Abstract
A micro enzyme-linked immunosorbent assay was used to detect the presence of amoebic antigen in polyethylene-glycol-precipitated circulating immune complexes (CIC). A cutoff dilution of greater than 1:160 for the precipitates was taken to be of clinical significance. Among the patients with amoebic liver abscess, 93% (14 of 15 confirmed cases) had indications of amoebic antigen in CIC. In 57% of the suspected cases of amoebic liver abscess, amoebic antigen could be detected in CIC. The specificity of the technique for the demonstration of specific amoebic antigen is indicated by the undetectable levels of amoebic antigen in CIC in serum samples from nine cases of nonamoebic hepatic diseases and 10 apparently healthy subjects. It is thus believed that the specific diagnosis of an individual case of amoebic liver abscess can be made by demonstrating specific amoebic antigen in CIC.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Abioye A. A., Lewis E. A., McFarlane H. Clinical evaluation of serum immunoglobulins in amoebiasis. Immunology. 1972 Dec;23(6):937–946. [PMC free article] [PubMed] [Google Scholar]
- FRANKLIN E. C., HOLMAN H. R., MULLER-EBERHARD H. J., KUNKEL H. G. An unusual protein component of high molecular weight in the serum of certain patients with rheumatoid arthritis. J Exp Med. 1957 May 1;105(5):425–438. doi: 10.1084/jem.105.5.425. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Healy G. R., Visvesvara G. S., Kagan I. G. Observations on the persistence of antibodies to E. histolytica. Arch Invest Med (Mex) 1974;5(Suppl 2):495–500. [PubMed] [Google Scholar]
- Jeanes A. L. Indirect fluorescent antibody test in diagnosis of hepatic amoebiasis. Br Med J. 1966 Jun 11;1(5501):1464–1464. doi: 10.1136/bmj.1.5501.1464. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Juniper K., Jr, Worrell C. L., Minshew M. C., Roth L. S., Cypert H., Lloyd R. E. Serologic diagnosis of amebiasis. Am J Trop Med Hyg. 1972 Mar;21(2):157–168. doi: 10.4269/ajtmh.1972.21.157. [DOI] [PubMed] [Google Scholar]
- KESSEL J. F., LEWIS W. P., MA S., KIM H. Preliminary report on a hemagglutination test for entamoebae. Proc Soc Exp Biol Med. 1961 Feb;106:409–413. doi: 10.3181/00379727-106-26355. [DOI] [PubMed] [Google Scholar]
- Natali P. G., Cioli D. Immune complex nephritis in Schistosoma mansoni-infected mice. Eur J Immunol. 1976 May;6(5):359–364. doi: 10.1002/eji.1830060511. [DOI] [PubMed] [Google Scholar]
- Ngu J. L., Blackett K. Complement and immunoconglutinin changes in the nephrotic syndrome of adult Africans. J Trop Med Hyg. 1970 Oct;73(10):250–254. [PubMed] [Google Scholar]
- Núti M., D'Amelio R., Seminara R., Palmisano L., Aiuti F. Circulating immune complexes in amoebiasis. Trans R Soc Trop Med Hyg. 1982;76(4):567–568. doi: 10.1016/0035-9203(82)90168-7. [DOI] [PubMed] [Google Scholar]
- Onyemelukwe G. C., Onyewotu I. I. Amoebic liver abscess--serum anticomplementary screening for immune complexes. Trans R Soc Trop Med Hyg. 1981;75(4):613–614. doi: 10.1016/0035-9203(81)90225-x. [DOI] [PubMed] [Google Scholar]
- Pillai S., Mohimen A. A solid-phase sandwich radioimmunoassay for Entamoeba histolytica proteins and the detection of circulating antigens in amoebiasis. Gastroenterology. 1982 Dec;83(6):1210–1216. [PubMed] [Google Scholar]
- Sawhney S., Chakravarti R. N., Jain P., Vinayak V. K. Immunogenicity of axenic Entamoeba histolytica antigen and its fractions. Trans R Soc Trop Med Hyg. 1980;74(1):26–35. doi: 10.1016/0035-9203(80)90006-1. [DOI] [PubMed] [Google Scholar]
- Shahin B., Papadopoulou Z. L., Jenis E. H. Congenital nephrotic syndrome associated with congenital toxoplasmosis. J Pediatr. 1974 Sep;85(3):366–370. doi: 10.1016/s0022-3476(74)80117-4. [DOI] [PubMed] [Google Scholar]
- Thomas V., Sinniah B., Leng Y. P. Assessment of the sensitivity, specificity, and reproducibility of the indirect immunofluorescent technique for the diagnosis of amebiasis. Am J Trop Med Hyg. 1981 Jan;30(1):57–62. doi: 10.4269/ajtmh.1981.30.57. [DOI] [PubMed] [Google Scholar]
- Vinayak V. K., Jain P., Gupta B., Kaushik S. P., Sawhney S. Cellular and humoral responses in amoebic patients. Trop Geogr Med. 1980 Dec;32(4):298–302. [PubMed] [Google Scholar]
- Vinayak V. K., Prakash O., Talwar G. P., Tandon B. N., Mohapatra L. N. Evaluation of gel diffusion precipitin test for amoebiasis. Indian J Med Res. 1974 Sep;62(9):1317–1322. [PubMed] [Google Scholar]
- Vinayak V. K., Prakash O., Talwar G. P., Tandon B. N., Mohapatra L. N. Significance of the indirect haemagglutination test for the diagnosis of amoebiasis. Indian J Med Res. 1974 Aug;62(8):1171–1175. [PubMed] [Google Scholar]
- Vinayak V. K., Sawhney S., Jain P., Chugh S., Naik S. R., Chakravarti R. N. Virulence of Entamoeba histolytica in rat and its comparison with the serological responses of the amoebic patients. Trans R Soc Trop Med Hyg. 1981;75(1):32–37. doi: 10.1016/0035-9203(81)90010-9. [DOI] [PubMed] [Google Scholar]