Abstract
Two commercially available micromethod multitest systems (API, Analytab Products, Inc., Minitek-Bioquest) were compared with conventional tests suggested by the Center for Disease Control for the identification of anaerobes. Anaerobiosis for the microsystems was achieved using GasPak system (BBL), A total of 175 anaerobes, including 158 clinical isolates and 17 reference strains, were used. Gram morphology, gas-liquid chromatography data, and biochemical reactions from the Center for Disease Control and Virginia Polytechnic Institute anaerobic manuals were used to identify the organisms. The Minitek system included a new anaerobe inoculum broth and two new disks, dextrose without nitrate and nitrate reductase disks. The percentage of correlation of 12 biochemicals using Minitek and 11 biochemicals using the API were compared with the Center for Disease Control reactions. The percentage of correlation of both positive and negative reactions with the API anaerobic strip ranged from 70.8 to 99.4% and with the Minitek from 97.1 to 100%. The microsystems were also evaluated as to the ease of use, adaptabilty to a clinical laboratory, time, and cost.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Finegold S. M., Bartlett J. G., Chow A. W., Flora D. J., Gorbach S. L., Harder E. J., Tally F. P. Management of anaerobic infections. Ann Intern Med. 1975 Sep;83(3):375–389. doi: 10.7326/0003-4819-83-3-375. [DOI] [PubMed] [Google Scholar]
- Gorbach S. L., Bartlett J. G. Anaerobic infections. 1. N Engl J Med. 1974 May 23;290(21):1177–1184. doi: 10.1056/NEJM197405232902106. [DOI] [PubMed] [Google Scholar]
- Moore H. B., Sutter V. L., Finegold S. M. Comparison of three procedures for biochemical testing of anaerobic bacteria. J Clin Microbiol. 1975 Jan;1(1):15–24. doi: 10.1128/jcm.1.1.15-24.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stargel D., Thompson F. S., Phillips S. E., Lombard G. L., Dowell V. R., Jr Modification of the Minitek Miniaturized Differentiation System for characterization of anaerobic bacteria. J Clin Microbiol. 1976 Mar;3(3):291–301. doi: 10.1128/jcm.3.3.291-301.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Starr S. E., Thompson F. S., Dowell V. R., Jr, Balows A. Micromethod system for identification of anaerobic bacteria. Appl Microbiol. 1973 May;25(5):713–717. doi: 10.1128/am.25.5.713-717.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sutter V. L., Finegold S. M. Antibiotic disc susceptibility tests for rapid presumptive identification of Gram-negative anaerobic bacilli. Appl Microbiol. 1971 Jan;21(1):13–20. doi: 10.1128/am.21.1.13-20.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]