Abstract
Background: Topical 5-fluorouracil has been reported to reduce adhesions in animal models of tenolysis. The purpose of this study was to investigate the effects of topical 5-fluorouracil on adhesion formation after tendon repairs were subjected to immediate postoperative rehabilitation in a canine model in vivo.
Methods: Sixty dogs were randomly assigned to either a 5-fluorouracil treatment (thirty dogs) or a control group (thirty dogs). Each treatment group was then divided into three survival time points: ten days, twenty-one days, and forty-two days. The second and fifth flexor digitorum profundus tendons from each dog were fully lacerated at the zone-II area and then were repaired. Passive motion therapy started at day 5 postoperatively and continued until the dogs were killed. The repaired tendons were evaluated for normalized work of flexion, gliding resistance, repair strength, gene expression for type-I and type-III collagen and transforming growth factor-β1, and histological appearance.
Results: The normalized work of flexion of the repaired tendons treated with 5-fluorouracil was significantly lower than that of the repaired tendons without 5-fluorouracil treatment at ten days. However, there was no significant difference between treated and untreated tendons at twenty-one and forty-two days. There was also no significant difference in gliding resistance, repair failure strength, or stiffness between treated and untreated tendons at any time point, or in the gross or histological appearance of adhesions at the time of killing. The expression of types-I and III collagen and transforming growth factor-β1 of the repaired tendon with 5-fluorouracil treatment was significantly lower than that of the tendons without treatment at ten days postoperatively, but not at twenty-one or forty-two days.
Conclusions: Although 5-fluorouracil treatment can reduce adhesions in in vivo models of tenolysis, this treatment had only a transient effect in an in vivo model of tendon repair that included passive motion.
Clinical Relevance: Topical 5-fluorouracil, at the dosing regimen tested in this study, does not appear to offer a major benefit over early postoperative motion protocols alone in the treatment of flexor tendon lacerations.
Adhesion formation following flexor tendon repair is an important clinical problem that can hinder hand function. Attempts at reducing postoperative adhesion formation have included low-friction surgical repair techniques1-3, early postoperative rehabilitation4-6, physical barriers to adhesion formation7-9, tendon surface lubrication10-12, and the use of pharmacological antiadhesive reagents13-15. 5-fluorouracil, an antimetabolite used in glaucoma filtration surgery, has been proposed as a possible antiadhesive pharmacological agent. The exposure of a surgical field to 5-fluorouracil produces a focal inhibition of scarring. One-time exposures to 5-fluorouracil, for as short a duration as five minutes, can have antiproliferative effects on fibroblasts for several days; this time frame may be adequate to inhibit adhesions following tendon repair and prior to beginning postoperative motion16. Several small-animal studies have described a benefit of 5-fluorouracil exposure after flexor tendon repair15,17,18; however, none of these animal models included immediate motion protocols. Immediate motion studies following the application of 5-fluorouracil will help to determine whether the effects of 5-fluorouracil are better than the results obtained with early motion therapy alone.
The purpose of this study was to investigate the effects of 5-fluorouracil on tendon repairs subjected to immediate postoperative rehabilitation in a canine model in vivo. We hypothesized that exposing the repaired tendon to topical 5-fluorouracil for five minutes would decrease tendon adhesions but not adversely affect intrinsic tendon healing, thus allowing for an early return to postoperative motion therapy. We also hypothesized that 5-fluorouracil would not result in an increase in tendon rupture or gapping compared with untreated tendons. Finally, we wished to determine whether 5-fluorouracil therapy offered a benefit over those already seen with postoperative motion therapy alone.
Materials and Methods
Experimental Design
The project was reviewed and approved by our Institutional Animal Care and Use Committee, and all National Institutes of Health animal care guidelines were followed. Sixty mongrel dogs weighing 20 to 25 kg were used. Each dog was randomly assigned to either the 5-fluorouracil treatment group (thirty dogs) or the control group (thirty dogs). Each group was then divided into three survival time points, ten days (ten dogs), twenty-one days (ten dogs), and forty-two days (ten dogs). The second and fifth flexor digitorum profundus tendons from each dog were fully lacerated at the zone-II D area19 and then repaired. The therapy started at day 5 postoperatively and continued until the dogs were killed. Following the killing of the dogs, one of the two repaired tendons in each paw was randomly assigned for biomechanical testing. Biomechanical testing consisted of evaluation of the work of flexion (ten dogs at each time point), gliding resistance, and repair strength. The other repaired digit was evaluated for gene expression for types-I and III collagen, transforming growth factor (TGF)-β1, and fibronectin (eight dogs at each time point) by reverse transcriptase-polymerase chain reaction and histological analysis (two dogs at each time point). The details of each test are described below.
Surgical Procedure and Postoperative Therapy
The dogs were anesthetized with intravenous ketamine (13 mg/kg) and diazepam (6 mg/kg) and maintained under anesthesia with 1.5% isoflurane. The selected forepaw was shaved, scrubbed with povidone-iodine, and sterilely draped. An elastic bandage was then used to exsanguinate the forelimb and act as a tourniquet for the procedure. In the second and fifth digits, the flexor digitorum profundus tendons were approached through a midlateral incision in the paw between the proximal and distal annular pulleys. With the given digit extended, the flexor digitorum profundus tendon was sharply transected 5 mm proximal to the distal edge of the proximal pulley. The tendon was subsequently repaired with a modified Pennington technique with 3-0 Ethibond (Ethicon, Somerville, New Jersey)3. A simple running circumferential epitenon suture of 6-0 nylon (Ethicon) was used to reinforce the repair.
The tendons in the treated group were given a single five-minute exposure of 5-fluorouracil at a concentration of 50 mg/mL, which was applied to the repair site. The dose of 50 mg/mL was chosen because this is an established dose in other mammalian models (the rabbit)15,18. Codman Neuropatties (Johnson and Johnson, Raynham, Massachusetts) were cut into 10 × 20-mm strips and soaked in 5-fluorouracil that had been placed into a sterile Petri dish. Soaked sponges were wrapped around the repair site for five minutes. The area was then thoroughly irrigated with 20 mL of 0.9% saline solution. In the control group, the sponge was soaked in saline solution and wrapped around the repair site for five minutes. Following tendon repair, a radial neurectomy proximal to the triceps innervation was performed to prevent postoperative weight-bearing on the operative limb. The wound was closed in a standard fashion. The paw and forearm were dressed and immobilized with waterproof casting tape to maintain 45° of wrist flexion and a neutral position of the digit joints after surgery. The operatively treated limb was placed in a custom sling fabricated from a denim material. With the sling, weight-bearing of the limb was prevented.
Beginning on postoperative day 5, rehabilitation was performed on the dogs with use of a modified synergistic protocol20 twice daily, seven days a week, until the dogs were killed. During therapy, the dogs were constrained with a custom-made sling system, holding the involved forelimb extended without weight-bearing. Passive motion of the elbow and wrist of the operatively treated forelimb was first performed for ten repetitions of flexion-extension to prevent any joint contracture due to immobilization. Then, therapy was performed with proximal interphalangeal and distal interphalangeal joint flexion and metacarpophalangeal and wrist extension, and proximal interphalangeal and distal interphalangeal joint extension with metacarpophalangeal and wrist flexion for ten times in each operatively treated digit. The dogs were killed with an overdose of pentobarbital at postoperative day 10, 21, or 42.
Measurement of Digit Work of Flexion
To quantitatively evaluate the resistance generated by adhesions, the work of flexion was measured in the digit12. Briefly, the second and fifth digits in both operatively treated and nonoperatively treated paws were harvested. The flexor digitorum profundus tendons were carefully exposed at the proximal metacarpal level, transected, and sutured to a cable that connected to a load transducer. The repaired tendon within zone II was not exposed. A Kirschner wire was inserted longitudinally through the metacarpal bone to fix the metacarpophalangeal joint in extension. A T-shaped piece of hardware with a pair of reflective markers (2 mm in diameter) was pinned to the proximal, middle, and distal phalanges, respectively. The prepared digit was then mounted on the testing device by fixing the proximal Kirschner wire to a custom jig. The testing device consisted of a testing frame, actuator, linear potentiometer, and one load transducer. A 0.5-N weight was attached to the extensor tendon to ensure full extension of the digit as a starting position, and to apply an initial tension of 0.1 N to the flexor digitorum profundus tendon (Fig. 1).
