Skip to main content
Antioxidants & Redox Signaling logoLink to Antioxidants & Redox Signaling
editorial
. 2010 Mar 15;12(6):683–691. doi: 10.1089/ars.2009.2519

The Physics of Oxygen Delivery: Facts and Controversies

Amy G Tsai 1,, Pedro Cabrales 2, Marcos Intaglietta 1
PMCID: PMC2834451  PMID: 19757988

Abstract

At the microvascular level, the radial oxygen gradient is greater in arterioles than in any other vascular segment and thus drives the oxygen from the blood (high concentration, source) into the perivascular tissue (low concentration, sink). Thus, arterioles appear to be the main suppliers of oxygen to the tissue, in contrast to the capillaries, where the oxygen gradient is only a few millimeters of mercury. However, longitudinal oxygen loss from arteriolar blood is higher than can be solely accounted for by diffusion. This discrepancy becomes evident when determining how oxygen is distributed in the microvascular network, an approach that requires confirmation of the data in terms of mass balance and thermodynamic considerations. A fundamental difficulty is that measuring tissue Po2 is complicated by methods, exposure of tissue, interpretation, and resolution. The literature reports mean tissue Po2 as low as 5 and up to 50 mm Hg. This large variability is due to the differences in techniques, species, tissue, handling, and interpretation of signals used to resolve Po2 levels. Improving measurement accuracy and physiological interpretation of the emerging Po2 data is ongoing. We present an analysis of our current understanding of how tissue is supplied by oxygen at the microscopic level in terms of present results from laboratories using differing methods. Antioxid. Redox Signal. 12, 683–691.


Our understanding of how oxygen is transported from blood into the tissues is based on the measurement of the oxygen partial pressure in different tissue structures. This is a multiscale analysis that ranges from overall systemic mass balances to details of how oxygen is distributed at the microscopic level, at the scale of blood capillaries and the mitochondria. Whereas oxygen management at the systemic level is fairly well understood, oxygen regulation on the microscopic scale continues to undergo conceptual challenges as new techniques and measurement procedures become available. Older and newer techniques remain technically complex, to the extent that they are seldom available at a single laboratory, thus making it difficult to compare methods or even to perform ancillary experiments such as mass-balance analyses that would give confidence to the accuracy and relevance of results.

Biophysics of Oxygen Distribution in the Tissues

Determining the optimal steady-state oxygen environment for a given cell type remains a principal question. Before actual measurements of tissue oxygen distribution, tissue cells were thought to be exposed and adapted to significantly different Po2 environments, depending on their location. This is because the microcirculation has longitudinal oxygen-concentration gradients that convert arterial blood into venular and venous blood. In this scenario, cells near arterioles would have greater availability of oxygen in comparison to cells in the proximity of venules.

A significant variability in tissue Po2 could be related to the presence of cells with differing capacities and adaptabilities to extended exposure to different oxygen tensions. For example, the endothelium lining the microvasculature could have a different function in arterioles, capillaries, and venules and therefore require different levels of oxygen exposure. Alternatively, tissues during normal conditions could present a relatively uniform and narrowly regulated profile, regardless of their proximity to specific microvascular structures. In this context, an important function of oxygen transport to tissues at rest by capillaries may be that of equilibrating tissue Po2 differences by transporting oxygen between regions with high and low Po2 values. These considerations lead to the basic question of what is the variability of tissue Po2 under normal conditions.

Measurement of tissue Po2

Polarographic Clark needle electrodes were the first method used to measure tissue Po2. Whalen et al. (72) used this technique, providing early information on the oxygen distribution in the tissue. A multielectrode version of the polarographic electrode subjects the tissue to less trauma, but is able to assess only surface Po2. It has been used successfully to map surface tissue Po2 distributions (38). The next significant technical advancement in Po2 methodology was made by the group directed by Prof. David F. Wilson, who pioneered the oxygen phosphorescence quenching technique (67). This method requires the injection of a metallo-organic protein (palladium porphyrin) dye and is based on the quenching of excited phosphorescence by oxygen, providing Po2 measurements wherever the dye is present, independent of its concentration. Initially Po2 measurements were made in tissue microregions where the dye was injected intravenously (54, 59). Later, perivascular Po2 measurements were found to be possible because of the natural extravasation of the protein–dye complex (30). Then Wilson and co-workers (73, 74) developed a method by which the dye–protein complex is excited with light modulated at different frequencies, a technique that yields Po2 distribution in terms of continuous histograms of intra- and extravascular Po2, showing the existence of substantial portions of the tissue (skeletal muscle) with Po2 in the range of 100 to 140 mm Hg. The physiological implications of the resulting histograms are discussed by Tsai et al. (65).

Tissue exposure

The variability of tissue Po2 emerging from the use of different or the same measurement techniques can be also a function of the method used to isolate the tissue from the environment. The cremaster and cheek-pouch preparations of the rat or hamster are often used for microvascular studies of skeletal muscle and require the tissue to be exposed and irrigated with a salt solution equilibrated with 100% N2 or with 95% N2/5% O2 to maintain a pseudo-physiologic condition. Measurements with oxygen microelectrodes require continuous bathing of the tissue surface with the suffusing solution, which acts as an infinite sink or source of oxygen. This creates an artificial oxygen-boundary condition at the surface of the tissue, which will distort the tissue oxygen distribution. Studies with this type of tissue isolation have also been conducted on the brain surface (28).

Optical oxygen measurements can be made by covering the exposed tissue with a transparent barrier (e.g., polyvinyl film or glass), which adequately provides isolation from environmental influences. Polyvinyl film has been used to isolate the tissue under study in acute conditions associated with the hamster cheek pouch (3, 58), cremaster (29), and the mesentery (24) preparations. Window-chamber techniques, although limited to tissue folds, are probably optimal in preserving the “milieu interieur” because they are designed to be contiguous to the intact skin, and thus sealed and independent from the environment. This method establishes an impermeable boundary condition, allows the tissue adjacent to the barrier to evolve its own Po2, and provides a period of observation in the order of weeks. Window preparation was originally developed for the rabbit ear (46) and then implemented in rodents (1); it initially depended on the formation of scar tissue to fill the chamber. Reinhold (44) developed a dorsal skin-fold window chamber in the rat that allowed visualizing the microcirculation of a thin layer of preexisting tissue in the dorsal region, which includes a skin retractor muscle and subcutaneous tissue. This model was refined (39) and then adapted to hamsters (16), rats (55), and mice (34). A cranial window was developed to allow direct observation of the pial vasculature (35).

Internal consistency of the data

The uncertainties introduced by the method for exposing the tissue, the variability between tissue, differences in methods, and the intrinsic potential variability due to the location of the measurement site along the microvasculature are complicating factors, and this method should be calibrated against known or accepted standards. When this is not possible, it may still be possible to obtain independent checks on the data by carrying out additional measurements that test the internal consistency of the data, such as performing a mass-balance analysis in which the amount of oxygen arriving by convection must equal the amount of oxygen exiting by convection, diffusion, and consumption.

An example of the internal inconsistency of available information for skeletal muscle can easily be found with a quick perusal of the literature. Oxygen microelectrodes are the basis for a well-established method and source of information on tissue Po2 data; however, they are not exempt from contradictions. Whalen and co-workers (70, 71) reported that 75% of tissue Po2 values were between 0 and 5 mm Hg in guinea pig gracilis (70) and cat heart muscle (71), whereas measurements in the cat soleus muscle averaged 18.9 ± 1.8 mm Hg. Lash and Bohlen (33) reported values on the order of 30 mm Hg for rat spinotrapezius muscle. Whalen's low values may be due to anesthesia. In contrast, Wilson et al. (73) “ … conclude that the currently available data are consistent with mean oxygen pressures in normal skeletal muscle interstitium of 35–45 Torr and with there being negligible volumes with oxygen pressures <15 Torr.” The deconvolution method used by these investigators yielded a significant number of measurements beyond 100 mm Hg, above arterial blood Po2, and some even beyond atmospheric Po2.

The internal consistency of the data was analyzed by using information on intravascular measurements of the longitudinal arteriolar Po2 gradient to match the rate of oxygen exit with the diffusion flux from microvessels (43). This analysis showed that oxygen exit was greater than the diffusional flux by a factor of 10. Several studies were carried out to attempt to eliminate this factor of 10 discrepancy, which was summarized by Vadapalli et al. (66), but no conclusions were reached.

A mass-balance analysis between the rate of oxygen exit from arterioles and the diffusional rate of exit from these vessels used measurement of the perivascular tissue Po2 gradient in the rat mesentery preparation (62). The phosphorescence quenching technique was used to measure Po2, and blood flow was measured optically. It also showed that the cause for the large rate of outward diffusion was the steep gradients at the microvascular walls, an effect compatible with the hypothesis that the microvascular wall consumes a large quantity of oxygen. Similar conclusions were reached independently by Shibata and co-workers (4951) by using a different preparation. This study supports the results of Popel et al. (43) (i.e., oxygen exits the arterioles at a rate that is greater than that solely due to passive diffusion).

Microelectrode- or phosphorescence-based methods consume oxygen; therefore, it is critical to estimate the oxygen loss by the measuring technique. As of this writing, the only attempt to compare two techniques simultaneously was performed by Buerk et al. (6), who compared the phosphorescence-quenching and microelectrode methods in the tissue of the hamster dorsal-window chamber. Results show no difference between the two methods. This finding indicates that both techniques could be subject to the same errors due to oxygen consumption, and tissue Po2 in the unanesthetized condition is on the order of 22 mm Hg. This value also was obtained by using multi-wire surface electrodes in the same tissue (38). Other techniques have not been subjected to this kind of direct correlation.

Cabrales et al. (9) used mass balance to validate the dynamics of intra- and extravascular Po2 changes due to oxygen exit from mechanically occluded arterioles. The rate at which oxygen concentration decreased in the occluded arteriolar segments was compared with the diffusional flux determined from data on the Po2 gradient in the tissue with satisfactory results, within the limits of accuracy inherent to the techniques used.

Internal consistency of the data also was found in analyzing tissue and intracapillary oxygen transients from passage of single red blood cells (RBCs) in capillaries. The studies by Golub and Pittman (23) showed significant intracapillary Po2 transients as a result of the passage of RBCs in capillaries of the mesentery (23), to the extent that capillary blood Po2 was as high as 35 mm Hg when an RBC was present, and decreased to 10 mm Hg in the intra-RBC space (i.e., in the plasma between RBCs). Because plasma does not consume oxygen, if its Po2 decreases to 10 mm Hg, then this is because it equilibrates with the oxygen Po2 in the pericapillary tissue, following the plasma-to-tissue oxygen concentration gradient. This process requires that the tissue Po2 be lower than the plasma Po2 (i.e., 10 mm Hg). However, a substantial discrepancy appears in the value of mesenteric tissue Po2, because the same authors reported tissue Po2 in avascular areas of the mesentery to be consistently greater than 50 mm Hg (22). A recent study in the capillaries of the rat spinotrapezius muscle (2) yielded similar results, although the magnitude of the differences in Po2 due to RBC passage was not so pronounced.

Cabrales and Intaglietta (8) carried out a similar study in the capillaries of the hamster window-chamber model, exploring the possibility that the significant reduction of intra-RBC plasma was due to oxygen consumption of the phosphorescence-quenching technique. They reduced the excitation intensity and found that the Po2 difference between RBCs and intra-RBCs plasma became progressively lower and was eliminated if results were extrapolated to zero-intensity excitation light. Here the internal consistency of the data was explored by a simple and direct variation of the technique.

Data on human tissue Po2 is scarce because most clinical information is derived from photometric measurements that determine the oxygen saturation of hemoglobin. Oxygen partial pressure in the anterior tibial muscle was measured in sedentary healthy subjects with a microelectrode at the end of a 0.45-mm catheter, yielding a Po2 of 27.3 ± 12.1 mm Hg (57). A recent study using Clark electrodes found that Po2 in the abdominal subcutaneous tissue of lean healthy subjects was 55 ± 9 mm Hg (40).

Systematic exploration of tissue Po2 variability

Tissue Po2 during normal conditions was thought until recently to be in the range of 20 to 25 mm Hg. Recent clinical studies propose that this value may be as high as 50 mm Hg (73), a result supported by the measurements in human adipose tissue (40). However, these measurements in humans were made with Clark electrodes, which tend to yield higher values because they introduce a significant perturbation of the tissue microenvironment and sample an oxygen field that includes the contribution of microvessels in addition to the interstitium.

The lower limit for tissue Po2 is about 2 mm Hg, at which point the tissue metabolism switches from aerobic to anaerobic metabolism (45). Therefore, under normal resting conditions, an ample margin of safety exists to protect the tissue from anoxia; however, this is limited by the variability of tissue Po2. As an example, the Po2 variability measured with the phosphorescence-quenching technique in the tissue of the hamster dorsal-window-chamber preparation, in which the tissue is isolated from the environment with glass, is reported to have a standard deviation (σ) of about ± 4 mm Hg. Thus, in normal resting conditions, in which this tissue is supposed to average 22 mm Hg, cellular anoxia is at least 3σ distant from the mean, ensuring that fewer than 0.1% of the cells are at risk. At present, it not evident why tissue Po2 should be as high as 220 mm Hg in terms of the risk for tissue anoxia, and the rationale for tissue Po2 being in the range of 50 mm Hg is not apparent.

Extravascular Po2 heterogeneity could be an intrinsic consequence of the intravascular longitudinal Po2 gradient from arterioles to capillaries and venules. However, this source of variability is not demonstrated by results obtained from in vivo studies (64). This is partially due to the longitudinal microvascular Po2 gradient tendency to reverse in venules because of anatomic pairing with countercurrent flowing arterioles, allowing oxygen diffusion from arterioles to venules, and convective shunts that transport oxygen from arterioles directly to venules, thus bypassing transit through capillaries (14, 56). Comparatively large oxygen gradients at the arteriolar and venular walls may be a mechanism whereby the higher blood Po2 is reduced to a perivascular Po2 level in proximity of the average interstitial Po2. Therefore, the presence of a “U”-shaped intravascular longitudinal oxygen gradient (spanning arterioles and venules) and the presence of perivascular gradients could be the reason for the Po2 being uniformly distributed in the tissue and not significantly influenced by the proximity to arterioles and venules.

The Distribution of Tissue Po2

A systematic survey was made of the variability of tissue Po2 in the hamster dorsal-window-chamber model by using the phosphorescence-quenching technique (65). Tissue Po2 measurements were performed according to two methods: (a) a “random” protocol, in which measurements were made along five vertical and three horizontal axes, the microscopic field being advanced in approximately 150-μm steps along each axis to a location where the Po2 was measured; and (b) a “focused” protocol in which tissue Po2 measurements were made in areas void of large feeding vessels and between capillaries. The random protocol includes intravascular, perivascular, or interstitial tissue measurements and combinations of each, whereas the focused protocol interrogates intercapillary tissue.

Results for the random protocol were that average tissue Po2 was 25.1 ± 8.9 mm Hg, ranging from 63.1 to 5.5 mm Hg. As expected, the focused protocol yielded a lower and narrower tissue Po2 that averaged 20.2 ± 7.7 mm Hg, with 36.8 and 14.8 mm Hg maxima and minima, respectively. The low values in the random protocol corresponded to the oxygen levels measured in terminal lymphatics (24).

Nolte et al. (38) used the multiwire polarographic electrode to survey tissue Po2 distribution in the open hamster dorsal window chamber. These data are presented in Fig. 1, together with the data from Tsai et al., for the random protocol previously discussed. The same figure shows the data reported by Wilson et al. (74) for skeletal muscle.

FIG. 1.

FIG. 1.

Tissue Po2 obtained from three different techniques illustrates the variability of findings and how difficult it is to compare available data. The histograms are obtained from the hamster dorsal-window-chamber model. Nolte et al. (38) obtained the Po2 distribution by using a multiwire polarographic electrode array placed on top of the tissue suffused with a heated buffer solution (white bars). Tsai et al. (56), by using the sealed window chamber and a random discrete sampling of the tissue, constructed a histogram (black bars) with a slightly higher peak with the shift of the histogram to the left, as compared with one obtained with the electrode array. The technique used by Wilson et al. (74) resolves the emission signal and produces a curve (dotted line) representing the volume fraction of tissue (right y-axis) as a function of Po2. In this representation, the high values, which reach 140 mm Hg, and lower values (−10 mm Hg) are not shown. However, an interpretation of this curve is to equate the peak (∼50 mm Hg) as the average tissue Po2 within the hamster check pouch. A study that provides data in the form of tissue Po2 histograms is that of Nolte et al., who used the multiwire polarographic electrode to survey tissue Po2 distribution in the open hamster dorsal-window chamber (38).

The data of Wilson et al. (74) presented histograms of tissue fractions with Po2 showing a continuous variability from near-zero values to arterial values as high as 140 mm Hg, with 20% of the tissue volume being in the range of 100 to 140 mm Hg. It should be noted that the maximum Po2 achieved by arterial blood in the lung is about 100 mm Hg. The existence of a longitudinal gradient of Po2 is a well-established feature of Po2 distribution in the vasculature (64), and it is impossible for blood Po2 to exceed the Po2 of blood in the lungs. Boegehold and Johnson (4) recorded, by using Whalen microelectrodes in 55-μm diameter arterioles of the cat sartorius muscle, a periarteriolar Po2 of 52.1 ± 3.1 mm Hg [standard error of the mean (SEM)] with tissue Po2 of 22.8 ± 3.3 mm Hg. Smith et al. (53, 54), by using the oxygen phosphorescence-quenching technique, measured a Po2 of 37 ± 2 mm Hg in similar-sized arterioles in rat spinotrapezius muscle and 31 ± 3 mm Hg in venules. Therefore, periarteriolar tissue Po2 has a very a narrow range that prevents over oxygenation of tissue.

Wilson et al. (73) used the signal-processing technique, Maximal Entropy Analysis, to resolve their measurements of light emission. Their interpretation of their results is that the broadening of the Po2 histogram leading to the inclusion of a significant population of extreme nonphysiologic values is “intrinsic to the technique” and that “ … the uncertainty in the determination of phosphorescence life time increases with decreasing S/N (signal to noise ratio).” They truncate the data at 140 mm Hg; however, it is possible and likely that the cause for the appearance of very high Po2 values as a consequence of their method to resolve the Po2 from the emission by using variable frequencies may affect the Po2 distribution as a whole, including the low values of the distribution. They recently reported similar results for tumors, tissues that tend to be underoxygenated (73).

In conclusion, little agreement exists between results on tissue Po2 distribution, and historically, a trend appears continuously to increase the estimate of the magnitude of tissue Po2, as we compare results by Whalen et al. (7072) with our data and that generated from studies in Professors Pittman's and Wilson's laboratories.

Noninvasive Indirect Methods Used to Assess Tissue Oxygenation

No direct methods are used to measure tissue oxygen levels. In the clinic, assessment of oxygenation is made by monitoring intravascular hemoglobin oxygen saturation (HbO2Sat) based on measurements of light absorption, a method specific to intravascular oxygenation that is only a surrogate measurement for perivascular and interstitial tissue Po2 distribution. The technique determines percentage hemoglobin oxygen saturation by measuring the light absorbed at a reference wavelength and the isobestic wavelength of oxygen and deoxyhemoglobin (15). Optical monitoring of oxy- and deoxyhemoglobin by near-infrared spectroscopy (NIRS) was original developed as a noninvasive optical technique for bedside monitoring of oxygenation (52), and in combination analytical methods resolves both blood flow and HbO2Sat in vascular beds (68). It is most accurate when light absorption by the tissue is minimized, as with transillumination of thin tissues. The problem with these techniques is the transmission of light through tissue, which depends on absorption and scattering effects. Scattering due to flowing RBCs and tissues requires multiwavelength analysis to resolve RBC density to measure saturation accurately. Markers in combination with red-light optical tomography (18) are used to tag hypoxic zones within the tissue in tumors treated with photodynamic therapy (7); however, they differentiate only anoxia from normoxia. Raman spectroscopy, implemented to measure microvascular HbO2Sat (60), does not provide an absolute definition for the zero Po2 baseline.

Tissue Po2 and How Oxygen Exits the Circulation

The classic concept explaining oxygen exit from the circulation is that it is driven by the oxygen-concentration gradient between blood and tissue, moving from the source to the sink (31). The only modification to this concept has been that the major oxygen-concentration gradient has been found at the blood–tissue interface in the arterioles but not in capillaries (12). Thus the mirror-image analogy whereby oxygen is absorbed in lung capillaries and delivered in the tissue capillaries does not appear to hold for many tissues because lung capillaries present well-defined large Po2 gradients, whereas tissue capillaries could be in oxygen near-equilibrium.

The literature in general supports capillaries being the principal suppliers of oxygen to the tissues; however, the balance between arterioles and capillaries being the suppliers of oxygen to the tissues varies from organ to organ, and with the activity level of the tissue involved. Functional studies of skeletal muscle also show that muscle capillarity and aerobic capacity are related (42). An approach to determine the relative contribution of arterioles versus capillaries is that of comparing their change of oxygen saturation between the precapillary and the capillary compartments. Tsai et al. (64) made a summary of the available data and showed that the reduction of oxygen saturation is greater in the capillaries of the myocardium, the exercising gracilis muscle, and the rat cortex. Most other tissues show a trend for a greater decrease in oxygen saturation in the precapillary circulation. One of the tissues studied in greatest detail is the hamster check pouch (under anesthesia) (10) and the unanesthetized hamster window chamber (26). In these tissues, the precapillary oxygen exit is 3.0 and 2.5 times the capillary change in oxygen saturation, respectively.

Studies into the mechanisms of oxygen transportation from blood into the tissue show that a significant amount of oxygen is delivered by the arteriolar circulation, an effect that determines the presence of longitudinal microvascular oxygen gradients. This is documented in a variety of tissues (64). This phenomenon requires the existence of a corresponding radial oxygen intraluminal/extraluminal oxygen gradient (19, 61, 64), which is the driving force that determines oxygen exit from blood vessels. It is usually assumed that these oxygen-concentration gradients are determinants of the process of diffusion; however, other mechanisms not fully dependent on the random, thermally driven molecular/atomic momentum exchange that causes diffusion are conceptually possible, provided that at steady state and in the absence of external energy sources, the transfer of matter does not violate thermodynamic principles.

Mass-balance considerations indicate that the longitudinal gradient of blood Po2 in the microcirculation must be matched by a corresponding rate of oxygen exit through the vessel wall, because blood is not a significant oxygen-consuming compartment. Most attempts to establish this mass balance show that the oxygen exit rate is, in general, significantly higher than accounted for by estimating the oxygen diffusion rate across the vessel walls (43).

Tsai et al. (62), using the oxygen phosphorescence-quenching technique, found that longitudinal and radial fluxes did indeed balance, because steep oxygen-concentration gradients exist across the vessel wall. To recapitulate, if no oxygen-concentration gradients exist at the vessel wall, in the presence of a finite oxygen flux, a virtually infinite diffusional conductivity through the vessel wall must exist. Such a possibility is not readily apparent. A significant amount of oxygen is delivered to the tissue via the arterioles. The arteriolar wall is composed of endothelium and smooth muscle, which also require oxygen to sustain their metabolism. The literature and many experimental investigations show that these cells have a resistance to oxygen diffusion that is not different from that of other tissues. These rudimentary factors require the presence of commensurate oxygen-concentration gradients at the arteriolar walls.

Carvalho and Pittman (10) reported that the transmural Po2 difference (i.e., across the arteriolar vessel wall) in 45.8 ± 5.4-μm diameter arterioles in the hamster check pouch, is 1.0 ± 2.7 (SEM, n = 5) mm Hg, or 1.0 ± 6.7 (SD) mm Hg, and a significant oxygen loss is found from arterioles, similar to that found by other investigators. These data probably are un-interpretable in terms of conventional physical principles, because the small transmural Po2 gradient and large standard deviation suggest that either (a) measurement errors introduce excessive noise, and the arterioles are in oxygen equilibrium with the tissue, precluding the existence of a longitudinal oxygen gradient; or b) the technique is accurate and shows that a substantial number of arterioles are oxygenated by the tissue (i.e., have a negative Po2 gradient). A combination of the two possibilities is likely, and no conclusion can be drawn from this result unless a local mass balance of oxygen fluxes is made.

Is Nondiffusion-Transported Oxygen Possible?

The results obtained by the studies of Carvalho and Pittman and other studies suggest that mechanisms other than diffusion transport oxygen across the vessel walls. The endothelium of the microvascular wall may present a tunneling-like process, which, even in the presence of weak oxygen concentration gradients, may transfer large amounts of oxygen. It is generally assumed that the diffusion resistance across the lipid bilayer and cell cytosol does not exceed the diffusion resistance of a water layer of the same thickness (17, 36). However, small uncharged molecules homologous to oxygen, such as H2O, CO2, CO, and NH4, penetrate the cell membranes through pores (channels) made of membrane proteins. These molecules are transported through membranes with the aid of aquaporin and, possibly, the band 3 protein (69). Moreover, it was demonstrated experimentally that oxygen can also penetrate through these channels. Mechanistically, this is due to the ability of bulky organic radicals to form microcavities in the lipid environment, in which oxygen mobility and concentration can be significantly greater than in the unmodified lipid bilayer (27).

Therefore, mechanisms exist that could explain a high diffusivity of oxygen across the cell membrane. A problem arises with this concept because, after oxygen transverses the cell membrane, it has to diffuse through the cytosol. This is a fluid environment that presumably lacks the high-diffusivity channels for gas molecules. Furthermore, this medium has a viscosity greater than that of water, with direct consequences on the magnitude of the diffusion constant, which is inversely proportional to the viscosity of the medium in which it takes place. Therefore, it can be expected that oxygen mobilities in the cytosol media limit oxygen diffusion across the vessel wall as well.

A fundamental question to be resolved is to determine the oxygen demand of arterioles in vivo to be able to choose between a simple diffusion-process oxygen exit from arterioles and one combined with high oxygen consumption. At present, the basic approach to resolve this is improving the spatial-resolution measurements of oxygen concentration.

Oxygen Consumption by Blood Vessels, an Alternate Hypothesis

The endothelium is one of the most active biochemical cell systems of the mammalian organism, producing metabolites that regulate many critical homeostatic mechanisms. The activity of the endothelium addresses the major regulatory system, such as the control of inflammation, maintenance of anticoagulatory function, control of fluid exchange, sensing of mechanical events at its surfaces (mechanotransduction), and production of metabolites in response to varying oxygen supply and local demand.

Estimates of oxygen consumption of the vasculature

The respiration of vascular tissue, with data mostly derived from isolated vessel segments, slices, or rings, and focused on the respiration rate of smooth muscle, with no particular attention to the status of the endothelium. The majority of reported values in a review by Paul (41) were between 1.1 and 4.5 × 10−3 ml O2/min/g or three orders of magnitude smaller than measurements related to the respiration of arterioles in whole organs with intact endothelium.

Organ studies

Curtis et al. (11) used a detergent to strip the endothelium of the blood vessels of the dog hindlimb and found that the oxygen consumption of the preparation decreased by 35% (11). These authors explored alternatives to explain the decreased oxygen consumption, including interference with fluid balance, edema formation, and plugging of capillaries, reducing functional capillary density. Assuming that the endothelium is of the order of 0.1% of the tissue mass, we may conclude that the oxygen consumption of this tissue in situ is about 350 times that of the remainder of the tissue.

