Abstract
An enzyme immunoassay for gentamicin utilizing glucose-6-phosphate dehydrogenase was compared to the radioimmunoassay. The enzyme immunoassay for gentamicin was accurate, specific, and easily performed. It offers an ulternative method to assay aminoglycosides and could be used in institutions using enzyme immunoassay to assay other drugs.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Appel G. B., Neu H. C. Gentamicin in 1978. Ann Intern Med. 1978 Oct;89(4):528–538. doi: 10.7326/0003-4819-89-4-528. [DOI] [PubMed] [Google Scholar]
- Barza M., Lauermann M. Why monitor serum levels of gentamicin? Clin Pharmacokinet. 1978 May-Jun;3(3):202–215. doi: 10.2165/00003088-197803030-00002. [DOI] [PubMed] [Google Scholar]
- Brunk S. D., Hadjiioannou T. P., Hadjiioannou S. I., Malmstadt H. V. Adaptation of "EMIT" technique for serum phenobarbital and diphenylhydantoin assays to the miniature centrifugal analyzer. Clin Chem. 1976 Jun;22(6):905–907. [PubMed] [Google Scholar]
- Finley P. R., Williams R. J., Byers J. M., 3rd Assay of phenytoin: adaptation of "EMIT" to the centrifugal analyzer. Clin Chem. 1976 Jun;22(6):911–914. [PubMed] [Google Scholar]
- Holmes R. K., Sanford J. P. Enzymatic assay for gentamicin and related aminoglycoside antibiotics. J Infect Dis. 1974 May;129(5):519–527. doi: 10.1093/infdis/129.5.519. [DOI] [PubMed] [Google Scholar]
- Lewis J. E., Nelson J. C., Elder H. A. Radioimmunoassay of an antibiotic: gentamicin. Nat New Biol. 1972 Oct 18;239(94):214–216. doi: 10.1038/newbio239214a0. [DOI] [PubMed] [Google Scholar]
- Reeves D. S., Bywater M. J. Quality control of serum gentamicin assays--experience of national surveys. J Antimicrob Chemother. 1975 Mar;1(1):103–116. doi: 10.1093/jac/1.1.103. [DOI] [PubMed] [Google Scholar]
- Rubenstein K. E., Schneider R. S., Ullman E. F. "Homogeneous" enzyme immunoassay. A new immunochemical technique. Biochem Biophys Res Commun. 1972 May 26;47(4):846–851. doi: 10.1016/0006-291x(72)90570-0. [DOI] [PubMed] [Google Scholar]
- Sabath L. D., Casey J. I., Ruch P. A., Stumpf L. L., Finland M. Rapid microassay of gentamicin, kanamycin, neomycin, streptomycin, and vancomycin in serum or plasma. J Lab Clin Med. 1971 Sep;78(3):457–463. [PubMed] [Google Scholar]
- Smith D. H., Van Otto B., Smith A. L. A rapid chemical assay for gentamicin. N Engl J Med. 1972 Mar 16;286(11):583–586. doi: 10.1056/NEJM197203162861106. [DOI] [PubMed] [Google Scholar]
