Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1989 Jun;27(6):1234–1237. doi: 10.1128/jcm.27.6.1234-1237.1989

Agreement study between two laboratories of immunofluorescence as a confirmatory test for human immunodeficiency virus type 1 antibody screening.

J Mahony 1, K Rosenthal 1, M Chernesky 1, S Castriciano 1, E Scheid 1, M Blajchman 1, D Harnish 1
PMCID: PMC267533  PMID: 2666438

Abstract

A total of 114 serum specimens from 76 blood donors, 21 patients with acquired immune deficiency syndrome or acquired immune deficiency syndrome-related complex, 7 multiply transfused patients, 3 hemophiliacs, and 7 others were tested for anti-human immunodeficiency virus type 1 (HIV-1) antibody by enzyme immunoassay (EIA) and Western blot (WB) and then blindly tested by immunofluorescence (IF), independently, in two separate laboratories. The IF technique used acetone-fixed HIV-1-infected E cells and uninfected HUT-78 cells mixed at a 1:3 ratio in one spot on a glass slide and uninfected HUT-78 cells (to assess nonspecific fluorescence) alone in a second spot. Of 114 serum specimens, 85 were repeat EIA positive, and 21 of these were WB positive. A total of 129 of 134 of the IF results (included were 20 duplicates) were identical between laboratories, for a Kappa agreement statistic of 0.93. All five IF results discordant between laboratories were EIA repeat positive and WB negative. Included in the study were eight WB-indeterminate sera, of which five blood donor serum specimens and one hemophiliac serum specimen were IF negative and two acquired immune deficiency syndrome serum specimens were IF positive. As a confirmatory test for HIV-1 antibodies, IF provided a faster alternative or supplementary test for confirming EIA results.

Full text

PDF
1234

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Aceti A., Titti F., Verani P., Buttò S., Pennica A., Sebastiani A., Rossi G. B. Time-resolved immunofluorescence: a sensitive and specific assay for anti-HIV antibody detection in human sera. J Virol Methods. 1987 Jul;16(4):303–315. doi: 10.1016/0166-0934(87)90015-2. [DOI] [PubMed] [Google Scholar]
  2. Biberfeld G., Bredberg-Rådén U., Böttiger B., Putkonen P. O., Blomberg J., Juto P., Wadell G. Blood donor sera with false-positive Western blot reactions to human immunodeficiency virus. Lancet. 1986 Aug 2;2(8501):289–290. doi: 10.1016/s0140-6736(86)92111-2. [DOI] [PubMed] [Google Scholar]
  3. Blomberg J., Klasse P. J. Specificities and sensitivities of three systems for determination of antibodies to human immunodeficiency virus by electrophoretic immunoblotting. J Clin Microbiol. 1988 Jan;26(1):106–110. doi: 10.1128/jcm.26.1.106-110.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Brun-Vezinet F., Rouzioux C., Barre-Sinoussi F., Klatzmann D., Saimot A. G., Rozenbaum W., Christol D., Gluckmann J. C., Montagnier L., Chermann J. C. Detection of IgG antibodies to lymphadenopathy-associated virus in patients with AIDS or lymphadenopathy syndrome. Lancet. 1984 Jun 9;1(8389):1253–1256. doi: 10.1016/s0140-6736(84)92444-9. [DOI] [PubMed] [Google Scholar]
  5. Burke D. S., Redfield R. R. False-positive Western blot tests for antibodies to HTLV-III. JAMA. 1986 Jul 18;256(3):347–347. [PubMed] [Google Scholar]
  6. Burke D. S., Redfield R. R., Putman P., Alexander S. S. Variations in Western blot banding patterns of human T-cell lymphotropic virus type III/lymphadenopathy-associated virus. J Clin Microbiol. 1987 Jan;25(1):81–84. doi: 10.1128/jcm.25.1.81-84.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Cooper D. A., Imrie A. A., Penny R. Antibody response to human immunodeficiency virus after primary infection. J Infect Dis. 1987 Jun;155(6):1113–1118. doi: 10.1093/infdis/155.6.1113. [DOI] [PubMed] [Google Scholar]
  8. Gallo D., Diggs J. L., Shell G. R., Dailey P. J., Hoffman M. N., Riggs J. L. Comparison of detection of antibody to the acquired immune deficiency syndrome virus by enzyme immunoassay, immunofluorescence, and Western blot methods. J Clin Microbiol. 1986 Jun;23(6):1049–1051. doi: 10.1128/jcm.23.6.1049-1051.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Joller-Jemelka H. I., Joller P. W., Müller F., Schüpbach J., Grob P. J. Anti-HIV IgM antibody analysis during early manifestations of HIV infections. AIDS. 1987 May;1(1):45–47. [PubMed] [Google Scholar]
  10. Kaminsky L. S., McHugh T., Stites D., Volberding P., Henle G., Henle W., Levy J. A. High prevalence of antibodies to acquired immune deficiency syndrome (AIDS)-associated retrovirus (ARV) in AIDS and related conditions but not in other disease states. Proc Natl Acad Sci U S A. 1985 Aug;82(16):5535–5539. doi: 10.1073/pnas.82.16.5535. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Karpas A., Gillson W., Bevan P. C., Oates J. K. Lytic infection by British AIDS virus and development of rapid cell test for antiviral antibodies. Lancet. 1985 Sep 28;2(8457):695–697. doi: 10.1016/s0140-6736(85)92934-4. [DOI] [PubMed] [Google Scholar]
  12. Kenealy W., Reed D., Cybulski R., Tribe D., Taylor P., Stevens C., Matthews T., Petteway S. Analysis of human serum antibodies to human immunodeficiency virus (HIV) using recombinant ENV and GAG antigens. AIDS Res Hum Retroviruses. 1987 Spring;3(1):95–105. doi: 10.1089/aid.1987.3.95. [DOI] [PubMed] [Google Scholar]
  13. Lennette E. T., Karpatkin S., Levy J. A. Indirect immunofluorescence assay for antibodies to human immunodeficiency virus. J Clin Microbiol. 1987 Feb;25(2):199–202. doi: 10.1128/jcm.25.2.199-202.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Meyer K. B., Pauker S. G. Screening for HIV: can we afford the false positive rate? N Engl J Med. 1987 Jul 23;317(4):238–241. doi: 10.1056/NEJM198707233170410. [DOI] [PubMed] [Google Scholar]
  15. Prince A. M., Pascual D., Kosolapov L. B., Kurokawa D., Baker L., Rubinstein P. Prevalence, clinical significance, and strain specificity of neutralizing antibody to the human immunodeficiency virus. J Infect Dis. 1987 Aug;156(2):268–272. doi: 10.1093/infdis/156.2.268. [DOI] [PubMed] [Google Scholar]
  16. Quinn T. C., Riggin C. H., Kline R. L., Francis H., Mulanga K., Sension M. G., Fauci A. S. Rapid latex agglutination assay using recombinant envelope polypeptide for the detection of antibody to the HIV. JAMA. 1988 Jul 22;260(4):510–513. [PubMed] [Google Scholar]
