Skip to main content
Springer logoLink to Springer
. 2008 Oct 17;19(3):731–744. doi: 10.1007/s00330-008-1194-4

Combined FDG-PET/CT for the detection of unknown primary tumors: systematic review and meta-analysis

Thomas C Kwee 1,, Robert M Kwee 2
PMCID: PMC2816234  PMID: 18925401

Abstract

The aim of this study was to systematically review and meta-analyze published data on the diagnostic performance of combined 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in the detection of primary tumors in patients with cancer of unknown primary (CUP). A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Methodological quality of the included studies was assessed. Reported detection rates, sensitivities and specificities were meta-analyzed. Subgroup analyses were performed if results of individual studies were heterogeneous. The 11 included studies, comprising a total sample size of 433 patients with CUP, had moderate methodological quality. Overall primary tumor detection rate, pooled sensitivity and specificity of FDG-PET/CT were 37%, 84% (95% CI 78–88%) and 84% (95% CI 78–89%), respectively. Sensitivity was heterogeneous across studies (P = 0.0001), whereas specificity was homogeneous across studies (P = 0.2114). Completeness of diagnostic workup before FDG-PET/CT, location of metastases of unknown primary, administration of CT contrast agents, type of FDG-PET/CT images evaluated and way of FDG-PET/CT review did not significantly influence diagnostic performance. In conclusion, FDG-PET/CT can be a useful method for unknown primary tumor detection. Future studies are required to prove the assumed advantage of FDG-PET/CT over FDG-PET alone and to further explore causes of heterogeneity.

Keywords: FDG-PET/CT, Cancer of unknown primary, Primary tumor detection, Systematic review, Meta-analysis

Introduction

Cancer of unknown primary (CUP), defined as the presence of histologically proven metastatic disease for which the site of origin cannot be identified at the time of diagnosis (despite comprehensive diagnostic workup), is one of the ten most frequent cancers (accounting for 3–5% of all malignancies) and is the fourth most common cause of cancer-related death [1, 2]. Failure to detect the primary tumor impedes optimization of treatment planning, which, in turn, may negatively influence patient prognosis. 18F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) allows whole-body tumor detection [3] and has proven to be useful in patients with CUP for the detection of the primary tumor [46]. A disadvantage of FDG-PET, however, is its lack of anatomic information, which may impede precise localization of FDG accumulation. Furthermore, tumors with low or even no FDG uptake may be missed by FDG-PET. Complimentary anatomic information, provided by computed tomography (CT) or magnetic resonance (MR) imaging, may improve the diagnostic performance of FDG-PET alone. The relatively recently introduced combined FDG-PET/CT scanner allows obtaining both functional and anatomic images in a single examination [7, 8] and may be of great value for the detection of primary tumors in patients with CUP. The purpose of this study was therefore to systematically review and meta-analyze published data on the diagnostic performance of FDG-PET/CT in unknown primary tumor detection.

Methods

Search strategy

A computer-aided search of the PubMed/MEDLINE and Embase databases was conducted to find relevant published articles on the diagnostic performance of combined FDG-PET/CT in primary tumor detection in patients with CUP. The search strategy is presented in Table 1. No beginning date limit was used. The search was updated until 13 March 2008. Only English-, German-, French-, Italian- or Spanish-language studies were considered because the investigators were familiar with these languages. To expand our search, bibliographies of articles that finally remained after the selection process were screened for potentially suitable references.

Table 1.

Search strategy and results as on 13 March 2008

# Search string PubMed/MEDLINE Embase
1 Fluorodeoxyglucose OR 2-fluoro-2-deoxy-D-glucose OR FDG OR positron emission tomography OR positron-emission tomography OR PET 39,616 46,549
2 Computed tomography OR computerized tomography OR computed tomographic OR CT OR CAT 430,940 317,859
3 Unknown primary OR unidentified primary OR occult primary OR unknown origin OR unidentified origin 32,203 25,105
4 #1 AND #2 AND #3 230 185

Study selection

Studies or subsets in studies investigating the diagnostic performance of FDG-PET/CT in primary tumor detection in patients with CUP were eligible for inclusion. Review articles, meta-analyses, abstracts, editorials or letters, case reports, guidelines for management and studies examining ten or fewer patients with CUP were excluded. Studies or subsets in studies were excluded if metastases were not histologically confirmed. Studies that provided insufficient data to construct a 2 × 2 contingency table to calculate sensitivity and specificity for primary tumor detection in patients with CUP were also excluded. When data were presented in more than one article, the article with the largest number of patients or the article with the most details was chosen.

Two researchers (T.C.K., R.M.K.) independently reviewed the titles and abstracts of the retrieved articles, applying the inclusion and exclusion criteria mentioned above. Articles were rejected if they were clearly ineligible. The same two researchers then independently reviewed the full-text version of the remaining articles to determine their eligibility for inclusion. Disagreements were resolved in a consensus meeting.

Data abstraction

For each included study, information was collected concerning basic study and patient characteristics (author names, year of publication, country of origin, study design, number, age and sex ratio of investigated patients, location of metastases of unknown primary, histology of metastases of unknown primary and diagnostic workup before FDG-PET/CT), FDG-PET/CT parameters (time of fasting before FDG administration, FDG dose, time interval between FDG administration and data acquisition, number of CT detector rows, reconstructed CT slice width, administration of intravenous and/or oral CT contrast agents and area of body examined) and FDG-PET/CT evaluation (evaluation of attenuation-corrected and/or non-attenuation corrected images, interpreters(s) of FDG-PET/CT, criteria for positivity and applied reference standard).

To calculate estimates of diagnostic performance (i.e., primary tumor detection rate, sensitivity and specificity), a true-positive result was considered when FDG-PET/CT suggested the location of the primary tumor and was subsequently confirmed. A false-positive result was considered when this location was not confirmed. The sites suggested by FDG-PET/CT were confirmed by histopathological analysis of tissue obtained by biopsy or surgery, considered as the reference standard. However, imaging procedures or clinical follow-up was accepted if no histopathological proof could be obtained. A true-negative result was considered when neither FDG-PET/CT nor the reference standard could detect the primary tumor. A false-negative result was considered if the primary tumor was detected in a particular location that was negative on FDG-PET/CT [4, 6].