Ye et al. (75) perfused the rat hindlimb, kidney, intestine, and the mesentery at constant flow and found that vasoconstriction induced by the administration of noradrenaline or vasopressin significantly increases oxygen consumption by 75% on constriction. Vasoconstriction per se reduces functional capillary density and tissue perfusion (20); therefore, it is not likely that the increased oxygen consumption was due to increased tissue perfusion, as was subsequently proposed (9). Marshall and Davies (37) also found that hindlimb oxygen consumption of the animals breathing normal air, after being adapted to chronic hypoxia, increased by 1.53 ml O2/min/g arteriole.

Microscopic Methods to Determine Oxygen Consumption of the Endothelium

With the exception of the studies by Bruttig and Joyner (5) and Kuehl et al. (32), the literature reports that oxygen consumption of the endothelial cells is about two orders of magnitude lower than that shown by the in vivo studies.

The consumption of oxygen of the vessel wall (endothelium), deduced from the work of Tsai et al. (62), is 4.5 ml O2/min/cm tissue. From the data of Duling et al. (13), arterioles of similar dimension (22 μm diameter) have an oxygen consumption of 0.1 ml O2/min/cm. The results of Santilli et al. (47) for the rabbit aorta yield the value of 1.6 ml O2/min/g tissue.

Sharan et al. (48), by using oxygen electrodes on pial arterioles, reported oxygen gradients of 1.17 ± 0.06 mm Hg/μm, which was reduced to 0.68 ± 0.04 mm Hg/μm when the vessels were dilated. This finding is in accordance with those of several of our studies using the phosphorescence-quenching technique, which shows that vasodilatation reduces the oxygen gradient (25), and vice versa (20). Shibata et al. (50) also found similar correlations between changes in oxygen-consumption rate as a function of vasodilation and vasoconstriction of arterioles in the rat cremaster muscles by using the phosphorescence-quenching technique. The studies of Sharan et al. (48) and Tsai et al. (62) appear to yield similar results. Wall thickness is not reported, and all oxygen measurements used to construct a profile are carried out at 10-μm intervals. Thus, the uncertainty due to the catchment volume of the electrode may lead to gradients at the vessel wall that may be somewhat greater than reported. However, it is unfortunately not possible to check the internal consistency of the data by an independent calculation or measurement.

Lymphatic and Tissue Oxygen Distributions

Terminal lymphatic fluid is the compartment farthest removed from the oxygen supply, and therefore would present the lowest Po2 in the tissue due to oxygen consumption by the tissue and the lymphatic vessel wall. Lymphatic Po2 distribution was measured in the hamster dorsal-window-chamber model (24). Tissue Po2 averaged 24.6 ± 2.7 mm Hg. Lymphatic fluid Po2 in small and collecting vessels was 18.4 ± 2.6 and 18.0 ± 2.4 mm Hg, respectively. The significant difference between tissue and intralymphatic Po2 was due in part to the presence of an oxygen gradient across the lymphatic wall, which was 3.7 ± 1.3 and 6.0 ± 1.2 mm Hg for terminal and collecting lymphatics, respectively. This oxygen gradient was assumed to be due to the oxygen consumption by cellular components of the lymphatic wall. Thus, the increased vessel-wall gradient found in collecting lymphatics was reconciled with the findings that these microlymphatic vessels tend to be contiguous to arterioles, whereas the terminal lymphatics are dispersed in the tissue. These findings indicate that terminal lymphatics have the lowest Po2 in the tissue and differ from the concept that venules have the lowest oxygen tension.

Clinical Implications of Tissue Oxygen Distribution

The conceptualization that tissue is permeated by oxygen at an approximately constant Po2 level leads to the conclusion that in normal conditions, the tissue is not exposed to anoxia. However, the existence of this intrinsic variability associated with decreased oxygen delivery, and therefore tissue Po2, increases the probability of the incidence of ischemic regions. What can be done to reduce this risk and the related damage? When does this risk start? How does it progress? When does it become lethal? These questions cannot be fully answered without understanding how tissue Po2 is managed locally, and how these effects are related to clinically measured tissue Po2. Clinical methods for measuring “tissue Po2” measure average microvascular blood-oxygen saturation. This global parameter, as previously discussed, is indirectly related to tissue Po2 and may be incorrect in conditions of resuscitation involving therapeutic approaches aimed at restoring blood pressure by vasoconstriction (19). At the other end of the spectrum, tissue Po2 is used in clinical scenarios as one of the indicators for deciding the level of amputation in patients with severe limb ischemia.

The most critical aspect of oxygen distribution in clinical conditions is when it becomes a relevant factor in deciding therapy, particularly the intensive therapy environment. Two parameters require critical evaluation: (a) the absolute level of tissue oxygen; and (b) the intrinsic variability of tissue oxygen at the prevalent level. Present clinical methods approximate the first, because they derive information only from intravascular conditions, but do not address the second feature. This is particularly relevant because evidence suggests that tissue-perfusion inhomogeneity can be addressed clinically with newly formulated plasma expanders (63).

Summary

Accurate determination of tissue Po2 is technically difficult because of problems in assessing the measurement site. Additionally, incongruent results from different methods are difficult to compare, leading to widely differing interpretations of how the Po2 is distributed in tissue. The question remains as to the actual value of tissue Po2. Laboratories analyzing oxygen transport, having made significant contributions beyond the analysis based on the Krogh cylinder, are uncovering different, nonexclusive possibilities of how oxygen is transported from blood through the vessel wall into the tissue. This review highlights the limitations to our understanding of oxygen transport to tissue. Many questions that remain to be explored, particularly in terms of instrumentation, and mathematical modeling of oxygen transport (21). An understanding of the meaning of the tissue Po2 measurement is needed to improve diagnosis and treatment in the clinical setting.

Acknowledgments

This study was supported in part by the USPHS R24-HL 064395, R01-HL 062318, R01-HL 062354, R01-HL 076182, and R01-071064.

