Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1981 Jan;13(1):120–125. doi: 10.1128/jcm.13.1.120-125.1981

Correlation studies of entero-set 20, API 20E and conventional media systems for Enterobacteriaceae identification.

K E Aldridge, R L Hodges
PMCID: PMC273734  PMID: 7007414

Abstract

The Entero-Set kit (Fisher Diagnostics) is a 20-biochemical-test system used in the identification of members of the Enterobacteriaceae. This kit was compared with the API 20E (Analytab Products) and conventional media systems, using 505 (303 stock and 202 clinical) strains of Enterobacteriaceae. When the Entero-Set and API 20E results were compared with those of the conventional media system, the Entero-Set performed as well as the API 20E in overall identification. Comparison of common biochemical tests among the various systems showed that citrate, arabinose, adonitol, inositol, and malonate gave correlations below 90%. The majority of the discrepancies were found among stock cultures. In addition, most discrepancies occurred with species of Enterobacter, Salmonella, Proteus, Klebsiella, and Serratia. Reproducibility studies showed the Entero-Set system to perform with a high degree of accuracy and reproducibility.

Full text

PDF
120

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Aldridge K. E., Gardner B. B., Clark S. J., Matsen J. M. Comparison of micro-ID, API 20E, and conventional media systems in identification of Enterobacteriaceae. J Clin Microbiol. 1978 Jun;7(6):507–513. doi: 10.1128/jcm.7.6.507-513.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Edberg S. C., Atkinson B., Chambers C., Moore M. H., Palumbo L., Zorzon C. F., Singer J. M. Clinical evaluation of the MICRO-ID, API 20E, and conventional media systems for identification of Enterobacteriacea. J Clin Microbiol. 1979 Aug;10(2):161–167. doi: 10.1128/jcm.10.2.161-167.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Gardner J. M., Snyder B. A., Gröschel D. Experiences with the Analytab system for the identification of Enterobacteriaceae. Pathol Microbiol (Basel) 1972;38(2):103–106. doi: 10.1159/000162395. [DOI] [PubMed] [Google Scholar]
  4. Hansen S. L., Hardesty D. R., Myers B. M. Evaluation of the BBL Minitek system for the identification of Enterobacteriaceae. Appl Microbiol. 1974 Nov;28(5):798–801. doi: 10.1128/am.28.5.798-801.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Kiehn T. E., Brennan K., Ellner P. D. Evaluation of the Minitek system for identification of Enterobacteriaceae. Appl Microbiol. 1974 Oct;28(4):668–671. doi: 10.1128/am.28.4.668-671.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Lachica R. V., Genigeorgis C., Hoeprich P. D. Metachromatic agar-diffusion methods for detecting staphylococcal nuclease activity. Appl Microbiol. 1971 Apr;21(4):585–587. doi: 10.1128/am.21.4.585-587.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Nord C. E., Lindberg A. A., Dahlbäck A. Evaluation of five test-kits-API, AuxoTab, Enterotube, PathoTec and R-B-for identification of Enterobacteriaceae. Med Microbiol Immunol. 1974 Mar 22;159(3):211–220. doi: 10.1007/BF02121337. [DOI] [PubMed] [Google Scholar]
  8. Rhoden D. L., Tomfohrde K. M., Smith P. B., Balows A. Evaluation of the improved Auxotab 1 System for identifying Enterobacteriaceae. Appl Microbiol. 1973 Aug;26(2):215–216. doi: 10.1128/am.26.2.215-216.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Smith P. B., Tomfohrde K. M., Rhoden D. L., Balows A. Evaluation of the modified R-B system for identification of Enterobacteriaceae. Appl Microbiol. 1971 Nov;22(5):928–929. doi: 10.1128/am.22.5.928-929.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Tomfohrde K. M., Rhoden D. L., Smith P. B., Balows A. Evaluation of the redesigned enterotube--a system for the identification of Enterobacteriaceae. Appl Microbiol. 1973 Feb;25(2):301–304. doi: 10.1128/am.25.2.301-304.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Washington J. A., 2nd, Yu P. K., Martin W. J. Evaluation of the Auxotab Enteric 1 System for identification of Enterobacteriaceae. Appl Microbiol. 1972 Feb;23(2):298–300. doi: 10.1128/am.23.2.298-300.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES