removal device and 16B medium. J Clin Microbiol. 1983 Jul;18(1):43–48. doi: 10.1128/jcm.18.1.43-48.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Hopfer R. L., Moore D. G., Fainstein V., Watkins S., Wenglar M. Routine use of BACTEC 16B bottles to remove antibacterial and antitumor agents from blood cultures of cancer patients. J Clin Microbiol. 1983 Oct;18(4):759–764. doi: 10.1128/jcm.18.4.759-764.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Jungkind D., Millan J., Allen S., Dyke J., Hill E. Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system. J Clin Microbiol. 1986 Feb;23(2):262–266. doi: 10.1128/jcm.23.2.262-266.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Lindsey N. J., Riely P. E. In vitro antibiotic removal and bacterial recovery from blood with an antibiotic removal device. J Clin Microbiol. 1981 Mar;13(3):503–507. doi: 10.1128/jcm.13.3.503-507.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. McGuire N. M., Kauffman C. A., Hertz C. S., Kovach J. M. Evaluation of the BACTEC antimicrobial removal system for detection of bacteremia. J Clin Microbiol. 1983 Sep;18(3):449–451. doi: 10.1128/jcm.18.3.449-451.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Rodriguez F., Lorian V. Antibacterial activity in blood cultures. J Clin Microbiol. 1985 Feb;21(2):262–263. doi: 10.1128/jcm.21.2.262-263.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Strand C. L. Evaluation of the antimicrobial removal device when used with the BACTEC blood culture system. Am J Clin Pathol. 1982 Dec;78(6):853–856. doi: 10.1093/ajcp/78.6.853. [DOI] [PubMed] [Google Scholar]
  11. Tegtmeier B. R., Vice J. L. Evaluation of the BACTEC 16B medium in a cancer center. Am J Clin Pathol. 1984 Jun;81(6):783–786. doi: 10.1093/ajcp/81.6.783. [DOI] [PubMed] [Google Scholar]
  12. Wallis C., Melnick J. L., Wende R. D., Riely P. E. Rapid isolation of bacteria from septicemic patients by use of an antimicrobial agent removal device. J Clin Microbiol. 1980 May;11(5):462–464. doi: 10.1128/jcm.11.5.462-464.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Washington J. A., 2nd, Ilstrup D. M. Blood cultures: issues and controversies. Rev Infect Dis. 1986 Sep-Oct;8(5):792–802. doi: 10.1093/clinids/8.5.792. [DOI] [PubMed] [Google Scholar]
  14. Wright A. J., Thompson R. L., McLimans C. A., Wilson W. R., Washington J. A., 2nd The antimicrobial removal device. A microbiological and clinical evaluation. Am J Clin Pathol. 1982 Aug;78(2):173–177. doi: 10.1093/ajcp/78.2.173. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES