Abstract
An enzyme-linked immunosorbent assay (ELISA) for total antibodies to Toxoplasma gondii was modified to measure specific immunoglobulin M (IgM) antibodies. The assay requires three incubation periods totaling 2 h and enzyme-labeled-heavy-chain-specific antibodies to human IgM. The objective read-out in absorbance was normalized to percent of a standardized positive control for interpretations. No difference was observed between the assay results with or without previous absorption of the samples by Staphylococcus aureus protein A to remove most of the IgG antibodies. Addition of serum containing very high levels of IgG antibodies to another containing both IgG and IgM antibodies did not change the IgM assay values for the latter. None of the 22 sera containing high levels of IgM rheumatoid factor (RF) gave positive ELISA IgM results, even though 8 of them also had high levels of IgG toxoplasma antibodies. Mixtures of sera containing high concentrations of RF with sera having high levels of IgG toxoplasma antibodies also failed to show any false-positive reactions in the IgM toxoplasma assay. Thus, this ELISA for T. gondii IgM antibodies was not affected by IgG toxoplasma antibodies and RF.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Camargo M. E., Ferreira A. W., Mineo J. R., Takiguti C. K., Nakahara O. S. Immunoglobulin G and immunoglobulin M enzyme-linked immunosorbent assays and defined toxoplasmosis serological patterns. Infect Immun. 1978 Jul;21(1):55–58. doi: 10.1128/iai.21.1.55-58.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Camargo M. E., Leser P. G., Rocca A. Rheumatoid factors as a cause for false positive IgM anti-toxoplasma fluorescent tests. A technique for specific results. Rev Inst Med Trop Sao Paulo. 1972 Sep-Oct;14(5):310–313. [PubMed] [Google Scholar]
- Cohen I. R., Norins L. C., Julian A. J. Competition between, and effectiveness of, IgG and IgM antibodies in indirect fluorescent antibody and other tests. J Immunol. 1967 Jan;98(1):143–149. [PubMed] [Google Scholar]
- Desmonts G., Naot Y., Remington J. S. Immunoglobulin M-immunosorbent agglutination assay for diagnosis of infectious diseases: diagnosis of acute congenital and acquired Toxoplasma infections. J Clin Microbiol. 1981 Nov;14(5):486–491. doi: 10.1128/jcm.14.5.486-491.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Filice G. A., Yeager A. S., Remington J. S. Diagnostic significance of immunoglobulin M antibodies to Toxoplasma gondii detected after separation of immunoglobulin M from immunoglobulin G antibodies. J Clin Microbiol. 1980 Sep;12(3):336–342. doi: 10.1128/jcm.12.3.336-342.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Franco E. L., Walls K. W., Sulzer A. J. Reverse enzyme immunoassay for detection of specific anti-Toxoplasma immunoglobulin M antibodies. J Clin Microbiol. 1981 May;13(5):859–864. doi: 10.1128/jcm.13.5.859-864.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Halbert S. P., Karsh J., Anken M. A quantitative enzyme immunoassay for IgM rheumatoid factor using human immunoglobulin G as substrate. Am J Clin Pathol. 1980 Dec;74(6):776–784. doi: 10.1093/ajcp/74.6.776. [DOI] [PubMed] [Google Scholar]
- Hyde B., Barnett E. V., Remington J. S. Method for differentiation of nonspecific from specfic toxoplasma IgM fluorescent antibodies in patients with rheumatoid factor. Proc Soc Exp Biol Med. 1975 Apr;148(4):1184–1188. doi: 10.3181/00379727-148-38713. [DOI] [PubMed] [Google Scholar]
- Kessler S. W. Rapid isolation of antigens from cells with a staphylococcal protein A-antibody adsorbent: parameters of the interaction of antibody-antigen complexes with protein A. J Immunol. 1975 Dec;115(6):1617–1624. [PubMed] [Google Scholar]
- Knez V., Stewart J. A., Ziegler D. W. Cytomegalovirus specific IgM and IgG response in humans studied by radioimmunoassay. J Immunol. 1976 Nov;117(5 PT2):2006–2013. [PubMed] [Google Scholar]
