Therapeutics of Diabetes Mellitus: Focus on Insulin Analogues and Insulin Pumps

Vasiliki Valla 1,*
PMCID: PMC2877202  PMID: 20589066

Abstract

Aim. Inadequately controlled diabetes accounts for chronic complications and increases mortality. Its therapeutic management aims in normal HbA1C, prandial and postprandial glucose levels. This review discusses diabetes management focusing on the latest insulin analogues, alternative insulin delivery systems and the artificial pancreas. Results. Intensive insulin therapy with multiple daily injections (MDI) allows better imitation of the physiological rhythm of insulin secretion. Longer-acting, basal insulin analogues provide concomitant improvements in safety, efficacy and variability of glycaemic control, followed by low risks of hypoglycaemia. Continuous subcutaneous insulin infusion (CSII) provides long-term glycaemic control especially in type 1 diabetic patients, while reducing hypoglycaemic episodes and glycaemic variability. Continuous subcutaneous glucose monitoring (CGM) systems provide information on postprandial glucose excursions and nocturnal hypo- and/or hyperglycemias. This information enhances treatment options, provides a useful tool for self-monitoring and allows safer achievement of treatment targets. In the absence of a cure-like pancreas or islets transplants, artificial “closed-loop” systems mimicking the pancreatic activity have been also developed. Conclusions. Individualized treatment plans for insulin initiation and administration mode are critical in achieving target glycaemic levels. Progress in these fields is expected to facilitate and improve the quality of life of diabetic patients.

1. Introduction

Diabetes, being one of the primary causes of increased cardiovascular morbidity and mortality in Western countries, constitutes a large burden to health care systems in terms of both direct and indirect costs.

Therefore, efficient glucose control (attainment of normal HbA1C, prandial and postprandial glucose levels) is essential to the prevention of life-threatening complications of the disease.

However, most patients fail to sustain long-term, adequate control through life-style modifications or even combined oral medications [1, 2] (biguanides, sulfonylureas, meglitinides, glitazones, incretin mimetics, or DPP-4 inhibitors). Indeed, multidrug therapies are currently reconsidered, with recent studies questioning their long-term therapeutic benefit over side effects or disease complications [3].

Thus, the increasing need of aggressive diabetes treatment has led to the improvement of insulin therapy and its implementation techniques. The development of continuous subcutaneous insulin infusion (CSII) pumps and short-acting insulin analogues exhibiting beneficial pharmacokinetic properties represents important advances in the treatment of diabetes and will be reviewed herein.

2. Insulin Therapy

A number of studies confirm that sufficient glycaemic control reduces the risk of developing diabetes-associated complications leading to increased mortality and morbidity. The United Kingdom Prospective Diabetes Study (UKPDS) [4] has shown that a decrease in HbA1C by 1% is associated with 37 and 14% reduction in the risk of microvascular and macrovascular complications, respectively. The link between cardiovascular risk and insufficient glycaemic control has been also confirmed in numerous trials [5, 6], gradually leading to strict guidelines, given the underlying increase mortality and morbidity.

Currently, ADA and IDF recommend target HbA1C levels of <7.0 and ≤6.5%, respectively, while the jointed ESC-EASD guidelines recommend that HbA1C target levels should be ≤6.5% in order to reduce cardiovascular risk [710].

Although strict, the official guidelines are poorly met within the diabetic community. In a retrospective analysis of the United Kingdom General Practice Research database [11] published in 2002, 76% of patients were found to have mean HbA1C levels ≥7.0%, while on multidrug therapy including combinations of two or more oral antidiabetic agents (OADs). On the other hand, evidence from lifestyle intervention studies that encouraged weight loss through dietary changes and increased physical activity shows that both the risk of developing diabetes and the progression of the disease may be reduced [12, 13]. However, it is common knowledge that no long-term patient compliance—thus therapeutic efficacy—may be expected. Inevitably, intensive insulin therapy is to be considered for reaching HbA1C targets, as supported by UKPDS, which showed that >60% of type 2 diabetic patients will need insulin within 5 years of diagnosis [4, 14].

Therapeutic algorithms suggest that during early phases of the disease (when the pancreas maintains its secretory ability) should be treated aiming to decrease insulin resistance, then followed by basal insulin. The last therapeutic step is the combination of basal with preprandial insulin to control postprandial glucose fluctuations [14].

Lately, there is a tendency for early initiation of insulin administration but unfortunately, this strategy is held back by the fear of hypoglycaemia, weight gain, and injections [15]. Ideally, insulin therapy restores glycaemic control without interfering with patients' quality of life. This is accomplished by insulin schemes restoring physiological insulin secretion, thus controlling both baseline and postprandial glucose regulation. Therefore, the combinatorial scheme of long-acting basal insulin with rapid-acting analogues is becoming more popular [16]. In any case, it should be taken into account that poorly controlled patients need to manage fasting blood glucose (FBG) levels before postprandial glycaemias.

Insulin preparations are characterized by the onset of action, peak effect, and duration of action. The current classification includes rapid, short, intermediate, and long-acting products. The insulin's source determines its pharmacokinetic characteristics.

The newer insulin analogues have several improvements due to their modified action profile [17]. Main advantages of short-acting preparations include the faster onset of action and shorter duration time. Long-acting analogues afford structural changes, which delay the onset of action, allow slow and continuous absorption into the systemic circulation, and prolong the duration, thus producing a time-concentration profile, which imitates the normal insulin basal level and leads to physiological basal glycaemic control with less nocturnal hypoglycaemias [18].

In spite of the clinical superiority, the potential mitogenic effect of some analogues remains to be clarified and constitutes a fundamental safety issue. Insulin and IGF-1 receptors display >50% of amino acid sequence homology and even >84% in the tyrosine kinase domain, while both ligands bind to both receptors. On the other hand, insulin molecule modifications in the B10 and B26-B30 region alter the affinity towards the IGF-1 receptor. This has raised the question of mitogenic potential, which may be resulting from an enhanced affinity towards the IGF-1 receptor or because of the occupancy time of the insulin receptor by the analogue. So far, no reliable data on this has been published [19].

Table 1 summarizes the main characteristics of rapid and long-acting insulin analogues described below.

Table 1.

Main characteristics of rapid and long-acting insulin analogues.

Analogue Trade name/manufacturer Onset (min) Peak (hrs) Duration (hrs)
Long-acting analogues
 Glargine Lantus/Sanofi-Aventis 4–6 hrs No peak >24 hrs
 Detemir Levemir/Novo Nordisk 4–6 hrs 8–10 hrs ~17 hrs
Rapid-acting analogues
 Lispro Humalog/Eli Lilly 15–30 min 0.5–2.5 hrs 3–6.5 hrs
 Aspart Novorapid/Novo Nordisk 10–20 min 1–3 hrs 3–5 hrs
 Glulisine Apidra/Sanofi-Aventis 10–15 min 1–1.5 hrs 3–5 hrs

3. Rapid-Acting Insulin Analogues

3.1. Insulin Lispro

Insulin lispro [20, 21] (Humalog) (Figure 1) is the first genetically engineered rapid-acting insulin analogue, approved for clinical use in 1996. Its structure differs from human insulin in the B-chain where proline at position 28 and lysine at position 29 are reversed, leading to a molecule with reduced capacity of self-association in solution (therefore faster absorbed, with higher peak serum levels and shorter action duration in comparison to regular insulin). Besides glycemic management, lispro improves the postprandial leptin and grehlin regulation of type 1 diabetic patients and may be used in cases of gestational diabetes.

Figure 1.

Figure 1

The amino acid structure of rapid-acting insulin analogues. The molecular modifications on the insulin molecule are shown.

3.2. Insulin Aspart

Insulin aspart [20, 22] (NovoRapid) (Figure 1) structure differs from human insulin at position 28 where a proline is substituted with the charged aspartic acid, allowing it to be absorbed twice as fast as human insulin. It causes better glycaemic control when administered directly before a meal. Administration of aspart during pregnancy of type 1 diabetic women has been associated with reduced risk of nocturnal hypoglycaemia.

3.3. Insulin Glulisine

Insulin glulisine [20, 23, 24] (Apidra) (Figure 1) is the most recent rapid-acting analogue, launched in 2004. Its structure differs in two points from human insulin: asparagine at position 3 is substituted by lysine and lysine at position 29 by glutamic acid. These alterations reduce hexamers formation and enhance absorption from subcutaneous depots. Insulins lispro and glulisine have the same impact on the glycaemic control of type 1 diabetic patients but when evaluating their potential on obese, type 2 diabetic subjects, the rise in insulin concentration and onset of activity is faster for glulisine. In addition, the pharmacokinetic and pharmacodynamic profile of glulisine does not exhibit negative correlation with BMI and subcutaneous fat thickness (which is the case for lispro).

4. Long-Acting Basal Insulin Analogues

4.1. Insulin Glargine

Insulin glargine [25, 26] (Lantus) (Figure 2) is the first long-acting insulin analogue having amino acid modifications in both chains. In the A-chain, the asparagine at position 21 is substituted by glycine and the B-chain is elongated at the C-terminus by addition of two arginine residues. Glargine is a molecule with a changed isoelectric point towards neutral, bearing decreased solubility at physiological pH. This causes precipitation after injection in subcutaneous tissue, stabilization of insulin hexamers, delay of their dissociation, and steady absorption into the circulation. Consequently, insulin glargine bears a stable serum concentration without pronounced peaks and significantly elongated duration of action, which covers the patient for 24 hours. Its onset of action is approximately 2 hours after injection. Compared to NPH or ultralente, glargine affords decreased hypoglycaemic events, less fluctuations, and lower risk of nocturnal hypoglycaemia.

Figure 2.

Figure 2

The amino acid structure of insulin glargine and detemir showing the key modifications that result in the prolonged duration of action.

4.2. Insulin Detemir

Insulin detemir [25, 27] (Levemir) (Figure 2) is characterized by acylation of myristic acid to the lysine residue at position 29 in the B-chain and deletion of the last threonine (position 30) in the B-chain. Its protracted action is achieved through delayed resorption caused by the increased self-association and reversible albumin binding at the injection site as well as because albumin binding causes buffering of insulin concentration. This results in a flat, prolonged pharmacodynamic profile, which provides a metabolic effect for approximately 17 hours. When compared to NPH and glargine, it offers better weight gain control and results in comparable overall risk of hypoglycaemia.

5. Clinical Efficacy and Safety Profile of Rapid and Long-Acting Insulin Analogues

In the Treat-to-Target study [28], insulin glargine was compared to NPH. Both were given at bedtime starting with 10 U, with an aggressive dose titration to achieve a fasting glucose level <100 mg/dL. Both insulins resulted in a substantial decline in fasting glucose and HbA1C, with no difference between groups. Although the FBG target was not achieved in many patients, ~60% of them in both groups achieved their target for HbA1C (<7%) within the 24-week trial period. However, use of glargine was associated with fewer hypoglycemias, including nocturnal ones, in relation to NPH. Similar results have been obtained with insulin detemir when added as basal insulin for type 2 diabetic patients insufficiently controlled with OADs.

In the INSIGHT study [29] (implementing New Strategies with Insulin Glargine for Hyperglycaemia Treatment), type 2 diabetic patients (HbA1C levels 7.5–11.0%) on stable therapy with 0–2 OADs, not including thiazolidinediones, were randomized to either an optimised OAD regimen (with no insulin) or initiation of bedtime glargine (with no increase in the oral therapy). The decreases in HbA1C and FPG were higher with glargine compared to OAD therapy (P = .005 and P = .0001, resp.), with no difference in hypoglycaemia incidences. The INSIGHT study proved that early initiation of insulin glargine improves glycaemic control and is more effective compared to optimised diet/oral therapy alone.

The Triple-Therapy Trial [30] compared patients with type 2 diabetes insufficiently controlled with dual oral therapy (metformin-sulfonylurea). Patients were randomised to additionally receive either rosiglitazone or insulin glargine; the doses of which were increased to optimise control. Although similar improvements in HbA1C were observed with glargine (−1.7%) and rosiglitazone (−1.5%), patients receiving rosiglitazone experienced more hypoglycaemias, peripheral oedema, and weight gain. At the end of the study, more patients in the rosiglitazone group had withdrawn. This study demonstrated that single basal insulin administration offers an effective and well-tolerated alternative to further oral drug escalation.

Although clearly demonstrated that basal analogues provide satisfactory glycaemic control, their effects on cardiovascular outcomes have been questioned in a recent meta-analysis comparing glargine and/or detemir with NPH [31]. The rates of overall and nocturnal hypoglycaemias were significantly lower in the glargine- and detemir-treated patients but no clinical evidence could support their beneficial effect on mortality, morbidity, or quality of life. However, longer-term studies with glargine or detemir have repeatedly reported on the enhancement of the quality of life and treatment satisfaction.

The effects of rapid- and long-acting analogues on HbA1C levels have been thoroughly studied. In a review of 49 randomized clinical studies comparing analogues with regular human insulin in type 1 diabetic patients, a mean difference in HbA1C of −0.1% was assigned in favour of the first [32]. Among type 2 diabetic patients, there was no difference between rapid-acting analogues and regular human insulin. In a similar review of eight studies comparing long-acting analogues with NPH in type 2 diabetic patients, there was no clinically meaningful difference in HbA1C levels between the two types. It should be taken into account though that basal insulin trials are usually designed to titrate dosing as needed to achieve preset HbA1C targets [31].

A number of studies have also assessed HbA1C levels in patients treated with premixed human insulins versus premixed insulin analogues, including premixed lispro and aspart formulations [32] but the results are contradictory. Only one study showed small improvements in HbA1C levels after treatment with 50/50 premixed insulin lispro relative to premixed human insulins, while the others favoured premixed insulin analogues. In general, patients on premixed insulin analogues exhibit improved postprandial glucose control in comparison to premixed human insulins, probably because of the faster action of the first [33].

The increased risk of hypoglycaemic events remains a major disadvantage of insulin therapy, preventing physicians from applying even more aggressive dosage schemes to lower HbA1C levels.

In the DCCT trial [34] (Diabetes Control and Complications Trial), the incidence of severe hypoglycemias was 3-fold higher in the intensive treatment group compared to the conventional treatment cohort (P < .001). Moreover, the risk of severe hypoglycemias increased as monthly HbA1C values declined.

An interesting follow-up of the DCCT has been published. One of the diabetes centres of the initial trial continued to monitor HbA1C levels from 1993 to 1998 for 884 type 1 diabetic patients. During 1993 and 1996, HbA1C continuously declined and that was evidently associated with a significant increase in the number of severe hypoglycemic events (P < .001). On 1996, when insulin lispro was launched, 676 patients switched treatment. Surprisingly, HbA1C levels continued to improve (P < .001) in the patients switched to lispro, but there was no corresponding increase in the rates of severe hypoglycemia (P = .26) [35]. More than that, HbA1C levels did not show further improvement in the subjects who remained on regular insulin. These data suggest that intensive therapy with insulin analogues may not be associated with the same hypoglycemia risks as older formulations.

Data on rapid-acting analogues suggest a lower median incidence of severe hypoglycemic episodes per 100 person-years (21.8; range from 0 to 247.4) compared with regular insulin (46.1; range from 0 to 544). Likewise, basal insulin analogue trials exhibit significantly lower risks of nocturnal hypoglycemia with glargine (P = .00003) and detemir (P < .00001) relative to NPH. The rate of severe hypoglycemia is lower with both basal insulin analogues [36].

Regarding the critical issue of weight gain, numerous studies have documented that insulin-deriving improvements in glycemic control are frequently accompanied by undesirable increases in body weight [37]. In the DCCT and the Swedish National Diabetes Register trials, modest weight increases were negatively correlated with lipid profiles and systolic blood pressure. Weight gain is highly undesirable especially in type 2 diabetic patients given that more than 80% of them are already overweight.

Insulin-mediated weight gain has been attributed to reduced urinary glucose excretion (calorie retention) and to metabolic rate slow down, both resulting from the improved glucose metabolism. The anabolic activity of insulin on both adipose and muscle tissues may be held responsible for prolonged periods of weight gain, even beyond the initial phase of “glucose control-related” weight gain. The rate of weight gain is often greatest during the early months of therapy when glycemic control is also undergoing intensive correction, a parameter, which may interfere with the patient's adjustment to insulin therapy and possibly create an obstacle to his compliance [38].

For reasons not yet fully understood, some data indicate that insulin detemir has a weight-sparing effect [39]. Trials in patients with type 1 and type 2 diabetes have reported significantly less weight gain in comparison to NPH. While some studies have shown that patients treated with glargine initially gain less weight in comparison to those treated with NPH, no difference between glargine and NPH has been noted in patients treated for 1 year. Moreover, in a recently reported study, patients with type 2 diabetes were switched from NPH or glargine to detemir in combination with oral antidiabetic drugs. Fourteen weeks after the switch to detemir, mean body weight was significantly reduced in patients previously using both NPH (−0.7 kg; P < .01) and glargine (−0.5 kg; P < .05) [40].

The impact on quality of life is another factor to be considered when administering insulin therapy. Parameters that may deteriorate quality of life include the patient's concerns about needles, frequent injections, severe hypoglycemias, and weight gain. On the other hand, improved glycemic control itself enhances the patient's state of mind and improves all aspects of everyday activities (including sexual life), therefore motivating treatment compliance [41].

6. Continuous Subcutaneous Insulin Infusion (CSII)

The first continuous subcutaneous insulin infusion (CSII) system was developed in 1976 and had the size of a backpack. Initial CSII indications focused on patients who suffered from severe hypoglycemic episodes or hypoglycemic unawareness and type 1 diabetic patients with dawn phenomenon [42].

CSII is the implantation of an infusion system into the surface of the body for the delivery of insulin. Currently, it is not implanted within the body nor is a closed-loop system. The system (Figure 3) consists of an external device containing a computer, an insulin reservoir containing up to 300 units of rapid-acting insulin, and a screw-drive pumping device. The insulin pump is attached via tubing to a subcutaneously implanted needle (usually in the abdomen) [43].

Figure 3.

Figure 3

Main parts of an insulin pump.

In more detail, the basic system includes an insulin pump, a plastic needle with a stainless steel stylet for insertion, which is placed in the subcutaneous tissue and plastic tubing connecting a computer reservoir to the implanted needle. In addition, a quick-release mechanism allows the tubing to be disconnected from the implanted needle in the abdomen for temporary pump interruption [44, 45]. Pump components include

  1. a disposable plastic reservoir that is filled with insulin,

  2. a screw drive mechanism for “pushing” the insulin through the plastic tubing at different rates,

  3. a small computer that has a memory loop designed to dispense insulin as programmed,

  4. a battery source for power.

CSII function is based on the physiologic endogenous insulin secretion [46]. The normal pancreas secretes a varying, basal amount of insulin throughout the day and additional bolus amounts of insulin are secreted to cover the increased prandial needs as a response to the carbohydrates absorption from the gastrointestinal tract.

The ideal insulin replacement program should mimic the above endogenous system [47]. The basal secretion is reproduced by the constant slow infusion of rapid-acting analogues. The rate of constant basal infusion can be altered to meet the 24-hour requirements of each individual.

Bolus injections of rapid-acting analogues are infused via CSII prior to meals or carbohydrate intake, controlling postprandial glycaemias. Candidates must be well motivated and aware of basic insulin pharmacodynamics, carbohydrate counting, and insulin pump technology. Frequent decision-making is required, therefore patients must be able to assess situations and operate a computerized insulin pump. Patients who are not achieving treatment target goals via intensive insulin therapy are also potential candidates [48]. Table 2 summarizes current indications and contradictions of insulin pump therapy.

Table 2.

Indications, limitations and contraindications of CSII in diabetic patients.

Long-term indications
When clear proven benefit over MDI
is proven and when other intensified
insulin regimens fail to achieve
adequate glycaemic control.
Short-term indications Contradictions
(1) Elevated HbA1c with MDI therapy
(2) Marked same-day or between-day glucose
levels fluctuations
(3) Variability of insulin requirements
 (i) Endogenous causes: dawn phenomenon
 (ii) Exogenous causes: work type
particuliarities (e.g., shift workers or
business travellers)
(4) Recurrent hypoglycaemia (severe or
non-severe)
 (i) Failure to maintain HbA1c targets
(<7.0%) without the occurrence of
disabling or frequent symptomatic or
asymptomatic hypoglycaemic events
(≥4/week)
 (ii) Incidence of ≥1 episode(s)/year of
unexplained severe hypoglycaemia
(5) Other reasons:
 (i) Allergy to insulin
 (ii) Lipoatrophic diabetes
 (iii) Very low insulin requirements
(1) Acute situations (e.g., in diabetology units):
 (i) For the treatment of mild ketoacidosis
or acute hyperglycaemia
 (ii) For acute infections
 (iii) Undergoing enteral alimentation
(2) Transient situations
 (i) Severe painful neuropathy
 (ii) Chronic infections, foot ulcers and all
wound-healing cicatrization situations
 (iii) Pregnancy or the intention to become
pregnant
(1) Absolute Contradictions
  (i) Severe psychiatric disorders
  (ii) Progressive ischaemic or proliferative
retinopathy
  (iii) Due to the patient's environment or
pump:
  (a) A non-educated medical
environment
  (b) Living with extreme circumstances
of either heat or cold for professional
or personal reasons
  (c) Underwater diving
  (d) Exposure to high electromagnetic
fields (NMR)
(2) Relative Contradictions
 (i) Poor compliance or patient reluctance
to live with the current management
of treatment, (e.g., frequent visits to
diabetology centre, glycaemia
monitoring, ketosis testing)
 (ii) Poor local hygiene and/or
Staphylococcus presence
 (iii) In some cases of end-stage renal
failure because of acidosis risk
attributed to patient incompliance
 (iv) Sensory or gestural impairment
(difficulty with the technical aspects
of pump management)

The total daily dose (TDD) of insulin is calculated based on patient weight or current insulin requirements. If patients are switching to insulin pumps therapy from multiple injections therapy, the TDD is initially reduced by 20%. Alternatively, the initial dose is calculated based on patient weight multiplied by 0.53 IU/Kg (TDD = Wt [kg] × 0.53 U/kg) [49]. The total calculated basal insulin is set on a 1-hourly basal rate, which is adjusted based on fluctuations from the target glucose level. Individual glucose targets are set for different clinical situations (e.g., pregnancy or extensive physical activity) or during different times of the day (e.g., an increase in the basal rate is usually required during dawn hours to offset the rise in counter-regulatory hormones GH and cortisol). The bolus insulin dosage also takes into account the carbohydrate-to-insulin ratio (CIR) [50].

6.1. Clinical Studies

Several studies have shown the superiority of CSII over MDI in terms of HbA1C control. Among them, the DCCT Trial [51], in which HbA1C levels in the intensive treatment group were significantly lower with CSII than with MDI (−0.2 to −0.4%). To be noticed though that the patients were allowed to choose between CSII and MDI instead of being randomly allocated. Therefore these results have been questioned.

Nevertheless, Pickup et al. [52] and Weissberg-Benchell et al. [53], in their meta-analyses including more than 2100 patients, concluded on an overall advantage of CSII over MDI, with a decrease in HbA1C 0.4–0.5% and a corresponding reduction in insulin requirements.

Quality of life has been assessed in a limited number of studies, using different parameters and concepts. However, Barnard et al. [54] conclude that CSII has a favourable or neutral effect on quality of life, depression, and anxiety.

Several randomized controlled trials have shown that CSII with rapid-acting insulin analogues is more efficient for the control of postprandial glycaemia and HbA1C levels than CSII with regular human insulin. Colquitt et al. [55] have demonstrated that the use of insulin analogues with a pump results in a modest (0.26%) but significant reduction in HbA1C compared with soluble insulin.

The efficacy of CSII compared to MDI therapy has also been evaluated in adapting insulin schemes that combine rapid-acting with NPH insulin as basal insulin [56, 57]. The results suggest that CSII is associated with better glycaemic control, especially in initially suboptimally controlled patients. The relative benefit of CSII over MDI was greater for patients with high baseline HbA1C levels. Nevertheless, the results obtained with CSII were superior to those achieved with MDI, whatever the levels of baseline HbA1C.

The 5-Nations trial [58] was a randomized, controlled, crossover trial conducted in 11 European centers, in which 272 patients were treated with CSII or MDI during a 2-month run-in period followed by a 6-month treatment period. The quality of glycaemic control (HbA1C levels), blood glucose values, frequency of hypoglycaemic events, and parameters of life quality were assessed. Hoogma et al. concluded that CSII therapy offers less blood glucose variability and higher quality of life scores.

Pickup et al. [52] in his meta-analysis assessed CSII versus MDI therapy via the evaluation of 12 randomized, controlled trials and showed a reduction of 0.44 in HbA1C (confidence interval: 0.20–0.69) in patients using CSII. In addition, a reduction of up to 14% in total daily insulin requirements was found for patients using CSII.

The impact of basal insulin glargine on CSII therapy has also been investigated. Bolli et al. [59] showed similar glucose control with the two treatment options, while Doyle et al. [60] in a study recruiting children showed the superiority of CSII on HbA1C levels after 16 weeks, with significantly lower average insulin use. In detail, Doyle enrolled 32 conventionally treated subjects who were randomized to either CSII or a combination of insulin glargine and bolus doses of aspart. The CSII group was found to have lower HbA1C levels in comparison to both glargine group and the baseline HbA1C levels. FPG concentrations did not differ between the 2 groups, indicating similar adequacy of basal insulin replacement. However, SMBG performed at lunch, dinner, and bedtime demonstrated significantly lower blood glucose levels in the CSII group, suggesting that lack of compliance with bolus dosing contributes to higher blood glucose and HbA1C levels in the MDI group. In addition, preprandial and bedtime blood glucose values were lower; whereas prebreakfast values were similar, indicating better coverage with CSII. Hirsch et al. [61] in a randomized, crossover study in adults comparing CSII and MDI with insulin reported on lower fructosamine levels and fewer daily glycaemic excursions with CSII, as assessed by continuous glucose monitoring.

Most studies point out the fact that CSII superiority depends on patient screening and pre-CSII glycaemic profile. In a retrospective analysis of data from 17 diabetes outpatient clinics in Sweden, Fahlén et al. [62] showed that switching from MDI without long-acting analogues to CSII improved metabolic control, with a more pronounced effect associated with CSII, particularly in patients with higher HbA1C levels and BMI at baseline.

In all, clinical studies indicate that adult patients, with type 1 diabetes mellitus, are favoured by CSII treatment in comparison to MDI therapy and are led to a better glycaemic control with less hypoglycaemic episodes and insulin requirements [63].

6.2. CSII in Paediatric Patients

There is plenty of evidence that both children and adolescents are favoured by CSII equally or more than MDI [64] (Table 3). Cohort studies provide evidence of a significant benefit when paediatric patients on MDI are converted to CSII.

Table 3.

CSII therapy in pediatric patients.

Current indications
 Recurrent severe hypoglycemia
 Wide fluctuations in blood glucose levels regardless of HbA1c
 Suboptimal diabetes control
 Microvascular complications and/or risk factors for macrovascular complications
 Good metabolic control but insulin regimen that compromises lifestyle (e.g., competitive athletes and needle phobia)
 Adolescents with eating disorders
 Children and adolescents with a pronounced dawn phenomenon
 Ketosis-prone individuals

Advantages of CSII compared with MDI in children

 Easier and convenient adjustment of bolus insulin dose and nocturnal basal insulin dose
 Greater accuracy of insulin dosage
 Easier management of infectious illnesses and hyperglycemic episodes
 Quality of life improvement
  Less injections ⇒ Less anxiety ⇒ better compliance
  Flexibility of everyday activities

For example, Weinzimer et al. [65] found that HbA1C levels continued to fall 4 years after conversion to CSII in young children (mean age 4.5 years; n = 65). Sulli and Shashaj [66] have discussed the long-term benefits of CSII observed in older children, with a mean age of 12 years (n = 42), followed-up for 4 years after therapy initiation. Recently, Jakisch et al. [67] reported on a prospective study of paediatric patients initiated on CSII or MDI in Germany (n = 434 matched pairs). Superior HbA1C control was achieved by CSII during the first year (7.5% versus 7.7% with MDI; P < .006) but was not maintained until the third (8.1% versus 8.0%, resp.; P < .99). However, CSII was associated with statistically significant reductions in hypoglycaemic and DKA episodes and insulin requirements throughout the follow-up period. Weinzimer et al. [68] randomized almost 300 children and adolescents to 16 weeks of CSII therapy with insulins lispro or aspart. Although a numerically greater reduction in HbA1C with aspart did not reach statistical significance, more patients treated with aspart (59.7%) achieved target HbA1C levels compared with patients treated with lispro (43.8%; P < .04).

Hypoglycaemic episodes constitute an obstacle for many insulin-treated children especially when low glycaemic targets are set. In principle, CSII should reduce the risk of hypoglycaemia. Indeed, Pickup and Sutton [69] in a recent meta-analysis of 21 studies showed that CSII was associated with a 75% lower rate of severe hypoglycaemia compared to MDI. The reduction in hypoglycaemia was the greatest in patients with a high hypoglycaemia rate while on MDI. On the other hand, convenience should be secured to children, for whom MDI administration becomes frustrating when trying to achieve hard glycaemic targets. CSII is more convenient with regard to injection frequency, as the subcutaneous cannula needs to be resited once every 2-3 days. McVean et al. [70] partially attribute the effectiveness of CSII in children to the number of cannula sites used, perhaps due to improved insulin absorption. CSII has been shown to improve the well-being of both children with type 1 diabetes and their parents. Treatment satisfaction is higher among children randomized to CSII than MDI. Recently, Hanas and Ludvigsson [71] detected a small increase in DKA in paediatric patients treated with CSII, as compared with MDI, especially early after CSII initiation. Contradicting that, Jakisch et al. [67] found that a lower baseline incidence of DKA in the CSII group was maintained throughout the 3 years of follow-up of his trial. DKA in pump users is most likely to occur when patients do not realize the malfunctioning of the pump. Thus, proper training and monitoring can minimize the problem. Type 1 diabetic children and adolescents benefit an improved quality of life [7275] and sufficient glycaemic control when switching to CSII as long as they get accustomed to the mechanical aspects of their treatment.

6.3. CSII in Pregnancy

Glycaemic control is crucial during pregnancy for both mother and foetus, because of the close relationship between blood glucose levels and pregnancy outcome [76]. However, achieving stable glucose levels during pregnancy is challenging because of the increased risk of hypoglycaemia due to the passive diffusion of glucose across the placenta and changes of counter-regulatory hormones. In addition, glycaemic control maintenance is difficult because of the continuous insulin requirement alterations, which are decreased in the first trimester and increased in the second half of pregnancy [77].

The use of CSII during pregnancy dates back to the early 1980s. Initially, CSII was used during the third trimester to prevent macrosomia, but later its use was extended. CSII can be safely started during pregnancy, but it is preferable to start before conception, in order to minimize malformations risk and allow proficiency with the pump. Potential patients should be compliant with capillary glucose testing (8 to 10 times a day) and willing to monitor ketone bodies [78].

According to ADA guidelines, the goal for FPG before meal should be ≤105 mg/dL, while the 2 hours postprandial plasma glucose should not exceed 130 mg/dl. Currently, insulins lispro and aspart are indicated for administration via CSII in gestational diabetes [79].

The majority of the studies conducted in pregnant women are observational involving both types 1 and 2 diabetic patient [80]. The number of randomized, controlled trials comparing CSII and MDI is scarce and include a relatively small number of participants. Mukhopadhyay et al. [81] attempted to review the available data and meta-analyzed 6 studies with a total of 213 pregnant diabetic women randomized on CSII or MDI therapy. Data evaluation considered the weighted mean difference and odds ratio for insulin dose, birth weight, gestational age, delivery mode, hypoglycemic episodes, worsening retinopathy, neonatal hypoglycemia, and rates of intrauterine fetal death. Pregnancy outcomes and glycemic control were not significantly different among treatment groups. Yet, a higher number of DKA episodes and diabetic retinopathy were found in the CSII group (not statistically significant). The authors could not conclude on the superiority of one treatment and suggested that large multicenter, randomized, controlled trials are required for this patients group.

Although a clear-cut advantage of CSII over MDI during pregnancy does not emerge from the literature, CSII provides greater flexibility in lifestyle, allows an easier control of morning nausea, decreases the number of hypoglycaemic episodes, decreases blood glucose variability, alleviates the dawn phenomenon, copes more easily with delayed gastric emptying, and eases blood glucose control around delivery [82].

7. Continuous Subcutaneous Glucose Monitoring (CGM)

The DCCT trial [34] established the correlation of sufficient glucose control with reduced microvascular complications risk. Frequent glucose monitoring was found to be a determining factor for the achievement of glucose control.

Up until a few years ago, self-monitoring of blood glucose (SMBG) was considered effective for both types of diabetes since it contributed to the improvement of HbA1C and the delay of long-term diabetes complications [83]. However, this technique has suffered some drawbacks. Noninsulin treated diabetic patients show minimum compliance on the grounds of inconvenience and unnecessary pain. On the other hand, measurements scheduling is often poor resulting in useless, incorrectly interpreted information not applicable to an individualized therapy. However, and despite the above difficulties, SMBG is recommended for the management of diabetes in all the major guidelines [84].

On the other hand, continuous glucose monitoring (CGM) provides detailed information regarding blood glucose fluctuations throughout the day, enabling treatment decisions for the diabetic patient. Compared with SMBG, continuous monitoring provides much greater insight into glucose levels throughout the day, enabling the detection of postprandial glucose excursions and nocturnal hypoglycemias or hyperglycemias even in patients whose HbA1C levels suggest a satisfactory blood glucose control [85, 86].

Visualization of the glucose curve over time in relation to meals consumed and exercise assists the patient to comprehend the importance of dosage adjustments. The graphs shown by CGM further enable the patient to self-manage his glucose levels according to his activities and lifestyle. Even more important, the visible data of “on-line” or unblinded systems of CGM help the patient realize the real-time effects of acute treatment decisions as well as their delayed effects [87].

There are several devices for CGM but only two are usually used. One is the Holter-type of glucose monitoring, where results are shown and analyzed retrospectively; the second uses real-time presentation of glycaemic values. The CGMS of Medtronic (Minimed, Northridge, CA, USA) was the first device approved and remains popular both in USA and Europe. It provides a retrospective graphical view of the glycaemic profile measured during the last three days [88].

During the years, both invasive and noninvasive CGM techniques have been developed but up to now, only the first have been approved for clinical use. The invasive techniques include the insertion of a subcutaneous glucose sensor that measures interstitial fluid glucose as it osmotically diffuses from the peri-capillary area towards the cells, using either enzymatic (glucose oxidase) or microdialysis technology. Interstitial glucose may lag behind blood glucose by as much as 20 minutes when blood glucose levels are changing rapidly. These devices require calibration using capillary blood determinations. Each sensor continuously measures glucose levels for up to 3–7 days, giving a read-out every 1–10 minutes. The presently available CGM devices provide either historic readouts or real-time reporting. They are also equipped with alarms warning of impending hypo or hyperglycemia [89].

CGM requires thorough education of both the patient and the physician in order to use the readings properly for the adjustment of treatment. Furthermore, the optimal use of CGM requires the ability to perform blood determinations necessary for calibration. It should be noticed, that to date, CGM systems have not been approved for replacement of traditional SMBG devices, which should be used when continuous monitoring results do not reflect the way the patient feels, prior to medication administration or responding to threshold alarms and certainly when the CGM system is being calibrated so as to ensure accurate calculation of glucose readings [90].

So far, CGM is indicated [91]

  1. to observe and determine glucose fluctuations: its magnitude, duration, frequency and potential causes,

  2. to determine the amount of time a patient spends in out-of normal glucose ranges,

  3. to diagnose and prevent hypoglycemia,

  4. To determine the impact of lifestyle modification and diet composition on glucose control,

when screening patients for CGM usage, the physician should also take into account some of its current drawbacks [92, 93] and most importantly the:

  1. inaccuracy of single point measurements compared to SMBG, particularly in hypoglycemic levels,

  2. delay of glucose measurements,

  3. disparity of interstitial glucose measurements,

  4. need for frequent recalibration.

Furthermore, the technique is invasive and patients tend to reject it. The fact that the technology is best in real-time function constitutes another problem because of the intensive education required before being able to make real-time therapeutic decisions. The cost is also a matter to consider given that reimbursement is not available in many countries.

In conclusion, CGM technologies continuously improve and tend to be incorporated into everyday practice of diabetic management. Therefore, more interventional trials evaluating the effects of glucose fluctuations on diabetic complications should be conducted to enhance their efficiency and safety.

8. Artificial “Closed-Loop” Systems—Artificial Pancreas

Continuous subcutaneous glucose sensing (CGS) is the most recent advance in the control of serum glucose. Real-time continuous glucose sensors have the potential to revolutionize the treatment of diabetes mellitus.

A closed loop system monitors glucose levels and supplies insulin accordingly [94]. The ideal closed-loop system, or “artificial pancreas,” should contain three basic elements [95]:

  1. a safe-delivery device that stores and releases insulin reliably and accurately (insulin pump),

  2. an accurate, biocompatible glucose-sensing unit potent of frequent or continuous sampling (control algorithm),

  3. a control system modulating insulin delivery, glucose and maybe glucagon or amylin according to blood glucose levels (continuous monitor).

Additionally, the microcomputer system in an artificial pancreas will sample, filter, and interpret the glucose sensor data, to compare the reading with allowable norms and to accurately control insulin in order to achieve normalized blood glucose levels. This process should operate continuously without mistakes so as to avoid errors leading to severe hypo- or hyperglycemias. This autonomous function is supposed to resemble glucose responsive insulin secretion from the pancreas and should be a fully closed loop approach [96].

Unfortunately, the accuracy of the current continuous glucose sensors and algorithms is not yet sufficient to permit the loop to be closed. The open loop requires no autonomous control system, as it is the patient who manages insulin delivery on the basis of blood glucose data provided by the sensor. The closed loop, on the other hand, requires a control algorithm to adjust the administered insulin dose according to blood glucose levels [97]. The feasibility of this therapy has been demonstrated in small studies but its performance has not been tested for home use.

Currently, two modalities are being developed.

The first is an extracorporeal subcutaneous-subcutaneous approach [98] that utilizes subcutaneous glucose monitoring combined with subcutaneously delivered insulin. The minimally invasive nature of this system offers a strong advantage. Its most important drawback lies in the lag time between glucose measurement and insulin delivery, which may be up to 40 minutes followed by the rapid-acting analogue administration, which requires up to 15 minutes for an effect to occur.

The second is an implantable intravenous–intraperitoneal system [99] in which glucose monitoring occurs intravenously and insulin delivery is performed intraperitoneally. This approach has a greater chance to achieve a fully closed loop system. The delays in the system are shorter than with the subcutaneous-subcutaneous method but it still has longer physiologic delays. With the implantable insulin delivery pump, insulin is introduced into the peritoneum, which is closer to physiologic delivery and absorption.

There are several obstacles in the development of an artificial pancreas [100, 101], one of which lies in the physiological difference between variations in interstitial glucose and plasma glucose levels. The system has to take into account the time for the sensor to measure the glucose, the time taken by the subcutaneous absorption of insulin and the irreducible time required for insulin action. The total amount creates a certain inertia depending on the speed of changes in plasma glucose concentrations. Another difficulty arises from controlling the rapid, postprandial blood glucose fluctuations. This is why a “mixed” open/closed concept [102] is currently being developed applying hybrid use of the algorithm: autonomous operation (closed loop) during the fasting and interprandial periods and manual, nonautonomous operation of the prandial bolus programmed by the patient according to meal time or composition (open loop).

9. Conclusions

The goal of diabetes treatment is to achieve tight glucose control, avoid chronic complications and limit hypoglycemic episodes frequency in everyday life.

Remarkable improvement has been made on this field with the introduction of insulin analogues. The rapid-acting analogues efficiently control postprandial glucose levels while the long-acting analogues imitate the normal insulin basal level and lead to physiological basal glycaemic control with less nocturnal hypoglycaemias.

On the other hand, CSII technology has revolutionalized the way insulin therapy is implemented, providing convenient and flexible insulin delivery during routine treatment in children and adolescents improving their quality of life and glycaemic control.

However, despite the considerable efforts to improve insulin pharmacokinetics and develop user-friendly monitors and miniaturized insulin pumps, the goal has not yet been achieved, thus research on automated artificial pancreas is in progress. Considerable work remains to be completed before algorithms for the automated regulation of glucose levels become available.

Other strategies for diabetes management are also on way. The transplantation of islets of Langerhans was made possible by developing new isolation and immunosuppressant methods. Nevertheless, their rate of success is still low and the number of donors remains insufficient. Insulin secreting cells are created in vitro but they are far from having the same response to glucose as the genuine β-cells.

Finally, biosystems aiming to mimick natural feedback by combining sensor function (to perceive glucose modification) and effector function (insulin delivery) are also under development in order to improve the everyday life of the diabetic patient.

The ultimate challenge on this field remains a device, which would afford

  1. sensor specificity in a way that the sensor will only respond to glucose variations,

  2. pharmacokinetics similar to normal pancreatic activity,

  3. administration comfort by simple long lasting injections (ideally one subcutaneous injection per week or month).

References

  • 1. Brunton S. Beyond glycemic control: treating the entire type 2 diabetes disorder. Postgraduate Medicine. 2009;121(5):68–81. doi: 10.3810/pgm.2009.09.2054. [DOI] [PubMed] [Google Scholar]
  • 2.Cobble ME, Peters AL. Clinical practice in type 2 diabetes: after metformin and lifestyle, then what? The Journal of Family Practice. 2009;58(supplement 11):S7–S14. [PubMed] [Google Scholar]
  • 3.Philippe J, Raccah D. Treating type 2 diabetes: how safe are current therapeutic agents? International Journal of Clinical Practice. 2009;63(2):321–332. doi: 10.1111/j.1742-1241.2008.01980.x. [DOI] [PubMed] [Google Scholar]
  • 4.United Kingdom Prospective Diabetes Study Group. Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33) Lancet. 1998;352:837–853. [PubMed] [Google Scholar]
  • 5.Selvin E, Wattanakit K, Steffes MW, Coresh J, Sharrett AR. HbA1c and peripheral arterial disease in diabetes: the atherosclerosis risk in communities study. Diabetes Care. 2006;29(4):877–882. doi: 10.2337/diacare.29.04.06.dc05-2018. [DOI] [PubMed] [Google Scholar]
  • 6.Meier M, Hummel M. Cardiovascular disease and intensive glucose control in type 2 diabetes mellitus: moving practice toward evidence-based strategies. Vascular Health and Risk Management. 2009;5:859–871. doi: 10.2147/vhrm.s4808. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Nathan DM, Buse JB, Davidson MB, et al. American diabetes association; european association for study of diabetes. Medical management of hyperglycemia in type 2 diabetes: a consensus algorithm for the initiation and adjustment of therapy: a consensus statement of the American Diabetes Association and the European Association for the study of diabetes. Diabetes Care. 2009;32(1):193–203. doi: 10.2337/dc08-9025. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Nathan DM, Buse JB, Davidson MB, et al. American diabetes association and the European association for the study of diabetes. Medical management of hyperglycaemia in type 2 diabetes mellitus: a consensus algorithm for the initiation and adjustment of therapy : aconsensus statement from the . Diabetologia. 2009;52(1):17–30. doi: 10.1007/s00125-008-1157-y. [DOI] [PubMed] [Google Scholar]
  • 9.British Cardiac Society. JBS 2: prevention of cardiovascular disease in clinical practice. Heart. 2005;91(supplement 5):v1–v52. doi: 10.1136/hrt.2005.079988. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Rydn L, Standl E, Bartnik M, et al. Guidelines on diabetes, pre-diabetes, and cardiovascular diseases: executive summary. The task force on diabetes and cardiovascular diseases of the European Society of Cardiology (ESC) and of the European Association for the Study of Diabetes (EASD) European Heart Journal. 2007;28(1):88–136. doi: 10.1093/eurheartj/ehl260. [DOI] [PubMed] [Google Scholar]
  • 11.Fox KM, Gerber RA, Bolinder B, Chen J, Kumar S. Prevalence of inadequate glycemic control among patients with type 2 diabetes in the United Kingdom general practice research database: a series of retrospective analyses of data from 1998 through 2002. Clinical Therapeutics. 2006;28(3):388–395. doi: 10.1016/j.clinthera.2006.03.005. [DOI] [PubMed] [Google Scholar]
  • 12.Knowler WC, Fowler SE, Hamman RF, et al. 10-year follow-up of diabetes incidence and weight loss in the diabetes prevention program outcomes study. The Lancet. 2009;374(9702):1677–1686. doi: 10.1016/S0140-6736(09)61457-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Giles TD. Prevention of type 2 diabetes mellitus to reduce cardiovascular morbidity and mortality: a review of the evidence. Journal of Clinical Hypertension. 2009;11(9):512–519. doi: 10.1111/j.1559-4572.2009.00064.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Cobble ME. Initiating and intensifying insulin therapy for type 2 diabetes: why, when, and how. American Journal of Therapeutics. 2009;16(1):56–64. doi: 10.1097/MJT.0b013e3181966bf0. [DOI] [PubMed] [Google Scholar]
  • 15.Hsu WC. Consequences of delaying progression to optimal therapy in patients with type 2 diabetes not achieving glycemic goals. Southern Medical Journal. 2009;102(1):67–76. doi: 10.1097/SMJ.0b013e318182d8a2. [DOI] [PubMed] [Google Scholar]
  • 16.Kerr D. Individualism and insulin pump therapy. Diabetologia. 2009;52(2):362–363. doi: 10.1007/s00125-008-1228-0. [DOI] [PubMed] [Google Scholar]
  • 17.Bell DSH. Insulin therapy in diabetes mellitus: how can the currently available injectable insulins be most prudently and efficaciously utilised? Drugs. 2007;67(13):1813–1827. doi: 10.2165/00003495-200767130-00002. [DOI] [PubMed] [Google Scholar]
  • 18.Sheldon B, Russell-Jones D, Wright J. Insulin analogues: an example of applied medical science. Diabetes, Obesity and Metabolism. 2009;11(1):5–19. doi: 10.1111/j.1463-1326.2008.01015.x. [DOI] [PubMed] [Google Scholar]
  • 19.Garg SK, Hirsch IB, Skyler JS. Insulin glargine and cancer-an unsubstantiated allegation. Diabetes Technology and Therapeutics. 2009;11(8):473–476. doi: 10.1089/dia.2009.1705. [DOI] [PubMed] [Google Scholar]
  • 20.Eckardt K, Eckel J. Insulin analogues: action profiles beyond glycaemic control. Archives Physiol Biochem. 2008;114(1):45–153. doi: 10.1080/13813450801983369. [DOI] [PubMed] [Google Scholar]
  • 21.Giugliano D, Ceriello A, Razzoli E, Esposito K. Defining the role of insulin lispro in the management of postprandial hyperglycaemia in patients with type 2 diabetes mellitus. Clinical Drug Investigation. 2008;28(4):199–210. doi: 10.2165/00044011-200828040-00001. [DOI] [PubMed] [Google Scholar]
  • 22.Chapman TM, Noble S, Goa KL. Spotlight on insulin aspart in type 1 and 2 diabetes mellitus. Treatments in Endocrinology. 2003;2(1):71–76. doi: 10.2165/00024677-200302010-00006. [DOI] [PubMed] [Google Scholar]
  • 23.Becker RHA. Insulin glulisine complementing basal insulins: a review of structure and activity. Diabetes Technology and Therapeutics. 2007;9(1):109–121. doi: 10.1089/dia.2006.0035. [DOI] [PubMed] [Google Scholar]
  • 24.Garnock-Jones KP, Plosker GL. Insulin glulisine: a review of its use in the management of diabetes mellitus. Drugs. 2009;69(8):1035–1057. doi: 10.2165/00003495-200969080-00006. [DOI] [PubMed] [Google Scholar]
  • 25.Hagenmeyer EG, Schädlich PK, Köster AD, Dippel F-W, Häussler B. Quality of life and treatment satisfaction in patients being treated with long-acting insulin analogues. Deutsche Medizinische Wochenschrift. 2009;134(12):565–570. doi: 10.1055/s-0029-1208087. [DOI] [PubMed] [Google Scholar]
  • 26.Elrishi MA, Jarvis J, Khunti K, Davies MJ. Insulin glargine and its role in glycaemic management of Type 2 diabetes. Expert Opinion on Drug Metabolism and Toxicology. 2008;4(8):1099–1110. doi: 10.1517/17425255.4.8.1099. [DOI] [PubMed] [Google Scholar]
  • 27.Morales J. Defining the role of insulin detemir in basal insulin therapy. Drugs. 2007;67(17):2557–2584. doi: 10.2165/00003495-200767170-00007. [DOI] [PubMed] [Google Scholar]
  • 28.Riddle MC, Rosenstock J, Gerich J. The treat-to-target trial: randomized addition of glargine or human NPH insulin to oral therapy of type 2 diabetic patients. Diabetes Care. 2003;26(11):3080–3086. doi: 10.2337/diacare.26.11.3080. [DOI] [PubMed] [Google Scholar]
  • 29.Gerstein HC, Yale J-F, Harris SB, Issa M, Stewart JA, Dempsey E. A randomized trial of adding insulin glargine vs. avoidance of insulin in people with Type 2 diabetes on either no oral glucose-lowering agents or submaximal doses of metformin and/or sulphonylureas. The Canadian INSIGHT (implementing new strategies with Insulin glargine for hyperglycaemia treatment) Study. Diabetic Medicine. 2006;23(7):736–742. doi: 10.1111/j.1464-5491.2006.01881.x. [DOI] [PubMed] [Google Scholar]
  • 30.Rosenstock J, Sugimoto D, Strange P, Stewart JA, Soltes-Rak E, Dailey G. Triple therapy in type 2 diabetes: insulin glargine or rosiglitazone added to combination therapy of sulfonylurea plus metformin in insulin-naive patients. Diabetes Care. 2006;29(3):554–559. doi: 10.2337/diacare.29.03.06.dc05-0695. [DOI] [PubMed] [Google Scholar]
  • 31.Horvath K, Jeitler K, Berghold A, Ebrahim SH. Long-acting insulin analogues versus NPH insulin (human isophane insulin) for type 2 diabetes mellitus. Cochrane Database of Systematic Reviews. 2007;18(2) doi: 10.1002/14651858.CD005613.pub3. Article ID CD005613. [DOI] [PubMed] [Google Scholar]
  • 32.Qayyum R, Bolen S, Maruthur N, et al. Systematic review: comparative effectiveness and safety of premixed insulin analogues in type 2 diabetes. Annals of Internal Medicine. 2008;149(8):549–559. doi: 10.7326/0003-4819-149-8-200810210-00242. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Gough SCL. A review of human and analogue insulin trials. Diabetes Research and Clinical Practice. 2007;77(1):1–15. doi: 10.1016/j.diabres.2006.10.015. [DOI] [PubMed] [Google Scholar]
