Abstract
Direct acoustic stimulation of the cochlea by the sound-pressure difference between the oval and round windows (called the “acoustic route”) has been thought to contribute to hearing in some pathological conditions, along with the normally dominant “ossicular route.” To determine the efficacy of this acoustic route and its constituent mechanisms in human ears, sound pressures were measured at three locations in cadaveric temporal bones [with intact and perforated tympanic membranes (TMs)]: (1) in the external ear canal lateral to the TM, PTM; (2) in the tympanic cavity lateral to the oval window, POW; and (3) near the round window, PRW. Sound transmission via the acoustic route is described by two concatenated processes: (1) coupling of sound pressure from ear canal to middle-ear cavity, HPCAV≡PCAV/PTM, where PCAV represents the middle-ear cavity pressure, and (2) sound-pressure difference between the windows, HWPD≡(POW−PRW)/PCAV. Results show that: HPCAV depends on perforation size but not perforation location; HWPD depends on neither perforation size nor location. The results (1) provide a description of the window pressures based on measurements, (2) refute the common otological view that TM perforation location affects the “relative phase of the pressures at the oval and round windows,” and (3) show with an intact ossicular chain that acoustic-route transmission is substantially below ossicular-route transmission except for low frequencies with large perforations. Thus, hearing loss from TM perforations results primarily from reduction in sound coupling via the ossicular route. Some features of the frequency dependence of HPCAV and HWPD can be interpreted in terms of a structure-based lumped-element acoustic model of the perforation and middle-ear cavities.
I. INTRODUCTION
Because the cochlea responds to the pressure difference between the oval and round windows (Voss et al., 1996), it is useful to understand how these “window pressures” are generated in both normal and pathological ears. In normal ears, the net window pressure difference is dominated by the sound pressure delivered to the oval window via the ossicular system, a mechanism referred to as the “ossicular route” by Peake et al. (1992). Via the ossicular route, a cochlear window-pressure difference is generated by motion of the tympanic membrane (TM), malleus, incus, and stapes driven by the pressure difference across the TM. In addition to driving the ossicular system, TM motion generates a sound-pressure field in the middle-ear cavity, which for most of the audio frequency range is approximately uniform throughout the cavity (e.g., Lynch, 1981; Voss, 1998). Thus, the sound pressures at the adjacent oval and round windows, POW and PRW, are nearly equal; the relatively small pressure difference ΔPwin=POW−PRW adds to the ossicular-route stimulus to the cochlea. Consistent with Peake et al. (1992), we refer to the mechanism that drives the cochlea through ΔPwin as the “acoustic route” (Fig. 1).
In a normal ear the contribution of the acoustic route is insignificant compared to the ossicular route, but the acoustic route can become important when ossicular transmission is decreased (Békésy, 1947; Schmitt, 1958; Peake et al., 1992; Merchant et al., 1997a). Perforation of the TM decreases ossicular-route transmission and purportedly increases acoustic-route transmission. The primary goals of this work are: (1) To describe the acoustic-route transmission systematically and the effect of TM perforations on it; (2) To assess the characteristics of the mechanisms involved in the acoustic route; and (3) To identify conditions in which the acoustic route plays a significant role in hearing.
The effect of TM perforations on the acoustic route has been discussed in the literature, but no systematic measurements have been reported. Békésy (1947) reported measurements of the pressure difference between the oval and round windows at six frequencies in one temporal-bone preparation without a TM. In Peake et al. (1992) these measurements are used with a middle-ear model to predict hearing loss with a total perforation (i.e., TM removed). The model predicts that with the elimination of ossicular coupling, the acoustic route provides hearing levels of 40–60 dB, from 250 to 3000 Hz, consistent with clinically observed hearing loss.
With TM perforations, a popular idea is that a perforation’s location in the TM affects the sound pressures at the oval and round windows. Schmitt (1958) introduced the idea that differences in both the magnitude and phase angles of the sound pressures at the two windows are important. Sub-sequently, a view developed that a perforation directly lateral to the round window affects the pressures acting on the oval and round windows differently from a perforation at other (e.g., more anterior) locations (e.g., Pickles, 1987; pp. 60, 61; Glasscock and Shambaugh, 1990, p. 314; Schuknecht, 1993, p. 196). Specifically, this view assumes that the sound pressure at the round window “cancels” the pressure at the oval window more with posterior-inferior perforations than with perforations at other locations.
Recent work that describes total middle-ear sound transmission in the presence of TM perforations includes: (1) Input impedance and ossicular-motion measurements from temporal-bone preparations with controlled, experimentally produced TM perforations (Voss et al., 2001b); (2) An analog-circuit model that describes mathematically the effects of TM perforations on total middle-ear sound transmission (Voss et al., 2001c); (3) Clinical measurements that are consistent with the temporal-bone experimental and theoretical work (Mehta et al., 2006). Collectively, this work describes and explains hearing loss resulting from a TM perforation as:
Frequency dependent with the largest loss occurring at the lowest frequencies
Increasing with perforation size
Depending on the volume of the middle-ear and mastoid air space with larger losses in ears with smaller volumes
Not varying significantly with location of the perforation in the TM
Here we present measurements [from the same preparations reported in Voss et al. (2001b, c)] of sound pressures outside the cochlear windows and describe how these pressures influence sound transmission in the presence of TM perforations. These measurements and analyses place constraints on sound transmission with perforations. Specifically, the importance of the acoustic route relative to the ossicular route is quantified, and the acoustic route’s dependences on perforation location, size, and sound frequency are determined.
II. ANALYTICAL APPROACH
To describe sound transmission via the acoustic route, we follow the approach of Békésy (1947) and define the effective acoustic-route (AR) transfer function HAR as the ratio of the pressure difference between the oval and round windows to the pressure in the external ear canal at the TM
(1) |
where POW is the pressure within the middle-ear cavity adjacent to the oval window, PRW is the pressure within the middle ear adjacent to the round window, and PTM is the pressure within the ear canal adjacent to the TM. In order to represent the acoustic mechanisms involved (with TM perforations ), we express HAR in terms of two factors: the middle-ear-cavity-pressure transfer function HPCAV and the window-pressure-difference transfer function HWPD,
(2) |
where PCAV is the sound pressure within the middle-ear air space. Note that in general PCAV depends on location in the middle-ear cavity; we address this dependence below. The first factor, HPCAV, is a measure of the acoustic processes that couple sound pressure in the ear canal to the middle-ear cavity; the second factor, HWPD, is determined by the acoustic processes that produce spatial variations within the cavity. In the absence of a detailed model for the acoustic processes, it is conceivable that HPCAV and HWPD depend on both location and size of perforations and on frequency.
III. METHODS
A. Transfer function calculations
We use measurements of the oval- and round-window pressures, POW and PRW, and the ear-canal pressure PEC transformed to pressure at the TM PTM (Voss et al., 2001b), to calculate the factors of the acoustic route. The middle-ear-cavity-pressure transfer function, HPCAV, is calculated from our pressure measurements as
(3) |
where we assume that the cavity pressure PCAV is nearly uniform throughout the cavity and therefore can be approximated in this ratio by the pressure measured near the oval window, POW (or equally well by PRW). The approximation PCAV≈POW is reasonable for frequencies for which the dimensions of the middle-ear cavity are much smaller than the wavelength of sound; i.e., up to about 4000 Hz, where the wavelength (≈9 cm) is about ten times the largest cavity dimension. An experimental test of this simplification showed that even near a TM perforation the pressure within the middle-ear cavity is nearly constant in space (Voss, 1998, Fig. 2–Fig 7, p. 69).
The window-pressure-difference transfer function HWPD is computed from measurements as
(4) |
The acoustic-route transfer function HAR (Eq. (2)) is the product of the factors HPCAV and HWPD
(5) |
B. Experimental overview
Acoustic measurements of middle-ear cavity pressures at the oval and round windows and lateral to the tympanic membrane (TM) were made in cadaveric temporal bones with both intact and perforated TMs. The prepared bones were 11 of the ears for which intact TM results are presented in Voss et al. (2000) and for which stapes velocity and impedance at the TM were measured with perforations (Voss et al., 2001a), (b); most of the measurement techniques are described in detail in Voss et al. (2000, 2001a, b). Additional methods are described here.
Measurements were made on fresh temporal bones for which no evidence of otologic disease was found either in medical records or in oto-microscopic examination. In each case, the bony ear canal was drilled away to expose the TM, and a brass ring was cemented to the bony rim around the TM to allow repeatable coupling and uncoupling of the sound source and calibrated microphone to the ear. Two calibrated probe microphones were introduced into the middle-ear cavity with one probe-tube tip adjacent to the oval window and the other to the round window. In each ear, perforations of different sizes and locations were made with an otosurgical Argon laser, as described by Voss et al. (2001a, b); generally, a small perforation was made and then perforations of increasing size were centered at the same location [see Fig. 1 of Voss et al. (2001b)]. The ear-canal pressure PEC was measured about 3 mm from the TM and these measurements were transformed to approximate the pressure at the TM PTM by modeling the remaining bony ear canal as a uniform cylindrical tube (Voss et al., 2001b, p. 1434).
In these preparations, measurements were also made of stapes velocity and acoustic impedance (Voss et al. 2000, 2001a, b, c); some of these results will be useful here in interpretation of the acoustic mechanisms.
C. Measurement of the oval- and round-window pressures
1. Placement of the oval- and round-window probe-tube microphones in the temporal-bone preparation
Probe-tube microphones sensed the sound pressure outside each cochlear window. In each case, the probe-tube microphone consisted of a Knowles hearing aid microphone coupled to a 33-mm-long steel tube with an inner diameter of 0.8 mm and an outer diameter of 1.1 mm; the distal open end of each probe tube was positioned near the appropriate cochlear window. Each probe microphone was attached to the temporal bone as follows. First, a guide tube (inner diameter 1.2 mm), through which the probe tube could slide, was carefully positioned and glued to the temporal bone. The guide tube provided a straight, repeatable path for the probe tube to reach its window. Next, under the view of a dissecting microscope, the open end of the probe tube was inserted through the guide tube until it was as close as possible to its window (0.5–2 mm). Finally, with the position of the probe tube set within the guide tube, a rubber “o-ring” around the probe tube was positioned to “stop” the probe at the proximal end of the guide tube so that the probe tube was held at this location. This arrangement made it convenient to remove the probe-tube microphone assemblies for repeated calibrations throughout an experiment. The distal openings of the probe tubes were at the posterior-most edge of the footplate (oval window) and lateral to the round window.
