Abstract
Identification of Enterobacteriaceae by the AutoMicrobic System Enterobacteriaceae Biochemical Card was evaluated. Recent clinical isolates of enteric gram-negative bacilli (192) and glucose nonfermenters (3) were identified by the AutoMicrobic System, Micro-Media Systems, Micro-ID, API, and Enterotube II in comparison with conventional methods. The AutoMicrobic System and Micro-Media Systems correctly identified 97% of the organisms tested. Micro-ID, API, and Enterotube II correctly identified 94, 92, and 84% of the organisms, respectively. In addition to a high degree of identification accuracy, the AutoMicrobic System was convenient to operate and produced identification results in 8 h. Operation of the AutoMicrobic System also required minimal personnel time because it automatically monitored and interpreted the biochemical reactions and reported organism identifications. The AutoMicrobic System appears to be an efficient and accurate system for the identification of Enterobacteriaceae.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Barry A. L., Badal R. E., Effinger L. J. Identification of Enterobacteriaceae in frozen microdilution trays prepared by Micro-Media Systems. J Clin Microbiol. 1979 Oct;10(4):492–496. doi: 10.1128/jcm.10.4.492-496.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Barry A. L., Badal R. E. Rapid identification of Enterobacteriaceae with the micro-ID system versus API 20E and conventional media. J Clin Microbiol. 1979 Sep;10(3):293–298. doi: 10.1128/jcm.10.3.293-298.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Buesching W. J., Rhoden D. L., Esaias A. O., Smith P. B., Washington J. A., 2nd Evaluation of the modified Micro-ID system for identification of Enterobacteriaceae. J Clin Microbiol. 1979 Oct;10(4):454–458. doi: 10.1128/jcm.10.4.454-458.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Edberg S. C., Atkinson B., Chambers C., Moore M. H., Palumbo L., Zorzon C. F., Singer J. M. Clinical evaluation of the MICRO-ID, API 20E, and conventional media systems for identification of Enterobacteriacea. J Clin Microbiol. 1979 Aug;10(2):161–167. doi: 10.1128/jcm.10.2.161-167.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Isenberg H. D., Scherber J. S., Cosgrove J. O. Clinical laboratory evaluation of the further improved Enterotube and Encise II. J Clin Microbiol. 1976 Aug;2(2):139–141. [PMC free article] [PubMed] [Google Scholar]
- Kelly S. A., Washington J. A., 2nd Evaluation of Micro-Media Quad Panels for identification of the Enterobacteriaceae. J Clin Microbiol. 1979 Oct;10(4):515–518. doi: 10.1128/jcm.10.4.515-518.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nicholson D. P., Koepke J. A. The Automicrobic System for urines. J Clin Microbiol. 1979 Dec;10(6):823–833. doi: 10.1128/jcm.10.6.823-833.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Smith P. B., Gavan T. L., Isenberg H. D., Sonnenwirth A., Taylor W. I., Washington J. A., 2nd, Balows A. Multi-laboratory evaluation of an automated microbial detection/identification system. J Clin Microbiol. 1978 Dec;8(6):657–666. doi: 10.1128/jcm.8.6.657-666.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]