Abstract
The API STAPHase (Analytab Products, Inc., Plainview, N.Y.) and SeroSTAT Staph (Scott Laboratories, Fiskville, R.I.) tests were compared to the conventional tube coagulase test and a slide coagulase test by using fresh isolates of members of the family Micrococcaceae. The 4-h, 24-h, and combined readings of the tube coagulase test detected 94.5, 99.5 and 100%, respectively, of 219 Staphylococcus aureus isolates. The API STAPHase, SeroSTAT Staph, and slide coagulase tests detected 95.9, 95.4 and 95.9% of the isolates of S. aureus, respectively. There were no false-positive results with any of the systems when tested with 103 strains of members of the family Micrococcaceae other than S. aureus. We concluded that the STAPHase and SeroSTAT Staph tests were equal in accuracy to the slide coagulase and 4-h tube coagulase tests and were suitable for use in the clinical microbiology laboratory. However, SeroSTAT Staph gave faster results than the API STAPHase, and the test was easier to perform. Also, the false-negative rate was high enough with the STAPHase, SeroSTAT Staph, and the slide coagulase tests that all negative reactions should be confirmed with a tube test.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- DUTHIE E. S. Evidence for two forms of staphylococcal coagulase. J Gen Microbiol. 1954 Jun;10(3):427–436. doi: 10.1099/00221287-10-3-427. [DOI] [PubMed] [Google Scholar]
- Doern G. V. Evaluation of a commercial latex agglutination test for identification of Staphylococcus aureus. J Clin Microbiol. 1982 Mar;15(3):416–418. doi: 10.1128/jcm.15.3.416-418.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Essers L., Radebold K. Rapid and reliable identification of Staphylococcus aureus by a latex agglutination test. J Clin Microbiol. 1980 Nov;12(5):641–643. doi: 10.1128/jcm.12.5.641-643.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Goldstein J., Roberts J. W. Microtube coagulase test for detection of coagulase-positive staphylococci. J Clin Microbiol. 1982 May;15(5):848–851. doi: 10.1128/jcm.15.5.848-851.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Myrick B. A., Ellner P. D. Evaluation of the latex slide agglutination test for identification of Staphylococcus aureus. J Clin Microbiol. 1982 Feb;15(2):275–277. doi: 10.1128/jcm.15.2.275-277.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Phillips W. E., Jr, Kloos W. E. Identification of coagulase-positive Staphylococcus intermedius and Staphylococcus hyicus subsp. hyicus isolates from veterinary clinical specimens. J Clin Microbiol. 1981 Dec;14(6):671–673. doi: 10.1128/jcm.14.6.671-673.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- TURNER F. J., SCHWARTZ B. S. The use of a lyophilized human plasma standardized for blood coagulation factors in the coagulase and fibrinolytic tests. J Lab Clin Med. 1958 Dec;52(6):888–894. [PubMed] [Google Scholar]
- Zarzour J. Y., Belle E. A. Evaluation of three test procedures for identification of Staphylococcus aureus from clinical sources. J Clin Microbiol. 1978 Feb;7(2):133–136. doi: 10.1128/jcm.7.2.133-136.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]