2. Calibration of the probe-tube microphones
Each probe-tube microphone (one for measurements at the round window and one for measurements at the oval window) was calibrated by coupling it to the sound source and calibrated microphone assembly that was used to generate and measure sound stimuli in the ear canal (Voss et al., 2000); we refer to this calibrated microphone as the “ear-canal microphone” and the calibration procedure to determine the microphone sensitivity in terms of microphone voltage per sound pressure sensed is described in detail by Voss et al. (2000). Each of the two window probe-tube microphones was calibrated relative to the calibrated ear-canal microphone. Together, the tip of each probe-tube microphone was placed within 1 mm of the calibrated ear-canal microphone within a short cylindrical cavity (Voss et al., 2000). Sound stimuli were generated within the cavity and the sound pressure was assumed equal at the ear-canal microphone and the orifice of the probe-tube microphone; the simultaneous responses of each probe-tube microphone and the calibrated ear-canal microphone were used to determine the sensitivity of each probe-tube microphone. This procedure was followed to determine the calibrations for both microphones—specifically—the transfer functions , which represent the ratios of sound pressure at the oval and round windows to the oval-window and round-window probe-microphone output voltages, respectively.
3. Do the probe-tube microphones measure the pressures at the probe tips?
As the microphones were coupled to the windows via 33-mm-long probe tubes, it is possible that they could sense sound from locations other than the probe tip. To test this possibility, with the microphone coupled to the temporal bone, we measured the microphone output with the probe tube open and also with the window end of the probe tube plugged with cotton. For most frequencies, the output with the probe tube open was at least 40 dB greater (and always at least 20 dB greater) than with the probe tube plugged with cotton (Voss, 1998, Fig. 3-2, p. 112). We concluded that the microphones’ outputs are determined by the sound pressure at the probe-tube tip.
4. Errors in relative calibration between the oval- and round-window microphones
The absolute calibration of the oval- and round-window microphones is not critical for our interest in the window-pressure differences, but consistency in the relative calibrations between the oval- and round-window microphones is crucial in determining precisely the pressure difference between the windows
(6) |
As |PRW/POW|≈1, changes in the relative sensitivity of the microphone pair , which produce small changes in the inferred POW and PRW, may have big effects on the inferred pressure difference. However, small changes that are common to the calibration ratios for both microphones will have equally small effects on the pressure difference; these changes are “divided out” in the ratio PRW/POW and contribute only a small percentage to POW in Eq. (6) (Voss, 1995).
To detect small changes in the relative calibration (e.g., from moisture in a probe tube), the calibration procedure (Sec. III C 2) was repeated several times during each experiment. We use variation in the relative calibration , over repeated measurements, to estimate the range of error in the measurement of PRW/POW.
The process of coupling the probe microphones to the sound-source assembly used for calibrations seemed to be the major source of variability in the calibration. When a probe-tube microphone was attached to the sound-source assembly and left undisturbed, repeated measurements made over several hours showed changes that were less than 0.05 dB in magnitude and 0.001 cycles in angle. In contrast, when the sound-source assembly was moved, and the coupler that attached it to a probe tube was removed and then replaced, the changes in the measured absolute calibrations increased to about 1 dB in magnitude. However, the relative calibration of the two microphones was more stable as it was possible to calibrate both probe-tube microphones, one at a time, without moving the sound source or coupler. Thus, while the absolute calibration of the two microphones changed by 1 dB from calibration to calibration, the relative calibration between the two microphones varied less.
Repeated calibrations among the 11 experiments had different levels of variability. In three of the 11 experiments (bones 23, 22 Right, and 8), the relative calibrations of the oval- and round-window microphones varied by more than 1 dB in magnitude and 0.01 cycles in angle. We considered this level of uncertainty in the calibrations unacceptable for computation of the window-pressure difference (Sec. III C 5). However, in the remaining eight experiments, the relative calibrations of the oval- and round-window microphones varied up to only 0.25 dB1 in magnitude and 0.005 cycles in angle. Thus, we focus our attention on the results from the subset of eight bones with smaller variability in the ratio between the oval- and round-window microphone calibrations. In one of the eight bones (bone 18), there was a dramatic change (2–3 dB) in the round-window microphone calibration midway through the experiment. It is not clear what happened to the microphone; measurements made after the change are not included here.
5. Inaccuracies in the calculations of PRW/POW, HWPD, and HAR
Changes in the relative calibration between the microphones limit the accuracy of calculations of HAR and HWPD. In this section, we estimate limits for accurate calculation of these quantities, based on our estimate of ranges of ±0.25 dB in magnitude and ±0.005 cycles in angle.
First consider how a variation of ±0.25 dB in magnitude and ±0.005 cycles in angle affects the ratio PRW/POW when PRW≈POW. A 0.25 dB change in magnitude in either POW or PRW corresponds to a factor of 1.03. Thus, if the pressures are equal (i.e., PRW=POW), the measurement of the magnitude |PRW/POW| could range from 0.97 to 1.03, and the angle measurement could range from −0.005 to 0.005 cycles when the actual angle ∠(PRW/POW)=0. Next, consider how a relative variation of ±0.25 dB in magnitude and ±0.005 cycles in angle affects the measured HWPD=(1−PRW/POW) (Eq. (4)), when PRW=POW. With PRW/POW=1.03∠0.005, |HWPD| is 0.04 instead of zero. Small errors in magnitude can introduce variation in the angle ∠(HWPD) of ±0.5 cycles because the calculation of HWPD depends on a difference that can have a negative or positive sign depending on the relative values of |PRW| and |POW|; thus, we have chosen to ignore ∠(HWPD) because of possibly large errors.
Finally, consider how the relative changes of ±0.25 dB and ±0.005 cycles in PRW and POW affect the acoustic-route transfer function HAR. If we assume that measurement errors in the ratio POW/PTM (i.e., HPCAV) are negligible, then (from Eq. (5)), errors in |HAR| are equal to errors in |HWPD| multiplied by the factor |POW/PTM|. Thus, when the calculated |HAR|∠0.04|POW/PTM|, HAR may be strongly influenced by relative microphone calibration changes. We define a boundary at |HAR|=0.04|POW/PTM| and refer to this as the “edge of inaccuracy in the measurement of |HAR|.” As discussed above in relation to ∠(HWPD), when |HAR| ∠0.04|POW/PTM| our measurements of angle ∠HAR contain uncertainties of up to ±0.5 cycles.
Table I summarizes the uncertainties and their influence on our ability to measure the quantities PRW/POW, HWPD and HAR. In the results that follow, we plot all of our magnitude measurements, but we indicate the edge of inaccuracy based on Table I.
Table I.
Calculated quantity | Measurement uncertainty or edge of inaccuracy |
---|---|
|PRW/POW| | Uncertainty ±0.03 |
∠ |PRW/POW| | Uncertainty ±0.005 cycles |
|HWPD| | Edge of inaccuracy: 0.04 |
|HWPD| | Uncertainty ±0.50 cycles |
|HAR| | Edge of inaccuracy: 0.04 |
∠HAR | Uncertainty ±0.50 cycles |
D. Statistical tests to compare two groups of data
We use a statistical test to determine the significance of differences between different populations within our data. Specifically, to test the null hypothesis that two means are from the same population, we compute the probability (p) that a given pair of means could differ by as much as the data show, given the null hypothesis. In particular, we test to determine the p values associated with the means for |PRW/POW|, ∠(PRW/POW), |HWPD|, and |HAR| when there are (1) different sized perforations and (2) perforations at different TM locations.
Since the sample sizes used to compute the means are small (range N=2 to N=16), we compute the corresponding p values using a bootstrap permutation test (Efron and Tibshirani, 1993); this method makes no assumption about the probability distribution. The probability that the two means are equal depends on the fraction of the permutations in which the difference between the means of the two permutated test populations are greater than or equal to the difference between the actual means. Further details of our application of this permutation test can be found in Voss (1998).
IV. RESULTS
A. Organization
Each of three sections presents results from our measurements of sound transmission via the acoustic route: (1) the middle-ear-cavity transfer function HPCAV =POW/PTM; (2) the ratio between the oval- and round-window pressures PRW/POW and the window-pressure-difference transfer function magnitude |HWPD|= |1−PRW/POW|; (3) the acousticroute transfer function HAR=| (POW−PRW)/PTM|. For each of these the effects of both perforation size and location are examined. In general, we present results from one of our preparations (bone 24L) as an example and mean measurements across all preparations when appropriate. [Results from each preparation are in Voss (1998).]
B. Middle-ear-cavity-pressure transfer function: HPCAV
1. HPCAV measurements with an intact tympanic membrane
Measured middle-ear-cavity-pressure transfer functions are presented in Fig. 2 with TM perforation sizes varying from zero (intact) to total (TM removed) for the example bone (24L) and for mean measurements from 11 ears. Both the individual measurements (on bone 24L) and the mean measurements are representative of all measurements of HPCAV on the 11 preparations.
