Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1984 Nov;20(5):884–886. doi: 10.1128/jcm.20.5.884-886.1984

Use of the directigen latex agglutination test for detection of Haemophilus influenzae, Streptococcus pneumoniae, and Neisseria meningitidis antigens in cerebrospinal fluid from meningitis patients.

J E Sippel, P A Hider, G Controni, K D Eisenach, H R Hill, M W Rytel, B L Wasilauskas
PMCID: PMC271466  PMID: 6439731

Abstract

Cerebrospinal fluid specimens from 257 persons were tested for the presence of bacterial antigens by counterimmunoelectrophoresis and the Directigen meningitis test (Hynson, Westcott & Dunning, Div. Becton Dickinson & Co., Baltimore, Md.). The specimens were obtained from 162 patients with meningitis caused by Haemophilus influenzae type b, Streptococcus pneumoniae, or Neisseria meningitidis serogroups A and C and from 95 patients without bacterial meningitis or meningitis caused by other bacterial agents. Directigen detected H. influenzae type b antigen in 83% (69 of 83) of the specimens obtained from patients with H. influenzae disease, pneumococcal antigen in 77% (30 of 39) of the specimens from patients with pneumococcal disease, and N. meningitidis antigen in 93% (37 of 40) of the specimens from patients with disease caused by N. meningitidis serogroups A and C. The comparable figures for counterimmunoelectrophoresis were 66% (55 of 83), 79% (31 of 39), and 78% (31 of 40), respectively. No false-positive reactions were reported with the Directigen reagents. Nonspecific reactions (agglutination with more than one of the four Directigen latex reagents) were noted with five specimens. The nonspecific reactions were resolved in four of the five specimens by heating (100 degrees C for 3 min). The accumulated data demonstrate that the sensitivity of the Directigen meningitis test is better than or at least equivalent to the sensitivity of counterimmunoelectrophoresis for the detection of antigens in cerebrospinal fluid.

Full text

PDF
884

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Colding H., Lind I. Counterimmunoelectrophoresis in the diagnosis of bacterial meningitis. J Clin Microbiol. 1977 Apr;5(4):405–409. doi: 10.1128/jcm.5.4.405-409.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Coonrod J. D., Rytel M. W. Determination of aetiology of bacterial meningitis by counter-immunoelectrophoresis. Lancet. 1972 May 27;1(7761):1154–1157. doi: 10.1016/s0140-6736(72)91376-1. [DOI] [PubMed] [Google Scholar]
  3. Edwards E. A., Muehl P. M., Peckinpaugh R. O. Diagnosis of bacterial meningitis by counterimmunoelectrophoresis. J Lab Clin Med. 1972 Sep;80(3):449–454. [PubMed] [Google Scholar]
  4. Finch C. A., Wilkinson H. W. Practical considerations in using counterimmunoelectrophoresis to identify the principal causative agents of bacterial meningitis. J Clin Microbiol. 1979 Oct;10(4):519–524. doi: 10.1128/jcm.10.4.519-524.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Ghanassia J. P., Slim A., Bergogne-Berezin E., Modai J. Failure of diagnosing group B meningococcal meningitis by immunoelectroosmophoresis. Scand J Infect Dis. 1977;9(4):313–314. doi: 10.3109/inf.1977.9.issue-4.12. [DOI] [PubMed] [Google Scholar]
  6. Greenwood B. M., Whittle H. C., Dominic-Rajkovic O. Counter-current immunoelectrophoresis in the diagnosis of meningococcal infections. Lancet. 1971 Sep 4;2(7723):519–521. doi: 10.1016/s0140-6736(71)90439-9. [DOI] [PubMed] [Google Scholar]
  7. Leinonen M., Käyhty H. Comparison of counter-current immunoelectrophoresis, latex agglutination, and radioimmunoassay in detection of soluble capsular polysaccharide antigens of Haemophilus influenzae type b and Neisseria meningitidis of groups A or C. J Clin Pathol. 1978 Dec;31(12):1172–1176. doi: 10.1136/jcp.31.12.1172. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Thirumoorthi M. C., Dajani A. S. Comparison of staphylococcal coagglutination, latex agglutination, and counterimmunoelectrophoresis for bacterial antigen detection. J Clin Microbiol. 1979 Jan;9(1):28–32. doi: 10.1128/jcm.9.1.28-32.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Ward J. I., Siber G. R., Scheifele D. W., Smith D. H. Rapid diagnosis of Hemophilus influenzae type b infections by latex particle agglutination and counterimmunoelectrophoresis. J Pediatr. 1978 Jul;93(1):37–42. doi: 10.1016/s0022-3476(78)80596-4. [DOI] [PubMed] [Google Scholar]
  10. Welch D. F., Hensel D. Evaluation of Bactogen and Phadebact for detection of Haemophilus influenzae type b antigen in cerebrospinal fluid. J Clin Microbiol. 1982 Nov;16(5):905–908. doi: 10.1128/jcm.16.5.905-908.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)