Abstract
A "microgram assay" is described in which solid-phase enzyme-linked immunosorbent assay is used for the determination of specific rubella immunoglobulin G (IgG) antibody levels in micrograms per milliliter of serum. The quantitation was based on a standard curve obtained by using a reference serum, for which the specific IgG content was assayed by immunochemical purification. IgG was first purified and specific rubella antibodies were separated by an immunoadsorbent prepared by linking rubella virus antigens to Sepharose 4B. By using IgG-specific conjugate, the levels of specific rubella IgG antibodies could then be determined from clinical samples. Seronegative samples showed antibody levels less than 1 microgram/ml, whereas levels up to several hundred micrograms per milliliter were detected in some postinfection sera. The correlation between microgram antibody levels and hemagglutination inhibition titers was linear. The method offers a simple and sensitive antibody assay which could be used both for the laboratory diagnosis of acute rubella and for the evaluation of immunity.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Engvall E., Perlmann P. Enzyme-linked immunosorbent assay, Elisa. 3. Quantitation of specific antibodies by enzyme-labeled anti-immunoglobulin in antigen-coated tubes. J Immunol. 1972 Jul;109(1):129–135. [PubMed] [Google Scholar]
- Gravell M., Dorsett P. H., Gutenson O., Ley A. C. Detection of antibody to rubella virus by enzyme-linked immunosorbent assay. J Infect Dis. 1977 Oct;136 (Suppl):S300–S303. doi: 10.1093/infdis/136.supplement_2.s300. [DOI] [PubMed] [Google Scholar]
- Leinikki P., Pässilä S. Solid phase antibody assay by means of enzyme conjugated to anti-immunoglobulin. J Clin Pathol. 1976 Dec;29(12):1116–1120. doi: 10.1136/jcp.29.12.1116. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schuurs A. H., Van Weemen B. K. Enzyme-immunoassay. Clin Chim Acta. 1977 Nov 15;81(1):1–40. doi: 10.1016/0009-8981(77)90410-7. [DOI] [PubMed] [Google Scholar]
- Voller A., Bidwell D. E. A simple method for detecting antibodies to rubella. Br J Exp Pathol. 1975 Aug;56(4):338–339. [PMC free article] [PubMed] [Google Scholar]
- Voller A., Bidwell D. E. Enzyme-immunoassays for antibodies in measles, cytomegalovirus infections and after rubella vaccination. Br J Exp Pathol. 1976 Apr;57(2):243–247. [PMC free article] [PubMed] [Google Scholar]
- Wisdom G. B. Enzyme-immunoassay. Clin Chem. 1976 Aug;22(8):1243–1255. [PubMed] [Google Scholar]