References

  • 1.Algire GH. An adaptation of the transparent chamber technique to the mouse. J Nat Cancer Inst. 1943;4:1–11. [PubMed] [Google Scholar]
  • 2.Barker MC. Golub AS. Pittman RN. Erythrocyte-associated transients in capillary Po2: an isovolemic hemodilution study in the rat spinotrapezius muscle. Am J Physiol Heart Circ Physiol. 2007;292:H2540–H2549. doi: 10.1152/ajpheart.00915.2006. [DOI] [PubMed] [Google Scholar]
  • 3.Bertuglia S. Giusti A. Microvascular oxygenation and oxidative stress during postischemic reperfusion: Po2, ROS, and NO during reperfusion. Adv Exp Med Biol. 2005;566:23–29. doi: 10.1007/0-387-26206-7_4. [DOI] [PubMed] [Google Scholar]
  • 4.Boegehold MA. Johnson PC. Periarteriolar and tissue pO2 during sympathetic escape in skeletal muscle. Am J Physiol. 1988;254:H929–H936. doi: 10.1152/ajpheart.1988.254.5.H929. [DOI] [PubMed] [Google Scholar]
  • 5.Bruttig SP. Joyner WL. Metabolic characteristics of cells cultured from umbilical blood vessels: comparison with 3T3 fibroblasts. J Cell Physiol. 1983;116:173–180. doi: 10.1002/jcp.1041160208. [DOI] [PubMed] [Google Scholar]
  • 6.Buerk DG. Tsai AG. Intaglietta M. Johnson PC. Comparing tissue pO2 measurements by recessed microelectrode and phosphorescence quenching. Adv Exp Med Biol. 1998;454:367–374. doi: 10.1007/978-1-4615-4863-8_44. [DOI] [PubMed] [Google Scholar]
  • 7.Busch TM. Local physiological changes during photodynamic therapy. Lasers Surg Med. 2006;38:494–499. doi: 10.1002/lsm.20355. [DOI] [PubMed] [Google Scholar]
  • 8.Cabrales P. Intaglietta M. Time-dependant oxygen partial pressure in capillaries and tissue in the hamster window chamber model. Antioxid Redox Signal. 2007;9:845–853. doi: 10.1089/ars.2007.1584. [DOI] [PubMed] [Google Scholar]
  • 9.Cabrales P. Tsai AG. Johnson PC. Intaglietta M. Oxygen release from arterioles with normal flow and no-flow conditions. J Appl Physiol. 2006;100:1569–1576. doi: 10.1152/japplphysiol.00762.2005. [DOI] [PubMed] [Google Scholar]
  • 10.Carvalho H. Pittman RN. Longitudinal and radial gradients of PO(2) in the hamster cheek pouch microcirculation. Microcirculation. 2008;15:215–224. doi: 10.1080/10739680701616175. [DOI] [PubMed] [Google Scholar]
  • 11.Curtis SE. Vallet B. Winn MJ. Caufield JB. King CE. Chapler CK. Cain SM. Role of vascular endothelium in O2 extraction during progressive ischemia in canine skeletal muscle. J Appl Physiol. 1995;79:1351–1360. doi: 10.1152/jappl.1995.79.4.1351. [DOI] [PubMed] [Google Scholar]
  • 12.Duling BR. Berne RM. Longitudinal gradients in periarteriolar oxygen tension: a possible mechanism for the participation of oxygen in the local regulation of blood flow. Circ Res. 1970;27:669–678. doi: 10.1161/01.res.27.5.669. [DOI] [PubMed] [Google Scholar]
  • 13.Duling BR. Kuschinsky W. Wahl M. Measurement of perivascular pO2 in the vicinity of pial vessels in the cat. Pflügers Arch. 1979;383:29–34. doi: 10.1007/BF00584471. [DOI] [PubMed] [Google Scholar]
  • 14.Ellsworth ML. Pittman RN. Arterioles supply oxygen to capillaries by diffusion as well as by convection. Am J Physiol. 1990;258:H1240–H1243. doi: 10.1152/ajpheart.1990.258.4.H1240. [DOI] [PubMed] [Google Scholar]
  • 15.Ellsworth ML. Pittman RN. Ellis CG. Measurement of hemoglobin oxygen saturation in capillaries. Am J Physiol. 1987;252:H1031–H1040. doi: 10.1152/ajpheart.1987.252.5.H1031. [DOI] [PubMed] [Google Scholar]
  • 16.Endrich B. Asaishi K. Götz A. Messmer K. Technical report: a new chamber technique for microvascular studies in unanaesthetized hamsters. Res Exp Med. 1980;177:125–134. doi: 10.1007/BF01851841. [DOI] [PubMed] [Google Scholar]
  • 17.Fischkoff S. Vanderkooi JM. Oxygen diffusion in biological and artificial membranes determined by the fluorochrome pyrene. J Gen Physiol. 1975;65:663–676. doi: 10.1085/jgp.65.5.663. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Franceschini MA. Joseph DK. Huppert TJ. Diamond SG. Boas DA. Diffuse optical imaging of the whole head. J Biomed Opt. 2006;11:054007. doi: 10.1117/1.2363365. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Friesenecker B. Does the vessel wall partition oxygen away from the tissue? Antioxid Redox Signal. 2007;9:985–989. doi: 10.1089/ars.2007.1616. [DOI] [PubMed] [Google Scholar]
  • 20.Friesenecker B. Tsai AG. Dunser MW. Mayr AJ. Martini J. Knotzer H. Hasibeder W. Intaglietta M. Oxygen distribution in microcirculation after arginine vasopressin-induced arteriolar vasoconstriction. Am J Physiol Heart Circ Physiol. 2004;287:H1792–H1800. doi: 10.1152/ajpheart.00283.2004. [DOI] [PubMed] [Google Scholar]
  • 21.Goldman D. Theoretical models of microvascular oxygen transport to tissue. Microcirculation. 2008;15:795–811. doi: 10.1080/10739680801938289. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Golub AS. Barker MC. Pittman RN. Po2 profiles near arterioles and tissue oxygen consumption in rat mesentery. Am J Physiol Heart Circ Physiol. 2007;293:H1097–H1106. doi: 10.1152/ajpheart.00077.2007. [DOI] [PubMed] [Google Scholar]
  • 23.Golub AS. Pittman RN. Erythrocyte-associated transients in Po2 revealed in capillaries of rat mesentery. Am J Physiol Heart Circ Physiol. 2005;288:H2735–H2743. doi: 10.1152/ajpheart.00711.2004. [DOI] [PubMed] [Google Scholar]
  • 24.Hangai-Hoger N. Cabrales P. Briceno JC. Tsai AG. Intaglietta M. Microlymphatic and tissue oxygen tension in the rat mesentery. Am J Physiol Heart Circ Physiol. 2004;286:H878–H883. doi: 10.1152/ajpheart.00913.2003. [DOI] [PubMed] [Google Scholar]
  • 25.Hangai-Hoger N. Tsai AG. Friesenecker B. Cabrales P. Intaglietta M. Microvascular oxygen delivery and consumption following treatment with verapamil. Am J Physiol Heart Circ Physiol. 2005;288:H1515–H1520. doi: 10.1152/ajpheart.00955.2004. [DOI] [PubMed] [Google Scholar]
  • 26.Intaglietta M. Johnson PC. Winslow RM. Microvascular and tissue oxygen distribution. Cardiovasc Res. 1996;32:632–643. [PubMed] [Google Scholar]
  • 27.Ivanov II. Loktyushkin AV. Gus'kova RA. Vasil'ev NS. Fedorov GE. Rubin AB. Oxygen channels of erythrocyte membrane. Dokl Biochem Biophys. 2007;414:137–140. doi: 10.1134/s160767290703012x. [DOI] [PubMed] [Google Scholar]
  • 28.Ivanov KP. Derry AN. Vovenko EP. Samoilov MO. Semionov DG. Direct measurements of oxygen tension at the surface of arterioles, capillaries, and venules. Pflugers Arch. 1982;393:118–120. doi: 10.1007/BF00582403. [DOI] [PubMed] [Google Scholar]
  • 29.Johnson PC. Vandegriff K. Tsai AG. Intaglietta M. Effect of acute hypoxia on microcirculatory and tissue oxygen levels in rat cremaster muscle. J Appl Physiol. 2005;98:1177–1184. doi: 10.1152/japplphysiol.00591.2004. [DOI] [PubMed] [Google Scholar]
  • 30.Kerger H Torres. Filho IP. Rivas M. Winslow RM. Intaglietta M. Systemic and subcutaneous microvascular oxygen tension in conscious Syrian golden hamsters. Am J Physiol. 1995;267:H802–H810. doi: 10.1152/ajpheart.1995.268.2.H802. [DOI] [PubMed] [Google Scholar]
  • 31.Krogh A. The number and distribution of capillaries in muscle with the calculation of the oxygen pressure necessary for supplying the tissue. J Physiol. 1918;52:409–515. doi: 10.1113/jphysiol.1919.sp001839. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Kuehl KS. Bruttig SP. Singer DV. Rubio R. Berne RM. Growth of aortic vascular smooth muscle cells in lowered oxygen tension. Cell Tissue Res. 1981;216:591–602. doi: 10.1007/BF00238654. [DOI] [PubMed] [Google Scholar]
  • 33.Lash JM. Bohlen HG. Perivascular and tissue pO2 in contracting rat spinotrapezius muscle. Am J Physiol. 1987;252:H1192–H1202. doi: 10.1152/ajpheart.1987.252.6.H1192. [DOI] [PubMed] [Google Scholar]
  • 34.Leunig M. Yuan F. Menger MD. Boucher Y. Goetz AE. Messmer K. Jain RK. Angiogenesis, microvascular architecture, microhemodyanmics and interstitial fluid pressure during early growth of human adenocarcinoma LS174T in SCID mice. Cancer Res. 1992;52:6553–6560. [PubMed] [Google Scholar]
  • 35.Levasseur JE. Wei EP. Raper EJ. Kontos HA. Patterson JL., Jr Detailed description of a cranial window technique for acute and chronic experiments. Stroke. 1975;6:308–317. doi: 10.1161/01.str.6.3.308. [DOI] [PubMed] [Google Scholar]
  • 36.Ligeza A. Tikhonov AN. Hyde JS. Subczynski WK. Oxygen permeability of thylakoid membranes: electron paramagnetic resonance spin labeling study. Biochim Biophys Acta. 1998;1365:453–463. doi: 10.1016/s0005-2728(98)00098-x. [DOI] [PubMed] [Google Scholar]
  • 37.Marshall JM. Davies WR. The effects of acute and chronic systemic hypoxia on muscle oxygen supply and oxygen consumption. Exp Physiol. 1999;84:57–68. doi: 10.1111/j.1469-445x.1999.tb00072.x. [DOI] [PubMed] [Google Scholar]
  • 38.Nolte D. Steinhauser P. Pickelmann S. Berger S. Härtl R. Messmer K. Effects of diaspirin-cross-linked hemoglobin (DCLHb) on local tissue oxygen tension in striated skin muscle: an efficacy study in the hamster. J Lab Clin Med. 1997;130:328–338. doi: 10.1016/s0022-2143(97)90028-7. [DOI] [PubMed] [Google Scholar]
  • 39.Papenfuss HD. Gross JF. Intaglietta M. Treese FA. A transparent access chamber for the rat dorsal skin fold. Microvasc Res. 1979;18:311–318. doi: 10.1016/0026-2862(79)90039-6. [DOI] [PubMed] [Google Scholar]
  • 40.Pasarica M. Sereda OR. Redman LM. Albarado DC. Hymel DT. Roan LE. Rood JC. Burk DH. Smith SR. Reduced adipose tissue oxygenation in human obesity: evidence for rarefaction, macrophage chemotaxis, and inflammation without an angiogenic response. Diabetes. 2009;58:718–725. doi: 10.2337/db08-1098. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Paul RJ. Smooth muscle energetics and theories of cross-bridge regulation. Am J Physiol. 1990;258:C369–C375. doi: 10.1152/ajpcell.1990.258.2.C369. [DOI] [PubMed] [Google Scholar]
  • 42.Poole DC. Mathieu-Costello O. Relationship between fiber capillarization and mitochondrial volume density in control and trained rat soleus and plantaris muscles. Microcirculation. 1996;3:175–186. doi: 10.3109/10739689609148286. [DOI] [PubMed] [Google Scholar]
  • 43.Popel AS. Pittman RN. Ellsworth ML. Rate of oxygen loss from arterioles is an order of magnitude higher than expected. Am J Physiol. 1988;256:H921–H924. doi: 10.1152/ajpheart.1989.256.3.H921. [DOI] [PubMed] [Google Scholar]
  • 44.Reinhold HS. Reoxygenation of tumors in “sandwich” chambers. Eur J Cancer. 1979;15:481–489. doi: 10.1016/0014-2964(79)90083-5. [DOI] [PubMed] [Google Scholar]
  • 45.Richmond KN. Shonat RD. Lynch RM. Johnson PC. Critical pO2 of skeletal muscle in vivo. Am J Physiol. 1999;277:H1831–H1840. doi: 10.1152/ajpheart.1999.277.5.H1831. [DOI] [PubMed] [Google Scholar]
  • 46.Sandison J. Observations on the growth of blood vessels as seen in the transparent chamber introduced in the rabbit ear. Am J Physiol. 1928;41:475–496. [Google Scholar]
  • 47.Santilli SM. Tretinyak AS. Lee ES. Transarterial wall gradients at the development site of an intra-arterial stent in the rabbit. Am J Physiol. 2000;279:H1518–H1525. doi: 10.1152/ajpheart.2000.279.4.H1518. [DOI] [PubMed] [Google Scholar]
  • 48.Sharan M. Vovenko EP. Vadapalli A. Popel AS. Pittman RN. Experimental and theoretical studies of oxygen gradients in rat pial microvessels. J Cereb Blood Flow Metab. 2008;28:1597–1604. doi: 10.1038/jcbfm.2008.51. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Shibata M. Ichioka S. Kaiya A. Estimating oxygen consumption rates of arteriolar walls under physiological conditions in rat skeletal muscle. Am J Physiol Heart Circ Physiol. 2005;289:H295–H300. doi: 10.1152/ajpheart.00830.2004. [DOI] [PubMed] [Google Scholar]
  • 50.Shibata M. Ichioka S. Kamiya A. Nitric oxide modulates oxygen consumption by arteriolar walls in rat skeletal muscle. Am J Physiol Heart Circ Physiol. 2005;289:H2673–H2679. doi: 10.1152/ajpheart.00420.2005. [DOI] [PubMed] [Google Scholar]
  • 51.Shibata M. Qin K. Ichioka S. Kamiya A. Vascular wall energetics in arterioles during nitric oxide-dependent and -independent vasodilation. J Appl Physiol. 2006;100:1793–1798. doi: 10.1152/japplphysiol.01632.2005. [DOI] [PubMed] [Google Scholar]
  • 52.Simonson SG. Piantadosi CA. Near-infrared spectroscopy: clinical applications. Crit Care Clin. 1996;12:1019–1029. doi: 10.1016/s0749-0704(05)70290-6. [DOI] [PubMed] [Google Scholar]
  • 53.Smith LM. Barbee RW. Ward KR. Pittman RN. Prolonged tissue Po2 reduction after contraction in spinotrapezius muscle of spontaneously hypertensive rats. Am J Physiol Heart Circ Physiol. 2004;287:H401–H407. doi: 10.1152/ajpheart.00980.2002. [DOI] [PubMed] [Google Scholar]
  • 54.Smith LM. Golub AS. Pittman RN. Interstitial PO(2) determination by phosphorescence quenching microscopy. Microcirculation. 2002;9:389–395. doi: 10.1038/sj.mn.7800147. [DOI] [PubMed] [Google Scholar]
  • 55.Smith TL. Osborne SW. Hutchins PM. Long-term micro- and macrocirculatory measurements in conscious rats. Microvasc Res. 1985;29:360–370. doi: 10.1016/0026-2862(85)90025-1. [DOI] [PubMed] [Google Scholar]
  • 56.Stein JC. Ellis CG. Ellsworth ML. Relationship between capillary and systemic venous pO2 during nonhypoxic and hypoxic ventilation. Am J Physiol. 1993;265:H537–H542. doi: 10.1152/ajpheart.1993.265.2.H537. [DOI] [PubMed] [Google Scholar]
  • 57.Sternitzky R. Kessler H. Mrowietz C. Pindur G. Jung F. Effect of naftidrofuryl on intramuscular partial oxygen pressure (pO2) prior to, during and after physical load on the treadmill in apparently healthy subjects. Clin Hemorheol Microcirc. 2002;27:185–191. [PubMed] [Google Scholar]
  • 58.Sullivan SM. Pittman RN. Hamster retractor muscle: a new preparation for intravital microscopy. Microvasc Res. 1982;23:329–335. doi: 10.1016/s0026-2862(82)80005-8. [DOI] [PubMed] [Google Scholar]
  • 59.Torres Filho IP. Intaglietta M. Microvessel pO2 measurements by phosphorescence decay method. Am J Physiol. 1993;265:H1434–H1438. doi: 10.1152/ajpheart.1993.265.4.H1434. [DOI] [PubMed] [Google Scholar]
  • 60.Torres Filho IP. Terner J. Pittman RN. Somera LG., 3rd Ward KR. Hemoglobin oxygen saturation measurements using resonance Raman intravital microscopy. Am J Physiol Heart Circ Physiol. 2005;289:H488–H495. doi: 10.1152/ajpheart.01171.2004. [DOI] [PubMed] [Google Scholar]
  • 61.Tsai AG. Friesenecker B. Cabrales P. Hangai-Hoger N. Intaglietta M. The vascular wall as a regulator of tissue oxygenation. Curr Opin Nephrol Hypertens. 2006;15:67–71. doi: 10.1097/01.mnh.0000196147.65330.a3. [DOI] [PubMed] [Google Scholar]
  • 62.Tsai AG. Friesenecker B. Mazzoni MC. Kerger H. Buerk DG. Johnson PC. Intaglietta M. Microvascular and tissue oxygen gradients in the rat mesentery. Proc Natl Acad Sci U S A. 1998;95:6590–6595. doi: 10.1073/pnas.95.12.6590. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63.Tsai AG. Intaglietta M. High viscosity plasma expanders: volume restitution fluids for lowering the transfusion trigger. Biorheology. 2001;38:229–237. [PubMed] [Google Scholar]
  • 64.Tsai AG. Johnson PC. Intaglietta M. Oxygen gradients in the microcirculation. Physiol Rev. 2003;83:933–963. doi: 10.1152/physrev.00034.2002. [DOI] [PubMed] [Google Scholar]
  • 65.Tsai AG. Johnson PC. Intaglietta M. Is the distribution of tissue PO(2) homogeneous? Antioxid Redox Signal. 2007;9:979–984. doi: 10.1089/ars.2007.1633. [DOI] [PubMed] [Google Scholar]
  • 66.Vadapalli A. Pittman RN. Popel AS. Estimating oxygen transport resistance of the microvascular wall. Am J Physiol. 2000;279:H657–H671. doi: 10.1152/ajpheart.2000.279.2.H657. [DOI] [PubMed] [Google Scholar]
  • 67.Vanderkooi JM. Maniara G. Green TJ. Wilson DF. An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence. J Biol Chem. 1987;262:5476–5482. [PubMed] [Google Scholar]
  • 68.Villringer A. Planck J. Hock C. Schleinkofer L. Dirnagl U. Near infrared spectroscopy (NIRS): a new tool to study hemodynamic changes during activation of brain function in human adults. Neurosci Lett. 1993;154:101–104. doi: 10.1016/0304-3940(93)90181-j. [DOI] [PubMed] [Google Scholar]
  • 69.Wang Y. Cohen J. Boron WF. Schulten K. Tajkhorshid E. Exploring gas permeability of cellular membranes and membrane channels with molecular dynamics. J Struct Biol. 2007;157:534–544. doi: 10.1016/j.jsb.2006.11.008. [DOI] [PubMed] [Google Scholar]
  • 70.Whalen WJ. Intracellular Po2 in heart and skeletal muscle. Physiologist. 1971;14:69–82. [PubMed] [Google Scholar]
  • 71.Whalen WJ. Nair P. Ganfield RA. Measurements of oxygen tension in tissues with a micro oxygen electrode. Microvasc Res. 1973;5:254–262. doi: 10.1016/0026-2862(73)90035-6. [DOI] [PubMed] [Google Scholar]
  • 72.Whalen WJ. Riley J. Nair P. A microelectrode for measuring intracellular pO2. J Appl Physiol. 1967;23:789–794. doi: 10.1152/jappl.1967.23.5.798. [DOI] [PubMed] [Google Scholar]
  • 73.Wilson DF. Lee WM. Makonnen S. Apreleva S. Vinogradov SA. Oxygen pressures in the interstitial space of skeletal muscle and tumors in vivo. Adv Exp Med Biol. 2008;614:53–62. doi: 10.1007/978-0-387-74911-2_7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 74.Wilson DF. Lee WM. Makonnen S. Finikova O. Apreleva S. Vinogradov SA. Oxygen pressures in the interstitial space and their relationship to those in the blood plasma in resting skeletal muscle. J Appl Physiol. 2006;101:1648–1656. doi: 10.1152/japplphysiol.00394.2006. [DOI] [PubMed] [Google Scholar]
  • 75.Ye JM. Colquhoun EQ. Clark MG. A comparison of vasopressin and noradrenaline on oxygen uptake by perfused rat hindlimb, kidney, intestine and mesenteric arcade suggests that it is in part due to contractile work by blood vessels. Gen Pharmacol. 1990;21:805–810. doi: 10.1016/0306-3623(90)91037-r. [DOI] [PubMed] [Google Scholar]

Articles from Antioxidants & Redox Signaling are provided here courtesy of Mary Ann Liebert, Inc.

RESOURCES