Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1989 Nov;27(11):2410–2413. doi: 10.1128/jcm.27.11.2410-2413.1989

Evaluation of microparticle enzyme immunoassays for immunoglobulins G and M to rubella virus and Toxoplasma gondii on the Abbott IMx automated analyzer.

L E Schaefer 1, J W Dyke 1, F D Meglio 1, P R Murray 1, W Crafts 1, A C Niles 1
PMCID: PMC267046  PMID: 2681246

Abstract

The ability of the Abbott IMx automated analyzer to detect immunoglobulin G (IgG) and IgM antibodies to rubella virus and to Toxoplasma gondii was compared with the abilities of RUBAZYME, RUBAZYME-M, ABBOTT TOXO-G enzyme immunoassay, and ABBOTT TOXO-M enzyme immunoassay, respectively. Specimens that produced discordant results were evaluated by RUBACELL II, Behring Enzygnost-Rubella enzyme-linked immunosorbent assay, Behring Enzygnost Toxoplasmosis/IgG, and bioMerieux Toxo-ISAGA (immunosorbent agglutination assay), respectively. After resolution of discordant results, IMx Rubella IgG, IMx Rubella IgM, IMx Toxo IgG, and IMx Toxo IgM antibody assays had sensitivities of 99.9, 100, 98.0, and 100%; specificities of 98.9, 99.0, 97.5, and 98.7%; and accuracies of 99.8, 99.3, 97.8, and 98.8%, respectively.

Full text

PDF
2410

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Chernesky M. A., DeLong D. J., Mahony J. B., Castriciano S. Differences in antibody responses with rapid agglutination tests for the detection of rubella antibodies. J Clin Microbiol. 1986 Apr;23(4):772–776. doi: 10.1128/jcm.23.4.772-776.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Cremer N. E., Hagens S. J., Fukuchi R. Improved serological diagnosis of rubella. J Clin Microbiol. 1983 Sep;18(3):743–744. doi: 10.1128/jcm.18.3.743-744.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Desmonts G., Couvreur J. Congenital toxoplasmosis. A prospective study of 378 pregnancies. N Engl J Med. 1974 May 16;290(20):1110–1116. doi: 10.1056/NEJM197405162902003. [DOI] [PubMed] [Google Scholar]
  4. Echevarria J. M., de Ory F., Najera R. Fluoroimmunoassay for detection of rubella-specific immunoglobulin M: comparison with indirect enzyme immunoassay and mu-chain capture. J Clin Microbiol. 1985 Sep;22(3):428–434. doi: 10.1128/jcm.22.3.428-434.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Enders G., Knotek F. Detection of IgM antibodies against rubella virus: comparison of two indirect ELISAs and an anti-IgM capture immunoassay. J Med Virol. 1986 Aug;19(4):377–386. doi: 10.1002/jmv.1890190410. [DOI] [PubMed] [Google Scholar]
  6. Field P. R., Gong C. M. Diagnosis of postnatally acquired rubella by use of three enzyme-linked immunosorbent assays for specific immunoglobulins G and M and single radial hemolysis for specific immunoglobulin G. J Clin Microbiol. 1984 Nov;20(5):951–958. doi: 10.1128/jcm.20.5.951-958.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Fiore M., Mitchell J., Doan T., Nelson R., Winter G., Grandone C., Zeng K., Haraden R., Smith J., Harris K. The Abbott IMx automated benchtop immunochemistry analyzer system. Clin Chem. 1988 Sep;34(9):1726–1732. [PubMed] [Google Scholar]
  8. Fuccillo D. A., Madden D. L., Tzan N., Sever J. L. Difficulties associated with serological diagnosis of Toxoplasma gondii infections. Diagn Clin Immunol. 1987;5(1):8–13. [PubMed] [Google Scholar]
  9. Hanshaw J. B., Dudgeon J. A. Rubella. Major Probl Clin Pediatr. 1978;17:17–96. [PubMed] [Google Scholar]
  10. Herbrink P., van Loon A. M., Rotmans J. P., van Knapen F., van Dijk W. C. Interlaboratory evaluation of indirect enzyme-linked immunosorbent assay, antibody capture enzyme-linked immunosorbent assay, and immunoblotting for detection of immunoglobulin M antibodies to Toxoplasma gondii. J Clin Microbiol. 1987 Jan;25(1):100–105. doi: 10.1128/jcm.25.1.100-105.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Kalimo K. O., Meurman O. H., Halonen P. E., Ziola B. R., Viljanen M. K., Granfors K., Toivanen P. Solid-phase radioimmunoassay of rubella virus immunoglobulin G and immunoglobulin M antibodies. J Clin Microbiol. 1976 Aug;4(2):117–123. doi: 10.1128/jcm.4.2.117-123.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Lennette E. H., Schmidt N. J., Magoffin R. L. The hemagglutination inhibition test for rubella: a comparison of its sensitivity to that of neutralization, complement fixation and fluorescent antibody tests for diagnosis of infection and determination of immunity status. J Immunol. 1967 Oct;99(4):785–793. [PubMed] [Google Scholar]
  13. Mahony J. B., Castriciano S., Chernesky M. A. Cost and performance analysis of haemagglutination inhibition, passive haemagglutination, radial haemolysis, and enzyme immunoassay for measuring rubella antibody. J Virol Methods. 1987 Nov;18(2-3):133–142. doi: 10.1016/0166-0934(87)90118-2. [DOI] [PubMed] [Google Scholar]
  14. Meurman O. H. Antibody responses in patients with rubella infection determined by passive hemagglutination, hemagglutination inhibition, complement fixation, and solid-phase radioimmunoassay tests. Infect Immun. 1978 Feb;19(2):369–372. doi: 10.1128/iai.19.2.369-372.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Naot Y., Remington J. S. An enzyme-linked immunosorbent assay for detection of IgM antibodies to Toxoplasma gondii: use for diagnosis of acute acquired toxoplasmosis. J Infect Dis. 1980 Nov;142(5):757–766. doi: 10.1093/infdis/142.5.757. [DOI] [PubMed] [Google Scholar]
  16. Safford J. W., Abbott G. G., Deimler C. M. Evaluation of a rapid passive hemagglutination assay for anti-rubella antibody: comparison to hemagglutination inhibition and a vaccine challenge study. J Med Virol. 1985 Nov;17(3):229–236. doi: 10.1002/jmv.1890170304. [DOI] [PubMed] [Google Scholar]
  17. Sever J. L. TORCH tests and what they mean. Am J Obstet Gynecol. 1985 Jul 1;152(5):495–498. doi: 10.1016/0002-9378(85)90614-3. [DOI] [PubMed] [Google Scholar]
  18. Sever J. L., Tzan N. R., Shekarchi I. C., Madden D. L. Rapid latex agglutination test for rubella antibody. J Clin Microbiol. 1983 Jan;17(1):52–54. doi: 10.1128/jcm.17.1.52-54.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Skendzel L. P., Wilcox K. R., Edson D. C. Evaluation of assays for the detection of antibodies to rubella. A report based on data from the College of American Pathologists Surveys of 1982. Am J Clin Pathol. 1983 Oct;80(4 Suppl):594–598. [PubMed] [Google Scholar]
  20. Strannegård O., Grillner L., Lindberg I. M. Hemolysis-in-gel test for the demonstration of antibodies to rubella virus. J Clin Microbiol. 1975 Jun;1(6):491–494. doi: 10.1128/jcm.1.6.491-494.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Violand S. A., Mitchell T. G., Kleeman K. T. Comparison of an enzyme-linked immunoassay and a quantitative indirect fluorescent-antibody test with the conventional indirect fluorescent-antibody test for detecting antibodies to Toxoplasma gondii. J Clin Microbiol. 1982 Aug;16(2):341–344. doi: 10.1128/jcm.16.2.341-344.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Vänänen P., Häivä V. M., Koskela P., Meurman O. Comparison of a simple latex agglutination test with hemolysis-in-gel, hemagglutination inhibition, and radioimmunoassay for detection of rubella virus antibodies. J Clin Microbiol. 1985 May;21(5):793–795. doi: 10.1128/jcm.21.5.793-795.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  23. Walls K. W., Barnhart E. R. Titration of human serum antibodies to Toxoplasma gondii with a simple fluorometric assay. J Clin Microbiol. 1978 Feb;7(2):234–235. doi: 10.1128/jcm.7.2.234-235.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Walton B. C., Benchoff B. M., Brooks W. H. Comparison of the indirect fluorescent antibody test and methylene blue dye test for detection of antibodies to Toxoplasma gondii. Am J Trop Med Hyg. 1966 Mar;15(2):149–152. doi: 10.4269/ajtmh.1966.15.149. [DOI] [PubMed] [Google Scholar]
  25. Wielaard F., van Gruijthuijsen H., Duermeyer W., Joss A. W., Skinner L., Williams H., van Elven E. H. Diagnosis of acute toxoplasmosis by an enzyme immunoassay for specific immunoglobulin m antibodies. J Clin Microbiol. 1983 Jun;17(6):981–987. doi: 10.1128/jcm.17.6.981-987.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Wilson M., Ware D. A., Walls K. W. Evaluation of commercial serodiagnostic kits for toxoplasmosis. J Clin Microbiol. 1987 Dec;25(12):2262–2265. doi: 10.1128/jcm.25.12.2262-2265.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  27. Wittenburg R. A., Roberts M. A., Elliott L. B., Little L. M. Comparative evaluation of commercial rubella virus antibody kits. J Clin Microbiol. 1985 Feb;21(2):161–163. doi: 10.1128/jcm.21.2.161-163.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. van Loon A. M., van der Logt J. T., Heessen F. W., van der Veen J. Enzyme-linked immunosorbent assay that uses labeled antigen for detection of immunoglobulin M and A antibodies in toxoplasmosis: comparison with indirect immunofluorescence and double-sandwich enzyme-linked immunosorbent assay. J Clin Microbiol. 1983 Jun;17(6):997–1004. doi: 10.1128/jcm.17.6.997-1004.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES