Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1984 Jun;19(6):849–852. doi: 10.1128/jcm.19.6.849-852.1984

Evaluation of the hemagglutination treponemal test for syphilis.

N P Moyer, J D Hudson, W J Hausler Jr
PMCID: PMC271197  PMID: 6381525

Abstract

The sensitivity and specificity of the hemagglutination treponemal test for syphilis (HATTS) was compared with the fluorescent treponemal antibody-absorption test (FTA-ABS) with 491 sera. Medical histories were obtained for 153 patients with seroreactivity in either treponemal test. Overall correlation with patient history was 96.7% for the FTA-ABS and 93.9% for the HATTS. False-negative HATTS occurred in primary, late-latent (greater than 2 years), and treated syphilis. The reproducibility of the HATTS and FTA-ABS is equivalent. HATTS is an acceptable treponemal confirmatory test for syphilis, but the FTA-ABS should be used to resolve diagnostic discrepancies.

Full text

PDF
849

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Friedly G., Zartarian M. V., Wood J. C., Floyd C. M., Peterson E. M., de la Maza L. M. Hemagglutination treponemal test for syphilis. J Clin Microbiol. 1983 Oct;18(4):775–778. doi: 10.1128/jcm.18.4.775-778.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Hambie E. A., Larsen S. A., Perryman M. W., Pettit D. E., Feeley J. C. Heated versus unheated sera in the hemagglutination treponemal test for syphilis. J Clin Microbiol. 1982 Feb;15(2):337–338. doi: 10.1128/jcm.15.2.337-338.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Larsen S. A., Hambie E. A., Pettit D. E., Perryman M. W., Kraus S. J. Specificity, sensitivity, and reproducibility among the fluorescent treponemal antibody-absorption test, the microhemagglutination assay for Treponema pallidum antibodies, and the hemagglutination treponemal test for syphilis. J Clin Microbiol. 1981 Oct;14(4):441–445. doi: 10.1128/jcm.14.4.441-445.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Peter C. R., Thompson M. A., Wilson D. L. False-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests. J Clin Microbiol. 1979 Mar;9(3):369–372. doi: 10.1128/jcm.9.3.369-372.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Wentworth B. B., Thompson M. A., Peter C. R., Bawdon R. E., Wilson D. L. Comparison of a hemagglutination treponemal test for syphilis (HATTS) with other serologic methods for the diagnosis of syphilis. Sex Transm Dis. 1978 Jul-Sep;5(3):103–114. doi: 10.1097/00007435-197807000-00005. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES