Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1986 Sep;24(3):353–356. doi: 10.1128/jcm.24.3.353-356.1986

Volume of blood submitted for culture from neonates.

P R Neal, M B Kleiman, J K Reynolds, S D Allen, J A Lemons, P L Yu
PMCID: PMC268912  PMID: 3760131

Abstract

We prospectively examined 298 sets (298 aerobic, 299 anaerobic, and 73 resin cultures) of blood cultures from 161 critically ill newborns. The attending physicians were unaware of the study. The mean blood volume per patient (aerobic and anaerobic) was 1.05 (range, 0.11 to 3.04) ml. The mean blood volume per aerobic bottle was 0.53 (range, 0.01 to 1.90) ml. Among aerobic samples 2.7% were less than or equal to 0.1 ml, 16% were less than or equal to 0.3 ml, 33% were less than or equal to 0.4 ml, and 55% were less than or equal to 0.5 ml. For anaerobic cultures the mean blood volume was 0.52 (range, 0.01 to 1.79) ml. Among anaerobic samples 2.7% were less than or equal to 0.1 ml, 15% were less than or equal to 0.3 ml, 35% were less than or equal to 0.4 ml, and 58% were less than or equal to 0.5 ml. Blood volume did not correlate with gestational age, chronologic age, or weight. The mean volume of blood submitted in positive cultures was not significantly greater than that in negative cultures. The blood volume used for culture from ill newborns may be inadequate for detecting sepsis, and the adequacy of currently available culture methods needs to be assessed for the small samples submitted from critically ill newborns.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Campos J. M., Spainhour J. R. Rapid detection of bacteremia in children with a modified lysis direct plating method. J Clin Microbiol. 1985 Oct;22(4):674–676. doi: 10.1128/jcm.22.4.674-676.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Carey R. B. Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children. J Clin Microbiol. 1984 May;19(5):634–638. doi: 10.1128/jcm.19.5.634-638.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Dietzman D. E., Fischer G. W., Schoenknecht F. D. Neonatal Escherichia coli septicemia--bacterial counts in blood. J Pediatr. 1974 Jul;85(1):128–130. doi: 10.1016/s0022-3476(74)80308-2. [DOI] [PubMed] [Google Scholar]
  4. Hall M. M., Ilstrup D. M., Washington J. A., 2nd Effect of volume of blood cultured on detection of bacteremia. J Clin Microbiol. 1976 Jun;3(6):643–645. doi: 10.1128/jcm.3.6.643-645.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Knudson R. P., Alden E. R. Neonatal heelstick blood culture. Pediatrics. 1980 Mar;65(3):505–507. [PubMed] [Google Scholar]
  6. Mangurten H. H., LeBEAU L. J. Diagnosis of neonatal bacteremia by a microblood culture technique. A preliminary report. J Pediatr. 1977 Jun;90(6):990–992. doi: 10.1016/s0022-3476(77)80578-7. [DOI] [PubMed] [Google Scholar]
  7. Plorde J. J., Tenover F. C., Carlson L. G. Specimen volume versus yield in the BACTEC blood culture system. J Clin Microbiol. 1985 Aug;22(2):292–295. doi: 10.1128/jcm.22.2.292-295.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Szymczak E. G., Barr J. T., Durbin W. A., Goldmann D. A. Evaluation of blood culture procedures in a pediatric hospital. J Clin Microbiol. 1979 Jan;9(1):88–92. doi: 10.1128/jcm.9.1.88-92.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Welch D. F., Scribner R. K., Hensel D. Evaluation of a lysis direct plating method for pediatric blood cultures. J Clin Microbiol. 1985 Jun;21(6):955–958. doi: 10.1128/jcm.21.6.955-958.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES