Abstract
The Analytab Products, Inc. (API), anaerobic multitest microsystem (MICRO) was compared with the Center for Disease Control conventional (CONV) thioglycolate (supplemented with hemin and vitamin K1) system and with pre-reduced anaerobically sterilized (PRAS) media as recommended by the Virginia Polytechnic Institute. Growth from a solid medium was suspended to produce standard inocula. Substrates included 16 carbohydrates, indole, urea, gelatin, and esculin. API strips were inoculated in air and incubated in GasPak (BBL) jars. MICRO tests were read at 1 and 2 days. CONV tests at 1, 2, and 7 days, and PRAS tests at 3 weeks. One hundred thirty well-characterized strains of anaerobes (76 gram-negative rods, 16 cocci, 26 gram-positive nonsporeforming rods, and 12 clostridia), including 48 reference strains, were studied. Of 2,600 tests performed, 2,085 (80.2%) showed agreement with all three methods. There was 90.9% agreement between the MICRO and CONV, 84.9% between the MICRO and PRAS, and 84.6% between the CONV and PRAS tests. All MICRO tests were reliable except for indole, which was not sensitive enough, and gelatin, which was very insensitive. The MICRO system permits performance of biochemical tests at the workbench in the average clinical laboratory without the need for expensive equipment and time-consuming procedures.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Dowell V. R., Jr Comparison of techniques for isolation and identification of anaerobic bacteria. Am J Clin Nutr. 1972 Dec;25(12):1335–1343. doi: 10.1093/ajcn/25.12.1335. [DOI] [PubMed] [Google Scholar]
- PICKETT M. J., NELSON E. L. Speciation within the genus Brucella. IV. Fermentation of carbohydrates. J Bacteriol. 1955 Mar;69(3):333–336. doi: 10.1128/jb.69.3.333-336.1955. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pickett M. J., Pedersen M. M. Nonfermentative bacilli associated with man. II. Detection and identification. Am J Clin Pathol. 1970 Aug;54(2):164–177. doi: 10.1093/ajcp/54.2.164. [DOI] [PubMed] [Google Scholar]
- SAWYER S. J., MACDONALD J. B., GIBBONS R. J. Biochemical characteristics of Bacteroides melaninogenicus. A study of thirty-one strains. Arch Oral Biol. 1962 Nov-Dec;7:685–691. doi: 10.1016/0003-9969(62)90117-6. [DOI] [PubMed] [Google Scholar]
- Smith P. B., Tomfohrde K. M., Rhoden D. L., Balows A. API system: a multitube micromethod for identification of Enterobacteriaceae. Appl Microbiol. 1972 Sep;24(3):449–452. doi: 10.1128/am.24.3.449-452.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Starr S. E., Thompson F. S., Dowell V. R., Jr, Balows A. Micromethod system for identification of anaerobic bacteria. Appl Microbiol. 1973 May;25(5):713–717. doi: 10.1128/am.25.5.713-717.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sutter V. L., Carter W. T. Evaluation of media and reagents for indole-spot tests in anaerobic bacteriology. Am J Clin Pathol. 1972 Sep;58(3):335–338. doi: 10.1093/ajcp/58.3.335. [DOI] [PubMed] [Google Scholar]
- Washington J. A., 2nd, Yu P. K., Martin W. J. Evaluation of accuracy of multitest micromethod system for identification of Enterobacteriaceae. Appl Microbiol. 1971 Sep;22(3):267–269. doi: 10.1128/am.22.3.267-269.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]