Abstract
This study evaluated the ability of the Rapid NFT system (API System SA, Montalieu-Vercieu, France) to accurately identify 262 clinically isolated, gram-negative, nonfermentative rods without additional tests. Identifications were classified as correct; low discrimination, with a spectrum of two or more possibilities (additional tests necessary for accurate identification); and incorrect. Correct identification rates were analyzed in two categories: (i) correct to species or biotype for all organism groups except Alcaligenes faecalis-odorans, Moraxella, Pseudomonas testosteroni-alcaligenes-pseudoalcaligenes, and Acinetobacter calcoaceticus biotype haemolyticus-alcaligenes (in this category, the latter four genus-biotype group identifications were taken as correct) and (ii) correct to species or biotype in all cases, including the above four groups. In category i, 87.4% of the strains were correctly identified, with 4.2% low discrimination and 8.4% incorrect. When the criteria of category ii were used, 71.8% of the strains were correctly identified, with 19.9% low discrimination. The Rapid NFT system provided excellent species identification of Pseudomonas and Flavobacterium spp., Bordetella bronchiseptica, and Achromobacter xylosoxidans strains. Within Acinetobacter calcoaceticus, differentiation between biotypes anitratus and lwoffi was satisfactory, but the system did not differentiate between biotypes haemolyticus and alcaligenes. Species resolution within the genera Moraxella and Alcaligenes was incomplete. All Alcaligenes faecalis strains were misidentified and accounted for 50% of misidentifications with the Rapid NFT system; however, these results may reflect taxonomic differences rather than true misidentifications. The Rapid NFT system is easy to inoculate and interpret and represents a worthwhile advance in the identification of gram-negative, nonfermentative rods.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Appelbaum P. C., Stavitz J., Bentz M. S., von Kuster L. C. Four methods for identification of gram-negative nonfermenting rods: organisms more commonly encountered in clinical specimens. J Clin Microbiol. 1980 Aug;12(2):271–278. doi: 10.1128/jcm.12.2.271-278.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Barnishan J., Ayers L. W. Rapid identification of nonfermentative gram-negative rods by the Corning N/F system. J Clin Microbiol. 1979 Feb;9(2):239–243. doi: 10.1128/jcm.9.2.239-243.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Burdash N. M., Bannister E. R., Manos J. P., West M. E. A comparison of four commercial systems for the identification of nonfermentative gram-negative bacilli. Am J Clin Pathol. 1980 Apr;73(4):564–569. doi: 10.1093/ajcp/73.4.564. [DOI] [PubMed] [Google Scholar]
- Chester V., Cleary T. J. Evaluation of the Minitek system for identification of nonfermentative and nonenteric fermentative Gram-negative bacteria. J Clin Microbiol. 1980 Oct;12(4):509–516. doi: 10.1128/jcm.12.4.509-516.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dowda H. Evaluation of two rapid methods for identification of commonly encountered nonfermenting or oxidase-positive, Gram-negative rods. J Clin Microbiol. 1977 Dec;6(6):605–609. doi: 10.1128/jcm.6.6.605-609.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hofherr L., Votava H., Blazevic D. J. Comparison of three methods for identifying nonfermenting gram-negative rods. Can J Microbiol. 1978 Oct;24(10):1140–1144. doi: 10.1139/m78-186. [DOI] [PubMed] [Google Scholar]
- Isenberg H. D., Sampson-Scherer J. Clinical laboratory evaluation of a system approach to the recognition of nonfermentative or oxidase-producing gram-negative, rod-shaped bacteria. J Clin Microbiol. 1977 Mar;5(3):336–340. doi: 10.1128/jcm.5.3.336-340.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Johnson J. E., Brinkley A. W. Comparison of the AutoMicrobic system and a conventional tube system for identification of nonfermentative and oxidase-positive gram-negative bacilli. J Clin Microbiol. 1982 Jan;15(1):25–27. doi: 10.1128/jcm.15.1.25-27.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kelly M. T., Matsen J. M., Morello J. A., Smith P. B., Tilton R. C. Collaborative clinical evaluation of the Autobac IDX system for identification of gram-negative bacilli. J Clin Microbiol. 1984 Apr;19(4):529–533. doi: 10.1128/jcm.19.4.529-533.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kiredjian M., Popoff M., Coynault C., Lefèvre M., Lemelin M. Taxonomie du genre Alcaligenes. Ann Microbiol (Paris) 1981 Nov-Dec;132 B(3):337–374. [PubMed] [Google Scholar]
- Koestenblatt E. K., Larone D. H., Pavletich K. J. Comparison of the Oxi/Ferm and N/F systems for identification of infrequently encountered nonfermentative and oxidase-positive fermentative bacilli. J Clin Microbiol. 1982 Mar;15(3):384–390. doi: 10.1128/jcm.15.3.384-390.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Morris M. J., Young V. M., Moody M. R. Evaluation of a multitest system for identification of saccharolytic pseudomonads. Am J Clin Pathol. 1978 Jan;69(1):41–47. doi: 10.1093/ajcp/69.1.41. [DOI] [PubMed] [Google Scholar]
- Nadler H., George H., Barr J. Accuracy and reproducibility of the Oxi/Ferm system in identifying a select group of unusual gram-negative bacilli. J Clin Microbiol. 1979 Feb;9(2):180–185. doi: 10.1128/jcm.9.2.180-185.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nord C. E., Wretlind B., Dahlbäck A. Evaluation of two test-kits--API and Oxi Ferm tube--for identification of oxidative-fermentative Gram-negative rods. Med Microbiol Immunol. 1977 Jul 18;163(2):93–97. doi: 10.1007/BF02121824. [DOI] [PubMed] [Google Scholar]
- Oberhofer T. R. Comparison of the API 20E and Oxi/Ferm systems in identification of nonfermentative and oxidase-positive fermentative bacteria. J Clin Microbiol. 1979 Feb;9(2):220–226. doi: 10.1128/jcm.9.2.220-226.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Oberhofer T. R., Rowen J. W., Cunningham G. F., Higbee J. W. Evaluation of the oxi/ferm tube system with selected Gram-negative bacteria. J Clin Microbiol. 1977 Dec;6(6):559–566. doi: 10.1128/jcm.6.6.559-566.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Shayegani M., Lee A. M., McLynn D. M. Evaluation of the Oxi/Ferm tube system for identification of nonfermentative Gram-negative bacilli. J Clin Microbiol. 1978 Jun;7(6):533–538. doi: 10.1128/jcm.7.6.533-538.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Shayegani M., Maupin P. S., McGlynn D. M. Evaluation of the API 20E system for identification of nonfermentative Gram-negative bacteria. J Clin Microbiol. 1978 Jun;7(6):539–545. doi: 10.1128/jcm.7.6.539-545.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Warwood N. M., Blazevic D. J., Hofherr L. Comparison of the API 20E and Corning N/F systems for identification of nonfermentative gram-negative rods. J Clin Microbiol. 1979 Aug;10(2):175–179. doi: 10.1128/jcm.10.2.175-179.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]