Abstract
A modified Minitek system (BBL Microbiology Systems, Cockeysville, Md.) for species identification of coagulase-negative staphylococci was compared with the Staph-Ident system (Analytab Products, Plainview, N.Y.). The conventional method of Kloos and Schleifer (J. Clin. Microbiol. 1:82-88, 1975) was used as the reference method for identification. When tested with 78 coagulase-negative staphylococcal isolates from 63 children with cancer. Minitek concurred with the conventional identification in 67 (86%) isolates and Staph-Ident concurred in 61 (78%) isolates. Identification of species other than Staphylococcus epidermidis was better with Staph-Ident (19 of 23 isolates) than with Minitek (14 of 23 isolates). Concordance of results was likewise high, 88% (7 of 8) for Minitek and 100% (8 of 8) for Staph-Ident in studies with eight coagulase-negative staphylococcal strains obtained from the American Type Culture Collection (Rockville, Md.). We conclude that the modified Minitek system is a practical and reliable test for identifying coagulase-negative staphylococci in clinical microbiology laboratories. Its versatility and larger repertoire of biochemical tests may offer advantages over the Staph-Ident system.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Aldridge K. E., Stratton C. W., Patterson L. S., Evans M. E., Hodges R. L. Comparison of the Staph-Ident system with a conventional method for species identification of urine and blood isolates of coagulase-negative staphylococci. J Clin Microbiol. 1983 Mar;17(3):516–520. doi: 10.1128/jcm.17.3.516-520.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Almeida R. J., Jorgensen J. H. Identification of coagulase-negative staphylococci with the API STAPH-IDENT system. J Clin Microbiol. 1983 Aug;18(2):254–257. doi: 10.1128/jcm.18.2.254-257.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Almeida R. J., Jorgensen J. H., Johnson J. E. Evaluation of the automicrobic system gram-positive identification card for species identification of coagulase-negative staphylococci. J Clin Microbiol. 1983 Aug;18(2):438–439. doi: 10.1128/jcm.18.2.438-439.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bauer A. W., Kirby W. M., Sherris J. C., Turck M. Antibiotic susceptibility testing by a standardized single disk method. Am J Clin Pathol. 1966 Apr;45(4):493–496. [PubMed] [Google Scholar]
- Eng R. H., Wang C., Person A., Kiehn T. E., Armstrong D. Species identification of coagulase-negative staphylococcal isolates from blood cultures. J Clin Microbiol. 1982 Mar;15(3):439–442. doi: 10.1128/jcm.15.3.439-442.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Giger O., Charilaou C. C., Cundy K. R. Comparison of the API Staph-Ident and DMS Staph-Trac systems with conventional methods used for the identification of coagulase-negative staphylococci. J Clin Microbiol. 1984 Jan;19(1):68–72. doi: 10.1128/jcm.19.1.68-72.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gill V. J., Selepak S. T., Williams E. C. Species identification and antibiotic susceptibilities of coagulase-negative staphylococci isolated from clinical specimens. J Clin Microbiol. 1983 Dec;18(6):1314–1319. doi: 10.1128/jcm.18.6.1314-1319.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hussain Z., Stoakes L., Stevens D. L., Schieven B. C., Lannigan R., Jones C. Comparison of the MicroScan system with the API Staph-Ident system for species identification of coagulase-negative staphylococci. J Clin Microbiol. 1986 Jan;23(1):126–128. doi: 10.1128/jcm.23.1.126-128.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- John J. F., Jr, Gramling P. K., O'Dell N. M. Species identification of coagulase-negative staphylococci from urinary tract isolates. J Clin Microbiol. 1978 Oct;8(4):435–437. doi: 10.1128/jcm.8.4.435-437.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kloos W. E., Schleifer K. H. Simplified scheme for routine identification of human Staphylococcus species. J Clin Microbiol. 1975 Jan;1(1):82–88. doi: 10.1128/jcm.1.1.82-88.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kloos W. E., Wolfshohl J. F. Identification of Staphylococcus species with the API STAPH-IDENT system. J Clin Microbiol. 1982 Sep;16(3):509–516. doi: 10.1128/jcm.16.3.509-516.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Masur H., Johnson W. D., Jr Prosthetic valve endocarditis. J Thorac Cardiovasc Surg. 1980 Jul;80(1):31–37. [PubMed] [Google Scholar]
- Schoenbaum S. C., Gardner P., Shillito J. Infections of cerebrospinal fluid shunts: epidemiology, clinical manifestations, and therapy. J Infect Dis. 1975 May;131(5):543–552. doi: 10.1093/infdis/131.5.543. [DOI] [PubMed] [Google Scholar]
- Sewell C. M., Clarridge J. E., Young E. J., Guthrie R. K. Clinical significance of coagulase-negative staphylococci. J Clin Microbiol. 1982 Aug;16(2):236–239. doi: 10.1128/jcm.16.2.236-239.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Watts J. L., Owens W. E., Nickerson S. C. Evaluation of the Minitek gram-positive set for identification of staphylococci isolated from the bovine mammary gland. J Clin Microbiol. 1986 May;23(5):873–875. doi: 10.1128/jcm.23.5.873-875.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wilson P. D., Jr, Salvati E. A., Aglietti P., Kutner L. J. The problem of infection in endoprosthetic surgery of the hip joint. Clin Orthop Relat Res. 1973 Oct;(96):213–221. [PubMed] [Google Scholar]