  17. Rey F., Barré-Sinoussi F., Schmidtmayerova H., Chermann J. C. Detection and titration of neutralizing antibodies to HIV using an inhibition of the cytopathic effect of the virus on MT4 cells. J Virol Methods. 1987 Jun;16(3):239–249. doi: 10.1016/0166-0934(87)90008-5. [DOI] [PubMed] [Google Scholar]
  18. Riggin C. H., Beltz G. A., Hung C. H., Thorn R. M., Marciani D. J. Detection of antibodies to human immunodeficiency virus by latex agglutination with recombinant antigen. J Clin Microbiol. 1987 Sep;25(9):1772–1773. doi: 10.1128/jcm.25.9.1772-1773.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Robert-Guroff M., Brown M., Gallo R. C. HTLV-III-neutralizing antibodies in patients with AIDS and AIDS-related complex. Nature. 1985 Jul 4;316(6023):72–74. doi: 10.1038/316072a0. [DOI] [PubMed] [Google Scholar]
  20. Robertson G. A., Kostek B. M., Schleif W. A., Lewis J. A., Emini E. A. A microtiter cell-culture assay for the determination of anti-human immunodeficiency virus neutralizing antibody activity. J Virol Methods. 1988 Jul;20(3):195–202. doi: 10.1016/0166-0934(88)90123-1. [DOI] [PubMed] [Google Scholar]
  21. Roy S., Portnoy J., Wainberg M. A. Need for caution in interpretation of Western Blot tests for HIV. JAMA. 1987 Feb 27;257(8):1047–1047. [PubMed] [Google Scholar]
  22. Saag M. S., Britz J. Asymptomatic blood donor with a false positive HTLV-III Western blot. N Engl J Med. 1986 Jan 9;314(2):118–118. doi: 10.1056/nejm198601093140212. [DOI] [PubMed] [Google Scholar]
  23. Saah A. J., Farzadegan H., Fox R., Nishanian P., Rinaldo C. R., Jr, Phair J. P., Fahey J. L., Lee T. H., Polk B. F. Detection of early antibodies in human immunodeficiency virus infection by enzyme-linked immunosorbent assay, Western blot, and radioimmunoprecipitation. J Clin Microbiol. 1987 Sep;25(9):1605–1610. doi: 10.1128/jcm.25.9.1605-1610.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Sandstrom E. G., Schooley R. T., Ho D. D., Byington R., Sarngadharan M. G., MacLane M. E., Essex M., Gallo R. C., Hirsch M. S. Detection of human anti-HTLV-III antibodies by indirect immunofluorescence using fixed cells. Transfusion. 1985 Jul-Aug;25(4):308–312. doi: 10.1046/j.1537-2995.1985.25485273806.x. [DOI] [PubMed] [Google Scholar]
  25. Sarngadharan M. G., Popovic M., Bruch L., Schüpbach J., Gallo R. C. Antibodies reactive with human T-lymphotropic retroviruses (HTLV-III) in the serum of patients with AIDS. Science. 1984 May 4;224(4648):506–508. doi: 10.1126/science.6324345. [DOI] [PubMed] [Google Scholar]
  26. Smith R. S., Naso R. B., Rosen J., Whalley A., Hom Y. L., Hoey K., Kennedy C. J., McCutchan J. A., Spector S. A., Richman D. D. Antibody to a synthetic oligopeptide in subjects at risk for human immunodeficiency virus infection. J Clin Microbiol. 1987 Aug;25(8):1498–1504. doi: 10.1128/jcm.25.8.1498-1504.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  27. Thorpe R., Brasher M. D., Bird C. R., Garrett A. J., Jacobs J. P., Minor P. D., Schild G. C. An improved immunoblotting procedure for the detection of antibodies against HIV. J Virol Methods. 1987 May;16(1-2):87–96. doi: 10.1016/0166-0934(87)90034-6. [DOI] [PubMed] [Google Scholar]
  28. Tribe D. E., Reed D. L., Lindell P., Kenealy W. R., Ferguson B. Q., Cybulski R., Winslow D., Waselefsky D. M., Petteway S. R., Jr Antibodies reactive with human immunodeficiency virus gag-coded antigens (gag reactive only) are a major cause of enzyme-linked immunosorbent assay reactivity in a blood donor population. J Clin Microbiol. 1988 Apr;26(4):641–647. doi: 10.1128/jcm.26.4.641-647.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
  29. Vercauteren G., van der Groen G., Piot P. Comparison of enzyme immunoassays and an immunofluorescence test for detection of antibody to human immunodeficiency virus in African sera. Eur J Clin Microbiol. 1987 Apr;6(2):132–135. doi: 10.1007/BF02018193. [DOI] [PubMed] [Google Scholar]
  30. Yoshida T., Matsui T., Kobayashi S., Yamamoto N. Evaluation of passive particle agglutination test for antibody to human immunodeficiency virus. J Clin Microbiol. 1987 Aug;25(8):1433–1437. doi: 10.1128/jcm.25.8.1433-1437.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. van der Groen G., Vercauteren G., Piot P. Immunofluorescence tests for HIV antibody and their value as confirmatory tests. J Virol Methods. 1987 Aug;17(1-2):35–43. doi: 10.1016/0166-0934(87)90066-8. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES