INTRACORPOREAL HEAT DISSIPATION FROM A RADIOISOTOPE-POWERED ARTIFICIAL HEART

Fred N Huffman 1, Kenneth G Hagen 1, Robert L Whalen 1, John M Fuqua 1, John C Norman 2
PMCID: PMC287500  PMID: 15215968

Abstract

The feasibility of radioisotope-fueled circulatory support systems depends on the ability of the body to dissipate the reject heat from the power source driving the blood pump as well as to tolerate chronic intracorporeal radiation. Our studies have focused on the use of the circulating blood as a heat sink. Initial in vivo heat transfer studies utilized straight tube heat exchangers (electrically and radioisotope energized) to replace a segment of the descending aorta. More recent studies have used a left ventricular assist pump as a blood-cooled heat exchanger. This approach minimizes trauma, does not increase the area of prosthetic interface with the blood, and minimizes system volume. Heat rejected from the thermal engine (vapor or gas cycle) is transported from the nuclear power source in the abdomen to the pump in the thoracic cavity via hydraulic lines. Adjacent tissue is protected from the fuel capsule temperature (900 to 1200°F) by vacuum foil insulation and polyurethane foam. The in vivo thermal management problems have been studied using a simulated thermal system (STS) which approximates the heat rejection and thermal transport mechanisms of the nuclear circulatory support systems under development by NHLI. Electric heaters simulate the reject heat from the thermal engines. These studies have been essential in establishing the location, suspension, surgical procedures, and postoperative care for implanting prototype nuclear heart assist systems in calves. The pump has a thermal impedance of 0.12°C/watt. Analysis of the STS data in terms of an electrical analog model implies a heat transfer coefficient of 4.7 × 10−3 watt/cm2°C in the abdomen compared to a value of 14.9 × 10−3 watt/cm2°C from the heat exchanger plenum into the diaphragm.

Full text

PDF
343

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bernhard W. F., Bankole M. A., LaFarge C. G., Bornhorst W., Frieze S., Curtis G. W. Development of an experimental model for functional cardiac replacement. Surgery. 1971 Aug;70(2):205–214. [PubMed] [Google Scholar]
  2. Bernhard W. F., LaFarge C. G., Husain M., Yamamura N., Robinson T. C. Physiologic observations during partial and total left heart bypass. J Thorac Cardiovasc Surg. 1970 Dec;60(6):807–817. [PubMed] [Google Scholar]

Articles from Cardiovascular Diseases are provided here courtesy of Texas Heart Institute

RESOURCES