Abstract
In quantitative dynamic PET studies, graphical analysis methods including the Gjedde-Patlak plot, the Logan plot, and the relative equilibrium-based graphical plot (RE plot) (Zhou et al., 2009b) are based on the theory of a compartmental model with assumptions on tissue tracer kinetics. If those assumptions are violated, then the resulting estimates may be biased. In this study, a multi-graphical analysis method was developed to characterize the non-relative equilibrium effects on the estimates of total distribution volume (DVT) from the RE plot. A novel bi-graphical analysis method using the RE plot with the Gjedde-Patlak plot (RE-GP plots) was proposed to estimate DVT for the quantification of reversible tracer kinetics that may not be at relative equilibrium states during PET study period. The RE-GP plots, and the Logan plot were evaluated by 19 [11C]WIN35,428 and 10 [11C]MDL100,907 normal human dynamic PET studies with brain tissue tracer kinetics measured at both region of interest (ROI) and pixel levels. A 2-tissue compartment model (2TCM) was used to fit ROI time activity curves (TACs). By applying multi-graphical plots to the 2TCM fitted ROI TACs which were considered as the noise free tracer kinetics, the estimates of DVT from the RE-GP plots, the Logan plot, and the 2TCM fitting were equal to each other. For the measured ROI TACs, there was no significant difference between the estimates of the DVT from the RE-GP plots and those from 2TCM fitting (p = 0.77), but the estimates of the DVT from the Logan plot were significantly (p < 0.001) lower, 2.3% on average, than those from 2TCM fitting. There was a highly linear correlation between the ROI DVT form the parametric images (Y) and those from the ROI kinetics (X) by using the RE-GP plots (Y = 1.01X + 0.23, R2 = 0.99). For the Logan plot, the ROI estimates from the parametric images were 13% to 83% lower than those from ROI kinetics. The computational time for generating parametric images was reduced by 69% on average by the RE-GP plots in contrast to the Logan plot. In conclusion, the bigraphical analysis method using the RE-GP plots was a reliable, robust and computationally efficient kinetic modeling approach to improve the quantification of dynamic PET.
Keywords: Gjedde-Patlak plot, Logan plot, relative equilibrium, RE plot, PET
Introduction
In quantitative dynamic PET studies, compartment modeling with plasma input is usually considered as the standard approach for a full analysis of tracer kinetics (Carson 1986; Gunn et al., 2001; Huang et al., 1980, 1986; Huang and Phelps, 1986; Koeppe et al., 1991; Turkheime et al., 2003). A compartmental model is usually described by a number of differential equations and parameters for tracer kinetic process in vivo. The parameters of a compartmental model are commonly estimated by fitting the model with measured plasma input to the measured tissue time activity curves (TACs) using nonlinear or linear regression. The selection of a specific compartment model requires the knowledge of in vivo tracer biochemical and physiological processes and the evaluation of model fit. By focusing on the macro-parameters of tracer kinetics such as uptake rate constant Ki and total distribution volume (DVT), the laborious and complicated procedure of the classical compartmental modeling technique can be remarkably simplified by graphical analysis methods using the Gjedde-Patlak plot (Gjedde 1981; Patlak et al., 1983, 1985; Wong et al., 1986) and the Logan plot (Logan et al., 1990). In general, the Gjedde-Patlak plot is used to estimate Ki for irreversible tracer kinetics, and the Logan plot is used to estimate DVT for reversible tracer kinetics (Logan 2003). However, due to the limited durations of the PET scans, some slowly reversible tracer kinetics are also considered as approximately irreversible for graphical analysis using Gjedde-Patlak plot, such as [18F]FDG (Huang et al., 1980; Zhou et al., 2002) and [11C]PIB dynamic PET scans (Blomquist et al., 2008; Edison et al., 2009).
Due to their simplicity, computational efficiency, and readily apparent visual representation of tracer kinetic behavior, the graphical analysis methods including the Gjedde-Patlak plot and the Logan plot have been widely used to quantify dynamic PET data. The application of the Logan plot is limited by the noise level of tissue tracer concentration. There are noise-induced negative biases in the estimates of DVT from the Logan plot, and the underestimation is dependent on both the noise level and magnitude of the tissue concentration (Abi-Dargham et al., 2000; Kimura et al., 2007; Slifstein and Laruelle, 2000). Based on the Logan plot, a few numerical methods have been proposed to reduce the noise-induced negative bias but with higher variation in DVT estimates and higher computational cost (Buchert et al., 2003; Joshi et al., 2007; Varga and Szabo, 2002; Ogden 2003).
A relative equilibrium-based graphical analysis method was recently proposed to improve the pixelwise quantification of [11C]PIB and [11C]raclopride dynamic PET (Zhou et al., 2009a, 2009b). The graphical analysis method is based on the assumption that the tissue tracer kinetics attain an equilibrium relative to the input function for t ≥ t*, and the relative equilibrium-based graphical plot (RE plot) (same as the “New plot” named in Zhou et al., 2009b) attains a straight line for t ≥ t*, where the slope of linear portion (t ≥ t*) equals the DVT if plasma input is used. It was shown that the RE plot is a consistent and computationally efficient graphical analysis method to improve pixelwise quantification of reversible tracer binding in radioligand-receptor dynamic PET studies (Zhou et al., 2009b).
For dynamic PET scan with tracer delivered by bolus administration, reversible tissue tracer kinetics may not be able to attain a relative equilibrium state during the period of PET scanning. The violations in the relative equilibrium condition for the RE plot may result in biased estimates, although its plot could attain a straight line for t ≥ t*. In this study, a data-driven multi-graphical analysis was used to analyze the non-relative equilibrium effects on the estimates of DVT from the RE plot. A bi-graphical analysis method using the RE plot with the Gjedde-Patlak plot (RE-GP plots) was proposed to estimate DVT for quantification of reversible tracer kinetics that may not be at relative equilibrium states during PET study period. The RE plot, the RE-GP plots, and the Logan plot were evaluated by 19 [11C]WIN35,428 ([11C]WIN) and 10 [11C]MDL100,907 ([11C]MDL) normal human dynamic PET studies with tissue tracer kinetics measured at both region of interest (ROI) and pixel levels.
Materials and Methods
Data-driven multi-graphical analysis for reversible tracer kinetics
The condition for the multi-graphical analysis is that there is t* such that the following three graphical plots attain linearity for t ≥ t*,
| (1) |
| (2) |
| (3) |
where CP(t) is the tracer concentration in plasma from arterial blood sampling, C(t) is the tissue tracer concentration at time t, DVRE and DVL are the distribution volumes estimated by the slope of the linear portion of the RE plot and the Logan plot, respectively, KP is the slope of the linear portion of the Gjedde-Patlak plot, and α, β, and γ are the Y intercepts of the line over the linear segments (t ≥ t*) for the RE plot, the Gjedde-Patlak plot, and the Logan plot, respectively. Usually, the values of α and γ from the RE plot and the Logan plot are negative, and the value of β is positive.
Note that any one of above three plots can be derived from the other two graphical plots. Specifically, the Logan plot can be derived from the RE-GP plots with simple algebraic operation for t ≥ t*.
| (4) |
Let
| (5) |
| (6) |
and compare Eq. (4) with Eq. (3), we have DVL = DVRE-GP = DVRE - αKP/β, and γ = γRE-GP = α/β, i.e., the DVL and γ from the Logan plot can be calculated by the slopes and intercepts from the RE-GP plots.
The above derivation is based on the noise free tracer kinetics similar to the derivations of the Gjedde-Patlak plot (Patlak et al., 1983), the Logan plot (Logan et al., 1990), and the RE plot (Zhou et al., 2009b) from deterministic compartment models. Therefore, the DVRE-GP =DVL if and only if the noise in the tissue tracer kinetics is negligible.
Based on Eq. (5), the DVT estimated by the RE-GP plots can be decomposed by two components: 1) the first component is contributed by the relative equilibrium component that can be estimated by RE plot as DVRE, and 2) the second component is contributed by the non-relative equilibrium component DVNRE that can be estimated by the RE-GP plots as DVNRE = −αKP/β. The DVNRE is greater than 0 if the tracer clearance from tissue is slow relative to plasma (KP >0), and less than 0 if the tracer clearance from tissue is fast relative to plasma (KP < 0) for t ≥ t*. The DVNRE is zero if and only if KP = 0, i.e., the DVRE = DVL if and only if the tracer kinetics attains relative equilibrium for t ≥ t*.
DVT images generated by the RE-GP plots
Due to the high noise levels of pixel tracer kinetics, the parametric images of KP and β generated by the Gjedde-Patlak plot are usually of high statistical variation. In addition, since division is not a stable operation (Lang et al., 1999), the high variance of KP and β can result in the large error propagation in the pixelwise calculation of DVT using Eq. (5) that is associated with the division of –αKP/β. On the other hand, it has been shown that both the RE plot and the Gjedde-Patlak plot are consistent graphical methods in term of following two characteristics: 1) the statistical expectations of the slope and intercept from graphical plot with given input are independent of the noise of the target tissue concentration measured by PET; and 2) the slope and intercept from the ROI TAC are identical to those from the parametric images (Zhou et al., 2009b). Therefore, Eq. (7) below was proposed to generate the DVT images using the RE-GP plots.
| (7) |
where sKP and sβ are obtained by applying a spatial linear smoothing filter to the images of KP and β. A 2-D spatial smoothing mean filter (square mask window, equal weighting for all pixels) is usually selected for high noise level of dynamic PET images (Zhou et al., 2003).
Applications to human dynamic PET studies
To investigate the effects of non-relative equilibrium tissue tracer kinetics on the estimates of DVT from the RE plot, [11C]WIN and [11C]MDL dynamic PET studies for brain imaging of healthy volunteers were collected in this study. There were 19 (6 females, 13 males, age 29.0 ± 7.9 (mean ± standard deviation hereafter) with range of 18 to 47 years) subjects for [11C]WIN PET scans, and 10 subjects (5 female, 5 male, age 33.2 ± 8.2 with range of 21 to 44 years) for [11C]MDL PET scans. While [11C]WIN was used for in vivo imaging dopamine transporter density (Cumming et al., 1999; Frost et al., 1993), [11C]MDL was used for imaging serotonin 5-HT2A receptor density (Gründer et al., 1997; Hall et al., 2000; Lundkvist et al., 1996). All dynamic PET scans were performed on a GE Advance scanner. The PET scanning was started immediately after the intravenous bolus tracer injection of 18.4 ± 1.4 mCi (range 15.8 to 21.6 mCi) with high specific activity of 23723.7 ± 45842.3 mCi/µmol (range 3925.7 to 191837.0 mCi/µmol) for [11C]WIN, and 18.2 ± 4.1 mCi (range 12.8 to 20.8 mCi) with high specific activity of 12775.7 ± 14786.9 mCi/µmol (range 2774.0 to 52780.7 mCi/µmol) for [11C]MDL at time of injection. Metabolite-corrected plasma input functions were obtained for each study by arterial blood sampling. Dynamic PET data were collected in 3-D acquisition mode with protocols of 4×0.25, 4×0.5, 3×1, 2×2, 5×4, 12×5 min (total 90 min, 30 frames) for all scans. To minimize head motion during PET scanning, all participants were fitted with thermoplastic face masks for the PET imaging. Ten-minute 68Ge transmission scans acquired in 2-D mode were used for attenuation correction of the emission scans. Dynamic images were reconstructed using filtered back projection with a ramp filter (image size 128×128, pixel size 2×2 mm2, slice thickness 4.25 mm), which resulted in a spatial resolution of about 4.5 mm full-width at half-maximum (FWHM) at the center of the field of view. The decay-corrected reconstructed dynamic images were expressed in µCi/mL. Structural magnetic resonance images (MRIs) (124 slices with image matrix 256×256, pixel size 0.94×0.94 mm2, slice thickness 1.5 mm) were also obtained with a 1.5 Tesla GE Signa system for each subject. MRIs were co-registered to the mean of all frames’ dynamic PET images using SPM2 with mutual information method. Three ROIs of caudate, cerebellum, and putamen for [11C]WIN, and eleven ROIs of caudate, cerebellum, cingulate, occipital, orbital frontal, parietal, prefrontal, putamen, superior frontal, temporal, and thalamus for [11C]MDL were manually drawn on the co-registered MRIs. ROIs defined on MRIs were copied to the dynamic PET images to obtain ROI TACs.
DVT estimated from ROI kinetics
A two-tissue five-parameter ([K1, k2, k3, k4, VP]) compartment model (2TCM) in sequential configuration (Koeppe et al., 1990; Huang et al., 1986; Innis et al., 2007) was used in [11C]WIN and [11C]MDL dynamic PET studies for ROI kinetic modeling (Brownell et al., 1999; Hinz et al., 2007; Ichise et al., 2003; Ito et al., 1998; Watabe et al., 2000; Wong et al., 1993; Zhou et al., 2004), and the cerebellum was identified as the reference tissue for the quantification of [11C]WIN and [11C]MDL specific binding. To reduce the variation of DVT resulting from the estimates of k4, a nonlinear model fitting algorithm with k4 coupled over all ROIs for each dynamic PET study (Cunningham et al., 2004; Zhou et al., 2007) was performed by following three steps. Step1: Five parameters ([K1, k2, k3, k4, VP]) of the 2TCM model were estimated for all ROI TACs by conventional nonlinear regression with the same initial estimates of ([0.1 0.05 0.01 0.05 0.05]). Step2: The initial estimates for each ROI were updated by the means of estimates over all PET scans, and five parameters of the 2TCM were then re-estimated using the updated initial values for nonlinear regression. Step 3: The estimates from the step 2 were then adjusted by one more nonlinear regression using step 2, but the mean of k4 estimates from the step 2 over all ROIs of each subject was fixed during nonlinear regression. A Marquardt algorithm (Marquardt 1963) was used for nonlinear regression to minimize least squares. The DVT estimated by the 2TCM from ROI TACs was calculated as (K1/k2)(1+k3/k4) + VP after model fitting. Akaike Information criterion (AIC) (Akaike 1976; Turkheimer et al., 2003 Zhou et al., 2007) was calculated after model fitting at Step 2 and model fitting with k4 coupling (Step 3). The AIC and the percent of coefficient of variation of DVT estimation were used to evaluate the performance of nonlinear model fitting.
The plot of time t versus C(t)/CP(t) was used to evaluate the constancy of C(t)/CP(t) for t ≥ t* for the relative equilibrium condition of tissue kinetics (Zhou et al., 2009b). The RE plot, the Gjedde-Patlak plot, and the Logan plot were applied to all measured ROI TACs with t* = 40 min. To evaluate the noise effects on the estimates from graphical plots, the three graphical plots were also applied to the 2TCM fitted ROI TACs of noise free tissue tracer kinetics. Eq. (5) was used for the DVT estimated by the RE-GP plots.
Parametric images generated by the RE-GP plots
The RE plot, the Gjedde-Patlak plot, and Logan plot were applied to pixelwise kinetics. Eq. (7) was used for the DVT images to be generated by the RE-GP plots. Two 2-D spatial smoothing filters, one using window size 7×7 pixel2 for [11C]WIN and the other using window size 9×9 pixel2 for [11C]MDL were selected empirically in this study.
The tracer binding potential (BP), an index of reversible specific binding in radioligand receptor PET studies, was calculated as BP = DVT/DVT(cerebellum) - 1, where the DVT(cerebellum) is the DVT of reference tissue (cerebellum) and is used for the DV of free plus nonspecific binding (Huang et al., 1986; Koeppe et al., 1991; Mintun et al., 1984; Innis et al., 2007; Zhou et al., 2009b).
Results
Non-relative equilibrium of tissue tracer kinetics
The ratio (C(t)/CP(t)) of the ROI concentration to the plasma input increased as a function of time in all the ROIs in the [11C]MDL studies, but only in the caudate and the putamen in the [11C]WIN studies (Fig. 1). In the [11C]WIN studies the increased rates of the ratio (slope of regression) obtained by linear regression of C(t)/CP(t) versus t over the later time frame [40 90] were significantly (p < 0.0001) greater then zero for all the ROIs except for the cerebellum. Note that the cerebellum to plasma input concentration ratio was stable with less than 6% change over the time frame of [40 90] in [11C]WIN studies.
Fig. 1.
The mean ± standard deviation of C(t)/CP(t) as a function of time post tracer injection for [11C]WIN (n=19) (Fig. 1A) and [11C]MDL (n=10) (Fig. 1B). The C(t) is the tissue tracer concentration obtained by applying ROIs to the reconstructed dynamic images, and CP(t) is the metabolite-corrected tracer concentration in plasma. All plots of mean C(t)/CP(t) were increasing for t ≥ 42.5 min except the plot for [11C]WIN cerebellum attained a constant level.
The non-relative equilibrium of tissue tracer kinetics was also shown by the Gjedde-Patlak plot. The positive slope (KP) of the Patlak plot demonstrated that the C(t)/CP(t) was increasing as the normalized time ∫CP(τ)dτ/CP(t) increases (see Table 2).
Table 2.
Estimates (mean (SD)) from ROI kinetics with graphical plots
| [11C]WIN35,428 human dynamic PET studies (n=19) | |||||||
|---|---|---|---|---|---|---|---|
| RE plot | Gjedde-Patlak plot | RE-GP plots | Logan plot | ||||
| ROI | DVRE | −α | KP | β | DVRE-GP | DVL | −γ |
| Cerebellum | 6.068 (0.535) | 133.758 (35.450) | −0.004 (0.010) | 7.065 (1.351) | 5.986 (0.476) | 5.980 (0.478) | 18.708 (2.800) |
| Caudate | 21.975 (3.173) | 1110.212 (285.886) | 0.152 (0.022) | 9.044 (2.150) | 41.036 (6.532) | 39.691 (6.266) | 118.454 (19.247) |
| Putamen | 24.212 (3.314) | 1217.044 (303.824) | 0.170 (0.020) | 9.720 (2.264) | 45.771 (5.896) | 44.607 (5.957) | 121.785 (17.258) |
| [11C] MDL100,907 human dynamic PET studies (n=10) | |||||||
| ROI | DVRE | −α | KP | β | DVRE-GP | DVL | −γ |
| Cerebellum | 17.306 (2.430) | 1699.938 (440.297) | 0.056 (0.025) | 23.190 (6.412) | 21.551 (3.132) | 21.486 (3.162) | 73.782 (8.000) |
| Caudate | 20.186 (2.933) | 2028.418 (519.275) | 0.073 (0.028) | 25.350 (7.379) | 26.334 (3.895) | 24.711 (4.131) | 71.893 (9.907) |
| Cingulate | 31.688 (5.292) | 3699.212 (1008.593) | 0.223 (0.045) | 18.613 (5.854) | 76.894 (12.831) | 74.773 (13.490) | 195.102 (24.510) |
| Occipital | 26.957 (3.186) | 3103.918 (686.460) | 0.185 (0.040) | 16.686 (3.584) | 62.102 (11.946) | 61.218 (11.737) | 183.897 (20.524) |
| Orbital Frontal |
27.920 (5.481) | 3263.843 (966.932) | 0.199 (0.045) | 15.656 (5.420) | 70.470 (13.031) | 68.174 (14.269) | 203.428 (15.832) |
| Parietal | 27.174 (4.464) | 3164.216 (885.125) | 0.188 (0.040) | 16.707 (5.295) | 63.584 (11.308) | 62.838 (11.040) | 189.749 (20.133) |
| Putamen | 28.455 (5.282) | 3331.725 (985.927) | 0.204 (0.047) | 15.619 (4.222) | 72.524 (16.399) | 71.052 (16.786) | 207.568 (21.505) |
| Prefrontal | 20.512 (2.406) | 1985.594 (456.804) | 0.067 (0.029) | 27.076 (7.095) | 25.624 (3.254) | 24.954 (3.236) | 70.609 (7.454) |
| Superior Frontal |
28.627 (5.657) | 3368.900 (1028.899) | 0.205 (0.048) | 15.814 (4.670) | 72.971 (16.875) | 71.661 (17.266) | 208.378 (21.592) |
| Lateral Temporal |
27.967 (4.820) | 3318.133 (957.878) | 0.211 (0.044) | 13.286 (4.146) | 81.858 (16.167) | 79.650 (16.920) | 244.569 (29.083) |
| Thalamus | 21.056 (2.771) | 2096.463 (482.257) | 0.070 (0.034) | 28.132 (7.658) | 26.565 (4.051) | 26.006 (3.871) | 72.885 (8.201) |
Two-tissue compartment model fitting for ROI kinetics
Paired TACs from two typical studies with fitted kinetics, one from reference tissue (cerebellum) of negligible specific binding, and one from target tissue of high specific binding (putamen for [11C]WIN, lateral temporal cortex for [11C]MDL), were plotted in Fig.2. All ROI TACs were well fitted consistently by the 2TCM with k4 coupling. The percent coefficient of variation (=100*standard deviation /mean) of AIC was as low as (8.186 ± 2.185)% (n=3) for [11C]WIN and (11.344 ± 2.210)% (n=11) for [11C]MDL. In contrast to the AICs from 2TCM model fitting with k4 coupling, the AICs from the 2TCM without k4 coupling decreased (−0.076 ± 2.411)% and (0.532 ± 3.925)% for [11C]WIN and [11C]MDL, respectively. The percent reductions in AICs by using the 2TCM model fitting without k4 coupling were not significant for both [11C]WIN (p = 0.871) and [11C]MDL (p = 0.248) studies.
Fig. 2.
Typical tissue time activity curves from a [11C]WIN and a [11C]MDL human dynamic PET studies. The fitted curves were obtained by a 2-tissue 5-parameter ([K1, k2, k3, k4, VP]) compartment model (2TCM) fitting with plasma input. A nonlinear regression algorithm with k4 coupled over all ROIs was used for model fitting (see Materials and Methods section).
The micro-parameters of ([K1, k2, k3, k4, VP]) estimated from ROI TACs using 2TCM model with k4 coupling and macro-parameter DVT were listed in Table 1. The percent differences (=100*(DVT(no k4 coupling)- DVT(k4 coupling))/ DVT(k4 coupling)) between the estimates of [11C]WIN DVT from ROI TACs using 2TCM fitting without k4 coupling and those with k4 coupling were ((−0.173 ± 1.130)%, (0.080 ± 0.581)%, (0.914 ± 1.474)%) for the ROIs of (cerebellum, caudate, putamen). The percent coefficients of variation of [11C]WIN DVT obtained from ROI TACs of (cerebellum, caudate, putamen) using 2TCM fitting without k4 coupling were (8.243%, 17.346%, 12.977%) and were similar to those from 2TCM fitting with k4 coupling (Table 1). However, there were a few outliers in the estimates of [11C]MDL DVT obtained by 2TCM fitting without k4 coupling, and the percent differences between the estimates of [11C]MDL DVT from ROI TACs using 2TCM fitting without k4 coupling and those with k4 coupling were ((4.064 ± 5.287)%, (4.540 ± 10.092)%, (0.029 ± 1.490)%, (11.944 ± 34.445)%, (1.843 ± 3.067)%, (0.182 ± 0.955)%, (5.699 ± 16.063)%, (12.155 ± 14.550)%, (0.141 ± 0.746)%, (0.796 ± 1.047)%, (2.479 ± 6.183)%) for the ROIs of (cerebellum, caudate, cingulate, occipital, orbital frontal, parietal, prefrontal, putamen, superior frontal, temporal, and thalamus). The percent coefficient of variation of [11C]MDL DVT obtained from ROI TACs using 2TCM fitting without k4 coupling was reduced (15.0 ± 23.3)% in 11 ROIs with a maximum of 57.0% at occipital cortex by using 2TCM model fitting with k4 coupling.
Table 1.
Estimates (mean (SD)) obtained by fitting a 2-tissue compartment model to ROI kinetics
| [11C]WIN35,428 human dynamic PET studies (n=19) | ||||||
|---|---|---|---|---|---|---|
| ROI | K1 | k2 | k3 | k4 | VP | DVT |
| Cerebellum | 0.347 (0.039) | 0.065 (0.006) | 0.007 (0.004) | 0.077 (0.030) (range 0.037 –0.155) |
0.068 (0.021) | 5.963 (0.497) |
| Caudate | 0.366 (0.042) | 0.077 (0.037) | 0.555 (0.179) | 0.064 (0.021) | 41.868 (7.244) | |
| Putamen | 0.400 (0.037) | 0.069 (0.097) | 0.504 (0.768) | 0.073 (0.021) | 45.206 (5.517) | |
| [11C] MDL100,907 human dynamic PET studies (n=10) | ||||||
| ROI | K1 | k2 | k3 | k4 | VP | DVT |
| Cerebellum | 0.361 (0.051) | 0.041 (0.009) | 0.073 (0.033) | 0.057 (0.040) (range 0.032– 0.162) |
0.070 (0.028) | 21.210 (2.866) |
| Caudate | 0.401 (0.059) | 0.043 (0.022) | 0.078 (0.041) | 0.079 (0.047) | 25.601 (2.974) | |
| Cingulate | 0.413 (0.060) | 0.041 (0.036) | 0.329 (0.304) | 0.080 (0.026) | 78.496 (13.956) | |
| Occipital | 0.365 (0.048) | 0.046 (0.032) | 0.343 (0.264) | 0.057 (0.022) | 62.305 (11.975) | |
| Orbital Frontal |
0.364 (0.061) | 0.035 (0.012) | 0.302 (0.199) | 0.073 (0.027) | 69.189 (14.834) | |
| Parietal | 0.362 (0.049) | 0.058 (0.070) | 0.422 (0.465) | 0.060 (0.019) | 64.507 (11.947) | |
| Putamen | 0.367 (0.056) | 0.027 (0.012) | 0.242 (0.222) | 0.065 (0.021) | 72.667(18.177) | |
| Prefrontal | 0.456 (0.058) | 0.052 (0.013) | 0.093 (0.042) | 0.088 (0.046) | 24.634 (2.510) | |
| Superior Frontal |
0.370 (0.060) | 0.037 (0.012) | 0.328 (0.182) | 0.057 (0.021) | 74.066 (17.510) | |
| Lateral Temporal |
0.349 (0.053) | 0.035 (0.007) | 0.382 (0.215) | 0.066 (0.017) | 81.613 (16.984) | |
| Thalamus | 0.418 (0.064) | 0.038 (0.016) | 0.063 (0.035) | 0.078 (0.033) | 26.603 (3.390) | |
The DVT estimates from ROI TACs using 2TCM fitting with k4 coupling attained stability when the duration of dynamic PET scan was at least 60 min. There were no significant differences between the estimates of DVT from 60-min and 90-min dynamic scans with <5% absolute difference.
Graphical plots for ROI kinetic analysis
The RE plot, the Gjedde-Patlak plot, and the Logan plot were applied to each ROI TAC. The multi-graphical plots were evaluated visually and by regular linear regression with statistical analysis. As demonstrated by Fig.3, all plots generated from ROI kinetics attained linearity in the last 10 points corresponding to the PET scanning time t from 40 to 90 min. The R2s (mean ± SD) of the linear regression on the linear portion of graphical plots for (RE plot, Gjedde-Patlak plot, Logan plot) were (0.998 ± 0.002, 0.813 ± 0.311, 0.986 ± 0.019) (n = 3×19 = 57) and (0.979 ± 0.025, 0.884 ± 0.229, 0.987 ± 0.018) (n = 10×11 = 110) for [11C]WIN and [11C]MDL, respectively. The linear regression of the Gjedde-Patlak plot showed that the KP for the TACs of caudate and putamen in [11C]WIN and for all cortical ROI TACs in [11C]MDL studies were significantly greater than zero (F-test, p < 0.001). The slopes of the linear regression for the Gjedde-Patlak plot from 7 [11C]WIN cerebellum TACs, and 2 [11C]MDL TACs of caudate, putamen, thalamus, cerebellum were not significant different from 0, and R2s of the linear regression were at relative low values (R2 < 0.5).
Fig.3.
Multi-graphical plots for the measured typical ROI time activity curves from a [11C]WIN and a [11C]MDL human dynamic PET studies. All plots attained linearity in the last 10 time points that correspond the time frames from 40 to 90 min post tracer injection.
The estimates from graphical plots including slope and intercept from the linear regression were summarized in Table 2. In [11C]WIN studies, there were no significant difference (< ±1% difference) between the DV of cerebellum from the RE plot (DVRE) and those from the Logan plot (DVL) or the RE-GP plots, because the KP for cerebellum (−0.004 ± 0.010) was not significantly different from 0 (t-test, p = 0.07). The [11C]WIN cerebellum kinetics attained relative equilibrium states for t from 40 to 90 min (see Fig. 1). The values of KP were significantly greater than 0 for caudate and putamen in [11C]WIN, and all 11 ROIs in [11C]MDL studies. Therefore, due to the non-relative equilibrium states in these ROI kinetics, the [11C]WIN DVRE in (caudate, putamen) was lower ((45.9 ± 6.7)%, 46.8 ± 6.2)%), and [11C]MDL DVRE was lower from (19.1 ± 9.2) % at cerebellum to (65.2 ± 6.2) % at lateral temporal cortex, compared to the estimates of DVT from RE-GP plots.
For the relatively low noise levels of the measured ROI kinetics, the DVT estimated from the Logan plot (DVL, Table 2) were lower (p < 0.001) than those (DVRE-GP) from the RE-GP plots (Table 2) and those from 2TCM (Table 1). The values of [11C]WIN DVL in the caudate and the putamen were lower (3.596 ± 4.421)% and (2.887 ± 2.668)% than the DVT from the 2TCM and the RE-GP plots, respectively. The values of [11C]MDL DVL for all 11 ROIs were (1.952 ± 4.518)% and (2.461 ± 3.373)% lower than DVT from the 2TCM and the RE-GP plots, respectively. For the measured ROI kinetics, there were no significant differences between the estimates of DVT from the RE-GP plots and those from 2TCM fitting (p = 0.77). There were highly linear correlations between the estimates of DVT from the RE-GP plots and those from 2TCM or the Logan plot for the measured ROI kinetics (Fig 4A). The effects of ROI kinetic noise on the DVT estimates from graphical plot was demonstrated by Fig. 4A and Fig. 4B. In Fig. 4B, the graphical plots were applied to the fitted ROI TACs for estimating DVT, where the fitted TACs were obtained by fitting a 2TCM model with k4 coupling to the measured ROI TACs. With given plasma input function, the 2TCM fitted ROI TACs can be considered as noise free ROI kinetics. Therefore, the estimates of DVT from the RE-GP plots were almost identical to those from the 2TCM fitting and those from the Logan plot for the 2TCM fitted ROI TACs (Fig. 4B).
Fig. 4.
The linear correlations among the DVT estimates from multi-graphical plots and those from 2-tissue compartment model (2TCM) fitting with k4 coupling from 19 [11C]WIN (3 ROIs) and 10 [11C]MDL (11 ROIs) human dynamic PET studies. The DVT estimates from multi-graphical plots were obtained from the measured (Fig. 4A) and 2TCM fitted ROI time activity curves (TACs) (Fig. 4B). With given plasma input function, the 2TCM fitted ROI TACs can be considered noise as free ROI kinetics, and the measured ROI TACs was used to evaluate the effects of low noise levels on the DVT estimates from the Logan plot and the RE plot with the Gjedde-Patlak plot (RE-GP plots).
Parametric images generated by graphical plots
One set of representative parametric images generated by the RE plot, the Gjedde-Patlak plot, and the Logan plot from a [11C]WIN and a [11C]MDL dynamic PET studies with MRI images are shown in Fig. 5. The noise levels of parametric images in Fig. 5 were similar through all subject studies for each graphical plot. DVT images generated by the Logan plot were noisier than DVT images generated by the RE-GP plots, and the DVRE images were of lowest noise levels. The nonzero pixel values in the KP images demonstrated the non-relative equilibrium pixel tracer kinetics. The higher KP pixel values, the higher difference in the pixel values between the DVT generated by the RE-GP plots and the DVRE from the RE plot. In contrast to the DVT images generated by the RE-GP plots, the DVT images generated from the Logan plot demonstrated remarkably low values with higher noise levels. As the noise of pixel kinetics was increased considerably from the noise level of ROI kinetics, the noise-induced underestimation in the DVT images generated by the Logan plot was much higher than the underestimation in the DVT from ROI kinetics as described below.
Fig. 5.
Transverse parametric images generated by multi-graphical plots in a representative human [11C]WIN and [11C]MDL dynamic PET studies. The MRI and mean images were displayed for reference purpose. The DVT images generated by the Logan plot were of higher noise level and significantly lower than those from the RE plot with the Gjedde-Patlak plot (RE-GP plots). Due to the noise-induced inconsistent underestimation in the DVT estimates, the contrast of the DVT images generated by the Logan plot were markedly decreased. The non-relative equilibrium tracer kinetics was demonstrated by the KP images from the Gjedde-Patlak plot. The underestimation of DVT in the DVRE images generated by the RE plot was resulted from non-relative equilibrium tracer kinetics observed in both [11C]WIN and [11C]MDL studies. The mean and DV images were displayed in µCi/mL and mL/mL unites, respectively.
The DVT parametric images generated by the RE-GP plots and the Logan plot were compared to those from the ROI kinetics. A highly linear correlation between the DVT from the ROI kinetics and those from the parametric images was obtained with R2 = 0.99 and slope = 1.01 that was not significantly different from 1 (p = 0.23) (Fig. 6A). By contrast, a poor linear correlation between the DVT from ROI kinetics and those from parametric images was demonstrated in Fig. 6B for the Logan plot. The poor correlations within each tracer study were also resulted from the inconsistencies in the noise-induced underestimation in the DVT images among the ROIs. The underestimation in the DVT from the parametric images generated from the [11C]MDL studies was greater than that generated from [11C]WIN studies for the Logan plot. As shown in Fig. 7A, the DVT of (cerebellum, caudate, putamen) from the parametric images was lower (13%, 52%, 50%) than those from ROI kinetics for the Logan plot in [11C]WIN studies. The BP of (caudate, putamen) from parametric images was lower (50%, 54%) than those from ROI kinetics (Fig. 7B). Similar results for the [11C]MDL studies are shown in Fig. 8. In contrast to the DVT from ROI kinetics, the ROI DVT from parametric images was lower from 36% at cerebellum to 74% at lateral temporal cortex (Fig. 8A); and the BP from parametric images was lower 83% at lateral temporal cortex for the Logan plot (Fig. 8B).
Fig. 6.
For the RE plot with the Gjedde-Patlak plot (RE-GP plots) (Fig. 6A), there were high linear correlations between the ROI DVT from the parametric images and those from ROI kinetics. The slope of the linear regression was not significantly different from 1 (p = 0.23). Due to the noise-induced inconsistent underestimation in the DVT from the Logan plot, the correlation between the ROI DVT from parametric images and those from ROI kinetics was poor (Fig. 6B).
Fig. 7.
The mean ± standard error of the ROI DVT (Fig 7A) and binding potential (BP) (Fig. 7B) from 19 [11C]WIN normal human dynamic PET studies. The BP was calculated as DVT/DVT(cerebellum) −1.
Fig. 8.
The mean ± standard error of the ROI DVT (Fig 8A) and binding potential (BP) (Fig. 8B) from 10 [11C]MDL normal human dynamic PET studies. The BP was calculated as DVT/DVT(cerebellum) −1.
The total computation time for the parametric images generated by the RE-GP plots was 25.3 ± 0.4 s. and 69% less than the time used by the Logan plot. The computational efficiency of the RE-GP plots will be significant for large volume of dynamic PET data set and parametric image estimation in sinogram space (Rahmim et al., 2009)
Discussion
Conditions for the Logan plot and the RE-GP plots
The Logan plot, the RE plot, and the RE-GP plots are mainly used for the quantification of reversible tracer binding. In this study it was shown that tracer total distribution volume DVT in tissue estimated from the RE plot is unbiased if and only if the tissue tracer kinetics attain equilibrium states relative to plasma input during PET study. Note that the steady state of tissue tracer kinetics is used to derive graphical analysis using the Logan plot with plasma input (Logan et al., 1990), and this condition is stronger than the relative equilibrium condition for the unbiased estimate of DVT from the RE plot. Due to the apparent inconsistency between theoretical and measured results, it is necessary to re-derive the Logan plot with appropriate conditions assumed on the tracer kinetics, although it was also demonstrated by data and discussed analytically that the steady state of tissue tracer kinetics is not necessary for the Logan plot (Logan et al., 1990; Logan 2003; Schmidt and Turkheimer, 2002). The sufficient and necessary condition for the distribution volume DVL obtained by the Logan plot with noise free tissue kinetics to be an unbiased estimates of total distribution volume DVT is that there is t* such that C(t) follows one-tissue compartment model, i.e., for a noise free tissue kinetics, DVL = DVT if and only if there is t* such that C(t) follows one-tissue compartment model. Different from previous derivations (Logan 2003; Kimura et al., 2007), the following theoretical proof for the sufficient condition of the Logan plot is based on a general compartment model configuration for reversible tracer kinetics (Logan et al., 1990; Patlak et al., 1983, 1985; Zhou et al., 2009). For the sufficient condition, assuming all tissue compartments are reversible and there is t* such that all tissue compartments attain equilibrium to each other for t ≥ t*, i.e., tissue tracer kinetics follow one-tissue compartment model, then the Logan plot attain a linearity for t ≥ t*, and the slope of the linear portion equals the DVT. This can be simply derived as shown below. Based on the integration form of tracer kinetics described by the Eq. (8) (same as Eq. 4 in Zhou et al., 2009b)
| (8) |
where CP(t) is plasma input function, A(t) = [C1(t), C2(t), … Cm(t)]′, Ci(t) is the tracer concentration in the ith compartment, ′ is the mathematical transpose operation, K is the system matrix (mxm) and its elements are the transport rate constants between compartments, Q is a mx1column vector of transport rate constants from vascular space to tissue compartments, I is a mx1 column vector of ones, and VP is the effective plasma volume in tissue. For the total tissue tracer concentration C(t) measured by PET, we have C(t) = ΣCi(t) + VPCP(t) = I′A(t) + VPCP(t). Based on the assumption that all tissue compartments attain equilibrium to each other, and VPCP(t) is negligible to C(t) for t ≥ t*, then we have Ci(t) = RiC(t), i = 1, 2,…m, for t ≥ t*, and I′K−1 A(t) = I′K−1RC(t) = γC(t), (γ = I′K−1R is a constant). In addition, -I′K−1Q + VP = ΣDVi +VP = DVT, therefore, we have Eq. (9) below that is same as Eq. (3) for the Logan plot for the noise free tissue kinetics.
| (9) |
This shows that DVL from the Logan plot equals DVT. For the necessary condition, it is assumed that the DVT can be obtained by the Logan plot using Eq. (3). Note that for the noise free tissue concentration C(t), DVT and γ obtained by Eq. (3) are identical to those obtained by Eq. (9). Taking derivative on the both sides of Eq. (9), We have Eq. (10) below.
| (10) |
The intercept of the linear regression from the Logan plot is usually negative, DVT/(-γ) and 1/(-γ) in Eq. (10) can be considered as the transport rate constant from plasma to tissue and transport rate constant from tissue to plasma for t ≥ t*, respectively. This means that the tissue kinetics follow one-tissue compartment model for t ≥ t*.
Based on the necessary and sufficient condition for the Logan plot, if two-tissue compartment model is necessary to describe the tracer kinetics for t ≥ t*, then the DVL form the Logan plot (slope of linear portion of the Logan plot for t ≥ t*) could also be a biased estimate of DVT, although the tracer kinetics is noise-free.
Using the RE-GP plots to quantify reversible tracer binding
In this study, the RE plot was extended to a bi-graphical analysis method using the RE-GP plots to quantify general reversible tracer binding of slow or fast kinetics relative to plasma input. The RE-GP plots are more robust to tracer kinetics than the RE plot for estimating DVT. It was shown that the estimates of DVT obtained by the RE-GP plots are identical to those from the Logan plot for tissue tracer kinetics of negligible noise levels. This means that the necessary and sufficient condition for the unbiased estimate of DVT for the Logan plot is also the basis for the RE-GP plots. However, in contrast to the Logan plot, the estimates of DVT from the RE-GP plots are more robust to noise levels of tissue tracer kinetics, and reliable for generating parametric images of DVT. For the low noise and low resolution dynamic PET images, the DVT images generated by the Logan plot and RE-GP plots are close to the DVT images generated by the RE-GP plots, and their main difference is due to the noise-induced underestimation in the Logan plot. Fig. 9 illustrates that the DVT images generated by the Logan plot and the RE-GP plots are comparable as the DVT images were generated from the spatially smoothed dynamic images for reducing the noise levels of pixel kinetics, where the two representative PET studies in Fig. 9 are the same as those presented in Fig. 5. Due to low noise levels of the spatially smoothed dynamic PET images, Eq. (5) was used in the RE-GP plots for generation of DVT images. The resolution of PET images in Fig. 9 was much lower than those in Fig. 5. Due to partial volume effects resulted from spatially smoothing in dynamic images, the ROI values in the DVT images generated by the RE-GP plots were decreased as high as 29%. In contrast to Fig. 5, the noise-induced underestimation in the DVT images generated by the Logan plot in Fig. 9 was mostly reduced at the high cost of spatial resolution. In contrast to the ROI values in the DVT images generated by the RE-GP plots in Fig. 5, the lower ROI values in the DVT images generated by the Logan plot in Fig. 9 are due to both partial volume effects and noise in pixel kinetics.
Fig. 9.
Transverse parametric images generated by multi-graphical plots in the representative human [11C]WIN and [11C]MDL dynamic PET studies same as those used in the Fig. 5. The MRI and mean images were displayed for reference purpose. Different from the Fig. 5, the mean and parametric images were generated from the spatially smoothed dynamic images, where a 2D mean filter of 7×7 window size and a 2D mean filter of 9×9 window size were used for [11C]WIN and [11C]MDL, respectively. Eq. (5) was used in the RE-GP plots. The mean and DV images were displayed in µCi/mL and mL/mL unites, respectively. As the noise levels of pixel kinetics were markedly reduced by applying spatially smooth filter to the dynamic images, the DVT images generated by the Logan plot were comparable to those generated by the RE-GP plots. The reduced noise-induced underestimation in the DVT images obtained by the Logan plot is at a high cost of spatial resolution.
For the bi-graphical analysis method using the RE-GP plots, the Gjedde-Patlak (GP) plot is mainly used to estimate the distribution volume contributed from the tracer kinetics not at relative equilibrium states (DVNRE). For example, the KP from the Gjedde-Patlak plot was recently used as an index to discriminate the patients of Alzheimer’s disease from controls using [11C]PIB dynamic PET (Blomquist et al., 2008; Edison et al., 2009). One sufficient condition for the KP obtained by the Gjedde-Patlak plot to be an unbiased estimate of Ki is that all reversible compartments in tissue attain effective equilibrium (equilibrium relative to tracer plasma kinetics), and there is at least one irreversible compartment in tissue. Previous studies showed that the KP is a biased estimate of Ki if the reversible compartments are not at relative equilibrium state for t ≥ t* (Yu et al., 1995), or the transport rate constant from the "irreversible" compartments to the reversible compartments are greater than zero (Huang et al., 1980; Patlak et al., 1985).
