BACKGROUND
Chronic obstructive pulmonary disease (COPD) is currently the 12th leading cause of disability in the world and is predicted to be 5th by the year 2020 (1). In the United States alone, it has been estimated that the annual cost of morbidity and early mortality due to COPD is approximately 4.7 billion dollars (2). COPD is a complex condition in which environmental factors interact with genetic susceptibility to cause disease. Tobacco smoke is the most important environmental risk factor, and in susceptible individuals it causes an exaggerated inflammatory response that ultimately destroys the lung parenchyma (emphysema) and/or increases airway resistance by remodeling of the airway wall (3). It has long been known that the pathway varies between individuals; some patients have predominant emphysema while others can have similar degrees of airflow obstruction due to severe small airway disease with relatively preserved parenchyma, but the proportion and contribution of each to the pathogenesis of disease is still unknown. Even though recent research has advanced our understanding of COPD pathogenesis, leading to the identification of potential targets and pathways for drug development, there are still major difficulties in conducting clinical trials designed to evaluate the benefits of new drug treatment for several reasons. These reasons include (1) the lack of validated short- and intermediate-term endpoints (or surrogates) that are predictive of future hard clinical outcomes, and (2) the lack of a method to provide precise phenotypes suitable for large-scale studies. It is for these reasons that computed tomography (CT) has become such an important tool in COPD research. CT provides a noninvasive method to obtain images of the lung that look similar to anatomic assessment, and CT images themselves are densitometry maps of the lung. Therefore any change in the structure of the lung will change the densitometry of the lung and, therefore, the image. Virtually every clinical center in all regions of the world has access to a CT scanner, so it is thought that CT images should be quite easy to obtain and it should be easy to conduct large, meaningful clinical studies.
However, while CT is a powerful tool, it does have some limitations and caveats for general use in clinical studies. These limitations include disagreements on the best method to analyze the lung parenchyma, no definitive study using airway wall algorithms, exposure of subjects to ionizing radiation, and the use of improperly calibrated CT scanners.
In 2001 the Alpha-1 Foundation sponsored a workshop on the use of CT in longitudinal studies. That workshop resulted in recommendations on the use of CT to analyze the lung parenchyma, namely, the use of the lowest 15th percentile point of lung density (4). Since then there has been much debate surrounding CT analysis, and it was decided that another workshop was needed to readdress these issues. Specifically the workshop was designed to look at the use of CT for quantifying the lung parenchyma and the airway wall dimensions, and at how those methods could be applied to longitudinal studies and what drawbacks there may be in these approaches. This summary will only briefly discuss the broad concepts of these issues and deal specifically with the recommendations of the workshop.
CT STUDIES
The studies of lung parenchyma fall into three broad categories: (1) small cross-sectional studies conducted in a single institution, (2) large multi-institutional cross-sectional studies, and (3) longitudinal studies that may be either single-center or multicenter. Large multicenter studies are now becoming very popular as investigators try and use CT as a tool to phenotype individuals or to study disease progression or the effect of therapeutic interventions. There are, obviously, many factors to consider when designing studies that use CT, but the longitudinal multicenter studies are the most problematic because they include many different parameters that need to be standardized.
PARENCHYMAL ANALYSIS
The analysis of the lung parenchyma has essentially remained unchanged for 20 years. There are two features of the CT scan that are measured using quantitative methods: volume and the apparent X-ray attenuation. Volume is simply measured by separating, or segmenting, the lung from the surrounding chest wall and mediastinal structures. Once the lung is segmented, the computer is used to count the number of voxels within the lung and then multiply them by the voxel dimensions. The voxel dimensions in the X and Y plane are the field of view (FOV) divided by image matrix size (usually 512 × 512). The voxel dimension in the Z dimension is the slice thickness, or in the case of noncontiguous or “gapped” slices the distance between the two CT slices. Most lung segmentation algorithms are very robust at finding the lung, and there is uniform agreement that lung volume can be reliably and accurately estimated using CT scans. With the advent of MDCT scans, it is now possible to obtain contiguous thin slice images of the entire lung during a single breath-hold. This makes it possible to segment the individual lobes from each other so that in addition to lung volume it is now possible to obtain the volume of individual lobes (5–11). In the absence of contiguous thin slices, it may be still possible to manually segment the lobes by tracing the fissures using a cursor but this introduces a certain amount of error, although this is usually less than 10%.
The other metric that can be obtained from the CT scan is the apparent X-ray attenuation value. This value, measured in Hounsfield units (HU), gives an indication of the density of the lung, as the HU scale is directly proportional to density within the biological range. Using this HU scale, Müller and coworkers (12, 13) originally reported that the percentage of the lung CT voxels that were less dense than the threshold cut-off value of −910 HU on conventional thick slice CT scans correlated with the extent of emphysema measured on pathological specimens. This study was reported at about the same time as another investigation by Hayhurst and colleagues (14, 15) showed that the lowest 5th percentile of the frequency distribution of X-ray attenuation values correlated with pathology. Over the succeeding years CT scanners have evolved to create thin slice images, then images acquired helically and then by multi-detector row. The latter two techniques have stood the test of time even though the actual value of either the threshold cutoff or the percentile values have been modified. The most common threshold point in use today is −950 HU (16), even though more recent data suggests that for multi-detector CT scanners −960 HU would be a better cutoff value (17). The percentile value has undergone some modification as well, and now the most universally used is the lowest 15th percentile cutoff value (4, 18–25). Numerous studies have shown that these studies all give reasonable estimates of the extent of disease in cross-sectional studies (18–20, 22, 24, 26–32). It is in longitudinal studies that there is some disagreement in the literature as to the appropriate method to use.
In longitudinal studies the CT scanner on which the images have been acquired, including both scanner manufacturer as well as the type of scanner used (how many detectors used), and the exposure of the scanner (kVp, mA), are of critical importance. Studies have shown that changing the image reconstruction algorithm can greatly influence the extent of emphysema measured using the threshold cutoff value (33, 34). Furthermore, studies have also shown that changing the X-ray dose of the CT scan can influence the extent of emphysema measured using the threshold approach (35). Therefore, it is important in either cross-sectional studies or longitudinal studies that CT technique is held constant for all parameters, slice thickness, reconstruction algorithm, and X-ray dose. Another group of factors include subject characteristics, including body size and, most importantly, the size of breath that the subject took during the scan. Lung volume CT scanning is an important characteristic to take into account, and there have been methods proposed to try and compensate for this, including spirometrically gating the CT scan or using a mathematical approach to correct for lung volume (18, 32, 36). Spirometrical gating has proven to be problematic and is likely not practical in large multicenter studies; therefore, it has been recommended that a mathematical adjustment of lung volume be applied in all longitudinal studies (18, 19).
AIRWAY ANALYSIS
Airway analysis is the most complex analysis that is in common use today (6, 7, 37–56). Unfortunately, there are almost as many different algorithms in use as there are centers that are use them. New multi-detector CT scanners can now acquire images with near isotropic voxel resolution within a single breath-hold. However, this type of image acquisition requires 0.5-mm slice thickness and, therefore, a CT scanner with a minimum of 64 detectors. While there is and has been much work done on developing the best algorithm to measure airways dimensions, distal airways that are responsible for the airflow limitation in COPD are below the resolution of the CT scanner. Two studies have examined this problem. Using the two-dimensional approach on trans-axial CT scans, Nakano and coworkers (50) showed that the wall thickness in the small airways, measured using histology, was correlated with the wall area in the intermediate sized airways measured with CT. Another study by Hasegawa and colleagues (56) using three-dimensional reconstructions of the airway walls showed that airway wall dimensions in the smallest airways that were measureable (i.e., 6th generation) had the strongest correlation with FEV1 compared with larger segmental (3rd generation) airways. These data have given investigators hope that airway measurements obtained using CT will provide useful data in the understanding of COPD.
As mentioned briefly above, there are numerous limitations to the use of CT scanning to measure airways. The first and obvious limitation is the resolution of the CT scanner. In usual clinical CT scanning, the field of view limits the pixel size to approximately 0.5 mm in the X and Y dimension. Furthermore, until the recent advent of multi-slice CT scanners that can acquire images with 0.5-mm slice thickness, the CT slice thickness has limited the Z dimension to 1 mm. This means that the airways that are responsible for airflow limitation are below the resolution of the CT scanner. Second, there are no definitive data on the best algorithm to measure the airway wall. While a great deal of research has gone into airway wall algorithms (6, 7, 37, 40, 50, 54–57), there is no clear indication that one algorithm provides more useful data than another one. Third, the analysis of airways using three-dimensional algorithms is still in its infancy and definitive data are still lacking in this area. An obvious problem of the three-dimensional approach is that there are now many airways that can be “named,” and investigators do not know how many airways or how many airway paths to measure. It should also be noted that there are very few longitudinal studies of airways. Longitudinal analysis of airways is very problematic because the effect of CT image acquisition parameters such as X-ray dose, subject position, and volume of inspiration (to name a few) is completely unknown. It is likely that the size of breath the subject takes will produce very different CT images of the airway tree, thereby affecting all of the data derived from the images. Airway analysis still has a long way to go before it becomes practical in the clinical setting. As such, it remains in the research domain and is limited in its applicability.
X-RAY DOSE
A thorough review of X-ray dose can be found in numerous reviews, including the ones found in the articles in this issue. However, an important feature to bear in mind is that X-ray dose is directly related to the mA setting of the CT scanner (58). While the actual effects of radiation on subjects is still unknown, it is the recommendation that the lowest possible dose be used. The level of radiation dose that can be used is dependent on the age of the subject: the younger the subject, the less the dose that should be used (58, 59). Because image noise within the CT scan is also dependent on the dose of the scan, questions involving the lung parenchyma may be answered using a very low radiation dose while airway analysis may require a higher dose (35, 59).
CONCLUSIONS AND RECOMMENDATIONS
Quantitative CT scanning will provide useful data on the lung structure that is responsible for the changes in lung function that define COPD. These structural data are extremely important for understanding both pathogenesis and the effect of therapeutic interventions. As such, it is the recommendation of this workshop that in cross-sectional studies of COPD either the threshold cutoff analysis or the percentile point analysis can be used, as either provides useful information about the extent of emphysema. For longitudinal studies it was recommended that the volume-corrected percentile approach be used because this approach is less sensitive to minor changes in the technical aspects of the CT scan (image noise caused by CT scanner, reconstruction algorithm, etc.) and more sensitive to changes in lung structure. Volume analysis of the lung has proven to be very robust across many different CT platforms and image analysis algorithms, so the volume measurements are strongly recommended not only for correction of the density data but for studies that require information on lung or lobar volume changes.
Airway analysis is extremely interesting, and there are numerous groups actively pursuing this approach. However, this technique is rife with technical and methodological problems that still limit it to the research category, and the workshop was unable to define a statement beyond this point.
The CT scanner must be treated just like all measuring devices, and be properly calibrated and used without changing the features of the measuring device. This is especially important for longitudinal studies, in which a simple change in the X-ray dose or the reconstruction algorithm for the images can produce huge changes in the extent of emphysema being measured. Therefore the recommendation of this workshop is that very careful attention be paid to the acquisition of the CT images or none of the other recommendations will be of any use.
It is the recommendation of this workshop that the X-ray dose be kept as low as possible in all studies. This workshop was not able to define the definitive X-ray dose setting because that definition depends on the type of study being performed.
In conclusion, CT is a powerful tool for the analysis of COPD. There is much enthusiasm within the CT analysis community that CT can provide very robust and reliable measurements of lung structure. Some of these techniques, such as lung volume and density, are quite mature, but other techniques, such as airway analysis and special feature or “textural” analysis of the lung density, should still be considered in the research phase. However, this should not stop investigators from using these less mature techniques, but should encourage them to continue to develop and refine these techniques so that the anatomy of the lung can be accurately measured. The following articles provide some of the background for the standardization of CT scanning in COPD research in the future.
Acknowledgments
We would like to thank the Alpha-1 Foundation and the COPD Foundation for their financial and administrative support of this workshop. We would also like to thank Linda Rodriguez and Jamie Lamson for their organizational expertise.
Participants in the Workshop
Alpha-1 Foundation: John Walsh, Adam Wanner (University of Miami)
Chair: Harvey Coxson (University of British Columbia)
Co-Chairs: John Newell (National Jewish Health), Stephen Rennard (University of Nebraska), Jan Stolk (Leiden University Medical Center)
Participants: Alexander Bankier (Harvard Medical School), Mathew Brown (University of California, Los Angeles), Asgar Dirksen (University of Copenhagen), Raúl San José Estépar (Harvard Medical School), Michael Flynn (Henry Ford Hospital), Koos Geleijns (Leiden University Medical Center), Jonathan Goldin (University of California, Los Angeles), Eric Hoffman (University of Iowa), Jiang Hsieh (General Electric Healthcare), Ken Leader (University of Pittsburgh), Barry Make (National Jewish Health), Fernando Martinez (University of Michigan), John Mayo (University of British Columbia), Annette McWilliams (University of British Columbia), Michiaki Mishima (Kyoto University), Masaharu Nishimura (Hokkaido University), David Parr (University Hospital in Coventry), John Reilly (University of Pittsburgh), Martine Remy-Jardin (University Center of Lille), Sanjay Sharma (GlaxoSmithKline), Edwin Silverman (Harvard Medical School), Berend Stoel (Leiden University Medical Center), Jorgen Vestbo (University of Copenhagen), Peter Wagner (University of California, San Diego).
H.O.C. is a Canadian Institutes of Health Research/British Columbia Lung Association New Investigator and is funded in part by Pittsburgh COPD SCCOR NIH 1P50 HL084948 and R01 HL085096 from the National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD to the University of Pittsburgh.
Conflict of Interest Statement: H.O.C. received $11,000 in 2005 and $4,800 in 2006 and 2007 for serving on an Advisory Board for GlaxoSmithKline (GSK). In addition, he is the co-investigator on two multicenter studies sponsored by GSK and has received travel expenses to attend meetings related to the project. He has three contract service agreements with GSK to quantify the CT scans in subjects with COPD and a service agreement with Spiration, Inc. to measure changes in lung volume in subjects with severe emphysema. A percentage of his salary between 2003 and 2006 ($15,000/year) derives from contract funds provided to a colleague (Peter D. Pare) by GSK for the development of validated methods to measure emphysema and airway disease using CT. He is the co-investigator (with principal investigator D. Sin) on a Canadian Institutes of Health–Industry (Wyeth) partnership grant. There is no financial relationship between any industry and the current study.
References
- 1.Murray CJL, Lopez AD. Evidence-based health policy–lessons from the Global Burden of Disease Study. Science 1996;274:740–743. [DOI] [PubMed] [Google Scholar]
- 2.Rossi A, Confalonieri M. Burden of chronic obstructive pulmonary disease. Lancet 2000;356:s56. [DOI] [PubMed] [Google Scholar]
- 3.Pauwels RA, Buist AS, Calverley PM, Jenkins CR, Hurd SS. Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary. Am J Respir Crit Care Med 2001;163:1256–1276. [DOI] [PubMed] [Google Scholar]
- 4.Newell JD Jr, Hogg JC, Snider GL. Report of a workshop: quantitative computed tomography scanning in longitudinal studies of emphysema. Eur Respir J 2004;23:769–775. [DOI] [PubMed] [Google Scholar]
- 5.Zhang L, Hoffman EA, Reinhardt JM. Lung lobar segmentation by graph search with 3D shape constraints. Proc SPIE 2001;4321:204–215. [Google Scholar]
- 6.Montaudon M, Berger P, de Dietrich G, Braquelaire A, Marthan R, Tunon-de-Lara JM, Laurent F. Assessment of airways with three-dimensional quantitative thin-section CT: in vitro and in vivo validation. Radiology 2007;242:563–572. [DOI] [PubMed] [Google Scholar]
- 7.Tschirren J, Hoffman EA, McLennan G, Sonka M. Intrathoracic airway trees: segmentation and airway morphology analysis from low-dose CT scans. IEEE Trans Med Imaging 2005;24:1529–1539. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Hu S, Hoffman EA, Reinhardt JM. Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images. IEEE Trans Med Imaging 2001;20:490–498. [DOI] [PubMed] [Google Scholar]
- 9.Kuhnighk J, Hahn HK, Hindennach M, Dicken V, Krass S, Peitgen HO. Lung lobe segmentation by anatomy-guided 3D watershed transform. Proc SPIE 2003;5032:1484–1490. [Google Scholar]
- 10.Ukil S, Hoffman EA, Reinhardt JM. Automatic lung lobe segmentation in x-ray CT images by 3D watershed transform using anatomic information from the segmented airway treee. Proc SPIE 2005;5747:556–567. [Google Scholar]
- 11.Zhang L, Hoffman EA, Reinhardt JM. Altas-driven lung lobe segmentation in volumetric x-ray CT images. Proc SPIE 2003;25:1–16. [DOI] [PubMed] [Google Scholar]
- 12.Müller NL, Staples CA, Miller RR, Abboud RT. “Density mask”: an objective method to quantitate emphysema using computed tomography. Chest 1988;94:782–787. [DOI] [PubMed] [Google Scholar]
- 13.Miller RR, Müller NL, Vedal S, Morrison NJ, Staples CA. Limitations of computed tomography in the assessment of emphysema. Am Rev Respir Dis 1989;139:980–983. [DOI] [PubMed] [Google Scholar]
- 14.Hayhurst MD, Flenley DC, McLean A, Wightman AJA, MacNee W, Wright D, Lamb D, Best J. Diagnosis of pulmonary emphysema by computerized tomography. Lancet 1984;2:320–322. [DOI] [PubMed] [Google Scholar]
- 15.Gould GA, MacNee W, McLean A, Warren PM, Redpath A, Best JJ, Lamb D. CT measurements of lung density in life can quantitate distal airspace enlargement–an essential defining feature of human emphysema. Am Rev Respir Dis 1988;137:380–392. [DOI] [PubMed] [Google Scholar]
- 16.Gevenois PA, De Vuyst P, de Maertelaer V, Zanen J, Jacobovitz D, Cosio MG, Yernault JC. Comparison of computed density and microscopic morphometry in pulmonary emphysema. Am J Respir Crit Care Med 1996;154:187–192. [DOI] [PubMed] [Google Scholar]
- 17.Madani A, Zanen J, de Maertelaer V, Gevenois PA. Pulmonary emphysema: objective quantification at multi-detector row CT: comparison with macroscopic and microscopic morphometry. Radiology 2006;238:1036–1043. [DOI] [PubMed] [Google Scholar]