Fig. 1.
The work-of-flexion tester. 1 = the actuator, 2 = the load transducer, 3 = the T-shaped hardware with a pair of reflective markers mounted on the distal, middle, and proximal phalanxes, 4 = the specimen, 5 = the weight, 6 = two cameras of the Motion Analysis System, and 7 = the frame.
The actuator pulled the tendon proximally at a rate of 2 mm/sec, causing flexion of the digit. The tendon excursion was determined by the collateral normal digit tendon excursion during full range of motion of the proximal interphalangeal and distal interphalangeal joint. Data from the linear potentiometer and the proximal load transducer were recorded at 60 Hz. During testing, motion of the digit was recorded simultaneously (from extension to flexion) by Motion Analysis System software (Motion Analysis, Santa Rosa, California). Work-of-flexion data were calculated from the tendon displacement versus loading curve during flexion of the digit, and then were normalized (divided) by total proximal interphalangeal and distal interphalangeal joint motion angle at the point when the distal interphalangeal joint reached 40°. If the distal interphalangeal joint could not reach a 40° arc of motion, maximum proximal interphalangeal and distal interphalangeal joint motions were used to normalize the work of flexion21.
Tendon Gliding Resistance Measurement
Following the work-of-flexion measurement, the tendons were further dissected, keeping the proximal pulley intact. The gliding resistance between the tendon graft and the proximal pulley was then measured with use of a custom tendon-pulley friction testing device, as previously described22. Briefly, the dissected proximal phalanx with proximal pulley was mounted in a custom jig with the palmar side upward. Two tensile load transducers were attached to the proximal and distal ends of the flexor digitorum profundus tendon with the repair site between them. A mechanical actuator with a linear potentiometer was connected to the proximal flexor digitorum profundus tendon, and a 500-g weight was attached to the distal end of the flexor digitorum profundus tendon. The tendon was pulled proximally by the actuator against the weight at a rate of 2.0 mm/sec. The actuator movement was then reversed, causing the tendon to be pulled distally by the weight. The gliding resistance of the repaired tendon against the pulley was calculated as the difference between two load transducers during tendon gliding23.
Measurement of Repair Strength
To measure breaking strength, the tendons, following frictional testing, were secured in a servohydraulic testing machine and distracted to failure at a rate of 20 mm/min. A differential variable reluctance transducer (DVRT; MicroStrain, Williston, Vermont) was attached to the tendon spanning the repair site to measure gap formation during testing. Tensile force, grip-to-grip displacement, and gap displacement measured by the DVRT transducer were collected at a rate of 20 Hz. Throughout testing, the tendons were kept moist by spraying with physiologic saline solution. Maximum breaking force was recorded. In addition, a regression line was fit to the linear region of the force versus gap formation (as measured by the DVRT transducer) to measure the resistance to gap formation.
Reverse Transcriptase-Polymerase Chain Reaction Quantification of Metabolic and Functional Markers
After gross evaluation, the tendons were processed for real-time reverse transcriptase-polymerase chain reaction to measure the gene expression for type-I collagen, type-III collagen, fibronectin, and TGF-β1. Briefly, each specimen was homogenized in TRIzol reagent (Invitrogen, Carlsbad, California) with a Mikro-Dismembrator (B. Braun Biotech International, Melsungen, Germany). Following the addition of chloroform (Sigma-Aldrich, St. Louis, Missouri), the homogenized tissue samples were centrifuged for ten minutes at 12,000 g, and the upper aqueous phase was transferred to a clean tube. Total RNA from the aqueous phase was precipitated by mixing with isopropyl alcohol (Sigma-Aldrich) and collected by centrifugation at 12,000 g for fifteen minutes. The above extracted RNA was purified with an RNeasy Mini spin column (QIAGEN, Valencia, California). Any potential remaining DNA was further removed by DNase treatment. The RNA concentration was determined with use of a RiboGreen RNA Quantitation Kit (Molecular Probes, Eugene, Oregon). RNA was reverse-transcribed into single-stranded cDNA with a random primer with use of a Transcriptor First Strand cDNA Synthesis Kit (Roche, Mannheim, Germany). The reverse transcriptase was inactivated by heating to 85°C for five minutes. The expression of type-I collagen, type-III collagen, fibronectin, and TGF-β1 was quantified with LightCycler FastStart DNA Master SYBR Green I kit (Roche) in a LightCycler instrument (Roche). Glyceraldehyde-3-phosphate dehydrogenase (GAPDH) served as the house-keeping gene. The polymerase chain reaction primers designed from canine-specific cDNA sequences are listed in Table I.
TABLE I.
The Sequences of Polymerase Chain Reaction Primers of Canine Genes and the Length of Amplicons
| Gene | Accession No. | Primers (5′ to 3′) | Size (bp) |
|---|---|---|---|
| Type-I collagen | AF153062 | TGGTTCTCCTGGCAAAGAT | 232 |
| ATCACCGGGTTCACCTTTA | |||
| Type-III collagen | XM_535997 | ACAGCAGCAAGCTATTGAT | 156 |
| GGACAGTCTAATTCTTGTTCGT | |||
| Fibronectin | CFU52106 | GATGACTCGTGCTTCGAC | 183 |
| CTTCTCGCCAATCTTGTAGTT | |||
| TGF-β1 | NM_001003309 | ACCATTCATGGCATGAACC | 174 |
| CAGATCCTTGCGGAAGTC |
Histological Analysis
After gross evaluation, two repaired flexor digitorum profundus tendons from each group were carefully dissected from the flexor sheath, fixed in 10% formalin, embedded in paraffin, sectioned longitudinally, and stained with hematoxylin and eosin. Because only two tendons were used in each group, we did not attempt to quantify any of the histological observations.
Statistical Analysis
Animal numbers were determined on the basis of a power analysis and previously published studies with use of this canine model5,12. With a sample size of ten, we had 80% power at a significance level of p < 0.05 to detect a 30% change in work of flexion and ultimate strength and 35% change in gliding resistance, which would be considered large changes. The thirty dogs in the control group also served as a control group for other experimental studies not reported in this manuscript. The data obtained from work of flexion and frictional force were analyzed with use of two-factor (time and treatment) analysis of variance, followed by the Tukey Studentized range (HSD; honestly significant difference) post hoc test to compare control, 5-fluorouracil-treated, and normal digits at three time points (day 10, day 21, and day 42). The Fisher exact test was used for the tendon rupture and gap comparisons. In all cases, a level of p < 0.05 was considered to be significant.
Source of Funding
This study was funded by a grant from the National Institutes of Health/National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR44391).
Results
The rates of tendon rupture (two [3%] in the control group and three [5%] in the 5-fluorouracil group) and tendon gaps of >3 mm (ten [17%] in controls and twelve [20%] in the 5-fluorouracil group) were found to be similar (p > 0.05). The 5-fluorouracil group had a higher number of tendons with a small (1-to-2-mm) gap (seven; 12%) compared with the controls (three; 5%), although this difference did not reach significance (p > 0.05).
Figure 2 illustrates the results of normalized work of flexion (nWOF) at the three examined time points. The normalized work of flexion of the 5-fluorouracil-treated tendons was significantly lower than the repaired tendons without 5-fluorouracil treatment at the day-10 time point (p < 0.05), but not at day 21 or day 42. The normalized work of flexion of 5-fluorouracil-treated tendons significantly increased with time, so that the normalized work of flexion in the day-10 group was significantly lower than that in the day-21 group, which in turn was significantly lower than the day-42 group (p < 0.05). In the repaired tendons without 5-fluorouracil, although the normalized work of flexion of the day-42 group was significantly increased compared with the day-10 and day-21 groups (p < 0.05), there was no significant difference between the day-10 and day-21 groups.
Fig. 2.
The work of flexion normalized by proximal interphalangeal and distal interphalangeal joint angle (nWOF) in repaired tendons with 5-fluorouracil (5-FU) treatment or repaired tendons without such treatment (control) and a normal digit as well at three time points: ten, twenty-one, and forty-two days. Bars with similar letters at the top (i.e., a and a) have no significant difference; however, bars with different letter designations (i.e., a and b) indicate there is a significant difference (p < 0.05) between them. The bars and I-bars indicate the mean and the standard deviation.
The gliding resistance of all of the repaired tendons was significantly higher than the normal flexor digitorum profundus tendons (p < 0.05). However, there was no significant difference in gliding resistance among any repaired tendon groups, regardless of surface treatment or time point (Fig. 3). The maximum force to break the repaired tendons at forty-two days was significantly higher than that at ten days and twenty-one days in both treated and untreated repaired tendons (p < 0.01). There was no significant difference (p > 0.05) between 5-fluorouracil treatment and untreated repaired tendons and no significant interaction between the two variables (p > 0.05) (Fig. 4). Similarly, the day-42 tendons had a significantly higher resistance to gap formation than did the day-10 and day-21 tendons (p < 0.01) (Fig. 5). Again, no significant difference was noted between 5-fluorouracil-treated and control tendons.
Fig. 3.
The gliding resistance (GR) of the repaired tendons with 5-fluorouracil (5-FU) treatment or without such treatment (control) and a normal digit as well at three time points: ten, twenty-one, and forty-two days. Bars with similar letters at the top (i.e., a and a) have no significant difference; however, bars with different letter designations (i.e., a and b) indicate there is a significant difference (p < 0.05) between them. The bars and I-bars indicate the mean and the standard deviation.
Fig. 4.
Maximum force of the repaired tendons with 5-fluorouracil (5-FU) treatment or without such treatment (control) and a normal digit as well at three time points: ten, twenty-one, and forty-two days. Bars with similar letters at the top (i.e., a and a) have no significant difference; however, bars with different letter designations (i.e., a and b) indicate there is a significant difference (p < 0.05) between them. The bars and I-bars indicate the mean and the standard deviation.
Fig. 5.
Resistance to gap formation of the repaired tendons with 5-fluorouracil (5-FU) treatment or without such treatment (control) and a normal digit as well at three time points: ten, twenty-one, and forty-two days. Bars with similar letters at the top (i.e., a and a) have no significant difference; however, bars with different letter designations (i.e., a and b) indicate there is a significant difference (p < 0.05) between them. The bars and I-bars indicate the mean and the standard deviation.
The expression of types-I and III collagen and TGF-β1 of the repaired tendons with 5-fluorouracil treatment was significantly lower than that of the tendons without treatment at ten days postoperatively (p < 0.05). Type-I collagen expression of the 5-fluorouracil group was significantly higher than that of the untreated group at forty-two days (p < 0.05). In a comparison of the different time points, the expression of types-I and III collagen after 5-fluorouracil treatment was significantly increased in the day-42 group compared with the day-10 and day-21 groups (p < 0.05) (Fig. 6).
Fig. 6.
Reverse transcriptase-polymerase chain reaction analysis of the expression of type-I and III collagen and TGF-β1 of the repaired tendons with 5-fluorouracil (5-FU) treatment or without such treatment (control) and a normal digit as well at three time points: ten, twenty-one, and forty-two days. A: Type-I collagen expression. B: Type-III collagen expression. C: Fibronectin expression. D: TGF-β1 expression. Bars with similar letters at the top (i.e., a and a) have no significant difference; however, bars with different letter designations (i.e., a and b) indicate there is a significant difference (p < 0.05) between them. The bars and I-bars indicate the mean and the standard deviation.
Histologically, the healing of tendons in the control and 5-fluorouracil-treated tendons improved similarly with the increase in postoperative time. The epitenon cells increased at the repair site and migrated into the laceration over time. There appeared to be fewer cells on the surface of the day-10 5-fluorouracil-treated tendons than there were on the day-10 control tendons. On the basis of the two tendons evaluated in each treatment group, there were no dramatic differences in histological appearance between control and 5-fluorouracil tendons at twenty-one or forty-two days (Fig. 7).
Fig. 7.
Histological sections with hematoxylin and eosin staining show that in saline-solution-treated, control day-10 repaired tendons, the epitenon cells at the repair site proliferated (A), but the epitenon cells were rarely seen in the 5-fluorouracil surface treatment tendons (B). The epitenon cells increased in both treated and untreated tendons after forty-two days (C and D).