  • 34.Shamoon H, Duffy H, Fleischer N, et al. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. New England Journal of Medicine. 1993;329(14):977–986. doi: 10.1056/NEJM199309303291401. [DOI] [PubMed] [Google Scholar]
  • 35.Chase HP, Lockspeiser T, Peery B, et al. The impact of the diabetes control and complications trial and humalog insulin on glycohemoglobin levels and severe hypoglycemia in type 1 diabetes. Diabetes Care. 2001;24(3):430–434. doi: 10.2337/diacare.24.3.430. [DOI] [PubMed] [Google Scholar]
  • 36.Monami M, Marchionni N, Mannucci E. Long-acting insulin analogues vs. NPH human insulin in type 1 diabetes. A meta-analysis. Diabetes, Obesity and Metabolism. 2009;11(4):372–378. doi: 10.1111/j.1463-1326.2008.00976.x. [DOI] [PubMed] [Google Scholar]
  • 37.Meneghini L. Demonstrating strategies for initiation of insulin therapy: matching the right insulin to the right patient. International Journal of Clinical Practice. 2008;62(8):1255–1264. doi: 10.1111/j.1742-1241.2008.01816.x. [DOI] [PubMed] [Google Scholar]
  • 38.Pi-Sunyer FX. The effects of pharmacologic agents for type 2 diabetes mellitus on body weight. Postgraduate Medicine. 2008;120(2):5–17. doi: 10.3810/pgm.2008.07.1785. [DOI] [PubMed] [Google Scholar]
  • 39.Bush MA. Intensive diabetes therapy and body weight: focus on insulin detemir. Endocrinology and Metabolism Clinics of North America. 2007;36(supplement 1):33–44. doi: 10.1016/s0889-8529(07)80006-5. [DOI] [PubMed] [Google Scholar]
  • 40.Dornhorst A, Lüddeke H-J, Koenen C, et al. Transferring to insulin detemir from NPH insulin or insulin glargine in type 2 diabetes patients on basal-only therapy with oral antidiabetic drugs improves glycaemic control and reduces weight gain and risk of hypoglycaemia: 14-week follow-up data from PREDICTIVE. Diabetes, Obesity and Metabolism. 2008;10(1):75–81. doi: 10.1111/j.1463-1326.2007.00816.x. [DOI] [PubMed] [Google Scholar]
  • 41.Hartman I. Insulin analogs: impact on treatment success, satisfaction, quality of life, and adherence. Clinical Medicine and Research. 2008;6(2):54–67. doi: 10.3121/cmr.2008.793. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Scheiner G, Sobel RJ, Smith DE, et al. Insulin pump therapy guidelines for successful outcomes. Diabetes Educator. 2009;35(supplement 2):29S–41S. doi: 10.1177/0145721709333493. [DOI] [PubMed] [Google Scholar]
  • 43.Hanaire H, Lassmann-Vague V, Jeandidier N, et al. Treatment of diabetes mellitus using an external insulin pump: the state of the art. Diabetes and Metabolism. 2008;34(4, supplement 1):401–423. doi: 10.1016/S1262-3636(08)73972-7. [DOI] [PubMed] [Google Scholar]
  • 44.Sherr J, Tamborlane WV. Past, present, and future of insulin pump therapy: better shot at diabetes control. Mount Sinai Journal of Medicine. 2008;75(4):352–361. doi: 10.1002/msj.20055. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Potti LG, Haines ST. Continuous subcutaneous insulin infusion therapy: a primer on insulin pumps. Journal of the American Pharmacists Association. 2009;49(1):1–13. doi: 10.1331/JAphA.2009.08122. [DOI] [PubMed] [Google Scholar]
  • 46.White RD. Insulin pump therapy (continuous subcutaneous insulin infusion) Primary Care. 2007;34(4):845–871. doi: 10.1016/j.pop.2007.07.005. [DOI] [PubMed] [Google Scholar]
  • 47.Liberatore RDR, Damiani D. Insulin pump therapy in type 1 diabetes mellitus. Jornal de Pediatria. 2006;82(4):249–254. doi: 10.2223/JPED.1507. [DOI] [PubMed] [Google Scholar]
  • 48.Ulahannan T, Myint NN, Lonnen KF. Making the case for insulin pump therapy. Practical Diabetes International. 2007;24(5):252–256. [Google Scholar]
  • 49.Jeandidier N, Rivelineb J-P, Tubiana-Rufi N, et al. Treatment of diabetes mellitus using an external insulin pump in clinical practice. Diabetes and Metabolism. 2008;34(4, supplement 1):425–438. doi: 10.1016/S1262-3636(08)73973-9. [DOI] [PubMed] [Google Scholar]
  • 50.Siddiqui N, Rahman S, Nessa A. Development of insulin delivery systems. Mymensingh Medical Journal. 2008;17(1):102–110. [PubMed] [Google Scholar]
  • 51.Shamoon H, Duffy H, Fleischer N, et al. Implementation of treatment protocols in the diabetes control and complications trial. Diabetes Care. 1995;18(3):361–376. doi: 10.2337/diacare.18.3.361. [DOI] [PubMed] [Google Scholar]
  • 52.Pickup J, Mattock M, Kerry S. Glycemic control with continuous subcutaneous insulin infusion compared with intensive insulin injections in patients with type 1 diabetes: meta-analysis of randomized controlled trials. British Medical Journal. 2002;324:705–708. doi: 10.1136/bmj.324.7339.705. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Weissberg-Benchell J, Antisdel-Lomaglio J, Seshadri R. Insulin pump therapy: a meta-analysis. Diabetes Care. 2003;26(4):1079–1087. doi: 10.2337/diacare.26.4.1079. [DOI] [PubMed] [Google Scholar]
  • 54.Barnard KD, Lloyd CE, Skinner TC. Systematic literature review: quality of life associated with insulin pump use in type 1 diabetes. Diabetic Medicine. 2007;24(6):607–617. doi: 10.1111/j.1464-5491.2007.02120.x. [DOI] [PubMed] [Google Scholar]
  • 55.Colquitt J, Royle P, Waugh N. Are analogue insulins better than soluble in continuous subcutaneous insulin infusion? Results of a meta-analysis. Diabetic Medicine. 2003;20(10):863–866. doi: 10.1046/j.1464-5491.2003.01018.x. [DOI] [PubMed] [Google Scholar]
  • 56.Retnakaran R, Hochman J, DeVries JH, et al. Continuous subcutaneous insulin infusion versus multiple daily injections. The impact of baseline A1c . Diabetes Care. 2004;27(11):2590–2596. doi: 10.2337/diacare.27.11.2590. [DOI] [PubMed] [Google Scholar]
  • 57.Retnakaran R, DeVries JH, Hanaire-Broutin H, Heine RJ, Melki V, Zinman B. Continuous subcutaneous insulin infusion versus multiple daily injections. Modeling predicted benefits in relationship to baseline A1c . Diabetes Care. 2005;28(7):1835–1836. doi: 10.2337/diacare.28.7.1835. [DOI] [PubMed] [Google Scholar]
  • 58.Hoogma RPLM, Hammond PJ, Gomis R, et al. Comparison of the effects of continuous subcutaneous insulin infusion (CSII) and NPH-based multiple daily insulin injections (MDI) on glycaemic control and quality of life. Results of the 5-nations trial. Diabetic Medicine. 2006;23(2):141–147. doi: 10.1111/j.1464-5491.2005.01738.x. [DOI] [PubMed] [Google Scholar]
  • 59.Bolli B, Capani F, Home P, et al. Comparison of a multiple daily injection daily with once-daily insulin glargine basal insulin and mealtime lispro, to continuous subcutaneous insulin infusion: a randomised, open, parallel study. Diabetes. 2004;53(supplement 2):A107–A108. [Google Scholar]
  • 60.Doyle EA, Weinzimer SA, Steffen AT, Ahern JAH, Vincent M, Tamborlane WV. A randomized, prospective trial comparing the efficacy of continuous subcutaneous insulin infusion with multiple daily injections using insulin glargine. Diabetes Care. 2004;27(7):1554–1558. doi: 10.2337/diacare.27.7.1554. [DOI] [PubMed] [Google Scholar]
  • 61.Hirsch B, Bode B, Garg S, et al. Continuous subcutaneous insulin infusion (CSII) of insulin aspart versus multiple daily injection of insulin aspart/insulin glargine in type 1 diabetic patients previously treated with CSII. Diabetes Care. 2005;28:533–538. doi: 10.2337/diacare.28.3.533. [DOI] [PubMed] [Google Scholar]
  • 62.Fahlén M, Eliasson B, Oden A. Optimization of basal insulin delivery in type 1 diabetes: a retrospective study on the use of continuous subcutaneous insulin infusion and insulin glargine. Diabetic Medicine. 2005;22(4):382–386. doi: 10.1111/j.1464-5491.2004.01444.x. [DOI] [PubMed] [Google Scholar]
  • 63.Aberle I, Zimprich D, Bach-Kliegel B, et al. Continuous subcutaneous insulin infusion leads to immediate, stable and long-term changes in metabolic control. Diabetes, Obesity and Metabolism. 2008;10(4):329–335. doi: 10.1111/j.1463-1326.2007.00707.x. [DOI] [PubMed] [Google Scholar]
  • 64.Tamborlane WV, Swan K, Sikes KA, Steffen AT, Weinzimer SA. The renaissance of insulin pump treatment in childhood type 1 diabetes. Reviews in Endocrine and Metabolic Disorders. 2006;7(3):205–213. doi: 10.1007/s11154-006-9018-9. [DOI] [PubMed] [Google Scholar]
  • 65.Weinzimer SA, Ahern JH, Doyle EA, et al. Persistence of benefits of continuous subcutaneous insulin infusion in very young children with type 1 diabetes: a follow-up report. Pediatrics. 2004;114(6):1601–1605. doi: 10.1542/peds.2004-0092. [DOI] [PubMed] [Google Scholar]
  • 66.Sulli N, Shashaj B. Long-term benefits of continuous subcutaneous insulin infusion in children with type 1 diabetes: a 4-year follow-up. Diabetic Medicine. 2006;23(8):900–906. doi: 10.1111/j.1464-5491.2006.01935.x. [DOI] [PubMed] [Google Scholar]
  • 67.Jakisch BI, Wagner VM, Heidtmann B, et al. Comparison of continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI) in paediatric type 1 diabetes: a multicentre matched-pair cohort analysis over 3 years. Diabetic Medicine. 2008;25(1):80–85. doi: 10.1111/j.1464-5491.2007.02311.x. [DOI] [PubMed] [Google Scholar]
  • 68.Weinzimer SA, Ternand C, Howard C, Chang C-T, Becker DJ, Laffel LMB. A randomized trial comparing continuous subcutaneous insulin infusion of insulin aspart versus insulin lispro in children and adolescents with type 1 diabetes. Diabetes Care. 2008;31(2):210–215. doi: 10.2337/dc07-1378. [DOI] [PubMed] [Google Scholar]
  • 69.Pickup JC, Sutton AJ. Severe hypoglycaemia and glycaemic control in Type 1 diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion. Diabetic Medicine. 2008;25(7):765–774. doi: 10.1111/j.1464-5491.2008.02486.x. [DOI] [PubMed] [Google Scholar]
  • 70.McVean JJF, Eickhoff JC, MacDonald MJ. Factors correlating with improved A1C in children using continuous subcutaneous insulin infusion. Diabetes Care. 2007;30(10):2499–2500. doi: 10.2337/dc07-0614. [DOI] [PubMed] [Google Scholar]
  • 71.Hanas R, Ludvigsson J. Hypoglycemia and ketoacidosis with insulin pump therapy in children and adolescents. Pediatric Diabetes. 2006;7(supplement 4):32–38. doi: 10.1111/j.1399-543X.2006.00169.x. [DOI] [PubMed] [Google Scholar]
  • 72.McMahon SK, Airey FL, Marangou DA, et al. Insulin pump therapy in children and adolescents: improvements in key parameters of diabetes management including quality of life. Diabetic Medicine. 2005;22(1):92–96. doi: 10.1111/j.1464-5491.2004.01359.x. [DOI] [PubMed] [Google Scholar]
  • 73.Júlíusson PB, Graue M, Wentzel-Larsen T. The impact of continuous subcutaneous insulin infusion on health-related quality of life in children and adolescents with type 1 diabetes. Acta Paediatrica. 2006;95(11):1481–1487. doi: 10.1080/08035250600774114. [DOI] [PubMed] [Google Scholar]
  • 74.Opipari-arrigan L, Fredericks EM, Burkhart N, Dale L, Hodge M, Foster C. Continuous subcutaneous insulin infusion benefits quality of life in preschool-age children with type 1 diabetes mellitus. Pediatric Diabetes. 2007;8(6):377–383. doi: 10.1111/j.1399-5448.2007.00283.x. [DOI] [PubMed] [Google Scholar]
  • 75.Barnard KD, Speight J, Skinner TC. Quality of life and impact of continuous subcutaneous insulin infusion for children and their parents. Practical Diabetes International. 2008;25(7):278–284. [Google Scholar]
  • 76.Rackham O, Paize F, Weindling AM. Cause of death in infants of women with pregestational diabetes mellitus and the relationship with glycemic control. Postgraduate Medicine. 2009;121(4):26–32. doi: 10.3810/pgm.2009.07.2026. [DOI] [PubMed] [Google Scholar]
  • 77.Hieronimus S, Cupelli C, Bongain A, Durand-Rèville M, Berthier F, Fènichel P. Pregnancy in type 1 diabetes: insulin pump versus intensified conventional therapy. Gynecologie Obstetrique Fertilite. 2005;33(6):389–394. doi: 10.1016/j.gyobfe.2005.04.020. [DOI] [PubMed] [Google Scholar]
  • 78.Gabbe SG, Holing E, Temple P, Brown ZA. Benefits, risks, costs, and patient satisfaction associated with insulin pump therapy for the pregnancy complicated by type 1 diabetes mellitus. American Journal of Obstetrics and Gynecology. 2000;182(6):1283–1291. doi: 10.1067/mob.2000.106182. [DOI] [PubMed] [Google Scholar]
  • 79.Gestational Diabetes Mellitus. American diabetes association publication. Diabetes Care. 2003;26(supplement 1):S103–S105. doi: 10.2337/diacare.26.2007.s103. [DOI] [PubMed] [Google Scholar]
  • 80.Chitayat L, Jovanovic L, Hod M. New modalities in the treatment of pregnancies complicated by diabetes: drugs and devices. Seminars in Fetal and Neonatal Medicine. 2009;14(2):72–76. doi: 10.1016/j.siny.2008.09.001. [DOI] [PubMed] [Google Scholar]
  • 81.Mukhopadhyay A, Farrell T, Fraser RB, Ola B. Continuous subcutaneous insulin infusion vs intensive conventional insulin therapy in pregnant diabetic women: a systematic review and metaanalysis of randomized, controlled trials. American Journal of Obstetrics and Gynecology. 2007;197(5):447–456. doi: 10.1016/j.ajog.2007.03.062. [DOI] [PubMed] [Google Scholar]
  • 82.Farrar D, Tuffnell DJ, West J. Continuous subcutaneous insulin infusion versus multiple daily injections of insulin for pregnant women with diabetes. Cochrane Database of Systematic Reviews. 2007;18(3) doi: 10.1002/14651858.CD005542.pub2. Article ID CD005542. [DOI] [PubMed] [Google Scholar]
  • 83.St John A, Davis WA, Price CP, Davis TME. The value of self-monitoring of blood glucose: a review of recent evidence. Journal of Diabetes and Its Complications. 2010;24(2):129–141. doi: 10.1016/j.jdiacomp.2009.01.002. [DOI] [PubMed] [Google Scholar]
  • 84.Kohnert KD, Vogt L, Augstein P, et al. Relationships between glucose variability and conventional measures of glycemic control in continuously monitored patients with type 2 diabetes. Hormone and Metabolic Research. 2009;41(2):137–141. doi: 10.1055/s-0028-1128143. [DOI] [PubMed] [Google Scholar]
  • 85.Reach G, Choleau C. Continuous glucose monitoring: physiological and technological challenges. Current Diabetes Reviews. 2008;4(3):175–180. doi: 10.2174/157339908785294488. [DOI] [PubMed] [Google Scholar]
  • 86.De Block C, Manuel-y-Keenoy B, Rogiers P, Jorens P, Van Gaal L. Glucose control and use of continuous glucose monitoring in the intensive care unit: a critical review. Current Diabetes Reviews. 2008;4(3):234–244. doi: 10.2174/157339908785294460. [DOI] [PubMed] [Google Scholar]
  • 87.Battelino T, Bolinder J. Clinical use of real-time continuous glucose monitoring. Current Diabetes Reviews. 2008;4(3):218–222. doi: 10.2174/157339908785294352. [DOI] [PubMed] [Google Scholar]
  • 88.Ellis SL, Naik RG, Gemperline K, Garg SK. Use of continuous glucose monitoring in patients with type 1 diabetes. Current Diabetes Reviews. 2008;4(3):207–217. doi: 10.2174/157339908785294370. [DOI] [PubMed] [Google Scholar]
  • 89.Hovorka R. Continuous glucose monitoring and closed-loop systems. Diabetic Medicine. 2006;23(1):1–12. doi: 10.1111/j.1464-5491.2005.01672.x. [DOI] [PubMed] [Google Scholar]
  • 90.Hanaire H. Continuous glucose monitoring and external insulin pump: towards a subcutaneous closed loop. Diabetes and Metabolism. 2006;32(5):534–538. doi: 10.1016/s1262-3636(06)72808-7. [DOI] [PubMed] [Google Scholar]
  • 91.Hirsch IB, Armstrong D, Bergenstal RM, et al. Clinical application of emerging sensor technologies in diabetes management: consensus guidelines for continuous glucose monitoring (CGM) Diabetes Technology and Therapeutics. 2008;10(4):232–246. doi: 10.1089/dia.2008.0016. [DOI] [PubMed] [Google Scholar]
  • 92.Sparacino G, Facchinetti A, Maran A, Cobelli C. Continuous glucose monitoring time series and hypo/hyperglycemia prevention: requirements, methods, open problems. Current Diabetes Reviews. 2008;4(3):181–192. doi: 10.2174/157339908785294361. [DOI] [PubMed] [Google Scholar]
  • 93.Danne T, Lange K, Kordonouri O. Real-time glucose sensors in children and adolescents with type-1 diabetes. Hormone Research. 2008;70(4):193–202. doi: 10.1159/000151592. [DOI] [PubMed] [Google Scholar]
  • 94.Grant P. A new approach to diabetic control: fuzzy logic and insulin pump technology. Medical Engineering and Physics. 2007;29(7):824–827. doi: 10.1016/j.medengphy.2006.08.014. [DOI] [PubMed] [Google Scholar]
  • 95.Steil GM, Rebrin K, Darwin C, Hariri F, Saad MF. Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes. 2006;55(12):3344–3350. doi: 10.2337/db06-0419. [DOI] [PubMed] [Google Scholar]
  • 96.Weinzimer SA, Steil GM, Swan KL, Dziura J, Kurtz N, Tamborlane WV. Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care. 2008;31(5):934–939. doi: 10.2337/dc07-1967. [DOI] [PubMed] [Google Scholar]
  • 97.Bequette BW. A critical assessment of algorithms and challenges in the development of a closed-loop artificial pancreas. Diabetes Technology and Therapeutics. 2005;7(1):28–47. doi: 10.1089/dia.2005.7.28. [DOI] [PubMed] [Google Scholar]
  • 98.Silva AI, Norton De Matos A, Brons IG, Mateus M. An overview on the development of a bio-artificial pancreas as a treatment of insulin-dependent diabetes mellitus. Medicinal Research Reviews. 2006;26(2):181–222. doi: 10.1002/med.20047. [DOI] [PubMed] [Google Scholar]
  • 99.Thorens B. Development and preclinical assessment of a bioartificial pancreas. Swiss Medical Weekly. 2007;137(supplement 155):68S–71S. [PubMed] [Google Scholar]
  • 100.Renard E, Costalat G, Chevassus H, Bringer J. Artificial β-cell: clinical experience toward an implantable closed-loop insulin delivery system. Diabetes and Metabolism. 2006;32(5):497–502. doi: 10.1016/s1262-3636(06)72802-6. [DOI] [PubMed] [Google Scholar]
  • 101.Erdin N, Robin F, Heinemann L, Brandt D, Hovorka R. Further development of artificial pancreas: blocked by patents? Journal of Diabetes Science and Technology. 2008;2(6):971–976. doi: 10.1177/193229680800200607. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 102.Kobayashi N. Bioartificial pancreas for the treatment of diabetes. Cell Transplantation. 2008;17(1-2):11–17. doi: 10.3727/000000008783907107. [DOI] [PubMed] [Google Scholar]

Articles from Experimental Diabetes Research are provided here courtesy of Wiley

RESOURCES