Abstract
A simple technique has been developed with which five serum specimens can be chromatographed at one time and concentrated immunoglobulin M fractions can be obtained without using fraction collectors and ultraviolet monitors. When applied to the detection of rubella immunoglobulin M antibody, this technique gave results comparable to the sucrose gradient centrifugation method.
Full text
PDF



Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Blom H., Haukenes G. Identification of non-specific serum inhibitors of rubella virus haemagglutination. Med Microbiol Immunol. 1974 Jun 19;159(4):271–277. doi: 10.1007/BF02123736. [DOI] [PubMed] [Google Scholar]
- Bürgin-Wolff A., Hernandez R., Just M. Separation of rubella IgM, IgA, and IgG antibodies by gel filtration on agarose. Lancet. 1971 Dec 11;2(7737):1278–1280. doi: 10.1016/s0140-6736(71)90600-3. [DOI] [PubMed] [Google Scholar]
- Cooper L. Z., Matters B., Rosenblum J. K., Krugman S. Experience with a modified rubella hemagglutination inhibition antibody test. JAMA. 1969 Jan 6;207(1):89–93. [PubMed] [Google Scholar]
- Dold H. J., Northrop R. L. The nonspecific inhibitors of rubella-virus hemagglutination. Proc Soc Exp Biol Med. 1968 Jun;128(2):577–581. doi: 10.3181/00379727-128-33071. [DOI] [PubMed] [Google Scholar]
- Gupta J. D., Peterson V., Stout M., Murphy A. M. Single-sample diagnosis of recent rubella by fractionation of antibody on Sephadex G-200 column. J Clin Pathol. 1971 Sep;24(6):547–550. doi: 10.1136/jcp.24.6.547. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Haukenes G., Blom H. False positive rubella virus haemagglutination inhibition reactions: occurrence and disclosure. Med Microbiol Immunol. 1975;161(2):99–106. doi: 10.1007/BF02121750. [DOI] [PubMed] [Google Scholar]
- Inouye S., Kono R., Takeuchi Y. Oligomeric immunoglobulin A antibody response to rubella virus infection. J Clin Microbiol. 1978 Jul;8(1):1–6. doi: 10.1128/jcm.8.1.1-6.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Iwasa S., Hori M. Improved rubella hemagglutination inhibtion test: inactivation of non-immunoglobulin hemagglutination inhibitors by phospholipase C. J Clin Microbiol. 1976 Dec;4(6):461–466. doi: 10.1128/jcm.4.6.461-466.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pattison J. R., Mace J. E. A simple, inexpensive gel filtration technique for use in diagnostic serology. J Clin Pathol. 1973 Apr;26(4):309–311. doi: 10.1136/jcp.26.4.309. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pattison J. R., Mace J. E. Elution patterns of rubella IgM, IgA, and IgG antibodies from a dextran and an agarose gel. J Clin Pathol. 1975 Aug;28(8):670–673. doi: 10.1136/jcp.28.8.670. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pattison J. R., Mace J. E. The detection of specific IgM antibodies following infection with rubella virus. J Clin Pathol. 1975 May;28(5):377–382. doi: 10.1136/jcp.28.5.377. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vesikari T., Vaheri A. Rubella: a method for rapid diagnosis of a recent infection by demonstration of the IgM antibodies. Br Med J. 1968 Jan 27;1(5586):221–223. doi: 10.1136/bmj.1.5586.221. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zeineh R. A., Fiorella B. J., Nijm E. P., Dunea G. Single hollow fiber microconcentrator. Anal Chem. 1974 Mar;46(3):477–480. doi: 10.1021/ac60339a034. [DOI] [PubMed] [Google Scholar]
- al-Nakib W., Best J. M., Banatvala J. E. Letter: Rubella-specific IgM and a new inhibitor. Br Med J. 1974 Aug 31;3(5930):579–579. doi: 10.1136/bmj.3.5930.579-c. [DOI] [PMC free article] [PubMed] [Google Scholar]