Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1982 Oct;16(4):668–672. doi: 10.1128/jcm.16.4.668-672.1982

Rapid processing of urine specimens by urine screening and the AutoMicrobic system.

M Wadke, C McDonnell, J K Ashton
PMCID: PMC272443  PMID: 6759524

Abstract

A total of 1,500 clean-voided urine specimens were analyzed for the presence of bacteria by urine screening with the Autobac 1 system. The specimens found positive by this method were further processed on the same day for identification and for antimicrobial susceptibility testing on the AutoMicrobic system with the Enterobacteriaceae-plus Card and the General Susceptibility Card, respectively. The inocula for these tests were prepared from the centrifuged and washed growth in the eugonic broth aspirated from the Autobac cuvette chambers. Of 1,500 specimens that were analyzed, 183 contained single isolates of gram-negative bacilli. The results of these rapid procedures were compared with results for the same organisms isolated from urine specimens cultured by the conventional method. The data showed 92.3% agreement for identification and a correlation of 93.6% for antibiotic susceptibility between the two procedures. It is concluded that gram-negative bacilli can be rapidly identified and tested for antimicrobial susceptibility with a high degree of accuracy from the centrifuged eugonic broth after urine screening. These findings also suggest that the AutoMicrobic system provides a rapid and convenient method for same-day processing of positive urine cultures when combined with the urine screening procedure.

Full text

PDF
668

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Aldridge C., Jones P. W., Gibson S., Lanham J., Meyer M., Vannest R., Charles R. Automated microbiological detection/identification system. J Clin Microbiol. 1977 Oct;6(4):406–413. doi: 10.1128/jcm.6.4.406-413.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Alexander D. N., Ederer G. M., Matsen J. M. Evaluation of an adenosine 5'-triphosphate assay as a screening method to detect significant bacteriuria. J Clin Microbiol. 1976 Jan;3(1):42–46. doi: 10.1128/jcm.3.1.42-46.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Cady P., Dufour S. W., Lawless P., Nunke B., Kraeger S. J. Impedimetric screening for bacteriuria. J Clin Microbiol. 1978 Mar;7(3):273–278. doi: 10.1128/jcm.7.3.273-278.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Davis J. R., Stager C. E., Wende R. D., Qadri S. M. Clinical laboratory evaluation of the automicrobic system Enterobacteriaceae biochemical card. J Clin Microbiol. 1981 Oct;14(4):370–375. doi: 10.1128/jcm.14.4.370-375.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Hamoudi A. C., Lin S. Cost analysis of the Auto Microbic system urine identification card. J Clin Microbiol. 1981 Oct;14(4):411–414. doi: 10.1128/jcm.14.4.411-414.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Heinze P. A., Thrupp L. D., Anselmo C. R. A rapid (4--6-hour) urine-culture system for direct identification and direct antimicrobial susceptibility testing. Am J Clin Pathol. 1979 Feb;71(2):177–183. doi: 10.1093/ajcp/71.2.177. [DOI] [PubMed] [Google Scholar]
  7. Isenberg H. D., Gavan T. L., Smith P. B., Sonnenwirth A., Taylor W., Martin W. J., Rhoden D., Balows A. Collaborative investigation of the AutoMicrobic System Enterobacteriaceae biochemical card. J Clin Microbiol. 1980 Jun;11(6):694–702. doi: 10.1128/jcm.11.6.694-702.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Isenberg H. D., Gavan T. L., Sonnenwirth A., Taylor W. I., Washington J. A., 2nd Clinical laboratory evaluation of automated microbial detection/identification system in analysis of clinical urine specimens. J Clin Microbiol. 1979 Aug;10(2):226–230. doi: 10.1128/jcm.10.2.226-230.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Jenkins R. D., Hale D. C., Matsen J. M. Rapid semiautomated screening and processing of urine specimens. J Clin Microbiol. 1980 Mar;11(3):220–225. doi: 10.1128/jcm.11.3.220-225.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Jorgensen J. H., Jones P. M. Comparative evaluation of the Limulus assay and the direct Gram stain for detection of significant bacteriuria. Am J Clin Pathol. 1975 Jan;63(1):142–148. doi: 10.1093/ajcp/63.3.142. [DOI] [PubMed] [Google Scholar]
  11. KASS E. H. Asymptomatic infections of the urinary tract. Trans Assoc Am Physicians. 1956;69:56–64. [PubMed] [Google Scholar]
  12. Kelly M. T., Balfour L. C. Evaluation and optimization of urine screening by Autobac. J Clin Microbiol. 1981 Apr;13(4):677–680. doi: 10.1128/jcm.13.4.677-680.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Kelly M. T., Hale D. C., Matsen J. M. Rapid identification by the Micro-ID system of Enterobacteriaceae detected by urine screening. J Clin Microbiol. 1981 Sep;14(3):295–297. doi: 10.1128/jcm.14.3.295-297.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Lamb V. A., Dalton H. P., Wilkins J. R. Electrochemical method for the early detection of urinary-tract infections. Am J Clin Pathol. 1976 Jul;66(1):91–95. doi: 10.1093/ajcp/66.1.91. [DOI] [PubMed] [Google Scholar]
  15. Lewis J. F., Alexander J. Microscopy of stained urine smears to determine the need for quantitative culture. J Clin Microbiol. 1976 Oct;4(4):372–374. doi: 10.1128/jcm.4.4.372-374.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Nicholson D. P., Koepke J. A. The Automicrobic System for urines. J Clin Microbiol. 1979 Dec;10(6):823–833. doi: 10.1128/jcm.10.6.823-833.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Pezzlo M. T., Tan G. L., Peterson E. M., de la Maza L. M. Screening of urine cultures by three automated systems. J Clin Microbiol. 1982 Mar;15(3):468–474. doi: 10.1128/jcm.15.3.468-474.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Schifman R. B., Ryan K. J. Rapid automated identification of gram-negative bacilli from blood cultures with the AutoMicrobic system. J Clin Microbiol. 1982 Feb;15(2):260–264. doi: 10.1128/jcm.15.2.260-264.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Smith S. M., Cundy K. R., Gilardi G. L., Wong W. Evaluation of the AutoMicrobic system for identification of glucose-nonfermenting gram-negative rods. J Clin Microbiol. 1982 Feb;15(2):302–307. doi: 10.1128/jcm.15.2.302-307.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Tilton R. E., Tilton R. C. Automated direct antimicrobial susceptibility testing of microscopically screened urine cultures. J Clin Microbiol. 1980 Feb;11(2):157–161. doi: 10.1128/jcm.11.2.157-161.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES