Abstract
Cerebrospinal fluid specimens from patients with suspected meningitis were screened with the Phadebact Haemophilus Test (Pharmacia Diagnostics), with Bactogen (Wampole Laboratories), and by counterimmunoelectrophoresis. With culture-positive fluids, Phadebact coagglutination detected 95%, Bactogen latex agglutination detected 91%, and counterimmunoelectrophoresis detected only 79%. Both agglutination techniques were 25-fold more sensitive than counterimmunoelectrophoresis when tested with dilutions of positive fluids. To obtain specific reactions with the Phadebact reagents it was necessary to heat treat (95 degrees C, 5 min) the fluid; with Bactogen and counterimmunoelectrophoresis this was not necessary.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Dirks-Go S. I., Zanen H. C. Latex agglutination, counterimmunoelectrophoresis, and protein A co-agglutination in diagnosis of bacterial meningitis. J Clin Pathol. 1978 Dec;31(12):1167–1171. doi: 10.1136/jcp.31.12.1167. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Edwards E. A., Muehl P. M., Peckinpaugh R. O. Diagnosis of bacterial meningitis by counterimmunoelectrophoresis. J Lab Clin Med. 1972 Sep;80(3):449–454. [PubMed] [Google Scholar]
- Feigin R. D., Wong M., Shackelford P. G., Stechenberg B. W., Dunkle L. M., Kaplan S. Countercurrent immunoelectrophoresis of urine as well as of CSF and blood for diagnosis of bacterial meningitis. J Pediatr. 1976 Nov;89(5):773–775. doi: 10.1016/s0022-3476(76)80802-5. [DOI] [PubMed] [Google Scholar]
- Feldman W. E. Relation of concentrations of bacteria and bacterial antigen in cerebrospinal fluid to prognosis in patients with bacterial meningitis. N Engl J Med. 1977 Feb 24;296(8):433–435. doi: 10.1056/NEJM197702242960806. [DOI] [PubMed] [Google Scholar]
- Grasso R. J., West L. A., Holbrook N. J., Halkias D. G., Paradise L. J., Friedman H. Increased sensitivity of a new coagglutination test for rapid identification of Haemophilus influenzae type b. J Clin Microbiol. 1981 Jun;13(6):1122–1124. doi: 10.1128/jcm.13.6.1122-1124.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kumar A., Congeni B. L., Nankervis G. A. Latex agglutination test for rapid detection of bacterial antigens in body fluids. Ann Clin Lab Sci. 1980 Sep-Oct;10(5):377–382. [PubMed] [Google Scholar]
- Newman R. B., Stevens R. W., Gaafar H. A. Latex agglutination test for the diagnosis of Haemophilus influenzae meningitis. J Lab Clin Med. 1970 Jul;76(1):107–113. [PubMed] [Google Scholar]
- O'Reilly R. J., Anderson P., Ingram D. L., Peter G., Smith D. H. Circulating polyribophosphate in Hemophilus influenzae, type b meningitis. Correlation with clinical course and antibody response. J Clin Invest. 1975 Oct;56(4):1012–1022. doi: 10.1172/JCI108148. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Olcén P., Danielsson D., Kjellander J. The use of protein A-containing staphylococci sensitized with anti-meningococcal antibodies for grouping Neisseria meningitidis and demonstration of meningococcal antigen in cerebrospinal fluid. Acta Pathol Microbiol Scand B. 1975 Aug;83(4):387–396. doi: 10.1111/j.1699-0463.1975.tb00117.x. [DOI] [PubMed] [Google Scholar]
- Scheifele D. W., Daum R. S., Syriopoulou V. P., Siber G. R., Smith A. L. Comparison of two antigen detection techniques in a primate model of Haemophilus influenzae type b infection. Infect Immun. 1979 Dec;26(3):827–831. doi: 10.1128/iai.26.3.827-831.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Scheifele D. W., Ward J. I., Siber G. R. Advantage of latex agglutination over countercurrent immunoelectrophoresis in the detection of Haemophilus influenzae type b antigen in serum. Pediatrics. 1981 Dec;68(6):888–891. [PubMed] [Google Scholar]
- Shaw E. D., Darker R. J., Feldman W. E., Gray B. M., Pifer L. L., Scott G. B. Clinical studies of a new latex particle agglutination test for detection of Haemophilus influenzae type b polyribose phosphate antigen in serum, cerebrospinal fluid, and urine. J Clin Microbiol. 1982 Jun;15(6):1153–1156. doi: 10.1128/jcm.15.6.1153-1156.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thirumoorthi M. C., Dajani A. S. Comparison of staphylococcal coagglutination, latex agglutination, and counterimmunoelectrophoresis for bacterial antigen detection. J Clin Microbiol. 1979 Jan;9(1):28–32. doi: 10.1128/jcm.9.1.28-32.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ward J. I., Siber G. R., Scheifele D. W., Smith D. H. Rapid diagnosis of Hemophilus influenzae type b infections by latex particle agglutination and counterimmunoelectrophoresis. J Pediatr. 1978 Jul;93(1):37–42. doi: 10.1016/s0022-3476(78)80596-4. [DOI] [PubMed] [Google Scholar]
- Yolken R. H., Leister F. J. Investigation of enzyme immunoassay time courses: development of rapid assay systems. J Clin Microbiol. 1981 Apr;13(4):738–741. doi: 10.1128/jcm.13.4.738-741.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
