Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1987 Nov;25(11):2221–2222. doi: 10.1128/jcm.25.11.2221-2222.1987

Comparison of conventional and revised isolator blood culture tubes.

B A Basille 1, K A Easley 1, G S Hall 1, J A Washington 2nd 1
PMCID: PMC269448  PMID: 3320091

Abstract

A paired clinical study compared bacterial and fungal recovery from 4,553 blood cultures processed by the conventional Isolator (Du Pont Co.) and a revised Isolator consisting of a single-stoppered, round-bottom tube containing the same ingredients as the conventional tube except for an inert fluorochemical. Excluding contaminants, there were 425 positive blood cultures with 450 isolates representing 208 patients. There were no statistically significant differences between systems in the number of positive cultures or patients with positive cultures for each organism group studied, nor were there any statistically significant differences between systems in the time required for detection of positive cultures.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bille J., Stockman L., Roberts G. D., Horstmeier C. D., Ilstrup D. M. Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood. J Clin Microbiol. 1983 Sep;18(3):469–471. doi: 10.1128/jcm.18.3.469-471.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Henry N. K., McLimans C. A., Wright A. J., Thompson R. L., Wilson W. R., Washington J. A., 2nd Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube. J Clin Microbiol. 1983 May;17(5):864–869. doi: 10.1128/jcm.17.5.864-869.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Kelly M. T., Fojtasek M. F., Abbott T. M., Hale D. C., Dizikes J. R., Boshard R., Buck G. E., Martin W. J., Matsen J. M. Clinical evaluation of a lysis-centrifugation technique for the detection of septicemia. JAMA. 1983 Oct 28;250(16):2185–2188. [PubMed] [Google Scholar]
  4. Kiehn T. E., Gold J. W., Brannon P., Timberger R. J., Armstrong D. Mycobacterium tuberculosis bacteremia detected by the Isolator lysis-centrifugation blood culture system. J Clin Microbiol. 1985 Apr;21(4):647–648. doi: 10.1128/jcm.21.4.647-648.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)