With the TM intact, at low frequencies (i.e., ∠1000 Hz) |HPCAV| is roughly independent of frequency at about −10±1 dB on bone 24L (Fig. 2) and across the 11 preparations ranges from −6.6 to −21.1 dB at 488 Hz (mean −12.7 dB and standard deviation 4.8 dB). In the 1000–3000 Hz range, |HPCAV| has a sharp minimum: across the 11 preparations this magnitude minimum ranges from −20.5 to −39.2 dB (mean −30.5 dB and standard deviation 6 dB) and the frequency of the minimum ranges from 928 to 2686 Hz (mean 2151 Hz and standard deviation 531 Hz). In some preparations, at a lower frequency, a peak in magnitude occurs such as that near 800 Hz in Fig. 2 (upper, left); in other preparations there is no peak in this region. In all preparations, there is a sharp maximum in |HPCAV| at a frequency above the sharp minimum described above; across the 11 preparations this maximum occurs between 2612 and 4785 Hz (mean 3650 Hz and standard deviation 564 Hz) and has a value that ranges from −10.3 to −0.8 dB (mean −4.5 dB and standard deviation 2.7 dB).
The angle ∠HPCAV is about zero at the lowest frequencies (∠200 Hz) with the TM intact,2 indicating that the cavity and ear-canal pressures are in phase. As frequency increases toward the frequency of the minimum in |HPCAV|, ∠HPCAV decreases so that the middle-ear cavity pressure lags the ear-canal pressure by up to 0.3 cycles. At the frequency of the sharp minimum in |HPCAV|, ∠HPCAV increases rapidly toward a value between 0 and 0.1 cycles. As frequency increases further, ∠HPCAV decreases rapidly in the 3000–4000 Hz range of the local maximum in |HPCAV|.
In summary, with the TM intact, for frequencies from 100 to 5000 Hz, HPCAV shows behavior consistent with a system with at least two resonances, represented by a midfrequency sharp minimum in magnitude and a higher frequency sharp maximum in magnitude.
2. HPCAV with a tympanic-membrane perforation
In additional to the plots in Fig. 2, the features described here of HPCAV with a perforated TM are summarized in Table II for all 11 preparations and all perforation sizes. At the lowest frequencies HPCAV (with a TM perforation) is approximately one (i.e., magnitude=0 dB and angle=0) (Fig. 2); physically, the perforation acts as an acoustic short circuit between the ear canal and middle-ear cavity, making the pressures equal. As frequency increases above 300 Hz, |HPCAV| peaks above 0 dB (i.e., the middle-ear cavity pressure is greater than the ear-canal pressure); the frequency of this peak increases systematically with perforation diameter. Above the frequency of the peak, |HPCAV| has a sharp minimum (near 2000 Hz); the frequency of this minimum appears to be the same as seen with the TM intact, independent of perforation diameter; |HPCAV| at the minimum increases with perforation size increases. At higher frequencies, the location of the sharp maximum in |HPCAV| that occurs with the TM intact increases somewhat in frequency and magnitude with increasing perforation diameter.
Table II.
Middle-ear cavity transfer function HPCAV (f ,d) Measures of salient features | |||||||||
---|---|---|---|---|---|---|---|---|---|
Preparation |
|HPCAV| Max 0.5–2.8 kHz |
|HPCAV| Min 0.8–3.2 kHz |
|HPCAV| Max >2.5 kHz |
∠HPCAV0.2–2.7 kHz |
|ZTM| Min 0.5–3.0 kHz |
||||
Bone No. | Perf. Diam. (mm) | Mag. (dB) | fmax (kHz) | Mag. (dB) | fmin(kHz) | Mag. (dB) | fmax (kHz) | lowest f for ∠=−0.03 (kHz) | fmin (kHz) |
8 | Intact | DNE | DNE | −39.2 | 2.39 | −6.0 | 4.79 | DNE | 0.98 |
0.5 | −1.5 | 1.00 | −34.0 | 2.32 | −2.5 | 5.37 | DNE | 1.03 | |
0.7 | 1.8 | 1.05 | −30.3 | 2.39 | 0.2 | 4.93 | 0.37 | 1.07 | |
1.1 | 7.40 | 1.12 | −28.9 | 2.39 | 5.3 | 5.96 | 0.59 | 1.17 | |
1.6 | 8.5 | 1.27 | −23.2 | 2.39 | 9.4 | 6.15 | 0.66 | 1.34 | |
2.4 | 9.8 | 1.39 | −21.7 | 2.39 | 11.4 | 6.54 | 0.76 | 1.44 | |
3.2 | 12.3 | 1.56 | −21.9 | 2.37 | 11.7 | 7.28 | 0.98 | 1.61 | |
Removed | 10.3 | 2.00 | −15.5 | 2.47 | 11.1 | 8.33 | 1.10 | 1.96 | |
9 | Intact | DNE | DNE | −26.1 | 0.93 | −0.8 | 2.61 | DNE | 0.98 |
0.1 | DNE | DNE | −23.5 | 0.85 | 0.2 | 2.56 | DNE | 0.93 | |
1.1 | 6.3 | 0.54 | −17.4 | 0.81 | 7.2 | 2.91 | 0.39 | 0.56 | |
1.9 | 6.3 | 0.71 | −11.9 | 0.93 | 7.1 | 3.39 | 0.59 | 0.73 | |
3.3 | 4.4 | 0.90 | −7.7 | 1.17 | 4.5 | 4.00 | 0.76 | 0.98 | |
Removed | DNE | DNE | −0.2 | 1.00 | 1.4 | 4.32 | DNE | 0.98 | |
13 | Intact | DNE | DNE | −34.4 | 1.37 | −2.0 | 3.44 | DNE | 1.86 |
0.5 | DNE | DNE | −28.5 | 1.32 | −3.0 | 3.44 | DNE | 0.73 | |
0.8 | 6.9 | 0.61 | −24.0 | 1.37 | −1.7 | 3.56 | 0.39 | 0.73 | |
1.4 | 7.9 | 0.76 | −23.4 | 1.25 | 3.7 | 3.59 | 0.56 | 0.81 | |
1.8 | 9.3 | 0.90 | −21.1 | 1.29 | 3.7 | 3.98 | 0.71 | 0.98 | |
Removed | 3.2 | 1.27 | −3.2 | 1.49 | DNE | DNE | 1.22 | 1.37 | |
18 | Intact | DNE | DNE | −35.4 | 2.44 | −10.3 | 3.22 | DNE | NA |
0.4 | DNE | DNE | −25.4 | 2.25 | −7.2 | 3.17 | DNE | NA | |
0.5 | 3.6 | 0.59 | −22.1 | 2.25 | −3.6 | 3.20 | 0.24 | NA | |
1.0 | 7.8 | 0.88 | −16.6 | 2.22 | 0.0 | 3.37 | 0.59 | NA | |
1.7 | 6.6 | 1.10 | −15.3 | 2.22 | 7.5 | 3.59 | 0.81 | NA | |
2.3 | 5.8 | 1.20 | −9.4 | 2.29 | 8.0 | 3.71 | 0.93 | NA | |
3.0 | 5.1 | 1.34 | −7.0 | 2.37 | 10.3 | 4.00 | 1.15 | NA | |
Removed | 4.2 | 2.12 | 0.0 | 2.69 | 16.3 | 4.98 | 2.00 | NA | |
19 | Intact | DNE | DNE | −25.8 | 2.10 | −4.1 | 3.44 | DNE | 2.49 |
0.6 | 4.5 | 0.85 | −16.2 | 2.25 | 1.0 | 3.76 | 0.59 | 0.88 | |
1.3 | 6.4 | 1.07 | −12.2 | 1.95 | 5.5 | 3.96 | 0.83 | 1.10 | |
1.9 | 5.6 | 1.34 | −10.2 | 1.98 | 7.9 | 4.15 | 1.00 | 1.42 | |
2.6 | 6.2 | 1.44 | −8.2 | 2.03 | 10.8 | 4.44 | 1.12 | 1.46 | |
Removed | 4.7 | 1.76 | −2.8 | 2.29 | 31.2 | 6.01 | 1.73 | 1.98 | |
20 | Intact | DNE | DNE | −28.2 | 2.15 | −3.7 | 4.08 | DNE | 1.90 |
0.7 | 4.6 | 0.71 | −19.6 | 2.10 | 2.9 | 4.27 | 0.46 | 0.81 | |
0.7 | 4.4 | 0.66 | −19.1 | 2.10 | 2.7 | 4.22 | 0.42 | 0.73 | |
1.0 | 5.4 | 0.83 | −13.2 | 2.69 | 4.4 | 4.37 | 0.63 | 0.85 | |
1.7 | 5.5 | 1.17 | −9.9 | 2.59 | 8.2 | 4.71 | 0.90 | 1.59 | |
3.0 | 6.3 | 1.56 | −8.1 | 2.64 | 12.6 | 5.42 | 1.15 | 1.61 | |
4.0 | 5.5 | 1.64 | −6.4 | 2.61 | 17.2 | 5.93 | 1.29 | 1.73 | |
5.0 | 4.2 | 1.64 | −5.9 | 2.66 | 20.0 | 6.13 | 1.37 | 1.81 | |
Removed | 2.6 | 2.27 | −2.2 | 2.66 | 29.5 | 7.47 | 2.22 | 2.22 | |
22L | Intact | DNE | DNE | −20.5 | 2.32 | −2.8 | 3.59 | DNE | 2.29 |
0.6 | 1.3 | 0.93 | −17.5 | 2.15 | 1.7 | 3.74 | 0.24 | 0.93 | |
1.2 | 5.4 | 1.05 | −15.3 | 2.20 | 5.6 | 4.03 | 0.61 | 1.10 | |
2.0 | 7.1 | 1.37 | −10.8 | 2.34 | 7.5 | 4.25 | 1.17 | 1.59 | |
3.3 | 7.8 | 1.71 | −7.9 | 2.39 | 8.7 | 4.61 | 1.44 | 1.81 | |
5.0 | 7.0 | 1.86 | −5.1 | 2.39 | 11.2 | 5.35 | 1.73 | 1.98 | |
Removed | 4.5 | 2.12 | −3.0 | 2.61 | 9.9 | 5.91 | 2.03 | 2.20 | |
22R | Intact | DNE | DNE | −29.0 | 2.69 | −5.8 | 3.66 | DNE | 1.76 |
0.6 | 0.9 | 1.27 | −25.5 | 2.69 | −1.0 | 3.76 | 0.37 | 1.27 | |
1.3 | 7.7 | 1.46 | −22.7 | 2.69 | 6.8 | 4.03 | 0.76 | 1.47 | |
2.3 | 11.8 | 1.68 | −18.4 | 2.69 | 11.4 | 4.37 | 1.34 | 1.76 | |
3.3 | 12.1 | 1.95 | −14.4 | 2.69 | 15.1 | 4.96 | 1.73 | 2.03 | |
6.8 | 8.6 | 2.20 | −9.8 | 2.81 | Noisy | Noisy | 2.10 | 2.37 | |
Removed | 2.4 | 2.20 | −4.7 | 2.83 | Noisy | Noisy | 1.15 | 2.37 | |
23 | Intact | DNE | DNE | −29.0 | 2.69 | −5.1 | 3.59 | DNE | 1.88 |
0.8 | DNE | DNE | −25.5 | 2.69 | −0.4 | 3.71 | 0.29 | 1.71 | |
1.0 | 2.6 | 1.51 | −22.7 | 2.69 | 1.6 | 3.83 | 0.56 | 1.73 | |
2.0 | 8.6 | 1.83 | −18.4 | 2.69 | 6.1 | 4.03 | 0.98 | 1.86 | |
3.0 | 10.3 | 2.03 | −14.4 | 2.69 | 7.5 | 4.27 | 1.44 | 2.03 | |
4.0 | 10.4 | 2.20 | −9.8 | 2.81 | 7.8 | 4.54 | 1.73 | 2.15 | |
5.0 | 5.7 | 2.37 | −4.7 | 2.83 | Noisy | Noisy | 2.27 | 2.54 | |
Removed | DNE | DNE | −2.3 | 3.15 | Noisy | Noisy | DNE | 2.81 | |
24L | Intact | DNE | DNE | −25.7 | 2.37 | −6.4 | 3.49 | DNE | 1.86 |
0.5 | 0.6 | 0.88 | −21.3 | 2.37 | −2.5 | 3.52 | 0.27 | 0.95 | |
0.8 | 3.3 | 1.00 | −15.8 | 2.39 | −2.0 | 3.83 | 0.46 | 1.03 | |
1.2 | 6.7 | 1.25 | −14.2 | 2.42 | 2.0 | 4.10 | 0.78 | 1.29 | |
2.0 | 6.1 | 1.64 | −9.3 | 2.42 | 5.4 | 4.47 | 1.20 | 1.59 | |
3.3 | 4.1 | 1.83 | −6.7 | 2.49 | 10.6 | 4.98 | 1.44 | 1.98 | |
5.0 | 2.7 | 1.96 | −4.3 | 2.47 | 15.5 | 6.18 | 1.89 | 1.98 | |
Removed | 1.1 | 2.17 | −1.7 | 2.64 | 22.3 | 7.67 | DNE | 2.10 | |
24R | Intact | DNE | DNE | −32.8 | 2.54 | −2.2 | 4.22 | DNE | 2.88 |
0.5 | 2.6 | 0.73 | −30.7 | 2.61 | 0.3 | 4.22 | 0.37 | 0.83 | |
0.6 | 2.3 | 0.73 | −27.7 | 2.61 | 2.0 | 4.13 | 0.37 | 0.78 | |
1.3 | 5.5 | 1.44 | −19.5 | 2.54 | 7.2 | 4.56 | 0.98 | 1.54 | |
2.3 | 8.5 | 1.81 | −14.0 | 2.61 | 10.9 | 5.20 | 1.71 | 1.81 | |
4.0 | 10.0 | 2.10 | −11.3 | 2.61 | 11.0 | 5.79 | 1.73 | 2.10 | |
5.0 | 8.7 | 2.25 | −7.1 | 2.61 | 15.0 | 6.37 | 1.98 | 2.22 | |
Removed | 4.1 | 2.79 | −1.3 | 2.49 | 21.9 | 8.03 | 2.71 | 2.61 |
The angle ∠HPCAV (with the TM perforated) is near zero at the lowest frequencies. As frequency increases, ∠HPCAV decreases; the frequency at which the angle decrease begins increases as perforation diameter increases. For both the intact and perforated conditions, ∠HPCAV increases rapidly at the frequency for which |HPCAV| is a minimum, and ∠HPCAV again decreases rapidly near the frequency of the local maximum in |HPCAV|.
In summary, perforations have dramatic effects on the middle-ear-cavity transfer function HPCAV and increase its magnitude relative to the intact case. For the lowest frequencies, all perforation sizes used equalize the ear-canal and middle-ear-cavity pressures so that HPCAV≈1. Perforations introduce a resonance at which the cavity pressure magnitude exceeds the ear-canal pressure magnitude by up to 10 dB; the resulting local maximum in |HPCAV| occurs between 0.5 and 2.8 kHz, and in each preparation the frequency of the maximum increases as perforation diameter increases. A minimum in |HPCAV| occurs above the frequency of this first peak (in the 1000–3000 Hz range); the frequency of the minimum for each preparation appears to be independent of the TM condition (i.e., intact, various perforation sizes, or TM removed), and the minimum |HPCAV| increases with increasing perforation diameter. A second peak occurs at a frequency above the frequency of this minimum, and the frequency of this peak increases with increasing perforation diameter. These trends occur in each preparation (Table II).
3. Effects of perforation location on HPCAV
To test for effects of perforation location on HPCAV, we measured HPCAV in two preparations [discussed in Voss et al. (2001a) (bones 20, 24 Right)], in each of which measurements were made with a perforation at either of two locations. Voss et al. (2001a) demonstrated that patching small perforations (diameter less than 1 mm) with cigarette paper (moistened with saline) returns the middle-ear response (stapes velocity) to that with an intact TM, thus allowing comparison of responses with one perforation size at different locations.
Figure 3 compares the effects of perforations at two locations on HPCAV for these two cases. In each case, the difference in HPCAV (magnitude and angle) between the two perforation locations is small compared to the large variation with frequency; thus, HPCAV appears to be independent of a perforation’s location for the comparisons (a) marginal versus central (Fig. 3, left column) and (b) anterior-inferior versus posterior-inferior (Fig. 3, right column). The slight differences in HPCAV in the two locations could result from small differences in the perforation size or changes in HPCAV from intact to patched TM. These results extend the conclusion of Voss et al. (2001a) that the effects of a TM perforation on the middle-ear’s response to sound do not depend on the perforation’s location in the TM.
C. Window-pressure-difference transfer function: HWPD
Measurements of the pressure ratio PRW/POW and the calculated transfer function HWPD=1−PRW/POW were analyzed for the subset of eight ears in which the probe-tube microphone calibrations were least variable (Sec. III C 4). Figure 4 plots PRW/POW and |HWPD|= |1−PRW/POW| from one preparation (bone 24L); these plots are representative of the results from the other seven bones, as described below. Mean results across ears are not displayed, as inter-ear differences in the frequencies of magnitude maxima and minima result in means that are not representative of the shape of individual measurements; instead, features of these transfer functions in the eight preparations are presented in Table III.
Table III.
Measures of salient features related to HWPD | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Preparation | (max) | (max) | (min) | |HWPD| (max) | |ZCAV| | ||||||
Bone No. | Perf. Diam. (mm) | Mag. | fmax (kHz) | Angle (cycles) | f_max(kHz) | Mag. | fmin(kHz) | Mag. | fmax(kHz) | fZmax (kHz) | fZmin (kHz) |
9 | Intact | NA | NA | NA | NA | NA | NA | NA | NA | 2.08 | 0.98 |
0.1 | 1.1 | 0.95 | 0.02 | 0.83 | 1.0 | 0.78 | 0.2 | 0.85 | |||
1.1 | 1.1 | 0.85 | 0.03 | 0.81 | 0.9 | 0.71 | 0.2 | 0.81 | |||
1.9 | 1.2 | 0.95 | 0.05 | 0.90 | 0.9 | 0.85 | 0.3 | 0.90 | |||
3.3 | 1.1 | 1.20 | 0.04 | 1.12 | 0.9 | 1.03 | 0.2 | 1.12 | |||
13 | Intact | 1.4 | 1.29 | 0.10 | 1.37 | 0.8 | 1.29 | 0.7 | 1.42 | 2.67 | 1.32 |
0.5 | 1.3 | 1.15 | 0.06 | 1.32 | 0.9 | 1.15 | 0.4 | 1.39 | |||
0.8 | 1.7 | 1.27 | 0.12 | 1.39 | 0.8 | 1.27 | 0.9 | 1.46 | |||
1.4 | 1.7 | 1.12 | 0.14 | 1.20 | 0.7 | 1.12 | 1.1 | 1.25 | |||
1.8 | 1.9 | 1.17 | 0.17 | 1.27 | 0.6 | 1.17 | 1.3 | 1.29 | |||
Removed | 1.3 | 1.32 | 0.07 | 1.42 | 0.8 | 1.32 | 0.5 | 1.44 | |||
18 | Intact | 1.4 | 2.49 | 0.09 | 2.42 | 0.79 | 2.29 | 0.6 | 2.44 | NA | NA |
0.4 | 1.3 | 2.44 | 0.06 | 2.22 | 0.86 | 2.05 | 0.4 | 2.32 | |||
0.5 | 1.4 | 2.37 | 0.07 | 2.20 | 0.84 | 2.05 | 0.5 | 2.27 | |||
1.0 | 1.3 | 2.42 | 0.07 | 2.17 | 0.80 | 2.03 | 0.4 | 2.25 | |||
19 | Intact | 1.2 | 2.7 | 0.05 | 2.08 | 0.9 | 1.90 | 0.28 | 2.12 | 2.93 | 1.98 |
0.6 | 1.3 | 2.4 | 0.05 | 1.98 | 0.9 | 1.61 | 0.30 | 2.37 | |||
1.3 | 1.2 | 2.4 | 0.06 | 1.90 | 0.9 | 1.66 | 0.42 | 1.93 | |||
1.9 | 1.2 | 2.4 | 0.07 | 1.88 | 0.9 | 1.66 | 0.43 | 1.93 | |||
2.6 | 1.2 | 2.4 | 0.07 | 1.88 | 0.9 | 1.64 | 0.45 | 1.93 | |||
Removed | 1.2 | 2.4 | 0.04 | 2.05 | 0.9 | 1.90 | 0.25 | 2.03 | |||
20 | Intact | 1.1 | 2.34 | 0.01 | 2.12 | 0.9 | 2.05 | 0.1 | 2.08 | 3.66 | 2.22 |
0.7 | 1.1 | 2.42 | 0.02 | 2.05 | 0.9 | 2.00 | 0.2 | 2.03 | |||
0.7 | 1.1 | 3.00 | 0.02 | 2.05 | 0.9 | 1.95 | 0.1 | 2.00 | |||
1.0 | 1.1 | 2.95 | 0.03 | 2.61 | 0.9 | 1.90 | 0.2 | 2.61 | |||
1.7 | 1.1 | 2.95 | 0.03 | 2.56 | 0.9 | 1.86 | 0.2 | 2.56 | |||
3.0 | 1.1 | 2.95 | 0.04 | 2.54 | 0.9 | 1.86 | 0.3 | 2.56 | |||
4.0 | 1.1 | 2.93 | 0.04 | 2.54 | 0.9 | 1.83 | 0.3 | 2.56 | |||
5.0 | 1.1 | 2.95 | 0.04 | 2.54 | 0.9 | 2.00 | 0.3 | 2.56 | |||
Removed | 1.1 | 2.95 | 0.04 | 2.54 | 1.0 | 2.05 | 0.3 | 2.54 | |||
22L | Intact | 1.5 | 2.44 | 0.08 | 2.29 | 0.8 | 2.10 | 0.7 | 2.37 | 3.37 | 2.20 |
0.6 | 1.4 | 2.44 | 0.04 | 2.27 | 0.8 | 2.05 | 0.4 | 2.42 | |||
1.2 | 1.7 | 2.42 | 0.09 | 2.25 | 0.7 | 2.05 | 0.8 | 2.37 | |||
2.0 | 1.7 | 2.44 | 0.09 | 2.29 | 0.8 | 2.03 | 0.9 | 2.39 | |||
3.3 | 1.7 | 2.44 | 0.09 | 2.32 | 0.8 | 2.00 | 0.9 | 2.42 | |||
5.0 | 1.7 | 2.44 | 0.09 | 2.29 | 0.8 | 1.95 | 0.9 | 2.39 | |||
Removed | 1.6 | 2.44 | 0.07 | 2.34 | 0.8 | 1.93 | 0.7 | 2.42 | |||
24L | Intact | 1.2 | 2.47 | 0.08 | 2.37 | 0.7 | 2.22 | 0.5 | 2.39 | 2.98 | 2.10 |
0.5 | 1.5 | 2.44 | 0.07 | 2.34 | 0.8 | 2.10 | 0.6 | 2.42 | |||
0.8 | 1.4 | 2.49 | 0.05 | 2.42 | 0.8 | 2.00 | 0.5 | 2.49 | |||
1.2 | 1.5 | 2.49 | 0.07 | 2.39 | 0.9 | 2.03 | 0.7 | 2.47 | |||
2.0 | 1.5 | 2.49 | 0.07 | 2.42 | 0.8 | 1.83 | 0.6 | 2.47 | |||
3.3 | 1.4 | 2.51 | 0.07 | 2.44 | 0.8 | 2.00 | 0.6 | 2.49 | |||
5.0 | 1.6 | 2.47 | 0.06 | 2.37 | 0.8 | 1.93 | 0.8 | 2.44 | |||
Removed | 1.4 | 2.49 | 0.05 | 2.49 | 0.8 | 1.88 | 0.5 | 2.49 | |||
24R | Intact | 2.0 | 2.83 | 0.23 | 2.73 | 0.3 | 2.69 | 1.5 | 2.78 | 4.00 | 2.61 |
0.5 | 1.9 | 2.81 | 0.36 | 2.71 | 0.5 | 2.64 | 2.2 | 2.76 | |||
0.6 | 1.7 | 2.76 | 0.18 | 2.64 | 0.8 | 1.93 | 1.4 | 2.71 | |||
1.3 | 1.8 | 2.93 | 0.37 | 2.71 | 0.1 | 2.76 | 1.2 | 2.67 | |||
2.3 | 1.8 | 2.93 | 0.35 | 2.69 | 0.6 | 2.76 | 1.6 | 2.66 | |||
4.0 | 1.9 | 2.93 | 0.43 | 2.71 | 0.1 | 2.73 | 1.2 | 2.64 | |||
5.0 | 1.8 | 2.93 | 0.34 | 2.69 | 0.0 | 2.71 | 1.1 | 2.93 | |||
Removed | 1.5 | 2.93 | 0.38 | 2.69 | 0.1 | 2.73 | 1.1 | 2.69 |
1. Frequency dependence
In all eight preparations, at the lower frequencies (i.e., less than 1000 Hz), the magnitude |PRW/POW|≈1 and the angle ∠(PRW/POW)≈0, indicating that PRW≈POW; these features appear for both the intact TM cases and all perforation sizes, and are apparent in the example bone 24L in Fig. 4 (left). Above 1000 Hz, a frequency region exists where |PRW/POW| exhibits a minimum with a magnitude less than 1 and at a higher frequency a maximum with a magnitude greater than 1; for example, in bone 24L with an intact TM, the magnitude minimum is about 0.7 at 2200 Hz and the magnitude maximum is about 1.2 at 2500 Hz (Fig. 4, left). In the frequency range of these extrema there is a sharp increase in ∠(PRW/POW) to a peak and a steep decrease to near 0 cycles; in bone 24L, the peak in angle is about 0.08 cycles at about 2400 Hz. These features in data for bone 24L occur across all preparations. In each ear, for all TM conditions, between about 1000 and 3000 Hz, the ratio exhibits a local magnitude minimum adjacent to a local magnitude maximum, with an increase and decrease in angle. Although this pattern is seen in all ears, there are inter-ear variations in size and frequency of peaks (Table III).
Although at most frequencies PRW and POW are roughly equal, between 1000 and 3000 Hz |PRW| and |POW| have large derivatives with respect to frequency, and the biggest differences between PRW and POW occur at the frequencies where |PRW| and |POW| change rapidly (i.e., near 2500 Hz). All measurements show that in the frequency region of steep change a decrease in |PRW| occurs in a slightly lower frequency range than the decrease in |POW|. This “frequency shift” produces the pattern of the local minimum in the pressure ratio |PRW/POW| at a frequency just below a local maximum in |PRW/POW|. The consistency of this behavior suggests that the dominant mechanism(s) is the same in all preparations. Possibilities for this mechanism(s) are proposed in Sec. V C.
In Sec. III C 4 we suggest that errors in the measurements of the oval- and round-window pressures lead to uncertainties of ±0.25 dB in magnitude and ±0.005 cycles in angle for the calculation of PRW/POW. The corresponding “uncertainty ranges” of ±0.03 in magnitude (assuming PRW ≈POW) and ±0.005 cycles in angle are indicated by a bracket in each plot of Fig. 4 (left). At a given frequency, measurements that are within the span of this bar may not represent a real difference. Therefore, differences between perforation conditions that are smaller than a factor of 0.06 in magnitude and 0.01 cycles in angle are considered not detectably different. Most of the measurements of magnitudes and angles of PRW/POW are within the uncertainty estimate, so the small differences with perforation size may not reflect real differences. Measurements outside this uncertainty estimate, such as those from bone 24L between 1000 and 3000 Hz for all perforation sizes, are presumed to be significant.
Next, we consider the window-pressure-difference transfer function HWPD (Fig. 4, right). This transfer function is simply related to the pressure ratio: HWPD=1−(PRW/POW). Thus, when PRW/POW≈1, the magnitude |HWPD|≪1 and the angle ∠HWPD can be very sensitive to small changes in magnitude.
Most of the |HWPD| results increase with frequency above 800 Hz to a local maximum between 1000 and 3000 Hz. This local maximum is a consequence of the local maximum of the pressure ratio |PRW/POW|. However, below 800 Hz, 0.97≤ |PRW/POW|≤1.03, such that |HWPD|<0.04, and we cannot reliably determine |HWPD|.
2. Effects of perforation size on |HWPD|
For a given frequency below 1000 Hz, variations in bone 24L (Fig. 4) and the other seven preparations (Voss, 1998, page 251) do not seem to be systematically related to perforation size. The variability may result from small errors in our pressure measurements when POW≈PRW, as the estimate of the lower limit for which we can accurately measure |HWPD| is 0.04 (Sec. III C 4), which is indicated on the plot in Fig. 4 (right). Our calculations of |HWPD| below about 1000 Hz are in the “region of uncertainty.” Data in this region are shown because their coherence across measurements in this region indicates that the main trends may be representative even at levels below |HWPD|=0.04.
To compare results across ears and perforation size we systematically sort PRW/POW and HWPD results into seven groups differing in TM condition (defined in the legend of Fig. 2), and we compute the means within each of the seven groups for the three quantities |PRW/POW|, ∠(PRW/POW) and |HWPD|. To determine if the differences between these means are significant, at each of six frequencies (125, 250, 500, 1000, 2000, and 4000 Hz) we use the “resampling-permutation” methodology described in Sec. III D to compute p values for differences between each group’s mean relative to all other measurements.
Tests between all combinations of seven TM conditions at six frequencies and for three quantities yield a total of 378 p values, which are all reported in Voss (1998). Almost all of the computed p values for all three quantities (|PRW/POW| ,∠(PRW/POW), |HWPD|) are such that p≫0.05, indicating that the differences between the means are not significant. There are comparisons for which p<0.05, but these do not suggest any trends with perforation size. For example, there are four comparisons (of a total of 126 comparisons) for |PRW/POW| for which p<0.05; two of these occur at 125 Hz and the other two at 250 Hz, both frequencies where the uncertainties limit the measurements. Similarly, occasional values where p<0.05 occur in the calculations for ∠(PRW/POW) at the lower frequencies. However, there are no cases where p<0.05 for |HWPD|. Thus, in general, we conclude that our results for |PRW/POW|, ∠(PRW/POW), and |HWPD| do not demonstrate dependence on perforation size for any frequency range.
3. Effects of perforation location on HWPD
We compare the effects of perforation location (i.e., anterior-inferior versus posterior-inferior) on the quantities |PRW/POW|, ∠(PRW/POW), and |HWPD| in a similar manner to our comparison of perforation size (Sec. IV C 2). First, we form three perforation-size categories: (1) 0.1≤ d≤1 mm; (2) 1<d≤2 mm; and (3) 2<d≤4 mm. Next, within each size category, means are computed separately (at six frequencies ) for |PRW/POW|, ∠(PRW/POW), and |HWPD| from perforations in the anterior-inferior quadrant and posterior-inferior quadrant. These means are then tested to determine if the differences between the two locations are significant.
The resulting p values for the perforation-location dependence of |PRW/POW|, ∠(PRW/POW), and |HWPD| do not show systematic dependences of HWPD on perforation location. For 51 of the 54, p>0.05; the remaining three comparisons, where p<0.05, do not suggest any trends. For example, for the diameter range 1<d≤2 mm, there is a possible location dependence for ∠(PRW/POW) between anterior and posterior perforations for the frequencies 500 and 1000 Hz. However, this dependence is not seen for smaller or larger perforations at these frequencies. In general, the results do not indicate a perforation-location dependence of any of the three quantities |PRW/POW|, ∠(PRW/POW), and |HWPD|.
D. Effects of tympanic-membrane perforations on net sound transmission via the acoustic route: |HAR|
1. Measurements of |HAR|
The acoustic-route transfer function |HAR| is plotted in Fig. 5 for the example bone (24L) [and in Voss (1998) for all eight bones]. The lower plots in Fig. 5 (corresponding to the TM intact, removed, and with six perforation sizes) show that, below 1000 Hz, the measurements of |HAR| are often in the “region of uncertainty,” which is based on relative errors in the measurement of POW and PRW. Thus, some of these low-frequency measurements of |HAR| are likely to be influenced by measurement errors.
2. Effect of perforation size on |HAR|
Figure 5 shows two general trends that occur across the preparations with perforation size as a parameter. First, with an intact TM |HAR| is generally less than |HAR| with a perforation; the increase in |HAR| with a perforation is a consequence of the perforation-induced increase in |HPCAV| as seen in Fig. 2. Second, for frequencies above about 1000 Hz, the perforation size influences |HAR| in a manner similar to |HPCAV| (see Fig. 2): at most frequencies, |HAR| increases with perforation size, with the largest increase associated with the change from less than 1 mm to more than 1 mm in perforation diameter. These trends are apparent in the means of all |HAR| measurements, grouped by perforation size (Fig. 6).
We performed a probabilistic analysis to determine whether the differences between the means of the seven different groups plotted in Fig. 6 are significant. Using the “resampling-permutation” methodology (Sec. III D), we computed null-hypothesis probabilities p for each |HAR| mean measurement relative to the six other mean measurements. The resulting probabilities that test for significance of differences in the means of |HAR| are summarized here. Generally, the results are consistent with the qualitative impression given by Fig. 6. In particular, the differences between |HAR| with an intact TM and |HAR| with a TM perforation of any size are highly significant (p≪0.05) for nearly all perforation sizes at nearly all tested frequencies. At frequencies below 1000 Hz, there are no significant differences (p <0.05) between perforations of different sizes; either there are no true differences or our analysis is limited by inaccuracy in measuring the small pressure difference at these lower frequencies. Above 1000 Hz, there is evidence of significant differences in |HAR| between the larger and smaller perforations: for example, at 2000 Hz there are significant differences between 15 of the 16 comparisons for size categories up to 3 mm diameters. There are not systematic trends at the other tested frequencies (1000 and 4000 Hz), and comparisons at 2000 Hz are not significant for comparisons among size pairs for which both are greater than 3 mm in diameter.
3. Effect of perforation location on |HAR|
We compare the effects of perforation location on the |HAR| in a similar manner to our comparison of perforation size performed above for PRW/POW and HWPD (Section IV C 2). Again, we compare perforations in the anterior-inferior quadrant to those in the posterior-inferior quadrant. First, we form three perforation-size categories: (1) 0.1≤d ≤1 mm; (2) 1<d≤2 mm; and (3) 2<d≤4 mm. All perforations such that 0.1≤d≤4 mm are placed into the appropriate category. Next, within each size category, means are computed separately for |HAR| from perforations in the anterior-inferior quadrant and posterior-inferior quadrant. These means are then tested to determine if their differences are significant. There is no evidence of any perforation-location dependence for |HAR|, as for all tests p>0.20.
V. DISCUSSION
A. Summary of measurements and their limitations
We have represented the acoustic-route transfer function HAR=(POW−PRW)/PTM as the product of two transfer functions: the cavity-pressure transfer function (HPCAV) and the window-pressure difference transfer function (HWPD); i.e., HAR=HPCAVHWPD. Here we summarize our conclusions regarding the effects of perforation location and size on these transfer functions.
The measurements show that HPCAV depends on perforation size and not perforation location. In contrast, measurements of HWPD do not show dependence on (1) whether the TM is intact or perforated, (2) perforation size, or (3) perforation location. Below 1000 Hz, the measurement accuracy for HWPD and HAR may be degraded by errors in the measurement of POW−PRW (Sec. III C 4), but the measurements provide an upper limit for |HWPD|.
B. Acoustic mechanisms that determine HPCAV
An analog circuit model representing the acoustic interactions in middle ears with a TM perforation is shown on the left side of Fig. 7. The topology of this model requires that the volume velocity into the cavity is the sum of the volume velocities of the TM and of air through the perforation. ZPERF and ZCAV are represented on the right side of Fig. 7 by simple connections of ideal elements based on structural features of the perforation and cavities, and acoustic theory, as detailed in other work (Voss et al., 2000, 2001c; Stepp and Voss, 2005). This model topology is used here to consider mechanisms that might influence HPCAV.
With this model (Fig. 7, left) we can relate impedance and pressure quantities that we have measured, specifically the circuit configuration requires that
(7) |
where ZCAV is the impedance of the middle-ear cavities and ZTM is the input impedance at the tympanic membrane.
Equation (7) suggests that, if |ZCAV| varies gradually with frequency, then a local maximum in |HPCAV| might occur at a local minimum in |ZTM|. This relationship is tested in Fig. 8 (left) with independent measurements of |HPCAV| (reported here) and |ZTM| [reported in Voss et al. (2001c)]. The scatter plot demonstrates that the frequency of the local minimum in the magnitude of the input impedance at the TM ZTM correlates well with the frequency of the local maximum in |HPCAV|. Note that variations in each ear are a result of changes in perforation size, which alter both coordinates. Thus, the low-frequency (0.5–2.8 kHz) maximum in |HPCAV| depends on features of both the cavities and the perforation (as ZTM depends on both quantities).
Similarly, the model suggests that the frequency of the minimum in the cavities’ impedance magnitude |ZCAV| [reported in Voss et al. (2000) and Voss et al. (2001c)] might occur at the same frequency as the minimum in |HPCAV|. This relationship is tested in Fig. 8 (right) with independent measurements of |HPCAV| and |ZCAV| [reported in Voss et al. (2000)]. The scatter plot demonstrates that the frequency of the local minimum in the cavities’ impedance magnitude |ZCAV| correlates well with the frequency of the local minimum in |HPCAV|. Thus, the minimum in |HPCAV| (0.9–2.7 kHz) depends primarily on features of the middle-ear cavities, consistent with the observation that the minimum frequency appears to be independent of perforation diameter.
The more detailed model in Fig. 7 (right) provides representations for the model impedances ZPERF and ZCAV (Fig. 7, left) (Voss et al., 2000, 2001c). The perforation is represented by a combination of mass and resistive components that depend on frequency and perforation size (Voss et al., 2001c); except for the very smallest perforations and the lowest frequencies (diameters less than 1 mm and frequencies less than 300 Hz), the perforation’s impedance is mass dominated such that the impedance magnitude |ZPERF| generally can be represented as
(8) |
where ω=2πf with f frequency and MPERF the equivalent acoustic mass of the perforation. We note that |ZPERF| increases with frequency for a constant diameter and decreases with larger perforation diameters for a constant frequency [see Fig. 3 of Voss et al. (2001c)]. The model representation for the middle-ear cavities includes two volume-velocity paths: (1) the tympanic-cavity air space, represented by a compliance, and (2) the aditus-ad-antrum leading to the antrum and mastoid-cell network represented by a series mass and resistance leading to a compliance. [This model representation is detailed in Voss et al. (2000) and Stepp and Voss (2005)]. For low frequencies3
(9) |
where CCAV is a compliance that is proportional to the cavities’ equivalent volume. The mass of the perforation and the compliance of the middle-ear cavities produce a series resonance (i.e., ZPERF+ZCAV=0) such that |HPCAV| is a maximum at
(10) |
where fmax increases with increasing perforation diameter because MPERF decreases with increasing perforation diameter. This dependence is qualitatively consistent with the observation that the frequency of the maximum in |HPCAV| increases with increasing perforation diameter (Table II). Thus, the model predicts that the frequency of the maximum in |HPCAV| is effectively determined by the dimensions of the perforation and the volume of the middle-ear air space.
For each ear, the frequency of the minimum in |HPCAV| changes moderately with perforation size and is correlated with a feature of ZCAV (Fig. 8, right). The model for ZCAV (Fig. 7, right) has a minimum in ZCAV that occurs at the frequency of the series resonance between the mass of the aditus (Mad) and the compliance of the air in the antrum and mastoid (Cmastoid) (Voss et al., 2000; Stepp and Voss, 2005) such that the frequency of the minimum in |ZCAV| occurs at
(11) |
Thus, the model predicts that the frequency of the minimum in |HPCAV| is effectively determined by the resonance between the mass that represents the aditus ad antrum and the compliance that is determined by the volume of the antrum and mastoid air space. This dependence is consistent with the observation that the frequency of the minimum in |HPCAV| does not depend on perforation size (Table II). We note that there is substantial variation in fmin among preparations, which appears to result from intra-ear structural variations in the aditus, antrum, and mastoid.
Our HPCAV results can be compared to finite-element (FE) model predictions from Gan et al. (2006). The FE model pressures that determine HPCAV are plotted in Fig. 4 of Gan et al. (2006) for an intact TM and in Fig. 6–Fig 8 of Gan et al. (2006) for small TM perforations; the comments here focus on the model predictions corresponding to pressures 2 mm from the umbo and within the middle-ear cavity. The FE model results are consistent with our measurements in that the model pressures at both the oval and round windows are nearly identical, making the calculation of HPCAV essentially independent of the location of measurement of middle-ear pressure. For an intact TM, FE model results of Gan et al. (2006) differ from both our measurements and our lumped-element model at frequencies below 1000 Hz. Both the lumped-element model of Fig. 7 and measurements of HPCAV on 11 ears with intact TMs [Fig. 2 here and Appendix G of Voss (1998)] show that the magnitude |HPCAV| is relatively independent of frequency for low frequencies (typically below 500–1000 Hz) with a corresponding angle ∠HPCAV that is nearly zero; Fig. 4 of Gan et al. (2006) shows low-frequency FE model predictions that result in |HPCAV| systematically increasing with frequency and ∠HPCAV systematically decreasing with frequency. For a perforated TM, the FE model results [Fig. 6–Fig 8 of Gan et al. (2006)] are similar to both our measurements and our lumped-element model at all frequencies; specifically, magnitude |HPCAV| is approximately 1 for low frequencies (typically below 1000 Hz) with a corresponding angle ∠HPCAV that is nearly zero, consistent with the mechanisms described in detail by Voss et al. (2001c) for how a perforation affects the pressure difference across the TM.
C. Acoustic mechanisms that determine HWPD
The quantities POW, PRW, and HWPD are not represented by the lumped-element model of Fig. 7, as the model assumes a uniform middle-ear-cavity pressure. However, we can suggest a mechanism that relates |PRW/POW| to the middle-ear cavities. The results show a consistent peak in |PRW/POW| at a frequency that varies among preparations between 800 and 3000 Hz but in a given preparation is independent of perforation size. The lack of dependence on perforation size suggests that this peak is related to the structure of the middle-ear cavities. The frequency of the peak in |PRW/POW| and the frequency of the minimum in |ZCAV| are closely correlated (Fig. 9). At the frequency of the minimum in |ZCAV|, one might expect a maximum in volume velocity (and particle velocity) entering the aditus from the tympanic cavity. This velocity maximum might produce a relatively large spatial derivative in pressure4 in the region of the windows and therefore an increased difference between PRW and POW. Thus, a feature of the middle-ear cavity structure might determine the peak frequency of |PRW/POW|.
In the future, finite-element models might provide additional insight into the relationship between POW and PRW. The plots and text in Gan et al. (2006) are consistent with small differences between POW and PRW.
D. Effects of reduced middle-ear air space
Measurements in Stepp and Voss (2005) demonstrate that reduction of the mastoid portion of the cadaver ears influences middle-ear acoustics. The measurements presented here were made on bones that were removed with a circular saw (Schuknecht, 1968) such that much of the mastoid air-cell network was removed. The demonstrable effects of this loss of mastoid air cells are a decrease in total middle-ear air-space volume and removal of highly individualistic resonances in the cavity impedance at frequencies above 1000 Hz (Stepp and Voss, 2005). These results suggest that, if the acoustic-route measurements reported here had been made on ears with intact mastoid spaces, changes would be:
Greater inter-ear variability in HPCAV as a result of inter-specimen structural variations of mastoid air spaces; specifically, the frequencies and values of the extrema in HPCAV at higher frequencies (i.e., f>1000 Hz) would be altered.
Larger changes between the intact and the perforated |HPCAV|, especially at the lower frequencies (f<1000 Hz) where the acoustics are compliance dominated. Specifically, the larger cavity volumes would lead to smaller low frequency |HPCAV| with an intact TM, whereas a perforation would still make HPCAV≈1 for the lower frequencies.
As HWPD is apparently determined by the acoustic configuration of the middle-ear cavities, it seems likely that HWPD would also have different features with intact cavities.
E. Conditions in which the acoustic route may be important for hearing with tympanic-membrane perforations
1. Overview
As discussed in the Introduction, when an ear is normal, the ossicular route is the dominant mechanism for sound transmission to the cochlea, and transmission via the acoustic route is negligibly small. Figure 6 demonstrates that sound transmission via the acoustic route increases when the TM is perforated. Here, we look for situations in ears with perforations in which the acoustic route becomes significant.
Voss et al. (2001b) present measurements of the middle-ear transfer function VS /PTM (stapes velocity per pressure at the TM) made with both intact and perforated TMs. These measures are assumed to include transmission via both the ossicular and acoustic routes:
(12) |
In this section, we use our measurements of the acoustic-route transfer function HAR to compute an upper bound for the acoustic-route transmission . We then compare this upper bound with our measurements of (Voss et al., 2001b) in order to determine the importance of the acoustic-route component in the total transmission.
2. Comparison of acoustic route transmission to normal middle-ear transmission
In this section, we compare the total middle-ear transmission to the acoustic-route transmission for ears with either intact or missing TMs.
The stapes velocity per pressure at the TM that results from the pressure difference at the oval and round windows, , can be expressed in terms of three quantities: the pressure measurements at the oval and round windows, the stapes-cochlea acoustic impedance ZSC, and the area of the stapes footplate AS
(13) |
Here we use the average ZSC measured in cadaveric temporal bones by Merchant et al. (1996) and the average AS =3.2 mm2 reported by Wever and Lawrence (1954, p. 417).
Equation (13) was used to compute the mean for both the TM intact and TM removed cases (two lower curves in the top plot of Fig. 10); these curves are upper bounds for middle-ear sound transmission with either the TM intact or removed. The magnitude is larger with TM removed because |HAR| is larger (see Fig. 5). Higher in the top plot (Fig. 10) is the mean measured total middle-ear sound transmission from Fig. 4 of Voss et al. (2000). The magnitude of the total transmission relative to the acoustic-route transmission (in the lower plot of Fig. 10) describes the importance of the acoustic route in sound transmission to the cochlea. With an intact TM, the total stapes velocity is 100–3000 times (i.e., 40–70 dB) greater than the upper bound on the acoustic-route stapes velocity (Fig. 10, lower). Thus, when the TM and ossicular chain are normal, transmission via the acoustic route is negligibly small relative to the ossicular route.
The measurements of HAR allow us to calculate an upper bound for hearing loss with the TM removed; measurements of stapes velocity under this condition are not available because the stapes motion was below the noise floor of the measurement system. HAR for the TM-removed condition is similar to that with TM perforations (Fig. 6). When the TM is removed (or perforated) the upper bound on transmission via the acoustic route increases (Fig. 10) and the total transmission decreases (not shown), with specific decreases dependent on the perforation size (Voss et al. 2001b). When the decrease in is substantial (e.g., with larger perforations), the acoustic-route transmission could make significant contributions to the total transmission and thus determine the hearing loss. This upper hearing-loss limit is equivalent to the ratio between total sound transmission in the intact condition (with an intact TM) and the upper bound on the acoustic-route sound transmission in the TM removed condition ( with the TM removed). This estimate of an upper limit for loss with TM perforations is included in the lower part of Fig. 10. The limit is between 40 and 60 dB at frequencies up to 2000 Hz, and from 2000 to 4000 Hz between 30 and 40 dB. These limits are comparable to the 45–65 dB hearing losses that Békésy (1936) reported in patients with missing TMs, mallei, and incudes (Békésy, 1936; Peake et al., 1992).
Figure 11 compares total transmission loss with different sized TM perforations (Voss et al., 2001a, b) to an estimated upper limit for transmission loss that is determined by the acoustic route. At most frequencies, even with perforations, the measured stapes-velocity (VS) losses are above the limit set by the acoustic route, indicating that the ossicular route dominates the stapes-velocity measurements. However, the plotted upper limit for the “acoustic-route” suggests that the acoustic route may limit the loss at the lowest frequencies, especially for the larger perforations, where the measured losses begin to approach the acoustic-route limit. The measured losses are limited at the lowest frequencies by the noise floor for stapes velocity, but models of middle-ear sound transmission with perforations predict that the low-frequency losses increase as frequency decreases (Voss et al., 2001c); for perforations greater than about 1 mm in diameter, the model predicts that changes in the pressure difference across the TM dominate the total loss in the ossicular route and that at low frequencies these losses increase with decreasing frequency at 40 dB/ decade. These predictions are included on the plot in Fig. 11, showing that the acoustic route could contribute substantially with the larger perforations at the lowest frequencies (e.g., less than 500 Hz).
Figure 11 also plots the mean audiogram measured by Békésy (1936) on five ears missing the TM, malleus, incus, and stapes. In these ears, it seems that the acoustic route could be responsible for hearing. That is, the measured hearing loss is comparable to the upper limit for the acoustic route for frequencies less than 4000 Hz. Thus, this audiogram is consistent with the hypothesis that hearing in this condition is determined by the acoustic route5 (Peake et al., 1992; Mehta et al., 2006).
VI. CONCLUSIONS
Middle-ear sound transmission with perforated tympanic membranes is dominated by sound transmission via the ossicular system (ossicular route) for most perforation sizes; the acoustic route dominates when the TM is missing. Direct acoustic stimulation of the cochlear windows (acoustic route) provides a significant amount of sound transmission only at the lowest frequencies with a condition approaching total removal of the tympanic membrane. Sound transmission via the acoustic route is independent of perforation location but does depend on perforation size. These variations of sound transmission via the acoustic route result entirely from changes in transmission of sound from the ear canal to the middle-ear cavity, measured here as HPCAV. In fact, the dependence of the window-pressure ratio PRW/POW and the window-pressure difference HWPD on the pressure in the middle-ear cavity appear independent of (1) the presence of a tympanic-membrane perforation, (2) perforation size, and (3) perforation location. In other words, the relative magnitudes and angles of the pressures just outside the oval and round windows are unaffected by any tympanic-membrane perforation. The results (1) refute the common clinical view (described in the Introduction) that perforation location affects the relative phase of the sound pressures at the oval and round windows, and (2) provides the most complete existing description of the window pressure ratio PRW/POW based on experimental data.
ACKNOWLEDGMENTS
This work was supported by training and research grants from the NIDCD. The measurements were part of the Ph.D. thesis of S.E.V. within the Speech and Hearing Bioscience and Technology Program of the Harvard-MIT Division of Health Sciences and Technology. We thank Diane Jones of the Oto-Pathology Laboratory at the Massachusetts Eye and Ear Infirmary for obtaining temporal bones and Christopher Shera of the Eaton-Peabody Laboratory at the Massachusetts Eye and Ear Infirmary for helpful discussions.
Footnotes
For the group of eight bones, there exist occasional frequency bands where the variation exceeds 0.25 dB in magnitude and 0.005 cycles in angle; such bands are rare and narrow. Fig. 3-3 of Voss (1998) provides an example.
The plot of ∠HPCAV for bone 24L with the TM intact shows an angle that is above zero at the lowest frequencies. However, the other ten bones have mean angles that are essentially zero at the lowest frequencies.
Equation (9) is valid up to a frequency that depends on the volume of the middle-ear cavity. As the volume increases, the low-frequency range for which Eq. (9) holds decreases; plots for the ZCAV corresponding to each preparation can be found in Fig. 2 of Voss et al. (2001c). Each fmax listed in Table II for |HPCAV| in the range of 0.5–2.8 kHz generally occurs at a frequency where the approximation of Eq. (9) holds.
Newton’s second law in acoustics states: ∂P/∂x=−jωρVx. If the particle velocity |Vx| going into the aditus is a maximum (i.e., at the resonant frequency ), then |∂P/∂x| will also be a maximum.
These results of Békésy (1936) are unique in that they include thresholds for frequencies from 5 to 4000 Hz, which are shown in Fig. 11 only for 100–4000 Hz. The results below 100 Hz are difficult to interpret because the mean loss decreases for lower frequencies becoming about 10 dB at 5 Hz. These results led Békésy (1936) to conclude that “something apart from the pressure difference between the stapes and round window must be considered as producing the effects” (Békésy, 1960, p. 106). See Peake et al.(1992), (pp. 258–259) for further discussion of this issue.
Contributor Information
Susan E. Voss, Picker Engineering Program, Smith College, 51 College Lane, Northampton, Massachusetts 01063.
John J. Rosowski, Eaton-Peabody Laboratory of Auditory Physiology, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts 02115 and Speech and Hearing Bioscience and Technology Program, Harvard-M.I.T. Division of Health Sciences and Technology, Cambridge, Massachusetts 02139
Saumil N. Merchant, Eaton-Peabody Laboratory of Auditory Physiology, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts 02115 and Speech and Hearing Bioscience and Technology Program, Harvard-M.I.T. Division of Health Sciences and Technology, Cambridge, Massachusetts 02139
William T. Peake, Eaton-Peabody Laboratory of Auditory Physiology, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, and Speech and Hearing Bioscience and Technology Program, Harvard-M.I.T. Division of Health Sciences and Technology, Cambridge, Massachusetts 02139
References
- Békésy Gv. Zur Physik des Mittelohres und über das Hören bei fehlerhaftem Trommelfell (On the physics of the middle ear and hearing with a missing eardrum) Akust. Z. 1936;1:13–23. (English translation pp. 104-115 in Békésy, 1960) [Google Scholar]
- Békésy Gv. The sound pressure difference between the round and the oval windows and the artificial window of labyrinthine fenestration. Acta Oto-Laryngol. 1947;35:301–315. [Google Scholar]
- Békésy Gv. In: Experiments in Hearing. Wever EG, editor. New York: McGraw-Hill; 1960. [Google Scholar]
- Efron B, Tibshirani RJ. An Introduction to the Bootstrap. London: Chapman and Hall; 1993. [Google Scholar]
- Gan RZ, Sun Q, Feng B, Wood MW. Acoustic-structural coupled finite element analysis for sound transmission in human ear—Pressure distributions. Med. Eng. Phys. 2006;28:395–404. doi: 10.1016/j.medengphy.2005.07.018. [DOI] [PubMed] [Google Scholar]
- Glasscock ME, Shambaugh GE. Surgery of the Ear. 4th ed. Philadelphia: Saunders; 1990. [Google Scholar]
- Lynch TJ. Ph.D. thesis. Massachusetts Institute of Technology; 1981. Signal Processing by the Cat Middle Ear: Admittance and Transmission, Measurements and Models. [Google Scholar]
- Mehta RP, Rosowski JJ, Voss SE, O’Neil E, Merchant SN. Determinants of hearing loss in perforations of the tympanic membrane. Otol. Neurotol. 2006;27:136–143. doi: 10.1097/01.mao.0000176177.17636.53. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Merchant SN, Ravicz ME, Rosowski JJ. Acoustic input impedance of the stapes and cochlea in human temporal bones. Hear. Res. 1996;97:30–45. [PubMed] [Google Scholar]
- Merchant SN, Ravicz ME, Puria S, Voss SE, Whittemore KR, Jr, Peake WT, Rosowski JJ. Analysis of middle-ear mechanics and application to diseased and reconstructed ears. Am. J. Otol. 1997a;18:139–154. [PubMed] [Google Scholar]
- Merchant SN, Ravicz ME, Rosowski JJ. Mechanics of type IV tympanoplasty: Experimental findings and surgical implications. Ann. Otol. Rhinol. Laryngol. 1997b;106:49–60. doi: 10.1177/000348949710600110. [DOI] [PubMed] [Google Scholar]
- Peake W, Rosowski JJ, Lynch TJ. Middle-ear transmission: Acoustic versus ossicular coupling in cat and human. Hear. Res. 1992;57:245–268. doi: 10.1016/0378-5955(92)90155-g. [DOI] [PubMed] [Google Scholar]
- Pickles JO. Physiology of the ear Chap. 2. In: Wright D, editor. Scott-Brown’s Otolaryngology: Basic Sciences. Vol. 1. London: Butterworths; 1987. pp. 59–60. [Google Scholar]
- Schmitt H. Uber die bedeutung der schalldrucktransformation und der schallprotektion für die hörschwelle (About the importance of sound pressure transformation and the acoustic protection for the hearing threshold) Acta Oto-Laryngol. 1958;49:71–80. doi: 10.3109/00016485809134729. [DOI] [PubMed] [Google Scholar]
- Schuknecht H. Temporal bone removal at autopsy. Arch. Otolaryngol. 1968;87:129–137. doi: 10.1001/archotol.1968.00760060131007. [DOI] [PubMed] [Google Scholar]
- Schuknecht HF. Pathology of the Ear. 2nd ed. Malvern, PA: Lea and Febiger; 1993. [Google Scholar]
- Stepp CE, Voss SE. Acoustics of the human middle-ear air space. J. Acoust. Soc. Am. 2005;118:861–871. doi: 10.1121/1.1974730. [DOI] [PubMed] [Google Scholar]
- Voss SE. Master’s thesis. Massachusetts Institute of Technology; 1995. Is the Pressure Difference Between the Oval and Round Windows the Effective Acoustic Stimulus for the Inner Ear? [DOI] [PubMed] [Google Scholar]
- Voss SE. Ph.D. thesis. Massachusetts Institute of Technology; 1998. Effects of Tympanic-Membrane Perforations on Middle-Ear Sound Transmission: Measurements, Mechanisms, and Models. [Google Scholar]
- Voss SE, Rosowski JJ, Peake WT. Is the pressure difference between the oval and round windows the effective acoustic stimulus for the cochlea? J. Acoust. Soc. Am. 1996;100:1602–1616. doi: 10.1121/1.416062. [DOI] [PubMed] [Google Scholar]
- Voss SE, Rosowski JJ, Merchant SN, Peake WT. Acoustic responses of the human middle ear. Hear. Res. 2000;150:43–69. doi: 10.1016/s0378-5955(00)00177-5. [DOI] [PubMed] [Google Scholar]
- Voss SE, Rosowski JJ, Merchant SN, Peake WT. How do tympanic-membrane perforations affect human middle-ear sound transmission? Acta Oto-Laryngol. 2001a;121:169–173. doi: 10.1080/000164801300043343. [DOI] [PubMed] [Google Scholar]
- Voss SE, Rosowski JJ, Merchant SN, Peake WT. Middle-ear function with tympanic-membrane perforations. I Measurements and mechanisms. J. Acoust. Soc. Am. 2001b;110:1432–1444. doi: 10.1121/1.1394195. [DOI] [PubMed] [Google Scholar]
- Voss SE, Rosowski JJ, Merchant SN, Peake WT. Middle-ear function with tympanic-membrane perforations. II. A simple model. J. Acoust. Soc. Am. 2001c;110:1445–1452. doi: 10.1121/1.1394196. [DOI] [PubMed] [Google Scholar]
- Wever EG, Lawrence M. Physiological Acoustics. Princeton, NJ: Princeton University Press; 1954. [Google Scholar]