Abstract
A single radial immune hemolysis test for the detection of thermolabile enterotoxin has been developed for routine purposes. Stationary cultures from enterotoxigenic Escherichia coli in Casamino Acids-yeast extract medium may be used for the detection of this enterotoxin, and under the conditions of the experiment, the single radial immune hemolysis test was as sensitive as the passive immune hemolysis test. The results obtained in the single radial immune hemolysis test agreed entirely with those obtained in the passive immune hemolysis test, and no false-positive reactions were obtained when cholera antitoxin diluted 1:80 was used. The assay is easy to perform, inexpensive, and specially designed for less-equipped laboratories.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bramucci M. G., Holmes R. K. Radial passive immune hemolysis assay for detection of heat-labile enterotoxin produced by individual colonies of Escherichia coli or Vibrio cholerae. J Clin Microbiol. 1978 Aug;8(2):252–255. doi: 10.1128/jcm.8.2.252-255.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bäck E., Svennerholm A. M., Holmgren J., Möllby R. Evaluation of a ganglioside immunosorbent assay for detection of Escherichia coli heat-labile enterotoxin. J Clin Microbiol. 1979 Dec;10(6):791–795. doi: 10.1128/jcm.10.6.791-795.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Donta S. T., Moon H. W., Whipp S. C. Detection of heat-labile Escherichia coli enterotoxin with the use of adrenal cells in tissue culture. Science. 1974 Jan 25;183(4122):334–336. doi: 10.1126/science.183.4122.334. [DOI] [PubMed] [Google Scholar]
- Evans D. J., Evans D. G., Gorbach S. L. Polymyxin B-Induced Release of Low-Molecular-Weight, Heat-Labile Enterotoxin from Escherichia coli. Infect Immun. 1974 Nov;10(5):1010–1017. doi: 10.1128/iai.10.5.1010-1017.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Evans D. J., Jr, Evans D. G. Direct serological assay for the heat-labile enterotoxin of Escherichia coli, using passive immune hemolysis. Infect Immun. 1977 May;16(2):604–609. doi: 10.1128/iai.16.2.604-609.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Evans D. J., Jr, Evans D. G., Gorbach S. L. Production of vascular permeability factor by enterotoxigenic Escherichia coli isolated from man. Infect Immun. 1973 Nov;8(5):725–730. doi: 10.1128/iai.8.5.725-730.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Forger J. M., 3rd, Gilfillan R. F. Single-radial hemolysis as a cost-effective determinant of Rubella antibody status. J Clin Microbiol. 1979 Jan;9(1):115–119. doi: 10.1128/jcm.9.1.115-119.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Greenberg H. B., Sack D. A., Rodriguez W., Sack R. B., Wyatt R. G., Kalica A. R., Horswood R. L., Chanock R. M., Kapikian A. Z. Microtiter solid-phase radioimmunoassay for detection of Escherichia coli heat-labile enterotoxin. Infect Immun. 1977 Sep;17(3):541–545. doi: 10.1128/iai.17.3.541-545.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Guerrant R. L., Brunton L. L., Schnaitman T. C., Rebhun L. I., Gilman A. G. Cyclic adenosine monophosphate and alteration of Chinese hamster ovary cell morphology: a rapid, sensitive in vitro assay for the enterotoxins of Vibrio cholerae and Escherichia coli. Infect Immun. 1974 Aug;10(2):320–327. doi: 10.1128/iai.10.2.320-327.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Serafim M. B., Pestana de Castro A. F., Lemos dos Reis M. H., Trabulsi L. R. Passive immune hemolysis for detection of heat-labile enterotoxin produced by Escherichia coli isolated from different sources. Infect Immun. 1979 Jun;24(3):606–610. doi: 10.1128/iai.24.3.606-610.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Smith N. W., Sack R. B. Immunologic cross-reactions of enterotoxins from Escherichia coli and Vibrio cholerae. J Infect Dis. 1973 Feb;127(2):164–170. doi: 10.1093/infdis/127.2.164. [DOI] [PubMed] [Google Scholar]
- Speirs J. I., Stavric S., Konowalchuk J. Assay of Escherichia coli heat-labile enterotoxin with vero cells. Infect Immun. 1977 May;16(2):617–622. doi: 10.1128/iai.16.2.617-622.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yolken R. H., Greenberg H. B., Merson M. H., Sack R. B., Kapikian A. Z. Enzyme-linked immunosorbent assay for detection of Escherichia coli heat-labile enterotoxin. J Clin Microbiol. 1977 Nov;6(5):439–444. doi: 10.1128/jcm.6.5.439-444.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- de Castro A. F., Serafim M. B., Gomes J. A., Gatti M. S. Improvements in the passive immune hemolysis test for assaying enterotoxigenic Escherichia coli. J Clin Microbiol. 1980 Nov;12(5):714–717. doi: 10.1128/jcm.12.5.714-717.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]