Discussion
5-fluorouracil is one of the antimetabolites that interferes with DNA production and therefore cell proliferation. Besides its use in cancer treatment, 5-fluorouracil has also been shown to inhibit the formation of postoperative flexor tendon adhesions15,17. This effect could be detrimental to intrinsic tendon healing, especially in the clinical setting where early motion protocols can subject tendons to strain at the repair site. In a study examining the antiadhesive effects of 5-flourouracil in a chicken model, we found that higher doses of 5-fluorouracil resulted in an increase in inflammation and were less effective in preventing adhesions than were lower doses of 5-fluorouracil15. Subsequent studies found no detrimental effect on gap formation or rupture strength, but they were limited to a rabbit model in which tendons were immobilized throughout the healing course18. While these studies have helped to establish 5-fluorouracil as a potential antiadhesive agent with use of small-animal models with a postoperative immobilization protocol15,17,18, one must still verify that repaired tendons exposed to 5-fluorouracil when they are subjected to early motion protocols show no signs of increased tendon rupture or gap formation. In addition, in order to translate this pharmacotherapy to the clinical setting, one must establish that 5-fluorouracil provides a benefit over early motion therapy alone.
In the current study, we found that the antiadhesive effect of 5-fluorouracil, which was indirectly measured by the work of flexion24, was only beneficial at the early stages of tendon healing (day 10) and that these beneficial effects were not observed at day 21 or 42. Our results also showed that 5-fluorouracil inhibited the gene expression of types-I and III collagen and TGF-β1 compared with untreated tendons at the early time point only. With time, this antimetabolic effect gradually subsided and expression of type-I collagen as well as TGF-β1 rebounded. This might be the reason that we did not observe any difference in adhesion and healing strength between the two groups at later time intervals of healing.
5-fluorouracil can reduce adhesion formation by inhibiting ingrowth of connective tissue from the digital sheath. It may also postpone healing by affecting the proliferation and migration of cells from the epitenon. We found that tendon strength increased over the course of six weeks to an average value of 69 N for the control repaired tendons and 63 N for the 5-fluorouracil-treated repaired tendons. Structurally, the stiffness of the 5-fluorouracil-treated tendons was not significantly different from that of the control tendons. In addition, the resistance to gap formation was not significantly different between the two groups.
Histologically, there appeared to be fewer cells on the surface of tendons in the day-10 5-fluorouracil group than were present on the surface of tendons in the day-10 control group. Although this observation was associated with gene expression levels at ten days, as mentioned above, there was no significant difference in the tensile strength of the repaired tendons between the treated and untreated groups. This may be due to the suture holding power, which is the major factor determining tensile strength in the early stages of tendon repair, masking any differences in the intrinsic tendon healing strength. However, the single five-minute exposure of 5-fluorouracil at a concentration of 50 mg/mL also had little effect on tendon healing at twenty-one or forty-two days, when the tendon healing strength might be more likely to contribute to breaking strength.
The measurements of work of flexion and gliding resistance are commonly used to evaluate digit function in animal studies of flexor tendon repair1,25. Gliding resistance of the repaired tendon directly reflects the smoothness and lubrication of the tendon surface. Together, these measures allow a more precise quantification of adhesion formation and, of course, directly measure tendon mechanics. Especially early in the tendon healing process, low gliding resistance and work of flexion are clinically extremely important, as they provide a lower limit of the force necessary to initiate tendon movement. The upper bound, the breaking strength of the repair construct, is quite limited in the early phases of tendon healing, so a low gliding resistance and low work of flexion increase the size of the so-called safe zone21, in which the tendon can move without jeopardizing the mechanical integrity of the repair. Low-friction suture techniques have produced fewer adhesions following flexor tendon repair in a canine in vivo model2. In the current study, the modified Pennington suture was chosen because of its low frictional force and high tensile strength characteristics3. We did not observe any effect of the 5-fluorouracil on tendon surface lubrication.
One limitation of this study is that mechanical strength was measured following both the gliding resistance test and the work-of-flexion measurement. This sequential testing might have affected the results. It was not possible to randomize the testing procedures within the same digit because of the sequentially disruptive assessment. However, even as the last testing procedure, the tendon tensile strength was comparable with the previous published data26,27, suggesting that any effect of the testing sequence was limited. A second weakness of the investigation is that we studied only a single concentration of 5-fluorouracil. The 5-fluorouracil concentration and treatment duration were based on published results with use of a small-animal model; the ideal dose and duration might be lower than optimal for a canine study. A final weakness of the investigation is that we did not study all cytokines involved in tendon healing; we chose instead to focus on what we considered some key measures: TGF-β1, collagen type-I, and collagen type-III.
In conclusion, 5-fluorouracil at the dosing regimen tested in this canine study does not appear to offer a major benefit over early postoperative motion protocols alone in the treatment of flexor tendon injuries. 
Disclosure: In support of their research for or preparation of this work, one or more of the authors received, in any one year, outside funding or grants in excess of $10,000 from the National Institutes of Health/National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR44391). Neither they nor a member of their immediate families received payments or other benefits or a commitment or agreement to provide such benefits from a commercial entity.
Investigation performed at the Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic College of Medicine, Rochester, Minnesota
References
- 1.Momose T, Amadio PC, Zhao C, Zobitz ME, Couvreur PJ, An KN. Suture techniques with high breaking strength and low gliding resistance: experiments in the dog flexor digitorum profundus tendon. Acta Orthop Scand. 2001;72:635-41. [DOI] [PubMed] [Google Scholar]
- 2.Zhao C, Amadio PC, Momose T, Couvreur P, Zobitz ME, An KN. The effect of suture technique on adhesion formation after flexor tendon repair for partial lacerations in a canine model. J Trauma. 2001;51:917-21. [DOI] [PubMed] [Google Scholar]
- 3.Tanaka T, Amadio PC, Zhao C, Zobitz ME, Yang C, An KN. Gliding characteristics and gap formation for locking and grasping tendon repairs: a biomechanical study in a human cadaver model. J Hand Surg Am. 2004;29:6-14. [DOI] [PubMed] [Google Scholar]
- 4.Silfverskiöld KL, May EJ, Törnvall AH. Tendon excursions after flexor tendon repair in zone. II: Results with a new controlled-motion program. J Hand Surg Am. 1993;18:403-10. [DOI] [PubMed] [Google Scholar]
- 5.Zhao C, Amadio PC, Momose T, Couvreur P, Zobitz ME, An KN. Effect of synergistic wrist motion on adhesion formation after repair of partial flexor digitorum profundus tendon lacerations in a canine model in vivo. J Bone Joint Surg Am. 2002;84:78-84. [PubMed] [Google Scholar]
- 6.Klein L. Early active motion flexor tendon protocol using one splint. J Hand Ther. 2003;16:199-206. [DOI] [PubMed] [Google Scholar]
- 7.Frykman E, Jacobsson S, Widenfalk B. Fibrin sealant in prevention of flexor tendon adhesions: an experimental study in the rabbit. J Hand Surg Am. 1993;18:68-75. [DOI] [PubMed] [Google Scholar]
- 8.Burns JW, Skinner K, Colt MJ, Burgess L, Rose R, Diamond MP. A hyaluronate based gel for the prevention of postsurgical adhesions: evaluation in two animal species. Fertil Steril. 1996;66:814-21. [PubMed] [Google Scholar]
- 9.Shih HN, Fang JF, Chen JH, Yang CL, Chen YH, Sung TH, Shih LY. Reduction in experimental peridural adhesion with the use of a crosslinked hyaluronate/collagen membrane. J Biomed Mater Res B Appl Biomater. 2004;71:421-8. [DOI] [PubMed] [Google Scholar]
- 10.Hagberg L. Exogenous hyaluronate as an adjunct in the prevention of adhesions after flexor tendon surgery: a controlled clinical trial. J Hand Surg Am. 1992;17:132-6. [DOI] [PubMed] [Google Scholar]
- 11.Hills BA. Boundary lubrication in vivo. Proc Inst Mech Eng H. 2000;214:83-94. [DOI] [PubMed] [Google Scholar]
- 12.Zhao C, Sun YL, Amadio PC, Tanaka T, Ettema AM, An KN. Surface treatment of flexor tendon autograft with carbodiimide-derivatized hyaluronic acid. An in vivo canine model. J Bone Joint Surg Am. 2006;88:2181-91. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Namba J, Shimada K, Saito M, Murase T, Yamada H, Yoshikawa H. Modulation of peritendinous adhesion formation by alginate solution in a rabbit flexor tendon model. J Biomed Mater Res B Appl Biomater. 2007;80:273-9. [DOI] [PubMed] [Google Scholar]
- 14.Occleston NL, Alexander RA, Mazure A, Larkin G, Khaw PT. Effects of single exposures to antiproliferative agents on ocular fibroblast-mediated collagen contraction. Invest Ophthalmol Vis Sci. 1994;35:3681-90. [PubMed] [Google Scholar]
- 15.Moran SL, Ryan CK, Orlando GS, Pratt CE, Michalko KB. Effects of 5-fluorouracil on flexor tendon repair. J Hand Surg Am. 2000;25:242-51. [DOI] [PubMed] [Google Scholar]
- 16.Khaw PT, Sherwood MB, MacKay SL, Rossi MJ, Schultz G. Five-minute treatments with fluorouracil, floxuridine, and mitomycin have long-term effects on human Tenon's capsule fibroblasts. Arch Ophthalmol. 1992;110:1150-4. [DOI] [PubMed] [Google Scholar]
- 17.Akali A, Khan U, Khaw PT, McGrouther AD. Decrease in adhesion formation by a single application of 5-fluorouracil after flexor tendon injury. Plast Reconstr Surg. 1999;103:151-8. [DOI] [PubMed] [Google Scholar]
- 18.Cerovac S, Afoke A, Akali A, McGrouther DA. Early breaking strength of repaired flexor tendon treated with 5-fluorouracil. J Hand Surg Br. 2001;26:220-3. [DOI] [PubMed] [Google Scholar]
- 19.Okuda Y, Gorski JP, An KN, Amadio PC. Biochemical, histological, and biomechanical analyses of canine tendon. J Orthop Res. 1987;5:60-8. [DOI] [PubMed] [Google Scholar]
- 20.Tanaka T, Amadio PC, Zhao C, Zobitz ME, An KN. Flexor digitorum profundus tendon tension during finger manipulation. J Hand Ther. 2005;18:330-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Zhao C, Amadio PC, Tanaka T, Yang C, Ettema AM, Zobitz ME, An KN. Short-term assessment of optimal timing for postoperative rehabilitation after flexor digitorum profundus tendon repair in a canine model. J Hand Ther. 2005;18:322-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Uchiyama S, Amadio PC, Coert JH, Berglund LJ, An KN. Gliding resistance of extrasynovial and intrasynovial tendons through the A2 pulley. J Bone Joint Surg Am. 1997;79:219-24. [DOI] [PubMed] [Google Scholar]
- 23.Zhao C, Amadio PC, Zobitz ME, An KN. Gliding characteristics of tendon repair in canine flexor digitorum profundus tendons. J Orthop Res. 2001;19:580-6. [DOI] [PubMed] [Google Scholar]
- 24.Zhao CF, Amadio PC, Berglund L, Zobitz ME, An KN. A new testing device for measuring gliding resistance and work of flexion in a digit. J Biomech. 2003;36:295-9. [DOI] [PubMed] [Google Scholar]
- 25.Zhao C, Amadio PC, Momose T, Zobitz ME, Couvreur P, An KN. Remodeling of the gliding surface after flexor tendon repair in a canine model in vivo. J Orthop Res. 2002;20:857-62. [DOI] [PubMed] [Google Scholar]
- 26.Silva MJ, Brodt MD, Boyer MI, Morris TS, Dinopoulos H, Amiel D, Gelberman RH. Effects of increased in vivo excursion on digital range of motion and tendon strength following flexor tendon repair. J Orthop Res. 1999;17:777-83. [DOI] [PubMed] [Google Scholar]
- 27.Wada A, Kubota H, Miyanishi K, Hatanaka H, Miura H, Iwamoto Y. Comparison of postoperative early active mobilization and immobilization in vivo utilising a four-strand flexor tendon repair. J Hand Surg Br. 2001;26:301-6. [DOI] [PubMed] [Google Scholar]