- 18.Shaker SB, Dirksen A, Laursen LC, Maltbaek N, Christensen L, Sander U, Seersholm N, Skovgaard LT, Nielsen L, Kok-Jensen A. Short-term reproducibility of computed tomography-based lung density measurements in alpha-1 antitrypsin deficiency and smokers with emphysema. Acta Radiol 2004;45:424–430. [DOI] [PubMed] [Google Scholar]
- 19.Stolk J, Dirksen A, van der Lugt AA, Hutsebaut J, Mathieu J, de Ree J, Reiber JH, Stoel BC. Repeatability of lung density measurements with low-dose computed tomography in subjects with alpha-1-antitrypsin deficiency-associated emphysema. Invest Radiol 2001;36:648–651. [DOI] [PubMed] [Google Scholar]
- 20.Stolk J, Ng WH, Bakker ME, Reiber JH, Rabe KF, Putter H, Stoel BC. Correlation between annual change in health status and computer tomography derived lung density in subjects with alpha1-antitrypsin deficiency. Thorax 2003;58:1027–1030. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Parr DG, Stoel BC, Stolk J, Nightingale PG, Stockley RA. Influence of calibration on densitometric studies of emphysema progression using computed tomography. Am J Respir Crit Care Med 2004;170:883–890. [DOI] [PubMed] [Google Scholar]
- 22.Parr DG, Stoel BC, Stolk J, Stockley RA. Pattern of emphysema distribution in alpha1-antitrypsin deficiency influences lung function impairment. Am J Respir Crit Care Med 2004;170:1172–1178. [DOI] [PubMed] [Google Scholar]
- 23.Dirksen A, Dijkman JH, Madsen IF, Stoel B, Hutchison DCS, Ulrik CS, Skovgaard LT, Kok-Jensen A, Rudolphus A, Seersholm N, et al. A randomized clinical trial of a-1 antitrypsin augmentation therapy. Am J Respir Crit Care Med 1999;160:1468–1472. [DOI] [PubMed] [Google Scholar]
- 24.Dirksen A, Friis M, Olesen KP, Skovgaard LT, Sorensen K. Progress of emphysema in severe a1-antitrypsin deficiency as assessed by annual CT. Acta Radiol 1997;38:826–832. [DOI] [PubMed] [Google Scholar]
- 25.Stoel BC, Bakker ME, Stolk J, Dirksen A, Stockley RA, Piitulainen E, Russi EW, Reiber JH. Comparison of the sensitivities of 5 different computed tomography scanners for the assessment of the progression of pulmonary emphysema: a phantom study. Invest Radiol 2004;39:1–7. [DOI] [PubMed] [Google Scholar]
- 26.Coxson HO, Chan IH, Mayo JR, Hlynsky J, Nakano Y, Birmingham CL. Early emphysema in patients with anorexia nervosa. Am J Respir Crit Care Med 2004;170:748–752. [DOI] [PubMed] [Google Scholar]
- 27.Coxson HO, Mayo JR, Behzad H, Moore BJ, Verburgt LM, Staples CA, Pare PD, Hogg JC. Measurement of lung expansion with computed tomography and comparison with quantitative histology. J Appl Physiol 1995;79:1525–1530. [DOI] [PubMed] [Google Scholar]
- 28.Coxson HO, Rogers RM, Whittall KP, D'Yachkova Y, Pare PD, Sciurba FC, Hogg JC. A quantification of the lung surface area in emphysema using computed tomography. Am J Respir Crit Care Med 1999;159:851–856. [DOI] [PubMed] [Google Scholar]
- 29.Coxson HO, Whittall KP, Nakano Y, Rogers RM, Sciurba FC, Keenan RJ, Hogg JC. Selection of patients for lung volume reduction surgery using a power law analysis of the computed tomographic scan. Thorax 2003;58:510–514. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.DeMeo DL, Hersh CP, Hoffman EA, Litonjua AA, Lazarus R, Sparrow D, Benditt JO, Criner G, Make B, Martinez FJ, et al. Genetic determinants of emphysema distribution in the national emphysema treatment trial. Am J Respir Crit Care Med 2007;176:42–48. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Stolk J, Versteegh MIM, Montenij LJ, Bakker ME, Grebski E, Tutic M, Wildermuth S, Weder W, el Bardiji M, Reiber JHC, et al. Densitometry for assessment of effect of lung volume reduction surgery for emphysema. Eur Respir J 2007;29:1075–1077. [DOI] [PubMed] [Google Scholar]
- 32.Zagers H, Vrooman HA, Aarts NJ, Stolk J, Schultze Kool LJ, Dijkman JH, Van Voorthuisen AE, Reiber JH. Assessment of the progression of emphysema by quantitative analysis of spirometrically gated computed tomography images. Invest Radiol 1996;31:761–767. [DOI] [PubMed] [Google Scholar]
- 33.Kemerink GJ, Kruize HH, Lamers RJS, van Engelshoven JMA. Density resolution in quantitative computed tomography of foam and lung. Med Phys 1996;23:1697–1708. [DOI] [PubMed] [Google Scholar]
- 34.Boedeker KL, McNitt-Gray MF, Rogers SR, Truong DA, Brown MS, Gjertson DW, Goldin JG. Emphysema: effect of reconstruction algorithm on CT imaging measures. Radiology 2004;232:295–301. [DOI] [PubMed] [Google Scholar]
- 35.Yuan R, Mayo JR, Hogg JC, Pare PD, McWilliams AM, Lam S, Coxson HO. The effects of radiation dose and CT manufacturer on measurements of lung densitometry. Chest 2007;132:617–623. [DOI] [PubMed] [Google Scholar]
- 36.Stoel BC, Vrooman HA, Stolk J, Reiber JH. Sources of error in lung densitometry with CT. Invest Radiol 1999;34:303–309. [DOI] [PubMed] [Google Scholar]
- 37.Brown MS, Goldin JG, McNitt-Gray MF, Greaser LE, Sapra A, Li KT, Sayre JW, Martin K, Aberle DR. Knowledge-based segmentation of thoracic computed tomography images for assessment of split lung function. Med Phys 2000;27:592–598. [DOI] [PubMed] [Google Scholar]
- 38.Chaturvedi A, Lee Z. Three-dimensional segmentation and skeletonization to build airway tree data structure for small animals. Phys Med Biol 2005;50:1405–1419. [DOI] [PubMed] [Google Scholar]
- 39.Ferretti GR, Vining DJ, Knoplioch J, Coulomb M. Tracheobronchial tree: three-dimensional spiral CT with bronchoscopic perspective. J Comput Assist Tomogr 1996;20:777–781. [DOI] [PubMed] [Google Scholar]
- 40.King GG, Muller NL, Pare PD. Evaluation of airways in obstructive pulmonary disease using high-resolution computed tomography. Am J Respir Crit Care Med 1999;159:992–1004. [DOI] [PubMed] [Google Scholar]
- 41.King GG, Muller NL, Whittall KP, Xiang QS, Pare PD. An analysis algorithm for measuring airway lumen and wall areas from high-resolution computed tomographic data. Am J Respir Crit Care Med 2000;161:574–580. [DOI] [PubMed] [Google Scholar]
- 42.Matsuoka S, Kurihara Y, Nakajima Y, Niimi H, Ashida H, Kaneoya K. Serial change in airway lumen and wall thickness at thin-section CT in asymptomatic subjects. Radiology 2005;234:595–603. [DOI] [PubMed] [Google Scholar]
- 43.Matsuoka S, Kurihara Y, Yagihashi K, Hoshino M, Nakajima Y. Airway dimensions at inspiratory and expiratory multisection CT in chronic obstructive pulmonary disease: correlation with airflow limitation. Radiology 2008;248:1042–1049. [DOI] [PubMed] [Google Scholar]
- 44.McNamara AE, Muller NL, Okazawa M, Arntorp J, Wiggs BR, Pare PD. Airway narrowing in excised canine lung measured by high-resolution computed tomography. J Appl Physiol 1992;73:307–316. [DOI] [PubMed] [Google Scholar]
