Abstract
A reverse enzyme immunoassay (R-EIA) is described, in which polystyrene muplates are sensitized with anti-immunoglobulin M (IgM) (mu chain) antibodies and then sequentially allowed to react with patient's serum, peroxidase-labeled Toxoplasma gondii soluble antigen, and substrate. Measurement of activity of the solid-phase bound enzyme conjugate was done by colorimetric reading of the final developed color and kinetically by the initial rate of color development. This R-EIA allowed full resolution between absorbance values of a group of 36 sera which presented positive results in the Toxoplasma IgM immunofluorescence test and the remaining groups, which consisted of 39 normal individuals, 22 rheumatoid factor-positive sera, 8 Waldenstrom's macroglobulinemic sera, 3 infectious mononucleosis samples, and 6 high-titered IgG anti-T. gondii sera. No interference of rheumatoid factor IgM or inhibition by high-titered specific IgG was detected, even in the false IgM immunofluorescence-positive rheumatoid factor samples. Likewise, false-negative IgM immunofluorescence samples gave positive R-EIA even without adsorption with Staphylococcus aureus protein A. The possibility of direct tagging of the antigen with the enzyme eliminates the need for using antigen and anti-antigen conjugates as separate layers, therefore eliminating one step in the assay.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Camargo M. E., Ferreira A. W., Mineo J. R., Takiguti C. K., Nakahara O. S. Immunoglobulin G and immunoglobulin M enzyme-linked immunosorbent assays and defined toxoplasmosis serological patterns. Infect Immun. 1978 Jul;21(1):55–58. doi: 10.1128/iai.21.1.55-58.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Camargo M. E., Leser P. G., Leser W. S. Diagnostic information from serological tests in human toxoplasmosis. I. A comparative study of hemagglutination, complement fixation, IgG and IgM-immunofluorescence tests in 3,752 serum samples. Rev Inst Med Trop Sao Paulo. 1976 Jul-Aug;18(4):215–226. [PubMed] [Google Scholar]
- Camargo M. E., Leser P. G., Rocca A. Rheumatoid factors as a cause for false positive IgM anti-toxoplasma fluorescent tests. A technique for specific results. Rev Inst Med Trop Sao Paulo. 1972 Sep-Oct;14(5):310–313. [PubMed] [Google Scholar]
- Chantler S., Devries E., Allen P. R., Hurn B. A. A rapid immunofluorescent procedure for the detection of specific IgG and IgM antibody in sera using Staphylococcus aureus and latex-IgG as absorbents. J Immunol Methods. 1976;13(3-4):367–380. doi: 10.1016/0022-1759(76)90083-1. [DOI] [PubMed] [Google Scholar]
- Cohen I. R., Norins L. C., Julian A. J. Competition between, and effectiveness of, IgG and IgM antibodies in indirect fluorescent antibody and other tests. J Immunol. 1967 Jan;98(1):143–149. [PubMed] [Google Scholar]
- Denmark J. R., Chessum B. S. Standardization of enzyme-linked immunosorbent assay (ELISA) and the detection of Toxoplasma antibody. Med Lab Sci. 1978 Jul;35(3):227–232. [PubMed] [Google Scholar]
- Dinesen B., Nielsen S. A sensitive enzyme immunoassay for the quantitation of human IgM. Scand J Clin Lab Invest. 1979 Sep;39(5):449–454. doi: 10.3109/00365517909106130. [DOI] [PubMed] [Google Scholar]
- Duermeyer W., Wielaard F., van Gruijthuijsen H., Swinkels J. Enzyme-linked immunosorbent assay for detection of immunoglobulin M antibodies against Toxoplasma gondii. J Clin Microbiol. 1980 Dec;12(6):805–806. doi: 10.1128/jcm.12.6.805-806.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Duermeyer W., van der Veen J. Specific detection of IgM-antibodies by ELISA, applied in hepatitis-A. Lancet. 1978 Sep 23;2(8091):684–685. doi: 10.1016/s0140-6736(78)92802-7. [DOI] [PubMed] [Google Scholar]
- Gerlich W. H., Lüer W. Selective detection of IgM-antibody against core antigen of the hepatitis B virus by a modified enzyme immune assay. J Med Virol. 1979;4(3):227–238. doi: 10.1002/jmv.1890040308. [DOI] [PubMed] [Google Scholar]
- Handsher R., Fogel A. Modified staphylococcal absorption method used for detecting rubella-specific immunoglobin M antibodies during a rubella epidemic. J Clin Microbiol. 1977 Jun;5(6):588–592. doi: 10.1128/jcm.5.6.588-592.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hyde B., Barnett E. V., Remington J. S. Method for differentiation of nonspecific from specfic toxoplasma IgM fluorescent antibodies in patients with rheumatoid factor. Proc Soc Exp Biol Med. 1975 Apr;148(4):1184–1188. doi: 10.3181/00379727-148-38713. [DOI] [PubMed] [Google Scholar]
- Karim K. A., Ludlam G. B. The relationship and significance of antibody titres as determined by various serological methods in glandular and ocular toxoplasmosis. J Clin Pathol. 1975 Jan;28(1):42–49. doi: 10.1136/jcp.28.1.42. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Leser P. G., Camargo M. E., Baruzzi R. Toxoplasmosis serologic tests in Brazilian indians (Kren-akorore) of recent contact with civilized man. Rev Inst Med Trop Sao Paulo. 1977 Jul-Aug;19(4):232–236. [PubMed] [Google Scholar]
- Lin T. M., Halbert S. P., O'Connor G. R. Standardized quantitative enzyme-linked immunoassay for antibodies to Toxoplasma gondii. J Clin Microbiol. 1980 Jun;11(6):675–681. doi: 10.1128/jcm.11.6.675-681.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- MASON J. K. An ox cell haemolysin test for the diagnosis of infectious mononucleosis. J Hyg (Lond) 1951 Dec;49(4):471–481. doi: 10.1017/s002217240006678x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mineo J. R., Camargo M. E., Ferreira A. W. Enzyme-linked immunosorbent assay for antibodies to Toxoplasma gondii polysaccharides in human toxoplasmosis. Infect Immun. 1980 Feb;27(2):283–287. doi: 10.1128/iai.27.2.283-287.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nakane P. K., Kawaoi A. Peroxidase-labeled antibody. A new method of conjugation. J Histochem Cytochem. 1974 Dec;22(12):1084–1091. doi: 10.1177/22.12.1084. [DOI] [PubMed] [Google Scholar]
- Naot Y., Remington J. S. An enzyme-linked immunosorbent assay for detection of IgM antibodies to Toxoplasma gondii: use for diagnosis of acute acquired toxoplasmosis. J Infect Dis. 1980 Nov;142(5):757–766. doi: 10.1093/infdis/142.5.757. [DOI] [PubMed] [Google Scholar]
- O'Beirne A. J., Cooper H. R. Heterogeneous enzyme immunoassay. J Histochem Cytochem. 1979 Aug;27(8):1148–1162. doi: 10.1177/27.8.383822. [DOI] [PubMed] [Google Scholar]
- Pyndiah N., Krech U., Price P., Wilhelm J. Simplified chromatographic separation of immunoglobulin M from G and its application to toxoplasma indirect immunofluorescence. J Clin Microbiol. 1979 Feb;9(2):170–174. doi: 10.1128/jcm.9.2.170-174.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Remington J. S. False-positive IgM anti-toxoplasma fluorescent test due to rheumatoid factor. Lancet. 1978 Apr 15;1(8068):832–832. doi: 10.1016/s0140-6736(78)93046-5. [DOI] [PubMed] [Google Scholar]
- Roggendorf M., Frösner G. G., Deinhardt F., Scheid R. Comparison of solid phase test systems for demonstrating antibodies against hepatitis A virus (anti-Hav) of the IgM-class. J Med Virol. 1980;5(1):47–62. doi: 10.1002/jmv.1890050107. [DOI] [PubMed] [Google Scholar]
- Tsang V. C., Wilson B. C., Maddison S. E. Kinetic studies of a quantitative single-tube enzyme-linked immunosorbent assay. Clin Chem. 1980 Aug;26(9):1255–1260. [PubMed] [Google Scholar]
- Voller A., Bidwell D. E., Bartlett A., Fleck D. G., Perkins M., Oladehin B. A microplate enzyme-immunoassay for toxoplasma antibody. J Clin Pathol. 1976 Feb;29(2):150–153. doi: 10.1136/jcp.29.2.150. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Walls K. W., Barnhart E. R. Titration of human serum antibodies to Toxoplasma gondii with a simple fluorometric assay. J Clin Microbiol. 1978 Feb;7(2):234–235. doi: 10.1128/jcm.7.2.234-235.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Walls K. W., Bullock S. L., English D. K. Use of the enzyme-linked immunosorbent assay (ELISA) and its microadaptation for the serodiagnosis of toxoplasmosis. J Clin Microbiol. 1977 Mar;5(3):273–277. doi: 10.1128/jcm.5.3.273-277.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