Study quality

For each included study, the methodological quality was assessed by using the Quality Assessment of Studies of Diagnostic Accuracy Included in Systematic Reviews (QUADAS) criteria, which is a 14-item instrument [9, 10]. The item “Is the time period between reference standard and index test short enough to be reasonably sure that the target condition did not change between the two tests?” was removed from the standard QUADAS list, since follow-up is required to verify negative FDG-PET/CT findings. The item “Did patients receive the same reference standard regardless of the index test result?” was removed from the standard QUADAS list, since positive FDG-PET/CT findings can be confirmed by means of histology, but negative FDG-PET/CT findings require follow-up. The item “Were the reference standard results interpreted without knowledge of the results of the index test?” was also removed from the standard QUADAS list, since positive FDG-PET/CT findings can be verified by means of histopathological analysis of tissue obtained by biopsy or surgery. One item was added to the standard QUADAS list: “Was comparator review bias avoided?” The complete list of quality items is displayed in Table 2. For each item, the two researchers (TCK, RMK) independently assessed whether it was fulfilled (yes or no). If it was unclear from the information provided in an article as to whether an item was fulfilled, the item was rated as “unclear.” Both “no” and “unclear” responses were interpreted as indicating that the quality criterion was not met. Disagreements were discussed and resolved by consensus. The total quality score was expressed as a percentage of the maximum score of 12.

Table 2.

Criteria list used to assess the methodological quality of the studies

Quality item Positive score
Was the spectrum of patients representative of the patients who will receive the test in practice? Patients with histologically confirmed metastatic cancer, in whom medical history, physical examination, full blood count, basic biochemistry battery, urinalysis, stool occult blood testing, immunohistochemistry with specific markers as well as imaging technology with chest X-ray, computed tomography of the chest abdomen and pelvis or mammography and MR imaging in certain cases failed to detect the primary tumor, were included
Were selection criteria clearly described? It was clear how patients were selected for inclusion
Is the reference standard likely to correctly classify the target condition? Histopathological analysis of tissue obtained by biopsy or surgery, or imaging procedures or clinical follow-up if no histopathological proof could be obtained
Did the whole sample, or a random selection of the sample, receive verification using a reference standard of diagnosis? All patients, or a random sample of patients who underwent FDG-PET/CT, also underwent the reference standard
Was the reference standard independent of the index test (i.e., the index test did not form part of the reference standard)? FDG-PET/CT did not form part of the reference standard
Was the execution of the index test described in sufficient detail to permit replication of the test? All of the following parameters were described:
-Time of fasting before FDG administration, FDG dose, time interval between FDG administration and scanning
-Application of intravenous and/or oral CT contrast
-Scanned area
-Evaluated images (AC and/or nAC)
-Interpreter(s) of FDG-PET/CT mentioned
Was the execution of the reference standard described in sufficient detail to permit replication? Besides histopathological analysis of FDG-PET/CT positive findings, additional diagnostic procedures (e.g., gastroscopy, CT, MR imaging) and duration of follow-up were described, if applicable
Were the index test results interpreted without knowledge of the results of the reference standard? FDG-PET/CT was interpreted without knowledge of the findings of the reference standard
Were the same clinical data available when test results were interpreted as would be available when the test is used in practice? Interpreter(s) of FDG-PET/CT was/were aware of the histologic nature of the metastases of unknown primary
Were uninterpretable/intermediate test results reported? All FDG-PET/CT results, including uninterpretable/ indeterminate/intermediate were reported
Were withdrawals from the study explained? It is clear what happened to all patients who entered the study
Was comparator review bias avoided? Blinding FDG-PET/CT to the other imaging modality, if more than one imaging modality was applied

AC: attenuation-corrected images

nAC: non-attenuation-corrected images

CT: computed tomography

FDG-PET: 18F-fluoro-2-deoxyglucose

FDG-PET/CT: 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography

MR: magnetic resonance

Statistical analysis

Primary tumor detection rates of individual studies were calculated and totaled. Locations of primary tumors detected by FDG-PET/CT, locations of false-positives FDG-PET/CT findings and locations of false-negative FDG-PET/CT findings were recorded and summarized. Sensitivities and specificities of FDG-PET/CT in primary tumor detection (with corresponding 95% CIs) were calculated from the original numbers given in the included studies and meta-analyzed using a random effects model. Where sensitivity or specificity estimates for an individual study were zero, a continuity correction of 0.5 was added to every value for that study in order to make the calculation of sensitivity and specificity defined.

A chi-squared test was performed to test for heterogeneity between studies. Heterogeneity was defined as P < 0.10. Differences in sensitivities and specificities due to different cut-offs (thresholds) used in different studies to define a positive (or negative) FDG-PET/CT results were assessed by computing the Spearman correlation coefficient between the logit of sensitivity and logit of 1-specificity. A strong positive correlation would suggest the presence of a threshold effect. Other potential sources for heterogeneity were explored by assessing whether certain predefined covariates significantly influenced (i.e., P < 0.05) the relative diagnostic odds ratio (RDOR) [11]. Although the findings of such analyses should be regarded mainly as hypothesis generating, statistical significance may suggest substantial changes in the diagnostic performance of the test under study as the covariate changes. Specifically, analyses were performed according to completeness of diagnostic workup before FDG-PET/CT (studies that fulfilled quality item 1 vs. studies that did not fulfill quality item 1 [Table 2]), location of metastases of unknown primary (cervical vs. extracervical), administration of CT contrast agents (both intravenous and oral contrast vs. no intravenous or oral contrast agent, or not reported), type of FDG-PET/CT images evaluated (both attenuation-corrected and non-attenuation-corrected images vs. attenuation-corrected images only, or not reported) and way of FDG-PET/CT review (reported blinding to reference test vs. no or unreported blinding to reference test.

Statistical analyses were executed using the Statistical Package for the Social Sciences version 14.0 software (SPSS Inc., Chicago, IL) and Meta-DiSc statistical software version 1.4 (Unit of Clinical Biostatistics, Ramón y Cajal Hospital, Madrid, Spain) [11].

Results

Literature search

The computer-aided search revealed 230 articles from PubMed/MEDLINE and 185 articles from Embase (Table 1). Reviewing titles and abstracts from PubMed/MEDLINE revealed 17 articles potentially eligible for inclusion. Reviewing titles and abstracts from Embase revealed 17 articles potentially eligible for inclusion, of which 15 were all already identified by the PubMed/MEDLINE search. Thus, 19 studies [1230] remained for possible inclusion and were retrieved in full text version. Screening of the references of these 19 articles did not bring up new articles. After reviewing the full article, two articles [17, 19] were excluded because a part of the study population underwent FDG-PET alone and was not separately analyzed from patients undergoing FDG-PET/CT, two articles [25, 30] were excluded because sensitivity and specificity for primary tumor detection could not be calculated, one article [28] was excluded because it did not separately analyze patients with CUP, one article [21] was excluded because fewer than ten patients with CUP were included, one article [23] was excluded because it was an editorial, and one article [24] was excluded because the same data were used in a later study. Eventually, 11 studies [1216, 18, 20, 22, 26, 27, 29], comprising a total sample size of 433 patients with CUP, met all inclusion and exclusion criteria, and they were included in this systematic review. The characteristics of the included studies are presented in Tables 3, 4, 5 and 6.

Table 3.

Basic study and patient characteristics (1)

Study and year Country of origin Study design No. of patients Age in years (mean, range) Sex (M/F)
Fencl et al. [12], 2007 Czech Republic Retrospective 82 NR NR
Nassenstein et al. [13], 2007 Germany NR 39 60, 39–89 31/8
Fleming et al. [14], 2007 USA Retrospective 22 NR NR
Bruna et al. [15], 2007 France Retrospective 37 59, 31–85 14/23
Wartski et al. [16], 2007 France Retrospective 38 57, 36–80 31/7
Ambrosini et al. [18], 2006 Italy NR 38 59, 41–77 22/16
Fakhry et al. [20] 2006 France Retrospective 22 48, 43–71 17/5
Pelosi et al. [22], 2006 Italy Retrospective 68 63, 42–79 36/32
Nanni et al. [26], 2005 Italy NR 21 60, 41–87 12/9
Freudenberg et al. [27], 2005 Germany Retrospective 21 64, 46–94 16/5
Gutzeit et al. [29], 2005 Germany Retrospective 45 57, 29–95 26/19

NR: not reported

Table 4.

Basic study and patient characteristics (2)

Study and year Location of metastases of unknown primary (N) Histology of metastases of unknown primary (N) Diagnostic workup before FDG-PET/CT
Fencl et al. [12], 2007 -Cervical (20) -Anaplastic carcinoma (35) In all patients detailed medical history, full physical and laboratory examinations and diagnostic imaging methods
-Extracervical (61) -Adenocarcinoma (24)
-Squamous-cell carcinoma (5)
-Spinocellular carcinoma (7)
-Mucinous carcinoma (10)
-Small-cell carcinoma (1)
Nassenstein et al. [13], 2007 Cervical (39) -Squamous-cell carcinoma (27) In all patients tumor workup including physical examination, ultrasound, chest X-ray as well as complete endoscopic exploration with multiple blind biopsies of the nasopharynx, tonsils and tongue base
-Adenocarcinoma (5)
-Undifferentiated carcinoma (2)
-Lymphoepithelioid cancer (1)
-Malignant melanoma (1)
-Neuroendocrine cancer (1)
-Papillary carcinoma (1)
-Undifferentiated carcinoma (1)
Fleming et al. [14], 2007 Cervical and extracervical (22) NR NR
Bruna et al. [15], 2007 Cervical and extracervical (37) -Adenocarcinoma (17) In all but three patients, CT of the neck and thorax; the three patients without a CT of the neck and thorax had at least a chest X-ray. In all patients CT and/or ultrasound of the abdomen and pelvis. In 13/23 females mammography and ultrasound of the breasts, in five females an additional MR of the breasts. In 25 patients, invasive diagnostic tests (endoscopic or surgical), of which 16 were bronchoscopies, 10 upper airway endoscopies, 9 colonoscopies and 8 gastroscopies
-Squamous-cell carcinoma (14)
- Undifferentiated carcinoma (6)
Wartski et al. [16], 2007 Cervical (38) -Squamous-cell carcinoma (32) In all patients systematic palpation, fiber-optic laryngoscopy and nasopharyngoscopy, CT and/or MR imaging with sections from the skull base to the mediastinum and rigid panendoscopy with randomized biopsies at the most frequent sites of primary tumor
-Undifferentiated carcinoma (4)
-Mucoepidermoid carcinoma (2)
Ambrosini et al. [18], 2006 NR -Adenocarcinoma (13) In all patients physical examination and negative laboratory and imaging tests; all patients underwent multislice CT and MR imaging
-Epithelial carcinoma (8)
-Squamous-cell carcinoma (5)
-Mucoid adenocarcinoma (2)
-Poorly differentiated carcinoma (2)
-Undifferentiated adenocarcinoma (2)
-Flat-cell tumor (1)
-Germ-cell tumor (1)
-Melanoma (1)
-Spindle-cell tumor (1)
-Spinous-cell carcinoma (1)
-Transitional-cell carcinoma (1)
Fakhry et al. [20] 2006 -Cervical (22) -Squamous-cell carcinoma (22) In all patients CT and nasofibroscopy
Pelosi et al. [22], 2006 -Cervical (18) -Undefined carcinoma (32) In all patients physical examination, laboratory tests and conventional diagnostic procedures, i.e., chest X-ray, abdominal contrast enhancement CT and, on the basis of suspected primary disease, chest contrast enhancement CT, MR imaging, ultrasonography, mammography and endoscopic procedures
-Extracervical (50) -Adenocarcinoma (18)
-Squamous-cell carcinoma (8)
-Poorly differentiated carcinoma (5)
-Melanoma (4)
-Urothelial-cell carcinoma (1)
Nanni et al. [26], 2005 -Cervical (3) -Adenocarcinoma (8) In all patients physical examination (digital rectal examination with tests for occult blood in the stool, breast palpation and pelvic examination in women, prostate and testicular examination in men) and traditional diagnostic procedures according to international guidelines (complete blood counts, liver and renal function tests, urine analysis, chest radiography, CT and/or MRI of the abdomen and pelvis plus X-ray mammography in women and prostate-specific antigen test in men)
-Extracervical (17) -Squamous-cell carcinoma (7)
-Cervical and extracervical (1) -Poorly differentiated carcinoma (1)
-Melanoma (1)
-Transitional-cell carcinoma (1)
-Germ-cell tumor (1)
-Spindle-cell carcinoma (1)
-Flat-cell tumor (1)
Freudenberg et al. [27], 2005 Cervical (21) -Squamous-cell carcinoma (14) In all patients clinical, endoscopic, sonographic and planar radiological staging (none of the patients had received a dedicated head and neck CT before)
-Adenocarcinoma (4)
-Undifferentiated malignancy (3)
Gutzeit et al. [29], 2005 -Cervical (18) -Adenocarcinoma (25) In all patients a complete medical history, thorough physical examination and conventional diagnostic strategies (including comprehensive laboratory analysis, projectional and cross-sectional imaging and endoscopic procedures where indicated)
-Extracervical (27) -Squamous-cell carcinoma (15)
-Undifferentiated carcinoma (5)

CT: computer tomography

FDG-PET/CT: 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography

MR: magnetic resonance

NR: not reported

Table 5.

FDG-PET/CT parameters

Study and year Time of fasting before FDG administration (h) FDG dose (MBq) Time interval between FDG administration and data acquisition (min) No. of CT detector rows Reconstructed slice width (mm) Intravenous CT contrast Oral CT contrast Area of body scanned
Fencl et al. [12], 2007 ≥6 350–450 60–90 2 4.0 Yes and no Yes From the skull base to below the groin
Nassenstein et al. [13], 2007 ≥4 350 60 2 -3.0 (head and neck) Yes Yes From the head to the upper thigh
-5.0 (chest and abdomen)
Fleming et al. [14], 2007 NR 555 75 16 NR NR NR From the top of the head to midthigh
Bruna et al. [15], 2007 ≥6 5.5/kg (max. 550) 60 NR NR NR NR From the top of the head to midthigh
Wartski et al. [16], 2007 ≥6 4–5/kg 60 NR 5.0 No No From the skull to the midthigh
Ambrosini et al. [18], 2006 6 370 60–90 NR NR NR NR “Whole-body”
Fakhry et al. [20] 2006 ≥6 260–330 60 NR NR NR NR From the skull base to the thighs
Pelosi et al. [22], 2006 ≥6 222–370 60 NR NR NR NR From neck to pelvis or from skull to feet
Nanni et al. [26], 2005 ≥6 370 60–90 NR NR NR NR “Total body scan”
Freudenberg et al. [27], 2005 ≥10 360 60 2 -3.0 (head and neck) -No (head and neck -No (head and neck) Head, neck, thorax, abdomen and pelvis
-5.0 (from thorax to pelvis) -Yes (thorax to pelvis) -Yes (thorax to pelvis)
Gutzeit et al. [29], 2005 ≥4 350 60 2 5.0 Yes Yes Head, neck, thorax, abdomen and pelvis

CT: computed tomography

FDG: 18F-fluoro-2-deoxyglucose

NR: not reported

Table 6.

FDG-PET/CT evaluation

Study and year Evaluated images Interpreter(s) of FDG-PET/CT Criteria for positivity Reference standard
Fencl et al. [12], 2007 AC and nAC Seven physicians experienced in both PET and CT reading were randomly involved in routine evaluation of findings; in the event of any uncertainty, a second or even a third opinion was solicited FDG hypermetabolism at the site of pathological changes on CT or marked focal hypermetabolism at sites suggestive of malignancy (liver parenchyma, bone marrow) despite absence of signs of pathology at those sites on CT A diagnosis of the primary site of a malignancy was classified as true positive only when it was confirmed histologically. If the finding was not confirmed histologically, the diagnosis was classified as false positive. An evaluation was classified as true negative if neither FDG-PET/CT nor histological findings or clinical follow-up (including subsequent imaging tests) determined the site of the primary. When the site of the primary was not identified, but was proven histologically, the finding was classified as false negative
Nassenstein et al. [13], 2007 NR Two different reading teams, each consisting of a radiologist and a nuclear medicine physician Contrast-enhancing mass on CT or focally increased FDG uptake on PET “Full medical history was available for all patients”
Fleming et al. [14], 2007 NR One of three neuroradiologists An SUV level greater than 2.5 was considered consistent with abnormal, hypermetabolic activity in primary, regional and distant disease Each site of increased PET metabolic activity was compared with operative histopathology records
Bruna et al. [15], 2007 NR NR NR -“Follow-up”
-Histology (n = 7)
-Complimentary examination (n = 3), among which were CT of the abdomen and pelvis (n = 2)
Wartski et al. [16], 2007 AC and nAC Two experienced nuclear medicine physicians, independently Increased FDG focal uptake indicative of a primary tumor in the head and neck and/or chest regions FDG-PET/CT results were correlated to the patient’s medical record concerning pathological results and treatment. A FDG-PET/CT result was considered as a true positive when an FDG focus matched the primary tumor found during the second panendoscopy, a false positive when the increased FDG focal uptake did not match panendoscopy results and a false negative when the second panendoscopy detected malignant lesions with no corresponding increased FDG focal uptake
Ambrosini et al. [18], 2006 NR Three nuclear medicine physicians in consensus NR -PET/CT findings were subsequently confirmed by surgery or biopsy of the primary tumor
-Gastroscopy and 3-month follow-up in one patient
Fakhry et al. [20] 2006 NR Two nuclear medicine physicians NR (visual interpretation) Histology and/or clinical follow-up >6 months in all patients
Pelosi et al. [22], 2006 NR Two nuclear medicine physicians in consensus NR The FDG pathological findings, suspected for primaries, were further investigated with other imaging examination, biopsy and/or surgery and clinical follow-up (minimum follow-up of 3 months after the FDG-PET/CT study)
Nanni et al. [26], 2005 NR Three skilled nuclear medicine physicians; in case of discrepancy, the FDG-PET/CT interpretation was reached by consensus NR -FDG-PET/CT findings were subsequently confirmed by surgery or biopsy of the primary tumor
-Gastroscopy in one patient
Freudenberg et al. [27], 2005 NR Two experienced nuclear medicine physicians in consensus (FDG-PET) and two radiologists (CT) -FDG-PET: regions of focally increased tracer uptake (a maximum SUV of >2.5 was considered to represent malignancy in otherwise equivocal findings) Histopathology (n = 14) and clinical follow-up ≥9 months (n = 7) with subsequent panendoscopy with biopsy of the most probable tumor sites (n = 7), ultrasound (n = 7), CT (n = 6), MRI (n = 6), diagnostic tonsillectomy (n = 4) and additional biopsies (n = 4)
-CT: contrast-enhancing masses or asymmetries typical of malignancies
Gutzeit et al. [29], 2005 AC and nAC A nuclear medicine physician and a radiologist, both with 2 years of PET/CT experience Contrast material-enhanced mass on CT or focally increased glucose metabolism with a SUV exceeding 2.5 on FDG-PET -All potential sites of the primary tumor depicted by FDG-PET/CT were histologically verified
-Axillary lymph node dissection in one FDG-PET/CT-negative patient
-Endoscopy and biopsy of the esophagus in one FDG-PET/CT-negative patient

AC: attenuation-corrected images

nAC: non-attenuation-corrected images

CT: computed tomography

FDG-PET: 18F-fluoro-2-deoxyglucose positron emission tomography

FDG-PET/CT: 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography

PET: positron emission tomography

PET/CT: positron emission tomography/computed tomography

NR: not reported

SUV: standardized uptake value

Methodological quality assessment

Twelve methodological quality items were assessed for each of the 11 included studies (Table 7). The total methodological quality score, expressed as a fraction of the maximum score, ranged from 42% to 75% (median, 50%).

Table 7.

Quality assessment of the 11 included studies

Study and year Quality items % of maximum score
1 2 3 4 5 6 7 8 9 10 11 12
Fencl et al. [12], 2007 - + + + + + - - - + + + 67
Nassenstein et al. [13], 2007 - - - + - + - - - + + + 42
Fleming et al. [14], 2007 - + - - + - - - - + + + 42
Bruna et al. [15], 2007 - + + + - - - - - + + + 50
Wartski et al. [16], 2007 - - - + + + + + - + + + 67
Ambrosini et al. [18], 2006 - - - - - - + - + + + + 42
Fakhry et al. [20] 2006 - + + + - - - - - + + + 50
Pelosi et al. [22], 2006 + - + + - - - - - + + + 50
Nanni et al. [26], 2005 + - + - + - + + + + + + 75
Freudenberg et al. [27], 2005 - - + + + + + - - + + + 67
Gutzeit et al. [29], 2005 - - - - + + + + - + + + 58

Diagnostic performance

The results of the 11 included studies are presented in Tables 8 and 9, and Figs. 1, 2 and 3. Primary tumor detection rates ranged from 22 to 73%, with an overall detection rate of 37% (162/433) (Table 8). The most commonly detected location of the primary tumor by FDG-PET/CT was the lung, 33% (Fig. 1). The most common locations of false-positive FDG-PET/CT findings were the lung and the oropharynx, both 15% (Fig. 2). The most common cause of false-negative FDG-PET/CT findings was breast cancer, 27% (Fig. 3). Sensitivity and specificity of FDG-PET/CT in primary tumor detection ranged from 55% to 100% and from 73% to 100%, with pooled estimates of 84% (95% CI 78–88%) and 84% (95% CI 78–89%), respectively (Table 8). The included studies were statistically heterogeneous in their estimates of sensitivity (P = 0.0001), but homogeneous in their estimates of specificity (P = 0.2114).