- 45.McNitt-Gray MF, Goldin JG, Johnson TD, Tashkin DP, Aberle DR. Development and testing of image-processing methods for the quantitative assessment of airway hyperresponsiveness from high-resolution CT images. J Comput Assist Tomogr 1997;21:939–947. [DOI] [PubMed] [Google Scholar]
- 46.Mitchell AW, Wells AU, Hansell DM. Changes in cross-sectional area of the lungs on end expiratory computed tomography in normal individuals. Clin Radiol 1996;51:804–806. [DOI] [PubMed] [Google Scholar]
- 47.Montaudon M, Berger P, Cangini-Sacher A, de Dietrich G, Tunon-de-Lara JM, Marthan R, Laurent F. Bronchial measurement with three-dimensional quantitative thin-section CT in patients with cystic fibrosis. Radiology 2006;242:573–581. [DOI] [PubMed] [Google Scholar]
- 48.Nakano Y, Muro S, Sakai H, Hirai T, Chin K, Tsukino M, Nishimura K, Itoh H, Pare PD, Hogg JC, et al. Computed tomographic measurements of airway dimensions and emphysema in smokers. Correlation with lung function. Am J Respir Crit Care Med 2000;162:1102–1108. [DOI] [PubMed] [Google Scholar]
- 49.Nakano Y, Whittall KP, Kalloger SE, Coxson HO, Pare PD. Development and validation of human airway analysis algorithm using multidetector row CT. Proc SPIE 2002;4683:460–469. [Google Scholar]
- 50.Nakano Y, Wong JC, de Jong PA, Buzatu L, Nagao T, Coxson HO, Elliott WM, Hogg JC, Pare PD. The prediction of small airway dimensions using computed tomography. Am J Respir Crit Care Med 2005;171:142–146. [DOI] [PubMed] [Google Scholar]
- 51.Niimi A, Matsumoto H, Amitani R, Nakano Y, Mishima M, Minakuchi M, Nishimura K, Itoh H, Izumi T. Airway wall thickness in asthma assessed by computed tomography: relation to clinical indices. Am J Respir Crit Care Med 2000;162:1518–1523. [DOI] [PubMed] [Google Scholar]
- 52.Okazawa M, Muller NL, McNamara AE, Child S, Verburgt L, Pare PD. Human airway narrowing measured using high resolution computed tomography. Am J Respir Crit Care Med 1996;154:1557–1562. [DOI] [PubMed] [Google Scholar]
- 53.Patel BD, Coxson HO, Pillai SG, Agusti AGN, Calverley PMA, Donner CF, Make BJ, Müller NL, Rennard SI, Vestbo J, et al. Airway wall thickening and emphysema show independent familial aggregation in COPD. Am J Respir Crit Care Med 2008;178:500–505. [DOI] [PubMed]
- 54.Reinhardt JM, D'Souza ND, Hoffman EA. Accurate measurement of intrathoracic airways. IEEE Trans Med Imaging 1997;16:820–827. [DOI] [PubMed] [Google Scholar]
- 55.Saba OI, Hoffman EA, Reinhardt JM. Maximizing quantitative accuracy of lung airway lumen and wall measures obtained from X-ray CT imaging. J Appl Physiol 2003;95:1063–1075. [DOI] [PubMed] [Google Scholar]
- 56.Hasegawa M, Nasuhara Y, Onodera Y, Makita H, Nagai K, Fuke S, Ito Y, Betsuyaku T, Nishimura M. Airflow limitation and airway dimensions in chronic obstructive pulmonary disease. Am J Respir Crit Care Med 2006;173:1309–1315. [DOI] [PubMed] [Google Scholar]
- 57.Aykac D, Hoffman EA, McLennan G, Reinhardt JM. Segmentation and analysis of the human airway tree from three-dimensional X-ray CT images. IEEE Trans Med Imaging 2003;22:940–950. [DOI] [PubMed] [Google Scholar]
- 58.Mayo JR, Aldrich J, Muller NL. Radiation exposure at chest CT: a statement of the Fleischner Society. Radiology 2003;228:15–21. [DOI] [PubMed] [Google Scholar]
- 59.Madani A, De Maertelaer V, Zanen J, Gevenois PA. Pulmonary emphysema: radiation dose and section thickness at multidetector CT quantification–comparison with macroscopic and microscopic morphometry. Radiology 2007;243:250–257. [DOI] [PubMed] [Google Scholar]