Abstract
This three-center collaborative study was conducted to evaluate samples of the Microbial Profile System (MPS) antimicrobial microdilution panels [previously produced by Minnesota Mining & Manufacturing Co., (3M Co.), St. Paul, Minn. and currently produced by Flow Laboratories, Inc., Rockville, Md.). This was a three-phase study. In phase I, the inter- and intralaboratory agreement was determined by using strains with selected ranges of susceptibility. The MPS and reference microdilution minimum inhibitory concentrations were within acceptable variation, +/- 1 dilution for 97.7% for the MPS and 98.8% for the reference microdilution panels for the intralaboratory comparisons. The percentage of strains with minimum inhibitory concentrations in the acceptable range for the interlaboratory variation was 96.2% for the MPS and 96.0% for the reference microdilution panels. The phase II studies used strains with known resistance mechanisms. The percent agreement with these strains was: Enterobacteriaceae, 94.5%; nonenteric gram-negative rods, 95.4%; staphylococci, 92.3%; and streptococci, 96.6%. The overall agreement within acceptable limits was 94.7% with these strains. When testing 359 clinical isolates, the frequency of strains within the acceptable range of agreement between the two methods was 97.3%. The MPS panels gave results in each of the three study phases equivalent to those obtained with the reference microdilution panels.
Full text
PDF








Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Anhalt J. P., Brown S. D. High-performance liquid-chromatographic assay of aminoglycoside antibiotics in serum. Clin Chem. 1978 Nov;24(11):1940–1947. [PubMed] [Google Scholar]
- Barry A. L., Jones R. N., Gavan T. L. Evaluation of the micro-media system for quantitative antimicrobial drug susceptibility testing: a collaborative study. Antimicrob Agents Chemother. 1978 Jan;13(1):61–69. doi: 10.1128/aac.13.1.61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ericsson H. M., Sherris J. C. Antibiotic sensitivity testing. Report of an international collaborative study. Acta Pathol Microbiol Scand B Microbiol Immunol. 1971;217(Suppl):1+–1+. [PubMed] [Google Scholar]
- Gavan T. L., Jones R. N., Barry A. L. Evaluation of the Sensititre system for quantitative antimicrobial drug susceptibility testing: a collaborative study. Antimicrob Agents Chemother. 1980 Mar;17(3):464–469. doi: 10.1128/aac.17.3.464. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gavan T. L., Town M. A. A microdilution method for antibiotic susceptibility testing: an evaluation. Am J Clin Pathol. 1970 Jun;53(6):880–885. doi: 10.1093/ajcp/53.6.880. [DOI] [PubMed] [Google Scholar]
- Jones R. N., Gavan T. L., Barry A. L. Evaluation of the sensititre microdilution antibiotic susceptibility system against recent clinical isolates: three-laboratory collaborative study. J Clin Microbiol. 1980 Apr;11(4):426–429. doi: 10.1128/jcm.11.4.426-429.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jones R. N., Thornsberry C., Barry A. L., Gavan T. L. Evaluation of the Sceptor microdilution antibiotic susceptibility testing system: a collaborative investigation. J Clin Microbiol. 1981 Jan;13(1):184–194. doi: 10.1128/jcm.13.1.184-194.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- MacLowry J. D., Marsh H. H. Semiautomatic microtechnique for serial dilution-antibiotic sensitivity testing in the clinical laboratory. J Lab Clin Med. 1968 Oct;72(4):685–687. [PubMed] [Google Scholar]
- Tilton R. C., Isenberg H. D. Evaluation of the performance parameters of a prediluted, quantitative antibiotic susceptibility test device. Antimicrob Agents Chemother. 1977 Feb;11(2):271–276. doi: 10.1128/aac.11.2.271. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tilton R. C., Isenberg H. D. In-use evaluation of a prediluted quantitative antibiotic susceptibility test device. Antimicrob Agents Chemother. 1977 Oct;12(4):470–473. doi: 10.1128/aac.12.4.470. [DOI] [PMC free article] [PubMed] [Google Scholar]