- Konishi E., Takahashi J. Reproducible enzyme-linked immunosorbent assay with a magnetic processing system for diagnosis of toxoplasmosis. J Clin Microbiol. 1983 Feb;17(2):225–231. doi: 10.1128/jcm.17.2.225-231.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lin T. M., Halbert S. P., O'Connor G. R. Standardized quantitative enzyme-linked immunoassay for antibodies to Toxoplasma gondii. J Clin Microbiol. 1980 Jun;11(6):675–681. doi: 10.1128/jcm.11.6.675-681.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Middeldorp J. M., Jongsma J., ter Haar A., Schirm J., The T. H. Detection of immunoglobulin M and G antibodies against cytomegalovirus early and late antigens by enzyme-linked immunosorbent assay. J Clin Microbiol. 1984 Oct;20(4):763–771. doi: 10.1128/jcm.20.4.763-771.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mineo J. R., Camargo M. E., Ferreira A. W. Enzyme-linked immunosorbent assay for antibodies to Toxoplasma gondii polysaccharides in human toxoplasmosis. Infect Immun. 1980 Feb;27(2):283–287. doi: 10.1128/iai.27.2.283-287.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ordonez G. A., Newman J. T., Stone M. J. Serological diagnosis of Toxoplasma gondii infections by rapid separation of serum immunoglobulins M and G with CM Bio-Gel A. J Clin Microbiol. 1982 Oct;16(4):751–753. doi: 10.1128/jcm.16.4.751-753.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Partanen P., Seppänen H., Suni J., Vaheri A. Selective reactivity of antibodies to human immunoglobulins G, M, and A with rubella virus proteins. J Clin Microbiol. 1985 May;21(5):800–802. doi: 10.1128/jcm.21.5.800-802.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Partanen P., Turunen H. J., Paasivuo R., Forsblom E., Suni J., Leinikki P. O. Identification of antigenic components of Toxoplasma gondii by an immunoblotting technique. FEBS Lett. 1983 Jul 25;158(2):252–254. doi: 10.1016/0014-5793(83)80589-4. [DOI] [PubMed] [Google Scholar]
- Pettersen E. K. Investigation of two commercially available kits for determination of IgG and IgM to Toxoplasma gondii by enzyme-linked immunosorbent assay (ELISA). Acta Pathol Microbiol Immunol Scand C. 1984 Oct;92(5):325–329. doi: 10.1111/j.1699-0463.1984.tb00095.x. [DOI] [PubMed] [Google Scholar]
- Pyndiah N., Krech U., Price P., Wilhelm J. Simplified chromatographic separation of immunoglobulin M from G and its application to toxoplasma indirect immunofluorescence. J Clin Microbiol. 1979 Feb;9(2):170–174. doi: 10.1128/jcm.9.2.170-174.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schmitz H., Scherer M. IgM antibodies to Epstein-Barr virus in infectious mononucleosis. Arch Gesamte Virusforsch. 1972;37(4):332–339. doi: 10.1007/BF01241456. [DOI] [PubMed] [Google Scholar]
- Skaug K., Tjotta E. Diagnosis of recent Herpes simplex infections. A modified immunofluorescent test for the detection of specific Herpes simplex IgM antibodies after staphylococcal adsorption of IgG. Acta Pathol Microbiol Scand B Microbiol Immunol. 1974 Jun;82(3):323–328. [PubMed] [Google Scholar]
- Walls K. W., Bullock S. L., English D. K. Use of the enzyme-linked immunosorbent assay (ELISA) and its microadaptation for the serodiagnosis of toxoplasmosis. J Clin Microbiol. 1977 Mar;5(3):273–277. doi: 10.1128/jcm.5.3.273-277.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Welch P. C., Masur H., Jones T. C., Remington J. S. Serologic diagnosis of acute lymphadenopathic toxoplasmosis. J Infect Dis. 1980 Aug;142(2):256–264. doi: 10.1093/infdis/142.2.256. [DOI] [PubMed] [Google Scholar]
- Wielaard F., van Gruijthuijsen H., Duermeyer W., Joss A. W., Skinner L., Williams H., van Elven E. H. Diagnosis of acute toxoplasmosis by an enzyme immunoassay for specific immunoglobulin m antibodies. J Clin Microbiol. 1983 Jun;17(6):981–987. doi: 10.1128/jcm.17.6.981-987.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- van Loon A. M., van der Logt J. T., Heessen F. W., van der Veen J. Enzyme-linked immunosorbent assay that uses labeled antigen for detection of immunoglobulin M and A antibodies in toxoplasmosis: comparison with indirect immunofluorescence and double-sandwich enzyme-linked immunosorbent assay. J Clin Microbiol. 1983 Jun;17(6):997–1004. doi: 10.1128/jcm.17.6.997-1004.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]