Abstract
We compared a new, rapid, qualitative test for rotavirus (TestPack Rotavirus; Abbott Laboratories, North Chicago, Ill.) with another enzyme immunoassay (Pathfinder Rotavirus; Kallestad Laboratories, Inc., Austin, Tex.) and electron microscopy to determine its clinical utility in a population of symptomatic hospitalized children. In the first part of the study, 100 frozen stool samples were tested. The results after resolution with a blocking reagent showed a sensitivity of only 50% and a specificity of 88% for TestPack Rotavirus. In the second part of the study, we tested TestPack Rotavirus on 100 fresh, unfrozen samples. The results (sensitivity/specificity) were as follows: TestPack Rotavirus, 95/90%; Pathfinder Rotavirus, 84/98%; direct electron microscopy, 63/100%. Although it was not as sensitive or specific as immune electron microscopy, TestPack Rotavirus was more sensitive than direct electron microscopy or Kallestad Pathfinder Rotavirus. TestPack Rotavirus represents a rapid, qualitative method for the detection of rotavirus in stools of symptomatic children.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bishop R. F., Davidson G. P., Holmes I. H., Ruck B. J. Virus particles in epithelial cells of duodenal mucosa from children with acute non-bacterial gastroenteritis. Lancet. 1973 Dec 8;2(7841):1281–1283. doi: 10.1016/s0140-6736(73)92867-5. [DOI] [PubMed] [Google Scholar]
- Brandt C. D., Kim H. W., Rodriguez W. J., Thomas L., Yolken R. H., Arrobio J. O., Kapikian A. Z., Parrott R. H., Chanock R. M. Comparison of direct electron microscopy, immune electron microscopy, and rotavirus enzyme-linked immunosorbent assay for detection of gastroenteritis viruses in children. J Clin Microbiol. 1981 May;13(5):976–981. doi: 10.1128/jcm.13.5.976-981.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chernesky M., Castriciano S., Mahony J., Spiewak M., Schaefer L. Ability of TESTPACK ROTAVIRUS enzyme immunoassay to diagnose rotavirus gastroenteritis. J Clin Microbiol. 1988 Nov;26(11):2459–2461. doi: 10.1128/jcm.26.11.2459-2461.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Doern G. V., Herrmann J. E., Henderson P., Stobbs-Walro D., Perron D. M., Blacklow N. R. Detection of rotavirus with a new polyclonal antibody enzyme immunoassay (Rotazyme II) and a commercial latex agglutination test (Rotalex): comparison with a monoclonal antibody enzyme immunoassay. J Clin Microbiol. 1986 Feb;23(2):226–229. doi: 10.1128/jcm.23.2.226-229.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Eiden J., Sato S., Yolken R. Specificity of dot hybridization assay in the presence of rRNA for detection of rotaviruses in clinical specimens. J Clin Microbiol. 1987 Sep;25(9):1809–1811. doi: 10.1128/jcm.25.9.1809-1811.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gerna G., Sarasini A., Passarani N., Torsellini M., Parea M., Battaglia M. Comparative evaluation of a commercial enzyme-linked immunoassay and solid-phase immune electron microscopy for rotavirus detection in stool specimens. J Clin Microbiol. 1987 Jun;25(6):1137–1139. doi: 10.1128/jcm.25.6.1137-1139.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hammond G. W., Ahluwalia G. S., Hazelton P. R. Detection of human rotaviruses in fecal specimens by a commercial latex-agglutination test. J Infect Dis. 1984 Jun;149(6):1021–1021. doi: 10.1093/infdis/149.6.1021. [DOI] [PubMed] [Google Scholar]
- Kapikian A. Z., Kim H. W., Wyatt R. G., Cline W. L., Arrobio J. O., Brandt C. D., Rodriguez W. J., Sack D. A., Chanock R. M., Parrott R. H. Human reovirus-like agent as the major pathogen associated with "winter" gastroenteritis in hospitalized infants and young children. N Engl J Med. 1976 Apr 29;294(18):965–972. doi: 10.1056/NEJM197604292941801. [DOI] [PubMed] [Google Scholar]
- Knisley C. V., Bednarz-Prashad A. J., Pickering L. K. Detection of rotavirus in stool specimens with monoclonal and polyclonal antibody-based assay systems. J Clin Microbiol. 1986 May;23(5):897–900. doi: 10.1128/jcm.23.5.897-900.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Marchlewicz B., Spiewak M., Lampinen J. Evaluation of Abbott TESTPACK ROTAVIRUS with clinical specimens. J Clin Microbiol. 1988 Nov;26(11):2456–2458. doi: 10.1128/jcm.26.11.2456-2458.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Martin A. L., Follett E. A. An assessment of the sensitivity of three methods for the detection of rotavirus. J Virol Methods. 1987 May;16(1-2):39–44. doi: 10.1016/0166-0934(87)90029-2. [DOI] [PubMed] [Google Scholar]
- Miotti P. G., Eiden J., Yolken R. H. Comparative efficiency of commercial immunoassays for the diagnosis of rotavirus gastroenteritis during the course of infection. J Clin Microbiol. 1985 Nov;22(5):693–698. doi: 10.1128/jcm.22.5.693-698.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nakata S., Petrie B. L., Calomeni E. P., Estes M. K. Electron microscopy procedure influences detection of rotaviruses. J Clin Microbiol. 1987 Oct;25(10):1902–1906. doi: 10.1128/jcm.25.10.1902-1906.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Obert G., Gloeckler R., Burckard J., van Regenmortel M. H. Comparison of immunosorbent electron microscopy, enzyme immunoassay and counterimmunoelectrophoresis for detection of human rotavirus in stools. J Virol Methods. 1981 Sep;3(2):99–107. doi: 10.1016/0166-0934(81)90006-9. [DOI] [PubMed] [Google Scholar]
- Rubenstein A. S., Miller M. F. Comparison of an enzyme immunoassay with electron microscopic procedures for detecting rotavirus. J Clin Microbiol. 1982 May;15(5):938–944. doi: 10.1128/jcm.15.5.938-944.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sanekata T., Yoshida Y., Okada H. Detection of rotavirus in faeces by latex agglutination. J Immunol Methods. 1981;41(3):377–385. doi: 10.1016/0022-1759(81)90199-x. [DOI] [PubMed] [Google Scholar]
- Ushijima H., Kohno H., Kim B., Shinozaki T., Araki K., Fujii R. A new latex agglutination test kit for detecting rotavirus in stool from children with gastroenteritis. Pediatr Infect Dis. 1986 Jul-Aug;5(4):492–493. doi: 10.1097/00006454-198607000-00029. [DOI] [PubMed] [Google Scholar]
- Yolken R. H., Eiden J., Leister F. Self-contained enzymic membrane immunoassay for detection of rotavirus antigen in clinical samples. Lancet. 1986 Dec 6;2(8519):1305–1307. doi: 10.1016/s0140-6736(86)91434-0. [DOI] [PubMed] [Google Scholar]
- Yolken R. H., Stopa P. J. Analysis of nonspecific reactions in enzyme-linked immunosorbent assay testing for human rotavirus. J Clin Microbiol. 1979 Nov;10(5):703–707. doi: 10.1128/jcm.10.5.703-707.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]