Abstract
In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia (M. P. Weinstein, S. Mirrett, and L. B. Reller, J. Clin. Microbiol. 26:962-964, 1988). To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive cultures relative to the BACTEC radiometric system, we agitated all Oxoid bottles during the first 24 to 48 h of incubation and performed aerobic and anaerobic subcultures of all Oxoid bottles negative after 7 days of incubation. These modifications improved the overall performance of the Oxoid system, particularly with regard to the yield of streptococci, members of the family Enterobacteriaceae, and Haemophilus, Neisseria, and Acinetobacter spp. The speed of detecting positive cultures also was improved, especially within the first 24 h of incubation. However, the BACTEC system still detected more positive cultures (P less than 0.005), especially of obligate aerobes such as Pseudomonas aeruginosa (P less than 0.05) and yeasts (P less than 0.005). The BACTEC system also detected positive cultures earlier than the Oxoid system (e.g., at 24 h of incubation, 70.5% of BACTEC positive cultures detected versus 62.1% of Oxoid positive cultures detected). Further modifications of the Oxoid system which might include a revised medium, additional processing modifications, altered headspace atmosphere, or a complementary second broth medium should be considered, since the system is attractive in concept and is easy to use in the clinical laboratory.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Araj G. F., Hopfer R. L., Wenglar M., Fainstein V. Valuable of terminal subcultures from negative BACTEC blood culture bottles. J Clin Microbiol. 1981 Nov;14(5):589–590. doi: 10.1128/jcm.14.5.589-590.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Campbell J., Washington J. A., 2nd Evaluation of the necessity for routine terminal subcultures of previously negative blood cultures. J Clin Microbiol. 1980 Oct;12(4):576–578. doi: 10.1128/jcm.12.4.576-578.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gill V. J. Lack of clinical relevance in routine terminal subculturing of blood cultures. J Clin Microbiol. 1981 Jul;14(1):116–118. doi: 10.1128/jcm.14.1.116-118.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hawkins B. L., Peterson E. M., de la Maza L. M. Improvement of positive blood culture detection by agitation. Diagn Microbiol Infect Dis. 1986 Sep;5(3):207–213. doi: 10.1016/0732-8893(86)90003-9. [DOI] [PubMed] [Google Scholar]
- Kiehn T. E., Wong B., Edwards F. F., Armstrong D. Routine aerobic terminal subculturing of blood cultures in a cancer hospital. J Clin Microbiol. 1983 Oct;18(4):885–889. doi: 10.1128/jcm.18.4.885-889.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kim M. J., Gottschall R. L., Schwabe L. D., Randall E. L. Effect of agitation and frequent subculturing on recovery of aerobic and facultative pathogens by Roche Septi-Chek and BACTEC blood culture systems. J Clin Microbiol. 1987 Feb;25(2):312–315. doi: 10.1128/jcm.25.2.312-315.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Knepper J. G., Anthony B. F. Diminished growth of Pseudomonas aeruginosa in unvented blood-culture bottles. Lancet. 1973 Aug 11;2(7824):285–287. doi: 10.1016/s0140-6736(73)90792-7. [DOI] [PubMed] [Google Scholar]
- Plorde J. J., Carlson L. G., Dau M. E. Lack of clinical relevance in routine final subcultures of radiometrically negative BACTEC blood culture vials. Am J Clin Pathol. 1982 Nov;78(5):753–755. doi: 10.1093/ajcp/78.5.753. [DOI] [PubMed] [Google Scholar]
- Sawhney D., Hinder S., Swaine D., Bridson E. Y. Novel method for detecting micro-organisms in blood cultures. J Clin Pathol. 1986 Nov;39(11):1259–1263. doi: 10.1136/jcp.39.11.1259. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinstein M. P., Mirrett S., Reller L. B. Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia. J Clin Microbiol. 1988 May;26(5):962–964. doi: 10.1128/jcm.26.5.962-964.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinstein M. P., Reller L. B., Murphy J. R., Lichtenstein K. A. The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations. Rev Infect Dis. 1983 Jan-Feb;5(1):35–53. doi: 10.1093/clinids/5.1.35. [DOI] [PubMed] [Google Scholar]