Abstract
A radiometric procedure for rapid detection of bacteria in clinical blood specimens was utilized over a period of 1 year in this laboratory. Although in initial studies it was felt that all positive bacteremias would be detected by radiometric examination of cultures for 14CO2 evolution over a 7-day period, we found in the present study that a significant number of bacteria were not detected, except by blind subculturing on day 7 before discarding the culture sample. Microorganisms were detected in 490 individual specimens from 348 patients after examination of 6,200 individual blood specimens, both anaerobically and aerobically. All but 30 of the positive specimens were detected by the radiometric procedure, with an average detection time of 30.5 h. Thirty organisms, representing 6% of the total organisms isolated, were not detected by the BACTEC apparatus. The predominating organisms missed by the radiometric method were group D streptococci, both enterococcal and non-enterococcal species. These isolates represented two-thirds of the total number of organisms not detected by the radiometric procedure. A majority of bacteria detected only upon terminal subculture were isolates from a very small number of patients, suggesting that these organisms might have specific properties that preclude their detection by radiometric assay. Nevertheless, our study results indicate that it is essential that all radiometrically examined blood culture specimens be subcultured prior to discard in order to lessen the likelihood of missing a microbial pathogen.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bannatyne R. M., Harnett N. Radiometric detection of bacteremia in neonates. Appl Microbiol. 1974 Jun;27(6):1067–1069. doi: 10.1128/am.27.6.1067-1069.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brooks K., Sodeman T. Rapid detection of bacteremia by a radiometric system. A clinical evaluation. Am J Clin Pathol. 1974 Jun;61(6):859–866. doi: 10.1093/ajcp/61.6.859. [DOI] [PubMed] [Google Scholar]
- Caslow M., Ellner P. D., Kiehn T. E. Comparison of the BACTEC system with blind subculture for the detection of bacteremia. Appl Microbiol. 1974 Sep;28(3):435–438. doi: 10.1128/am.28.3.435-438.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Coleman R. M., Laslie W. W., Lambe D. W., Jr Clinical comparison of aerobic, hypertonic, and anaerobic culture media for the radiometric detection of bacteremia. J Clin Microbiol. 1976 Mar;3(3):281–286. doi: 10.1128/jcm.3.3.281-286.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- DeBlanc H. J., Jr, DeLand F., Wagner H. N., Jr Automated radiometric detection of bacteria in 2,967 blood cultures. Appl Microbiol. 1971 Nov;22(5):846–849. doi: 10.1128/am.22.5.846-849.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Renner E. D., Gatheridge L. A., Washington J. A., 2nd Evaluation of radiometric system for detecting bacteremia. Appl Microbiol. 1973 Sep;26(3):368–372. doi: 10.1128/am.26.3.368-372.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rosner R. Comparison of macroscopic, microscopic, and radiometric examinations of clinical blood cultures in hypertonic media. Appl Microbiol. 1974 Oct;28(4):644–646. doi: 10.1128/am.28.4.644-646.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thiemke W. A., Wicher K. Laboratory experience with a radiometric method for detecting bacteremia. J Clin Microbiol. 1975 Mar;1(3):302–308. doi: 10.1128/jcm.1.3.302-308.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]