In summary, non-relative equilibrium was shown in both [11C]WIN and [11C]MDL kinetics over the usual 90 min PET scan time, and the non-relative equilibrium tracer kinetics resulted in the underestimation of the DVT from the RE plot, and the non-relative equilibrium induced underestimation can be corrected by a bi-graphical analysis method using the RE-GP plots. The RE, Gjedde-Patlak, and Logan plots were applied to the measured ROI kinetics for the time from 40 to 90 min post tracer injection. The estimates of DVT from the RE-GP plots were identical to those from the Logan plot for the 2TCM fitted ROIs TACs. For the Logan plot, the ROI estimates from the parametric images were 13% to 83% lower than those from ROI kinetics, and the noise-induced underestimation was dependent on both the noise level of tracer kinetics and the magnitude of DVT and BP. There was a highly linear correlation between the ROI DVT from the parametric images (Y) and those from the ROI kinetics (X) by using the RE-GP plots (Y = 1.01X + 0.23, R2 = 0.99). The computational time for generating parametric images was reduced by 69% on average by the RE-GP plots in contrast to the Logan plot. In conclusion, the bi-graphical analysis method using the RE-GP plots was a robust and computationally efficient kinetic modeling approach to improve the quantification of noisy dynamic PET data.
Acknowledgments
We thank the cyclotron, PET, and MRI imaging staff of the Johns Hopkins Medical Institutions; Andrew H. Crabb for data transfer and computer administration. This work was supported in part by NIH grants DA00412, MH078175, AA12839, AA012837, and AA10158(DFW). This work was presented in part at the 56th Annual Meeting of the Society of Nuclear Medicine, 2009 in Toronto, Canada (Zhou et al., 2009c).
Footnotes
Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
References
- Abi-Dargham A, Martinez D, Mawlawi O, Simpson N, Hwang DR, Slifstein M, Anjilvel S, Pidcock J, Guo NN, Lombardo I, Mann JJ, Van Heertum R, Foged C, Halldin C, Laruelle M. Measurement of striatal and extrastriatal dopamine D1 receptor binding potential with [11C]NNC 112 in humans: validation and reproducibility. J Cereb Blood Flow Metab. 2000;20(2):225–243. doi: 10.1097/00004647-200002000-00003. [DOI] [PubMed] [Google Scholar]
- Blomquist G, Engler H, Nordberg A, Ringheim A, Wall A, Forsberg A, Estrada S, Frandberg P, Antoni G, Langstrom B. Unidirectional influx and net accumulation of PIB, The Open Neuroimaging Journal. 2008;2:114–125. doi: 10.2174/1874440000802010114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brownell AL, Jenkins BG, Isacson O. Dopamine imaging markers and predictive mathematical models for progressive degeneration in Parkinson's disease. Biomed Pharmacother. 1999;53(3):131–140. doi: 10.1016/S0753-3322(99)80078-X. [DOI] [PubMed] [Google Scholar]
- Carson RE. Parameter estimation in positron emission tomograph. In: Phelps M, Mazziotta J, Schelbert H, editors. Positron Emission Tomograph and Autoradiography: Principals and Applications for the Brain and Heart. New York: Raven Press; 1986. pp. 347–390. [Google Scholar]
- Cumming P, Yokoi F, Chen A, Deep P, Dagher A, Reutens D, Kapczinski F, Wong DF, Gjedde A. Pharmacokinetics of radiotracers in human plasma during positron emission tomography. Synapse. 1999;34(2):124–134. doi: 10.1002/(SICI)1098-2396(199911)34:2<124::AID-SYN5>3.0.CO;2-O. [DOI] [PubMed] [Google Scholar]
- Edison P, Brooks DJ, Turkheimer FE, Archer HA, Hinz R. Strategies for the generation of parametric images of [(11)C]PIB with plasma input functions considering discriminations and reproducibility. Neuroimage Epub ahead of print. 2009 doi: 10.1016/j.neuroimage.2009.06.079. [DOI] [PubMed] [Google Scholar]
- Cunningham VJ, Matthews JC, Gunn RN, Rabiner EA, Gee AD. Identification and interpretation of microparameters in neuroreceptor compartmental models. Neuroimage. 2004;22 suppl. 2:T13. [Google Scholar]
- Frost JJ, Rosier AJ, Reich SG, Smith JS, Ehlers MD, Snyder SH, Ravert HT, Dannals RF. Positron emission tomographic imaging of the dopamine transporter with 11C-WIN 35,428 reveals marked declines in mild Parkinson's disease. Ann Neurol. 1993;34(3):423–431. doi: 10.1002/ana.410340331. [DOI] [PubMed] [Google Scholar]
- Gjedde A. High- and low-affinity transport of D-Glucose from blood to brain. J. Neurochem. 1981;36:1463–1471. doi: 10.1111/j.1471-4159.1981.tb00587.x. [DOI] [PubMed] [Google Scholar]
- Gründer G, Yokoi F, Offord SJ, Ravert HT, Dannals RF, Salzmann JK, Szymanski S, Wilson PD, Howard DR, Wong DF. Time course of 5-HT2A receptor occupancy in the human brain after a single oral dose of the putative antipsychotic drug MDL 100,907 measured by positron emission tomography. Neuropsychopharmacology. 1997;17(3):175–185. doi: 10.1016/S0893-133X(97)00044-4. Erratum in: Neuropsychopharmacology 1998, 19(2):161. [DOI] [PubMed] [Google Scholar]
- Gunn RN, Gunn SR, Cunningham VJ. Positron emission tomography compartmental models. J. Cereb. blood Flow Metab. 2001;21:635–652. doi: 10.1097/00004647-200106000-00002. [DOI] [PubMed] [Google Scholar]
- Hall H, Farde L, Halldin C, Lundkvist C, Sedvall G. Autoradiographic localization of 5-HT(2A) receptors in the human brain using [(3)H]M100907 and [(11)C]M100907. Synapse. 2000;38(4):421–431. doi: 10.1002/1098-2396(20001215)38:4<421::AID-SYN7>3.0.CO;2-X. [DOI] [PubMed] [Google Scholar]
- Hinz R, Bhagwagar Z, Cowen PJ, Cunningham VJ, Grasby PM. Validation of a tracer kinetic model for the quantification of 5-HT(2A) receptors in human brain with [(11)C]MDL 100,907. J Cereb Blood Flow Metab. 2007;27(1):161–172. doi: 10.1038/sj.jcbfm.9600323. [DOI] [PubMed] [Google Scholar]
- Huang SC, Barrio JR, Phelps ME. Neuroreceptor assay with positron emission tomography: equilibrium versus dynamic approaches. J Cereb Blood Flow Metab. 1986;6(5):515–521. doi: 10.1038/jcbfm.1986.96. [DOI] [PubMed] [Google Scholar]
- Huang S-C, Phelps M. Principals of tracer kinetic modeling in positron emission tomograph and autoradiography. In: Phelps M, Mazziotta J, Schelbert H, editors. Positron Emission Tomograph and Autoradiography: Principals and Applications for the Brain and Heart. New York: Raven Press; 1986. pp. 287–346. [Google Scholar]
- Huang S-C, Phelps M, Hoffman EJ, et al. Noninvasive determination of local cerebral metabolic rate of glucose in man. Am. J. Physiol. 1980;238:E69–E82. doi: 10.1152/ajpendo.1980.238.1.E69. [DOI] [PubMed] [Google Scholar]
- Ito H, Nyberg S, Halldin C, Lundkvist C, Farde L. PET imaging of central 5-HT2A receptors with carbon-11-MDL 100,907. J Nucl Med. 1998;39(1):208–214. [PubMed] [Google Scholar]
- Ichise M, Toyama H, Innis RB, Carson RE. Strategies to improve neuroreceptor parameter estimation by linear regression analysis. J Cereb Blood Flow Metab. 2003;22(10):1271–1281. doi: 10.1097/01.WCB.0000038000.34930.4E. [DOI] [PubMed] [Google Scholar]
- Innis RB, Cunningham VJ, Delforge J, et al. Consensus nomenclature for in vivo imaging of reversibly binding radioligands. J Cereb Blood Flow Metab. 2007;27(9):1533–1539. doi: 10.1038/sj.jcbfm.9600493. [DOI] [PubMed] [Google Scholar]
- Joshi A, Fessler JA, Koeppe RA. Improving PET receptor binding estimates from Logan plots using principal component analysis. J Cereb Blood Flow Metab. 2007 doi: 10.1038/sj.jcbfm.9600584. Epub ahead of print. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kimura Y, Naganawa M, Shidahara M, Ikoma Y, Watabe H. PET kinetic analysis --pitfalls and a solution for the Logan plot. Ann Nucl Med. 2007;21(1):1–8. doi: 10.1007/BF03033993. [DOI] [PubMed] [Google Scholar]
- Koeppe RA, Holthoff VA, Frey KA, Kilbourn MR, Kuhl DE. Compartmental analysis of [11C]flumazenil kinetics for the estimation of ligand transport rate and receptor distribution using positron emission tomography. J Cereb Blood Flow Metab. 1991;11:735–744. doi: 10.1038/jcbfm.1991.130. [DOI] [PubMed] [Google Scholar]
- Lange K. Numerical Analysis for Statisticians. New York: Springer-Verlag; 1999. [Google Scholar]
- Logan J, Fowler JS, Volkow ND, et al. Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C–methuyl]-(-)-cocaine PET studies in human subjects. J Cereb blood Flow Metab. 1990;10:740–747. doi: 10.1038/jcbfm.1990.127. [DOI] [PubMed] [Google Scholar]
- Logan J. A review of graphical methods for tracer studies and strategies to reduce bias. Nucl Med Biol. 2003;30(8):833–844. doi: 10.1016/s0969-8051(03)00114-8. [DOI] [PubMed] [Google Scholar]
- Lundkvist C, Halldin C, Ginovart N, Nyberg S, Swahn CG, Carr AA, Brunner F, Farde L. [11C]MDL 100907, a radioligland for selective imaging of 5-HT(2A) receptors with positron emission tomography. Life Sci. 1996;58(10):187–192. doi: 10.1016/0024-3205(96)00013-6. Erratum in: Life Sci 58(25):379. [DOI] [PubMed] [Google Scholar]
- Marquardt DW. An algorithm for least-squares estimations of nonlinear parameters. J. Soc. Ind. Appl. Math. 1963;11:431–441. [Google Scholar]
- Mintun MA, Raichle ME, Kilbourn MR, Wooten GF, Welch MJ. A quantitative model for the in vivo assessment of drug binding sites with positron emission tomography. Ann Neurol. 1984;15:217–227. doi: 10.1002/ana.410150302. [DOI] [PubMed] [Google Scholar]
- Ogden RT. Estimation of kinetic parameters in graphical analysis of PET imaging data. Stat Med. 2003;22(22):3557–3568. doi: 10.1002/sim.1562. [DOI] [PubMed] [Google Scholar]
- Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab. 1983;3(1):1–7. doi: 10.1038/jcbfm.1983.1. [DOI] [PubMed] [Google Scholar]
- Patlak CS, Blasberg RG. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab. 1985;5:584–590. doi: 10.1038/jcbfm.1985.87. [DOI] [PubMed] [Google Scholar]
- Rahmim A, Zhou Y, Tang T. Direct 4D parametric image estimation in reversible tracer binding imaging. J Nucl Med. 2009;50:137P. [Google Scholar]
- Schmidt KC, Turkheimer FE. Kinetic modeling in positron emission tomography. Q J Nucl Med. 2002;46(1):70–85. Review. [PubMed] [Google Scholar]
- Slifstein M, Laruelle M. Effects of statistical noise on graphic analysis of PET neuroreceptor studies. J. Nucl. Med. 2000;41:2083–2088. [PubMed] [Google Scholar]
- Turkheimer FE, Hinz R, Cunningham VJ. On the undecidability among kinetic models: from model selection to model averaging. J Cereb blood Flow Metab. 2003;23:490–498. doi: 10.1097/01.WCB.0000050065.57184.BB. [DOI] [PubMed] [Google Scholar]
- Watabe H, Channing MA, Der MG, Adams HR, Jagoda E, Herscovitch P, Eckelman WC, Carson RE. Kinetic analysis of the 5-HT2A ligand [11C]MDL 100,907. J Cereb Blood Flow Metab. 2000;20(6):899–909. doi: 10.1097/00004647-200006000-00002. [DOI] [PubMed] [Google Scholar]
- Wong DF, Gjedde A, Wagner HN., Jr Quantification of neuroreceptors in living human brain. I. Irreversible binding of ligands. J Cereb Blood Flow Metab. 1986;6:137–146. doi: 10.1038/jcbfm.1986.27. [DOI] [PubMed] [Google Scholar]
- Wong DF, Yung B, Dannals RF, Shaya EK, Ravert HT, Chen CA, Chan B, Folio T, Scheffel U, Ricaurte GA, et al. In vivo imaging of baboon and human dopamine transporters by positron emission tomography using [11C]WIN 35,428. Synapse. 1993;15(2):130–142. doi: 10.1002/syn.890150205. [DOI] [PubMed] [Google Scholar]
- Yu DC, Huang SC, Barrio JR, Phelps ME. The assessment of the non-equilibrium effect in the 'Patlak analysis' of Fdopa PET studies. Phys Med Biol. 1995;40(7):1243–1254. doi: 10.1088/0031-9155/40/7/007. [DOI] [PubMed] [Google Scholar]
- Zhou Y, Endres CJ, Brasic JR, Huang SC, Wong DF. Linear regression with spatial constraint to generate parametric images of ligand-receptor dynamic PET studies with a simplified reference tissue model. Neuroimage. 2003;18(4):975–989. doi: 10.1016/s1053-8119(03)00017-x. [DOI] [PubMed] [Google Scholar]
- Zhou Y, Endres CJ, Brasic JR, Dogan AS, Hilton J, Singer HS, Wong DF. Quantification of cerebral serotonin binding in normal controls and subjects with Tourette's syndrome using [11C]MDL 100,907 and (+)[11C]McN 5652 dynamic PET with parametric. Neuroimage. 2004;22 Suppl 2:T98. [Google Scholar]
- Zhou Y, Resnick SM, Ye W, Fan H, Holt DP, Klunk WE, Mathis CA, Dannals R, Wong DF. Using a reference tissue model with spatial constraint to quantify [11C]Pittsburgh compound B PET for early diagnosis of Alzheimer’s disease. Neuroimage. 2007;36(2):291–305. doi: 10.1016/j.neuroimage.2007.03.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhou Y, Resnick S, Ye W, Sojkova J, Wong DF. Using a consistent graphical analysis method to improve the voxel-wise quantification of [11C]PIB dynamic PET. J Nucl Med. 2009a;50:31P. [Google Scholar]
- Zhou Y, Ye W, Brasić JR, Crabb AH, Hilton J, Wong DF. A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies. Neuroimage. 2009b;44(3):661–670. doi: 10.1016/j.neuroimage.2008.09.021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhou Y, Ye W, Brasic JR, Wong DF. Evaluation of a consistent bi-graphical plot to quantify relative slow tracer kinetics in ligand-receptor dynamic PET studies. J Nucl Med. 2009c;50:31P. [Google Scholar]