Table 8.

Diagnostic performance of FDG-PET/CT in primary tumor detection

Study and year Primary tumor detection rate (%) Sensitivity (%) Specificity (%)
Value 95% CI Value 95% CI
Fencl et al. [12], 2007 22 55 38–70 75 62–85
Nassenstein et al. [13], 2007 28 100 74–100 85 69–94
Fleming et al. [14], 2007 73 94 73–99 100 61–100
Bruna et al. [15], 2007 38 93 70–99 77 57–90
Wartski et al. [16], 2007 34 93 69–99 73 48–89
Ambrosini et al. [18], 2006 53 100 84–100 95 76–99
Fakhry et al. [20] 2006 32 70 40–89 75 47–91
Pelosi et al. [22], 2006 35 83 66–93 87 73–94
Nanni et al. [26], 2005 57 100 76–100 89 57–98
Freudenberg et al. [27], 2005 57 86 60–96 100 65–100
Gutzeit et al. [29], 2005 33 88 66–97 89 73–96
Pooled estimate 37 84 78–88 84 78–89

Table 9.

Results of subgroup analysis

Parameter Value No. of studies Relative diagnostic odds ratio (1 vs. 2)
Value 95% CI P-value
Completeness of diagnostic workup before FDG-PET/CT 1. Complete 2 1.93 0.22–17.28 0.5072
2. Incomplete 9
Location of metastases 1. Cervical 6 0.38 0.02–9.55 0.4765
2. Extracervical 2
Administration of CT contrast agents 1. Intravenous and oral 3 2.42 0.32–18.15 0.3347
2. Not reported 7
Evaluated FDG-PET/CT images 1. AC and nAC 3 0.36 0.06–2.09 0.2187
2. AC only or NR 8
Way of FDG-PET/CT review 1. Reported blinding 3 1.18 0.10–13.54 0.8766
2. No reported blinding 8

AC: attenuation-corrected images

nAC: non-attenuation-corrected images

NR: not reported

Fig. 1.

Fig. 1

Locations of primary tumours detected by FDG-PET/CT

Fig. 2.

Fig. 2

Locations of false-positive FDG-PET/CT findings

Fig. 3.

Fig. 3

Locations of false-negative FDG-PET/CT findings

A Spearman correlation coefficient of -0.201 (P = 0.554) between the logit of sensitivity and logit of 1-specificity did not suggest the presence of a threshold effect. No significantly increased RDORs were observed in any of the subgroup analyses according to completeness of diagnostic workup before FDG-PET/CT, location of metastases of unknown primary, administration of CT contrast agents, type of FDG-PET/CT images evaluated and way of FDG-PET/CT review (Table 9).

Discussion

CUP represents a heterogeneous group of metastatic tumors for which no primary site can be detected following a thorough medical history, careful clinical examination and extensive diagnostic workup [1, 2]. Attempts to identify the primary tumor in patients with CUP are are often time consuming, expensive and ultimately unsuccessful [1, 2]. The results of this study indicate that, overall, FDG-PET/CT is able to detect 37% of primary tumors in patients with CUP, and sensitivity and specificity are reasonably high (both 84%). Sensitivity, however, was heterogeneous across studies. Subgroup analysis could not clarify the observed heterogeneity. It should be noted, however, that results from our subgroup analysis may not be conclusive because of the relatively small number of included studies. Furthermore, it was not possible to perform subgroup analysis according to the number of CT detector rows and CT slice width due to incomplete reporting of included studies. Future studies are required to further investigate potential sources of heterogeneity.

The results of this systematic review should be interpreted carefully, since the methodological quality of the included studies was moderate. Several methodological shortcomings were identified, of which spectrum bias, bias due to the use of an inadequate reference standard and verification bias may seriously have affected the results. According to Pavlidis et al. [1, 2], the precise clinical definition of CUP should refer to patients who present with histologically confirmed metastatic cancer in whom medical history, physical examination, full blood count, basic biochemistry battery, urinalysis, stool occult blood testing, immunohistochemistry with specific markers as well as imaging technology with chest X-ray, CT of the chest abdomen and pelvis or mammography and MR imaging in certain cases have failed to detect the primary tumor. However, only two studies [22, 26] (18%) included patients who fulfilled these criteria. In the other nine studies [1216, 18, 20, 27, 29], diagnostic performance of FDG-PET/CT might have been overestimated because of (possible) incomplete diagnostic workup. Furthermore, only five studies [12, 15, 20, 22, 27] applied an adequate reference standard of histology and follow-up in all patients. Consequently, in the other six studies [13, 14, 16, 18, 26, 29], diagnostic performance of FDG-PET/CT might have been overestimated. Other methodological flaws include an inadequate description of selection criteria in seven studies [13, 16, 18, 22, 26, 27, 29] (64%), the possibility that FDG-PET/CT formed part of the reference standard (incorporation bias) in five studies [13, 15, 18, 20, 22] (46%), inadequate description of the execution of FDG-PET/CT in six studies [14, 15, 18, 20, 22, 26] (55%), inadequate description of the reference standard in six studies [1215, 20, 22] (55%), possible interpretation of FDG-PET/CT while knowing the results of the reference standard (test review bias) in eight studies [1215, 18, 20, 22, 27] (73%) and possible interpretation of FDG-PET/CT without knowledge of the histological nature of the metastases of unknown primary in nine studies [1215, 16, 20, 22, 27, 29] (82%).

Lung, oropharyngeal and pancreatic carcinoma were the most frequently detected primary tumors by FDG-PET/CT in this meta-analysis (33%, 16% and 5%, respectively). This is partly in line with previous autopsy studies in patients with CUP [3134], which have shown that the most common locations of the primary tumor are the lung and the pancreas. The high detection rate of oropharyngeal carcinoma by FDG-PET/CT in this meta-analysis, however, is discrepant with the results of autopsy studies [3134]. This finding can by explained by the fact that 4 of 11 included studies [13, 16, 20, 27] exclusively investigated patients with cervical metastases of unknown primary, whose primary tumors are most frequently located in the oropharynx [5, 35]. Indeed, these four studies [13, 16, 20, 27] comprised 69% of all oropharyngeal carcinomas detected by FDG-PET/CT in this meta-analysis. The most commonly reported locations of false-positive FDG-PET/CT results were the lung and the oropharynx (both 15%). Causes of false-positive results may be FDG uptake in benign conditions with increased glycolysis (e.g., one false-positive FDG-PET/CT finding in the lung proved to be a pulmonary infarction [29]), high physiological FDG uptake (e.g., muscle FDG uptake) and failure to evaluate both attenuation-corrected and non-attentuation-corrected images to minimize the chance of misinterpreting (FDG-PET/CT) artifacts as pathologic (only three of the included studies [12, 16, 29] explicitly stated that both attenuation-corrected and non-attentuation-corrected images were evaluated) [3638]. Breast cancer was the most common cause of false-negative FDG-PET/CT results (27%). This may be explained by the fact that small (<1 cm) and slow-growing, low-grade (breast) cancers with low or no FDG uptake (e.g., tubular carcinoma and noninvasive cancers such as ductal or lobular carcinoma in situ) may be overlooked on FDG-PET/CT [39].

FDG-PET alone has been thoroughly investigated for primary tumor detection in patients with CUP; meta-analyses on FDG-PET reported primary tumor detection rates ranging between 24.5% and 43%, sensitivities ranging between 87% and 91.9%, and specificities ranging between 71% and 81.9% [46]. An advantage of FDG-PET/CT over FDG-PET alone is more accurate localization of foci with increased FDG uptake, and this may reduce the problems of physiological FDG uptake being misinterpreted as pathological and false localization of disease. In addition, tumors with low or no FDG uptake, or tumors of a size below the spatial resolution of FDG-PET, may be depicted by the CT component of FDG-PET/CT. Recently introduced combined FDG-PET/CT scanners with a 64-section multidetector CT component and less than 2.5-mm collimation may detect small primary cancers in the lungs or oropharynx earlier [40] and are clearly superior to FDG-PET/CT alone. Furthermore, the additional anatomic data obtained using FDG-PET/CT may increase the accuracy of FDG-PET-directed biopsies. Another advantage of FDG-PET/CT is the use of the CT images for attenuation correction of the PET emission data, which reduces whole-body scanning times from 45 min to 30 min or less. This approach also provides low-noise attenuation correction factors, compared with those from standard PET transmission measurements using an external radiation source, and eliminates bias from emission contamination of postinjection transmission scans [7, 8]. On the other hand, a disadvantage of CT-based attenuation correction may be misclassification of regions containing high concentrations of CT contrast medium with high-density bone (CT contrast agents have high atomic numbers relative to the atomic number of bone, and as the concentration of a contrast agent increases, its corresponding CT number will fall within the CT number range for bone), which results in overcorrection for photon attenuation, consequently leading to an overestimation of FDG uptake in the contrast-enhanced region [41, 42]. Three of the included studies [13, 27, 29] directly compared FDG-PET/CT and (CT-based attenuation-corrected) FDG-PET alone. In all three studies [13, 27, 29], FDG-PET/CT was able to detect a few more primary tumors than FDG-PET alone, but these differences were not statistically significant. Therefore, FDG-PET/CT has not yet been proven to be diagnostically superior to FDG-PET alone. More studies directly comparing FDG-PET/CT and FDG-PET alone are required to prove the assumed advantage of FDG-PET/CT over FDG-PET alone.

Whole-body MR imaging may be an alternative to FDG-PET/CT [43]; it does not require the operator to work with a potentially harmful radiotracer, the safety profile of MR contrast agents is favorable compared with that of iodinated contrast with CT [44], and the costs for a whole-body MR imaging examination (about 575 euros) are approximately two times less than that of a whole-body FDG-PET/CT examination (about 1,123 euros) [45]. In 1998, Eustace et al. [46] showed the potential of whole-body MR imaging in primary tumor detection in four patients with CUP, using a short-tau-inversion-recovery sequence. However, to our knowledge, no other reports on the diagnostic performance of whole-body MR imaging in unknown primary tumor detection have been published since then, while (both anatomical and functional whole-body) MR technology has continued to evolve [47, 48].

Identification of the primary tumor in patients with CUP enables accurate tumor staging, which allows optimizing treatment planning; this, in turn, may improve patient prognosis. On the other hand, it should be realized that FDG-PET/CT is an expensive examination, and false-positive FDG-PET/CT findings may result in unnecessary additional invasive diagnostic procedures, which have associated morbidities and costs [49]. In general, it appears that patients with CUP have a limited life expectancy, with a median survival of approximately 6–9 months [1, 2], but a median survival of 23 months has been reported for patients with CUP and an identified primary tumor subsequently treated with specific therapy [50]. Similarly, one study [51] reported that the 3-year survival rate for patients with cervical metastases and occult oropharyngeal primary tumors was 100% after treatment, while the patients with cervical metastases in which a primary tumor was not detected showed a survival rate of 58%. Only four studies included in this systematic review reported the therapeutic impact of FDG-PET/CT; in these four studies, FDG-PET/CT modified therapy in 18.2–60% of patients [15, 16, 20, 22]. Although one study [12] reported that the survival rate of CUP patients with at least one hypermetabolic lesion was significantly lower (P < 0.0279) than that of the remaining CUP patients, none of the included studies reported FDG-PET/CT-modified patient outcomes. Therefore, the additional value of FDG-PET/CT to patients with CUP and its cost-effectiveness should be further investigated; the currently presented data can be used to perform such an analysis.

In conclusion, although included studies were of moderate methodological quality and their results were heterogeneous, the results of this systematic review and meta-analysis indicate that FDG-PET/CT can be a useful method for unknown primary tumor detection. Future studies are required to prove the assumed advantage of FDG-PET/CT over FDG-PET alone and to further explore causes of heterogeneity.

Acknowledgments

Open Access

This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

References

  • 1.Pavlidis N. Forty years experience of treating cancer of unknown primary. Acta Oncol. 2007;46:592–601. doi: 10.1080/02841860701243095. [DOI] [PubMed] [Google Scholar]
  • 2.Pavlidis N, Briasoulis E, Hainsworth J, Greco FA. Diagnostic and therapeutic management of cancer of an unknown primary. Eur J Cancer. 2003;39:1990–2005. doi: 10.1016/S0959-8049(03)00547-1. [DOI] [PubMed] [Google Scholar]
  • 3.Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology. 2004;231:305–332. doi: 10.1148/radiol.2312021185. [DOI] [PubMed] [Google Scholar]
  • 4.Sève P, Billotey C, Broussolle C, Dumontet C, Mackey JR. The role of 2-deoxy-2-[F-18]fluoro-D-glucose positron emission tomography in disseminated carcinoma of unknown primary site. Cancer. 2007;109:292–299. doi: 10.1002/cncr.22410. [DOI] [PubMed] [Google Scholar]
  • 5.Rusthoven KE, Koshy M, Paulino AC. The role of fluorodeoxyglucose positron emission tomography in cervical lymph node metastases from an unknown primary tumor. Cancer. 2004;101:2641–2649. doi: 10.1002/cncr.20687. [DOI] [PubMed] [Google Scholar]
  • 6.Delgado-Bolton RC, Fernández-Pérez C, González-Maté A, Carreras JL. Meta-analysis of the performance of 18F-FDG PET in primary tumor detection in unknown primary tumors. J Nucl Med. 2003;44:1301–1314. [PubMed] [Google Scholar]
  • 7.Blodgett TM, Meltzer CC, Townsend DW. PET/CT: form and function. Radiology. 2007;242:360–385. doi: 10.1148/radiol.2422051113. [DOI] [PubMed] [Google Scholar]
  • 8.Von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and future directions. Radiology. 2006;238:405–422. doi: 10.1148/radiol.2382041977. [DOI] [PubMed] [Google Scholar]
  • 9.Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol. 2003;3:25. doi: 10.1186/1471-2288-3-25. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Whiting PF, Weswood ME, Rutjes AW, Reitsma JB, Bossuyt PN, Kleijnen J. Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies. BMC Med Res Methodol. 2006;6:9. doi: 10.1186/1471-2288-6-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Zamora J, Abraira V, Muriel A, Khan K, Coomarasamy A. Meta-DiSc: a software for meta-analysis of test accuracy data. BMC Med Res Methodol. 2006;6:31. doi: 10.1186/1471-2288-6-31. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Fencl P, Belohlavek O, Skopalova M, Jaruskova M, Kantorova I, Simonova K. Prognostic and diagnostic accuracy of [18F]FDG-PET/CT in 190 patients with carcinoma of unknown primary. Eur J Nucl Med Mol Imaging. 2007;34:1783–1792. doi: 10.1007/s00259-007-0456-8. [DOI] [PubMed] [Google Scholar]
  • 13.Nassenstein K, Veit-Haibach P, Stergar H, et al. Cervical lymph node metastases of unknown origin: primary tumor detection with whole-body positron emission tomography/computed tomography. Acta Radiol. 2007;23:1–8. doi: 10.1080/02841850701581768. [DOI] [PubMed] [Google Scholar]
  • 14.Fleming AJ, Jr, Smith SP, Jr, Paul CM, et al. Impact of [18F]-2-fluorodeoxyglucose-positron emission tomography/computed tomography on previously untreated head and neck cancer patients. Laryngoscope. 2007;117:1173–1179. doi: 10.1097/MLG.0b013e31805d017b. [DOI] [PubMed] [Google Scholar]
  • 15.Bruna C, Journo A, Netter F, et al. On the interest of PET with 18F-FDG in the management of cancer of unknown primary (CUP) Med Nucl. 2007;31:242–249. [Google Scholar]
  • 16.Wartski M, Le Stanc E, Gontier E, et al. In search of an unknown primary tumor presenting with cervical metastases: performance of hybrid FDG-PET-CT. Nucl Med Commun. 2007;28:365–371. doi: 10.1097/MNM.0b013e3280708edf. [DOI] [PubMed] [Google Scholar]
  • 17.Paul SA, Stoeckli SJ, von Schulthess GK, Goerres GW. FDG PET and PET/CT for the detection of the primary tumor in patients with cervical non-squamous cell carcinoma metastasis of an unknown primary. Eur Arch Otorhinolaryngol. 2007;264:189–195. doi: 10.1007/s00405-006-0177-9. [DOI] [PubMed] [Google Scholar]
  • 18.Ambrosini V, Nanni C, Rubello D, et al. 18F-FDG PET/CT in the assessment of carcinoma of unknown primary origin. Radiol Med (Torino) 2006;111:1146–1155. doi: 10.1007/s11547-006-0112-6. [DOI] [PubMed] [Google Scholar]
  • 19.Schneider K, Hrasky A, Aschoff P, Bihl H, Hagen R. Significance of PET and integrated PET/CT in the diagnostics of occult primary tumors. Laryngorhinootologie. 2006;85:819–823. doi: 10.1055/s-2006-925297. [DOI] [PubMed] [Google Scholar]
  • 20.Fakhry N, Barberet M, Lussato D, et al. Role of [18F]-FDG PET-CT in the management of the head and neck cancers. Bull Cancer. 2006;93:1017–1025. [PubMed] [Google Scholar]
  • 21.Schneider K, Aschoff P, Bihl H, Hagen R. The integrated PET/CT: technological advance in diagnostics of head and neck recurrencies and CUP? Laryngorhinootologie. 2006;85:179–183. doi: 10.1055/s-2005-870509. [DOI] [PubMed] [Google Scholar]
  • 22.Pelosi E, Pennone M, Deandreis D, Douroukas A, Mancini M, Bisi G. Role of whole body positron emission tomography/computed tomography scan with 18F-fluorodeoxyglucose in patients with biopsy proven tumor metastases from unknown primary site. Q J Nucl Med Mol Imaging. 2006;50:15–22. [PubMed] [Google Scholar]
  • 23.Maldonado A, Gonzalez Alenda J. The anatomicometabolic PET-CT in carcinoma of unknown primary site. Oncologia (Spain) 2006;29:93–94. doi: 10.1159/000091149. [DOI] [Google Scholar]
  • 24.Fakhry N, Jacob T, Paris J, et al. Contribution of 18-F-FDG PET for detection of head and neck carcinomas with an unknown primary tumor. Ann Otolaryngol Chir Cervicofac. 2006;123:17–25. doi: 10.1016/S0003-438X(06)76634-8. [DOI] [PubMed] [Google Scholar]
  • 25.Zanation AM, Sutton DK, Couch ME, Weissler MC, Shockley WW, Shores CG. Use, accuracy, and implications for patient management of [18F]-2-fluorodeoxyglucose-positron emission/computerized tomography for head and neck tumors. Laryngoscope. 2005;115:1186–1190. doi: 10.1097/01.MLG.0000163763.89647.9F. [DOI] [PubMed] [Google Scholar]
  • 26.Nanni C, Rubello D, Castellucci P, et al. Role of 18F-FDG PET-CT imaging for the detection of an unknown primary tumor: preliminary results in 21 patients. Eur J Nucl Med Mol Imaging. 2005;32:589–592. doi: 10.1007/s00259-004-1734-3. [DOI] [PubMed] [Google Scholar]
  • 27.Freudenberg LS, Fischer M, Antoch G, et al. Dual modality of 18F-fluorodeoxyglucose-positron emission tomography/computed tomography in patients with cervical carcinoma of unknown primary. Med Princ Pract. 2005;14:155–160. doi: 10.1159/000084632. [DOI] [PubMed] [Google Scholar]
  • 28.Syed R, Bomanji JB, Nagabhushan N, et al. Impact of combined (18)F-FDG PET/CT in head and neck tumors. Br J Cancer. 2005;92:1046–1050. doi: 10.1038/sj.bjc.6602464. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Gutzeit A, Antoch G, Kühl H, et al. Unknown primary tumors: detection with dual-modality PET/CT – initial experience. Radiology. 2005;234:227–234. doi: 10.1148/radiol.2341031554. [DOI] [PubMed] [Google Scholar]
  • 30.Rödel R, Straehler-Pohl HJ, Palmedo H, et al. PET/CT imaging in head and neck tumors. Radiologe. 2004;44:1055–1059. doi: 10.1007/s00117-004-1125-6. [DOI] [PubMed] [Google Scholar]
  • 31.Blaszyk H, Hartmann A, Bjornsson J. Cancer of unknown primary origin: a decade of experience in a community-based hospital. Am J Surg. 2007;194:833–837. doi: 10.1016/j.amjsurg.2007.08.039. [DOI] [PubMed] [Google Scholar]
  • 32.Al-Brahim N, Ross C, Carter B, Chorneyko K. The value of postmortem examination in cases of metastasis of unknown origin-20-year retrospective data from a tertiary care center. Ann Diagn Pathol. 2005;9:77–80. doi: 10.1016/j.anndiagpath.2004.12.003. [DOI] [PubMed] [Google Scholar]
  • 33.Mayordomo JI, Guerra JM, Guijarro C, et al. Neoplasms of unknown primary site: a clinicopathological study of autopsied patients. tumori. 1993;79:321–324. doi: 10.1177/030089169307900507. [DOI] [PubMed] [Google Scholar]
  • 34.Le Chevalier T, Cvitkovic E, Caille P, et al. Early metastatic cancer of unknown primary origin at presentation. A clinical study of 302 consecutive autopsied patients. Arch Intern Med. 1988;148:2035–2039. doi: 10.1001/archinte.148.9.2035. [DOI] [PubMed] [Google Scholar]
  • 35.Werner JA, Dünne AA, Myers JN. Functional anatomy of the lymphatic drainage system of the upper aerodigestive tract and its role in metastasis of squamous cell carcinoma. Head Neck. 2003;25:322–332. doi: 10.1002/hed.10257. [DOI] [PubMed] [Google Scholar]
  • 36.Mawlawi O, Pan T, Macapinlac HA. PET/CT imaging techniques, considerations, and artifacts. J Thorac Imaging. 2006;21:99–110. doi: 10.1097/00005382-200605000-00002. [DOI] [PubMed] [Google Scholar]
  • 37.Truong MT, Pan T, Erasmus JJ. Pitfalls in integrated CT-PET of the thorax: implications in oncologic imaging. J Thorac Imaging. 2006;21:111–122. doi: 10.1097/00005382-200605000-00003. [DOI] [PubMed] [Google Scholar]
  • 38.Blodgett TM, Fukui MB, Snyderman CH, et al. Combined PET-CT in the head and neck: part 1. Physiologic, altered physiologic, and artifactual FDG uptake. Radiographics. 2005;25:897–912. doi: 10.1148/rg.254035156. [DOI] [PubMed] [Google Scholar]
  • 39.Lim HS, Yoon W, Chung TW, et al. FDG PET/CT for the detection and evaluation of breast diseases: usefulness and limitations. Radiographics. 2007;27(suppl 1):S197–S213. doi: 10.1148/rg.27si075507. [DOI] [PubMed] [Google Scholar]
  • 40.Fischbach F, Knollmann F, Griesshaber V, Freund T, Akkol E, Felix R. Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol. 2003;13:2378–2383. doi: 10.1007/s00330-003-1915-7. [DOI] [PubMed] [Google Scholar]
  • 41.Ay MR, Zaidi H. Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET. Eur J Nucl Med Mol Imaging. 2006;33:1301–1313. doi: 10.1007/s00259-006-0086-6. [DOI] [PubMed] [Google Scholar]
  • 42.Antoch G, Freudenberg LS, Egelhof T, et al. Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans. J Nucl Med. 2002;43:1339–1342. [PubMed] [Google Scholar]
  • 43.Lauenstein TC, Semelka RC. Emerging techniques: whole-body screening and staging with MRI. J Magn Reson Imaging. 2006;24:489–498. doi: 10.1002/jmri.20666. [DOI] [PubMed] [Google Scholar]
  • 44.Runge VM. Safety of magnetic resonance contrast media. Top Magn Reson Imaging. 2001;12:309–314. doi: 10.1097/00002142-200108000-00007. [DOI] [PubMed] [Google Scholar]
  • 45.Plathow C, Walz M, Lichy MP, et al. Cost considerations for whole-body MRI and PET/CT as part of oncologic staging. Radiologe. 2008;48:384–396. doi: 10.1007/s00117-007-1547-z. [DOI] [PubMed] [Google Scholar]
  • 46.Eustace S, Tello R, DeCarvalho V, Carey J, Melhem E, Yucel EK. Whole body turbo STIR MRI in unknown primary tumor detection. J Magn Reson Imaging. 1998;8:751–753. doi: 10.1002/jmri.1880080336. [DOI] [PubMed] [Google Scholar]
  • 47.Brauck K, Zenge MO, Vogt FM, et al. Feasibility of whole-body MR with T2- and T1-weighted real-time steady-state free precession sequences during continuous table movement to depict metastases. Radiology. 2008;246:910–916. doi: 10.1148/radiol.2463062017. [DOI] [PubMed] [Google Scholar]
  • 48.Kwee TC, Takahara T, Ochiai R, Nievelstein RAJ, Luijten PR. Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): features and potential applications in oncology. Eur Radiol. 2008;18:1937–1952. doi: 10.1007/s00330-008-0968-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Schapira DV, Jarrett AR. The need to consider survival, outcome, and expense when evaluating and treating patients with unknown primary carcinoma. Arch Intern Med. 1995;155:2050–2054. doi: 10.1001/archinte.155.19.2050. [DOI] [PubMed] [Google Scholar]
  • 50.Raber MN, Faintuch J, Abbruzzese JL, Sumrall C, Frost P. Continuous infusion 5-fluorouracil, etoposide and cis-diamminedichloroplatinum in patients with metastatic carcinoma of unknown primary origin. Ann Oncol. 1991;2:519–520. doi: 10.1093/oxfordjournals.annonc.a058007. [DOI] [PubMed] [Google Scholar]
  • 51.Haas I, Hoffmann TK, Engers R, Ganzer U. Diagnostic strategies in cervical carcinoma of an unknown primary (CUP) Eur Arch Otorhinolaryngol. 2002;259:325–333. doi: 10.1007/s004050100408. [DOI] [PubMed] [Google Scholar]

Articles from European Radiology are provided here courtesy of Springer