Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1981 Mar;13(3):456–458. doi: 10.1128/jcm.13.3.456-458.1981

Identification of Pseudomonas aeruginosa by pyocyanin production on Tech agar.

E A Reyes, M J Bale, W H Cannon, J M Matsen
PMCID: PMC273813  PMID: 6787067

Abstract

Pseudomonas aeruginosa is the only gram-negative bacillus capable of producing the very distinctive water-soluble pigment pyocyanin. We evaluated the reliability of this characteristic as a unique test for the identification of this organism by using Tech agar (BBL Microbiology Systems, Cockeysville, Md.) medium. A retrospective and prospective analysis was performed with a total of 835 strains of P. aeruginosa; 818 (98%) produced pigment within 48 h of incubation, and 96% of those which produced pigment were positive after overnight incubation. Seventeen strains (2.0%) failed to produce pigment; 15 were mucoid strains from patients with cystic fibrosis. Tech agar is an effective, simple, and inexpensive medium for P. aeruginosa identification and may be used as a unique test for all potential P. aeruginosa isolates (beta hemolytic on blood agar; lactose-negative, oxidase-positive colonies). Nonpigmented mucoid strains, as well as other nonpigmented organisms, will require additional testing to ensure proper identification.

Full text

PDF
456

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Blazevic D. J., Koepcke M. H., Matsen J. M. Incidence and identification of Pseudomonas fluorescens and Pseudomonas putida in the clinical laboratory. Appl Microbiol. 1973 Jan;25(1):107–110. doi: 10.1128/am.25.1.107-110.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Buck G. E., Sielaff B. H., Boshard R., Matsen J. M. Automated, rapid identification of bacteria by pattern analysis of growth inhibition profiles obtained with Autobac 1. J Clin Microbiol. 1977 Jul;6(1):46–49. doi: 10.1128/jcm.6.1.46-49.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Burdash N. M., Bannister E. R., Manos J. P., West M. E. A comparison of four commercial systems for the identification of nonfermentative gram-negative bacilli. Am J Clin Pathol. 1980 Apr;73(4):564–569. doi: 10.1093/ajcp/73.4.564. [DOI] [PubMed] [Google Scholar]
  4. KING E. O., WARD M. K., RANEY D. E. Two simple media for the demonstration of pyocyanin and fluorescin. J Lab Clin Med. 1954 Aug;44(2):301–307. [PubMed] [Google Scholar]
  5. Morris M. J., Young V. M., Moody M. R. Evaluation of a multitest system for identification of saccharolytic pseudomonads. Am J Clin Pathol. 1978 Jan;69(1):41–47. doi: 10.1093/ajcp/69.1.41. [DOI] [PubMed] [Google Scholar]
  6. Otto L. A., Pickett M. J. Rapid method for identification of gram-negative, nonfermentative bacilli. J Clin Microbiol. 1976 Jun;3(6):566–575. doi: 10.1128/jcm.3.6.566-575.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Pickett M. J., Pedersen M. M. Characterization of saccharolytic nonfermentative bacteria associated with man. Can J Microbiol. 1970 May;16(5):351–362. doi: 10.1139/m70-062. [DOI] [PubMed] [Google Scholar]
  8. Pickett M. J., Pedersen M. M. Nonfermentative bacilli associated with man. II. Detection and identification. Am J Clin Pathol. 1970 Aug;54(2):164–177. doi: 10.1093/ajcp/54.2.164. [DOI] [PubMed] [Google Scholar]
  9. Rosenthal S. L., Freundlich L. F., Washington W. Laboratory evaluation of a multitest system for identification of gram-negative organisms. Am J Clin Pathol. 1978 Dec;70(6):914–917. doi: 10.1093/ajcp/70.6.914. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES