Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1984 Sep;20(3):434–437. doi: 10.1128/jcm.20.3.434-437.1984

Interlaboratory comparison of the toluidine red unheated serum test antigen preparation.

C E Parham, D E Pettit, S A Larsen, E A Hambie, M W Perryman, B E McGrew
PMCID: PMC271345  PMID: 6386860

Abstract

The toluidine red unheated serum test (TRUST) antigen, a macroscopic flocculation test antigen developed by Pettit et al. (J. Clin. Microbiol. 18:1141-1145, 1983) by modifying the color-coded antigen of Kasatiya and Lambert (Appl. Microbiol. 28:317-318, 1974), was compared with the Venereal Disease Research Laboratory (VDRL) slide and rapid plasma reagin (RPR) 18-mm circle card tests for sensitivity, specificity, and reproducibility. Two lots of TRUST antigen were prepared by two laboratories in the Centers for Disease Control. Both laboratories performed the TRUST and VDRL slide test on serum samples from 1,102 patients attending the DeKalb County, Georgia, Sexually Transmitted Disease Clinic. In addition, one laboratory performed the RPR card test. Reactive sera were quantitated in the three nontreponemal tests and confirmed with the fluorescent treponemal antibody absorption test. The sensitivity in untreated syphilis for all nontreponemal tests involved was 98.4%. The specificity for these tests was 98.6%. The qualitative reproducibility among the four lots of TRUST antigen, VDRL slide, and RPR card tests was 98.2%. Only 20 sera showed discrepant results. Intralaboratory reproducibility of the two TRUST antigens was 100% for one laboratory and 99.6% for the other. Interlaboratory reproducibility for the four lots of TRUST and the VDRL slide test was 99%. Quantitative agreement +/- 1 dilution between the TRUST and RPR card test was 92.3%, and quantitative agreement +/- 1 dilution for the TRUST and RPR card test versus the VDRL slide test averaged 50%. The TRUST appeared to be comparable to the RPR card test in all parameters compared.

Full text

PDF
434

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Kasatiya S. S., Lambert N. G. Color-coded antigen for the automated reagin test for syphilis. Appl Microbiol. 1974 Aug;28(2):317–318. doi: 10.1128/am.28.2.317-318.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Pettit D. E., Larsen S. A., Harbec P. S., Feeley J. C., Parham C. E., Cruce D. D., Hambie E. A., Perryman M. W. Toluidine red unheated serum test, a nontreponemal test for syphilis. J Clin Microbiol. 1983 Nov;18(5):1141–1145. doi: 10.1128/jcm.18.5.1141-1145.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES