Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1984 Feb;19(2):97–99. doi: 10.1128/jcm.19.2.97-99.1984

Contamination of cultures processed with the isolator lysis-centrifugation blood culture tube.

R B Thomson Jr, S J Vanzo, N K Henry, K L Guenther, J A Washington 2nd
PMCID: PMC270994  PMID: 6365968

Abstract

Overall contamination (on- plus off-streak) of the Isolator (Du Pont Co.) blood culture tube (23%) was greater than that of a conventional broth blood culture bottle (0.6%) or that of a biphasic blood culture bottle (1.3%). To determine the source of this contamination, Isolator cultures of blood from 59 healthy volunteers and of sterile broth from 60 vials were made. A total of 37% of the blood cultures and 22% of the broth cultures were contaminated (P = 0.06). Staphylococcus epidermidis-contaminated cultures represented 31 and 10% of the blood and broth cultures, respectively (P = 0.06). Contamination of plates processed on a bench top, in front of horizontal laminar flow, and in a biological safety cabinet with vertical laminar flow were compared. Processing plates in a biological safety cabinet resulted in a significant reduction in the number of contaminated plates (P less than 0.05). The contamination rate for 7,874 Isolator blood cultures processed in the biological safety cabinet was significantly decreased to 6.7% on-streak (9.3% on- plus off-streak). Contamination of Isolator-processed blood cultures originated from the laboratory and the patient. The former can be reduced by inoculating plates in a vertical laminar flow biological safety cabinet and by maintaining adequate quality control of media. The latter may be unavoidable.

Full text

PDF
97

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Dorn G. L., Land G. A., Wilson G. E. Improved blood culture technique based on centrifugation: clinical evaluation. J Clin Microbiol. 1979 Mar;9(3):391–396. doi: 10.1128/jcm.9.3.391-396.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Henry N. K., McLimans C. A., Wright A. J., Thompson R. L., Wilson W. R., Washington J. A., 2nd Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube. J Clin Microbiol. 1983 May;17(5):864–869. doi: 10.1128/jcm.17.5.864-869.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Zierdt C. H. Evidence for transient Staphylococcus epidermidis bacteremia in patients and in healthy humans. J Clin Microbiol. 1983 Apr;17(4):628–630. doi: 10.1128/jcm.17.4.628-630.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES