Skip to main content
Ophthalmic Research logoLink to Ophthalmic Research
. 2009 Jul 1;42(3):125–127. doi: 10.1159/000226258

A Simple Nonmydriatic Self-Retinal Imaging Procedure Using a Kowa Genesis-D Hand-Held Digital Fundus Camera

Ugur Ozerdem 1,*
PMCID: PMC2784005  NIHMSID: NIHMS75412  PMID: 19571602

Abstract

Research on vascular adaptation to microgravity in the central nervous system requires a simple, noninvasive, direct imaging technique that can be performed with compact equipment. In this report we describe a practical, nonmydriatic, retinal self-imaging technique using a Kowa Genesis-D hand-held digital camera and a Black and Decker laser level. This simple technique will be useful to clinical physiologists conducting microgravity research, as well as for the studies of high-altitude medicine and aviation physiology.

Key Words: Central nervous system, Fundus, Retina, Self-imaging, Artery, Vein, Head-down tilt, Microgravity

Introduction

Evaluating microgravity-induced vascular changes in the central nervous system during spaceflight or during simulated microgravity research is hampered by the inability to view structures directly due to the barrier posed by the skull bones [1]. However, the retina (an outgrowth of the brain) as well as its vessels and optic nerve are visible directly through the pupil of the eye, and can be imaged with any digital fundus camera [2, 3].

Blood and tissue fluid shifts associated with weightlessness offer unique opportunities to study perturbations in vascular transmural pressure changes and associated edema in the upper body (face, eyelids, vocal cords, brain) during space explorations. In a microgravity (or simulated microgravity) environment capillary pressure (Pc) increases in the head and neck. The reason for the increase of Pc in the upper body is because hydrostatic fluid pressure within the vasculature behaves like a vertical column of water and is affected by gravity. The difference between Pc and interstitial fluid pressure is greater in magnitude in the upper body parts during space flight [4, 5]. An increase in Pc in the upper body counteracts interstitial fluid pressure and therefore increases net transcapillary fluid leakage and edema.

High-resolution, hand-held digital fundus cameras have recently become available for retinal imaging. Kowa Genesis-D is a compact, lightweight, hand-held fundus camera. This system is equipped with a built-in digital camera which provides 2.0 million pixels of resolution and an LCD monitor screen. In this brief report we describe a simple, noninvasive technique for retinal self-imaging that can be used in clinical physiology to evaluate the adaptive changes in retinal vasculature (central nervous system vasculature) in microgravity.

Materials, Methods and Results

A Kowa Genesis-D fundus camera (serial No. 1501500288, Tokyo, Japan) was used as a hand-held digital fundus camera. The weight of the camera is 1,070 g and the dimensions are 74.5 mm (width) × 197 mm (depth) × 278.5 mm (height). This camera has approximately 30° of horizontal angle of view. Since the angular distance between fovea and optic nerve is approximately 15° [6], a 7.5° adduction of the eye was calculated to translate to a 7.5° temporal displacement of the macula off the optical axis. A simple laser level (Black and Decker, DL220S, Towson, Md., USA) was used for aligning the eye 7.5° nasally (adduction) so that both optic nerve head and macula were approximately located in the center of the digital image frame obtained with this camera. The laser streak was projected onto a wall in a darkroom 100 cm away from the right eye. The wall was viewed through the objective lens of the camera which functioned as an ocular eyepiece for this imaging technique. The eyes were dark-adapted for 5 min in the dark room. The forehead rest of the camera was placed on the frontal bone. The original eyepiece of the camera served as an objective lens to view the laser streak on the wall (fig. 1a). The laser streak was then shifted on the wall to project 13 cm off the optical axis, which was represented by the triangular notch of the picture frame in this particular camera. The 13-cm horizontal displacement of laser streak was calculated by using basic trigonometry (100 cm × tan 7.5° = 13 cm). The right eye then gazed at the laser streak on the wall while the camera position on the forehead was kept constant. The shutter on the camera handle was switched on by using the right thumb to capture the image (fig. 1b). The entire procedure, including 5 min of the dark adaptation period, took less than 7 min. The JPEG image obtained was of sufficient quality to apply NIH image J 1.39t image analysis software to quantify the relative size of major vascular structures (retinal arteries and veins) representative of central nervous system vasculature. A practical application of this technique in a simulated microgravity model with 6° head-down tilt is shown in figure 2.

Fig. 1.

Fig. 1

a The laser streak of Black and Decker, DL220S, level was projected onto a wall in a dark room 100 cm away from the right eye, 13 cm medial (nasal) to the optical axis, represented by the perpendicular dashed line drawn from the triangular notch at the top of the picture frame. A 13-cm nasal displacement of the laser streak on the dark wall from the optical axis at 100 cm corresponds to approximately 7.5° of temporal displacement of the macula from the optical axis in the fundus photograph seen in b. b Optic nerve head, major vessel and macula in a single photographic frame are shown.

Fig. 2.

Fig. 2

A practical application of the selfretinal vascular imaging technique in microgravity research. a The same image as in figure 1b was compared with the selffundus photograph obtained during bedrest, after 45 min of supine bedrest with 6° of head-down tilt. Caliber of the superior temporal retinal artery (stra) and superior temporal retinal vein (strv) in the same anatomic location (arrows) was measured with NIH image J 1.39t image analysis software in pixels. The measurement reveals a wall diameter of 25,554 and 29,120 pixels for stra and strv, respectively, in standing position. b Following 45 min of supine bedrest with 6° of head-down tilt (HDT) a reduction of vascular caliber to 24,498 and 27,893 pixels was noted for stra and strv, respectively.

Discussion

In the late 1970s, Kowa RC-2 cameras were modified successfully by the addition of custom-made bite plates to position the camera, attaching cross-hair targets, and a focusing light in the view finder (ocular eyepiece) [7]. Our technique uses a more advanced camera which requires only a miniature external laser level (Black and Decker, DL220S), and no modifications to the camera hardware. This easy-to-apply, nonmydriatic procedure can be used by crew members without any compromising vision or sacrificing safety in situations where payload and imaging time are limited (such as spacecraft, aircraft, and tent of a mountaineer physiologist). The compactness of this hand-held fundus camera coupled with the simplicity of the procedure we describe makes it possible for anyone who can use a standard digital camera to perform retinal self-imaging in a darkroom with a wall in 100 cm distance. Therefore, changes in central nervous system (retinal) vasculature can be monitored in locations where it is not feasible to use a conventional retinal camera, and without the expertise of a specialist/ophthalmologist. Oral fluorescein angiography [8] can be accomplished with simply taping excitation and emission filters (Roscolux transparent filters, Rosco Laboratories Inc., Stamford, Conn., USA) in the light pathway of the projecting prism and objective lens, respectively, in this camera.

The neurosensory retina is an embryological derivative of the diencephalon, and is thus part of the central nervous system, as is the optic nerve. The retinal artery is a branch of ophthalmic artery, which is the first branch of internal carotid artery. Using the simple, retinal self-imaging procedure and equipment described herein, we expect that changes in central nervous system vessels can be studied more extensively thereby contributing significantly to the fields of microgravity research, aviation physiology and in high-altitude medicine.

Acknowledgments

We are grateful to US Department of Defense-CDMRP (BC084220), NIH-Eunice Kennedy Shriver National Institute of Child Health and Human Development (R21-HD052126), NIH-National Institute of Biomedical Imaging and Bioengineering (R03EB006746), and University of California, Tobacco-Related Disease Research Program (TRDRP 16IT-0212) for their support of our research. This brief report is dedicated to a stellar clinician-scientist and an outstanding mentor, Dr. William R. Freeman, who has contributed vastly to vitreoretinal imaging, and surgery fields.

References

  • 1.Ueno T, Ballard RE, Macias BR, Yost WT, Hargens AR. Cranial diameter pulsations measured by non-invasive ultrasound decrease with tilt. Aviat Space Environ Med. 2003;74:882–885. [PubMed] [Google Scholar]
  • 2.Miller N, Drachman DA. The optic nerve: a window into diseases of the brain? Neurology. 2006;67:1742–1743. doi: 10.1212/01.wnl.0000250233.41910.2f. [DOI] [PubMed] [Google Scholar]
  • 3.Msall ME. The retina as a window to the brain in vulnerable neonates. Pediatrics. 2006;117:2287–2289. doi: 10.1542/peds.2006-0385. [DOI] [PubMed] [Google Scholar]
  • 4.Watenpaugh DE, Hargens AR. The cardiovascular system in microgravity. In: Fregly MJ, Blatteis CM, editors. Handbook of Physiology: Enviromental Physiology. New York: Oxford University Press; 1996. pp. 631–674. [Google Scholar]
  • 5.Parazynski SE, Hargens AR, Tucker B, Aratow M, Styf J, Crenshaw A. Transcapillary fluid shifts in tissues of the head and neck during and after simulated microgravity. J Appl Physiol. 1991;71:2469–2475. doi: 10.1152/jappl.1991.71.6.2469. [DOI] [PubMed] [Google Scholar]
  • 6.Rohrschneider K. Determination of the location of the fovea on the fundus. Invest Ophthalmol Vis Sci. 2004;45:3257–3258. doi: 10.1167/iovs.03-1157. [DOI] [PubMed] [Google Scholar]
  • 7.Philpott DE, Bailey PF, Harrison G, Turnbill C. Modification of a Kowa RC-2 fundus camera for self-photography without the use of mydriatics. Brain Res Bull. 1979;4:123–125. doi: 10.1016/0361-9230(79)90066-2. [DOI] [PubMed] [Google Scholar]
  • 8.Watson AP, Rosen ES. Oral fluorescein angiography: reassessment of its relative safety and evaluation of optimum conditions with use of capsules. Br J Ophthalmol. 1990;74:458–461. doi: 10.1136/bjo.74.8.458. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Ophthalmic Research are provided here courtesy of Karger Publishers

RESOURCES