Rapid, colorimetric method for the detection of microorganisms in blood culture.

C Wallis, J L Melnick
PMCID: PMC271706  PMID: 3886687

Abstract

A semiautomated instrument (Septi-Screen) and method are described that semiquantify bacteria colorimetrically in blood-inoculated cultures in 2 to 8 h. If the blood culture is positive, concentrates (of viable bacteria) are obtained free of blood cells. In pediatric cases and in septicemia attributed to indwelling catheters where bacteremia is often manifested by high bacterial counts, the total time required to obtain bacterial concentrates is only 2 to 3 h. In brief, at various intervals after inoculation of 10 ml of blood into 100 ml of culture fluid, 25-ml blood culture samples are passed through the Septi-Filter. Erythrocytes and leukocytes pass into the filtrate and are discarded, but bacteria are electrostatically retained on the filter surface. The entrapped bacteria are backflushed and recovered as a concentrate that is processed through a second filter (Septi-Count) for colorimetric quantitation. The bacteria are stained, and the filter fibers are decolorized. The color intensity of the filter surface is proportional to the number of bacteria in the concentrate processed. The total Septi-Screen processing time is 3 to 5 min.

Full text

PDF
505

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. DeLand F., Wagner H. N., Jr Automated radiometric detection of bacterial growth in blood cultures. J Lab Clin Med. 1970 Mar;75(3):529–534. [PubMed] [Google Scholar]
  2. Dorn G. L., Haynes J. R., Burson G. G. Blood culture technique based on centrifugation: developmental phase. J Clin Microbiol. 1976 Mar;3(3):251–257. doi: 10.1128/jcm.3.3.251-257.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Kagan R. L., Schuette W. H., Zierdt C. H., MacLowry J. D. Rapid automated disgnosis of bacteremia by impedance detection. J Clin Microbiol. 1977 Jan;5(1):51–57. doi: 10.1128/jcm.5.1.51-57.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. McCarthy L. R., Senne J. E. Evaluation of acridine orange stain for detection of microorganisms in blood cultures. J Clin Microbiol. 1980 Mar;11(3):281–285. doi: 10.1128/jcm.11.3.281-285.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Raucher H. S., Hyatt A. C., Barzilai A., Harris M. B., Weiner M. A., LeLeiko N. S., Hodes D. S. Quantitative blood cultures in the evaluation of septicemia in children with Broviac catheters. J Pediatr. 1984 Jan;104(1):29–33. doi: 10.1016/s0022-3476(84)80584-3. [DOI] [PubMed] [Google Scholar]
  6. Sage B. H., Jr, Neece V. R. Rapid visual detection of microorganisms in blood culture. J Clin Microbiol. 1984 Jul;20(1):5–8. doi: 10.1128/jcm.20.1.5-8.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Wallis C., Melnick J. L., Longoria C. J. Colorimetric method for rapid determination of bacteriuria. J Clin Microbiol. 1981 Sep;14(3):342–346. doi: 10.1128/jcm.14.3.342-346.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Wallis C., Melnick J. L. Reverse-flow apparatus for enhanced colorimetric detection of bacteriuria. J Clin Microbiol. 1984 Nov;20(5):942–944. doi: 10.1128/jcm.20.5.942-944.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Wallis C., Melnick J. L., Wende R. D., Riely P. E. Rapid isolation of bacteria from septicemic patients by use of an antimicrobial agent removal device. J Clin Microbiol. 1980 May;11(5):462–464. doi: 10.1128/jcm.11.5.462-464.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)