Abstract
A new latex agglutination test for rubella virus was used to test sera with a hemagglutination inhibition titer of less than or equal to 8 (97 specimens) or greater than or equal to 256 (158 specimens). Maximum latex agglutination test sensitivity was achieved when low-titer sera were tested undiluted and high-titer sera were diluted (1:10). A modification of the protocol of the manufacturer resulted in a latex agglutination-hemagglutination inhibition agreement of 96.7%.
Full text
PDF

Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Castellano G. A., Madden D. L., Hazzard G. T., Cleghorn C. S., Vails D. V., Ley A. C., Tzan N. R., Sever J. L. Evaluation of commercially available diagnostic test kits for rubella. J Infect Dis. 1981 Apr;143(4):578–584. doi: 10.1093/infdis/143.4.578. [DOI] [PubMed] [Google Scholar]
- Kalimo K. O., Meurman O. H., Halonen P. E., Ziola B. R., Viljanen M. K., Granfors K., Toivanen P. Solid-phase radioimmunoassay of rubella virus immunoglobulin G and immunoglobulin M antibodies. J Clin Microbiol. 1976 Aug;4(2):117–123. doi: 10.1128/jcm.4.2.117-123.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Meegan J. M., Evans B. K., Horstmann D. M. Comparison of the latex agglutination test with the hemagglutination inhibition test, enzyme-linked immunosorbent assay, and neutralization test for detection of antibodies to rubella virus. J Clin Microbiol. 1982 Oct;16(4):644–649. doi: 10.1128/jcm.16.4.644-649.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Morgan-Capner P., Pullen H. J., Pattison J. R., Bidwell D. E., Bartlett A., Voller A. A comparison of three tests for rubella antibody screening. J Clin Pathol. 1979 Jun;32(6):542–545. doi: 10.1136/jcp.32.6.542. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Shekarchi I. C., Sever J. L., Tzan N., Ley A., Ward L. C., Madden D. Comparison of hemagglutination inhibition test and enzyme-linked immunosorbent assay for determining antibody to rubella virus. J Clin Microbiol. 1981 May;13(5):850–854. doi: 10.1128/jcm.13.5.850-854.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weissfeld A. S., Sonnenwirth A. C. New latex agglutination test for rapid determination of rubella immune status. J Clin Microbiol. 1982 Nov;16(5):971–972. doi: 10.1128/jcm.16.5.971-972.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zartarian M. V., Friedly G., Peterson E. M., de la Maza L. M. Detection of rubella antibodies by hemagglutination inhibition, indirect fluorescent-antibody test, and enzyme-linked immunosorbent assay. J Clin Microbiol. 1981 Dec;14(6):640–645. doi: 10.1128/jcm.14.6.640-645.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]