Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1983 Feb;17(2):225–231. doi: 10.1128/jcm.17.2.225-231.1983

Reproducible enzyme-linked immunosorbent assay with a magnetic processing system for diagnosis of toxoplasmosis.

E Konishi, J Takahashi
PMCID: PMC272612  PMID: 6833477

Abstract

An enzyme-linked immunosorbent assay with polycarbonate-coated iron beads as the solid phase and with magnetic processing devices was evaluated for the quantitation of antibodies to Toxoplasma gondii in human serum samples. Under the parameters and other basic conditions determined in this study, the assay was highly reproducible: coefficients of variation for the absorbance values obtained with the positive serum were 2.42% in same-day tests and 3.75% in day-to-day tests. Significant correlations were observed between the present assay system and other conventional serological tests: correlation coefficients were 0.960 with the dye test and 0.929 with the latex agglutination test. Statistical analysis based on the frequency distribution of absorbance values for dye-test-positive and dye-test-negative serum samples gave feasible border lines for distinguishing between positive and doubtful samples (0.357) and between doubtful and negative samples (0.266). Under this diagnostic criterion, the results of our assay system agreed remarkably well with those obtained by the dye test and the latex agglutination test, with consistencies of 94.9 and 93.9%, respectively.

Full text

PDF
225

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Balsari A., Poli G., Molina V., Dovis M., Petruzzelli E., Boniolo A., Rolleri E. ELISA for toxoplasma antibody detection: a comparison with other serodiagnostic tests. J Clin Pathol. 1980 Jul;33(7):640–643. doi: 10.1136/jcp.33.7.640. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Burt S. M., Carter T. J., Kricka L. J. Thermal characteristics of microtitre plates used in immunological assays. J Immunol Methods. 1979;31(3-4):231–236. doi: 10.1016/0022-1759(79)90135-2. [DOI] [PubMed] [Google Scholar]
  3. Camargo M. E., Ferreira A. W., Mineo J. R., Takiguti C. K., Nakahara O. S. Immunoglobulin G and immunoglobulin M enzyme-linked immunosorbent assays and defined toxoplasmosis serological patterns. Infect Immun. 1978 Jul;21(1):55–58. doi: 10.1128/iai.21.1.55-58.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Carlier Y., Bout D., Dessaint J. P., Capron A., Van Knapen F., Ruitenberg E. J., Bergquist R., Huldt G. Evaluation of the enzyme-linked immunosorbent assay (ELISA) and other serological tests for the diagnosis of toxoplasmosis. Bull World Health Organ. 1980;58(1):99–105. [PMC free article] [PubMed] [Google Scholar]
  5. Denmark J. R., Chessum B. S. Standardization of enzyme-linked immunosorbent assay (ELISA) and the detection of Toxoplasma antibody. Med Lab Sci. 1978 Jul;35(3):227–232. [PubMed] [Google Scholar]
  6. Engvall E., Perlmann P. Enzyme-linked immunosorbent assay, Elisa. 3. Quantitation of specific antibodies by enzyme-labeled anti-immunoglobulin in antigen-coated tubes. J Immunol. 1972 Jul;109(1):129–135. [PubMed] [Google Scholar]
  7. Franco E. L., Walls K. W., Sulzer A. J. Reverse enzyme immunoassay for detection of specific anti-Toxoplasma immunoglobulin M antibodies. J Clin Microbiol. 1981 May;13(5):859–864. doi: 10.1128/jcm.13.5.859-864.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Heck F. C., Williams J. D., Pruett J. Interpretation of spectrophotometric absorbance values to define results of enzyme-linked immunosorbent assays. J Clin Microbiol. 1980 Apr;11(4):398–401. doi: 10.1128/jcm.11.4.398-401.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Konishi E., Yamaoka M. Enzyme-linked immunosorbent assay for detection of antibodies to Japanese encephalitis virus in swine sera. Kobe J Med Sci. 1982 Feb;28(1):7–17. [PubMed] [Google Scholar]
  10. Kricka L. J., Carter T. J., Burt S. M., Kennedy J. H., Holder R. L., Halliday M. I., Telford M. E., Wisdom G. B. Variability in the adsorption properties of microtitre plates used as solid supports in enzyme immunoassay. Clin Chem. 1980 May;26(6):741–744. [PubMed] [Google Scholar]
  11. LOWRY O. H., ROSEBROUGH N. J., FARR A. L., RANDALL R. J. Protein measurement with the Folin phenol reagent. J Biol Chem. 1951 Nov;193(1):265–275. [PubMed] [Google Scholar]
  12. Lin T. M., Halbert S. P., O'Connor G. R. Standardized quantitative enzyme-linked immunoassay for antibodies to Toxoplasma gondii. J Clin Microbiol. 1980 Jun;11(6):675–681. doi: 10.1128/jcm.11.6.675-681.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Lunde M. N., Jacobs L. Evaluation of a latex agglutination test for toxoplasmosis. J Parasitol. 1967 Oct;53(5):933–936. [PubMed] [Google Scholar]
  14. Naot Y., Remington J. S. An enzyme-linked immunosorbent assay for detection of IgM antibodies to Toxoplasma gondii: use for diagnosis of acute acquired toxoplasmosis. J Infect Dis. 1980 Nov;142(5):757–766. doi: 10.1093/infdis/142.5.757. [DOI] [PubMed] [Google Scholar]
  15. Sabin A. B., Feldman H. A. Dyes as Microchemical Indicators of a New Immunity Phenomenon Affecting a Protozoon Parasite (Toxoplasma). Science. 1948 Dec 10;108(2815):660–663. doi: 10.1126/science.108.2815.660. [DOI] [PubMed] [Google Scholar]
  16. Smith K. O., Gehle W. D. Magnetic transfer devices for use in solid-phase radioimmunoassays and enzyme-linked immunosorbent assays. J Infect Dis. 1977 Oct;136 (Suppl):S329–S336. doi: 10.1093/infdis/136.supplement_2.s329. [DOI] [PubMed] [Google Scholar]
  17. Smith K. O., Gehle W. D. Semiautomation of Immunoassays by use of magnetic transfer devices. Methods Enzymol. 1980;70(A):388–416. doi: 10.1016/s0076-6879(80)70066-6. [DOI] [PubMed] [Google Scholar]
  18. Voller A., Bidwell D. E., Bartlett A., Fleck D. G., Perkins M., Oladehin B. A microplate enzyme-immunoassay for toxoplasma antibody. J Clin Pathol. 1976 Feb;29(2):150–153. doi: 10.1136/jcp.29.2.150. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Walls K. W., Bullock S. L., English D. K. Use of the enzyme-linked immunosorbent assay (ELISA) and its microadaptation for the serodiagnosis of toxoplasmosis. J Clin Microbiol. 1977 Mar;5(3):273–277. doi: 10.1128/jcm.5.3.273-277.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. van Loon A. M., van der Veen J. Enzyme-linked immunosorbent assay for quantitation of toxoplasma antibodies in human sera. J Clin Pathol. 1980 Jul;33(7):635–639. doi: 10.1136/jcp.33.7.635. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES