Abstract
To help prevent pyrogenic reactions and bacteremia in hemodialysis patients, the Association for the Advancement of Medical Instrumentation and the Centers for Disease Control recommend microbiologic assay of hemodialysis fluids at least monthly. Five commercially available assay systems were evaluated by using the membrane filtration technique with standard methods agar and trypticase soy agar as the standards for comparison. Each assay system was challenged with dialysate and reverse-osmosis water from local dialysis centers, aqueous suspensions of eight laboratory strains of gram-negative bacilli and nontuberculous mycobacteria, and a mixed microbial flora inoculated into reverse-osmosis water and laboratory-prepared dialysate. Mean viable counts from triplicate samples were obtained after incubation at 37 degrees C for up to 72 h. The efficiency of recovery varied with the specific type of microbial challenge. The SPC water sampler (Millipore Corp., Bedford, Mass.) was the most consistent in obtaining the highest viable counts. Other commercial systems were comparable to each other in overall performance. All assay systems tested provided an acceptable balance between microbial recovery and required sampling time, equipment, and expertise.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Alter M. J., Favero M. S., Miller J. K., Coleman P. J., Bland L. A. Reuse of hemodialyzers. Results of nationwide surveillance for adverse effects. JAMA. 1988 Oct 14;260(14):2073–2076. doi: 10.1001/jama.260.14.2073. [DOI] [PubMed] [Google Scholar]
- Beck-Sague C. M., Jarvis W. R., Bland L. A., Arduino M. J., Aguero S. M., Verosic G. Outbreak of gram-negative bacteremia and pyrogenic reactions in a hemodialysis center. Am J Nephrol. 1990;10(5):397–403. doi: 10.1159/000168155. [DOI] [PubMed] [Google Scholar]
- Bland L. A., Ridgeway M. R., Aguero S. M., Carson L. A., Favero M. S. Potential bacteriologic and endotoxin hazards associated with liquid bicarbonate concentrate. ASAIO Trans. 1987 Jul-Sep;33(3):542–545. [PubMed] [Google Scholar]
- Favero M. S., Petersen N. J., Boyer K. M., Carson L. A., Bond W. W. Microbial contamination of renal dialysis systems and associated health risks. Trans Am Soc Artif Intern Organs. 1974;20A:175–183. [PubMed] [Google Scholar]
- Favero M. S., Petersen N. J., Carson L. A., Bond W. W., Hindman S. H. Gram-negative water bacteria in hemodialysis systems. Health Lab Sci. 1975 Oct;12(4):321–334. [PubMed] [Google Scholar]
- Hindman S. H., Favero M. S., Carson L. A., Petersen N. J., Schonberger L. B., Solano J. T. Pyrogenic reactions during haemodialysis caused by extramural endotoxin. Lancet. 1975 Oct 18;2(7938):732–734. doi: 10.1016/s0140-6736(75)90721-7. [DOI] [PubMed] [Google Scholar]
- Lowry P. W., Beck-Sague C. M., Bland L. A., Aguero S. M., Arduino M. J., Minuth A. N., Murray R. A., Swenson J. M., Jarvis W. R. Mycobacterium chelonae infection among patients receiving high-flux dialysis in a hemodialysis clinic in California. J Infect Dis. 1990 Jan;161(1):85–90. doi: 10.1093/infdis/161.1.85. [DOI] [PubMed] [Google Scholar]
- Raij L., Shapiro F. L., Michael A. F. Endotoxemia in febrile reactions during hemodialysis. Kidney Int. 1973 Jul;4(1):57–60. doi: 10.1038/ki.1973.79. [DOI] [PubMed] [Google Scholar]