Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1990 Apr;28(4):808–810. doi: 10.1128/jcm.28.4.808-810.1990

Evaluation of enzyme-linked immunoassay systems for detection of human immunodeficiency virus type 1 antibody from filter paper disks impregnated with whole blood.

J L Beebe 1, L C Briggs 1
PMCID: PMC267803  PMID: 2332474

Abstract

Five commercial enzyme-linked immunoassay systems for the detection of human immunodeficiency virus type 1 antibody from filter paper disks impregnated with whole blood were evaluated for technical and operational performance. All five systems performed adequately in the technical challenges posed, with specificities in excess of 99% for 1,020 specimens. In a serial dilution sensitivity challenge, all of the kits were able to detect specific antibody within one dilution of a Western blot (immunoblot) standard, except for a Du Pont Co. kit, which detected antibody within two dilutions of the standard. The Du Pont assay showed the least variation in control values between test runs and between lots. All of the systems produced acceptable results, but their operational parameters differed significantly.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Courouce A. M. Evaluation of eight ELISA kits for the detection of anti-LAV/HTLV-III antibodies. Lancet. 1986 May 17;1(8490):1152–1153. doi: 10.1016/s0140-6736(86)91863-5. [DOI] [PubMed] [Google Scholar]
  2. Gaines H., von Sydow M., Sönnerborg A., Albert J., Czajkowski J., Pehrson P. O., Chiodi F., Moberg L., Fenyö E. M., Asjö B. Antibody response in primary human immunodeficiency virus infection. Lancet. 1987 May 30;1(8544):1249–1253. doi: 10.1016/s0140-6736(87)92696-1. [DOI] [PubMed] [Google Scholar]
  3. Guinan M. E., Hardy A. Epidemiology of AIDS in women in the United States. 1981 through 1986. JAMA. 1987 Apr 17;257(15):2039–2042. [PubMed] [Google Scholar]
  4. Gürtler L. G., Eberle J., Lorbeer B., Deinhardt F. Sensitivity and specificity of commercial ELISA kits for screening anti-LAV/HTLV III. J Virol Methods. 1987 Jan;15(1):11–23. doi: 10.1016/0166-0934(87)90044-9. [DOI] [PubMed] [Google Scholar]
  5. Hoff R., Berardi V. P., Weiblen B. J., Mahoney-Trout L., Mitchell M. L., Grady G. F. Seroprevalence of human immunodeficiency virus among childbearing women. Estimation by testing samples of blood from newborns. N Engl J Med. 1988 Mar 3;318(9):525–530. doi: 10.1056/NEJM198803033180901. [DOI] [PubMed] [Google Scholar]
  6. Lindhardt B. O., Bygbjerg I. C., Ulrich K., Petersen H. D., Lausen I., Frederiksen B. Detection of antibodies to human immunodeficiency virus (HIV) in eluates from whole blood impregnated filter paper discs. J Virol Methods. 1987 Oct;18(1):73–77. doi: 10.1016/0166-0934(87)90112-1. [DOI] [PubMed] [Google Scholar]
  7. Marlink R. G., Allan J. S., McLane M. F., Essex M., Anderson K. C., Groopman J. E. Low sensitivity of ELISA testing in early HIV infection. N Engl J Med. 1986 Dec 11;315(24):1549–1549. doi: 10.1056/NEJM198612113152413. [DOI] [PubMed] [Google Scholar]
  8. Mortimer P. P., Parry J. V., Mortimer J. Y. Which anti-HTLV III/LAV assays for screening and confirmatory testing? Lancet. 1985 Oct 19;2(8460):873–877. doi: 10.1016/s0140-6736(85)90136-9. [DOI] [PubMed] [Google Scholar]
  9. Reesink H. W., Lelie P. N., Huisman J. G., Schaasberg W., Gonsalves M., Aaij C., Winkel I. N., van der Does J. A., Hekker A. C., Desmyter J. Evaluation of six enzyme immunoassays for antibody against human immunodeficiency virus. Lancet. 1986 Aug 30;2(8505):483–486. doi: 10.1016/s0140-6736(86)90358-2. [DOI] [PubMed] [Google Scholar]
  10. Saah A. J., Farzadegan H., Fox R., Nishanian P., Rinaldo C. R., Jr, Phair J. P., Fahey J. L., Lee T. H., Polk B. F. Detection of early antibodies in human immunodeficiency virus infection by enzyme-linked immunosorbent assay, Western blot, and radioimmunoprecipitation. J Clin Microbiol. 1987 Sep;25(9):1605–1610. doi: 10.1128/jcm.25.9.1605-1610.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Stute R. Comparison in sensitivity of 10 HIV antibody detection tests by serial dilutions of Western blot-confirmed samples. J Virol Methods. 1988 Jul;20(3):269–274. doi: 10.1016/0166-0934(88)90130-9. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES