Skip to main content
Cardiovascular Diseases logoLink to Cardiovascular Diseases
. 1978 Dec;5(4):354–359.

COMPARISON OF TWO SUTURE TECHNIQUES AND MATERIALS: RELATIONSHIP TO PERIVALVULAR LEAKS AFTER CARDIAC VALVE REPLACEMENT

Christoph Beddermann 1, Hans G Borst 1
PMCID: PMC287749  PMID: 15216039

Full text

PDF
354

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Cleland J. A universally applicable continuous suture technique for insertion of aortic valve prostheses. Ann Thorac Surg. 1975 Jun;19(6):719–724. doi: 10.1016/s0003-4975(10)63836-2. [DOI] [PubMed] [Google Scholar]
  2. Favaloro R. G., Effler D. B., Groves L. K., Suarez E., Shirey E. K. Surgical repair of leaking prosthetic heart valves. Ann Thorac Surg. 1967 Jun;3(6):503–513. doi: 10.1016/s0003-4975(10)66459-4. [DOI] [PubMed] [Google Scholar]
  3. Fishman N. H., Hutchinson J. C., Roe B. B. Prevention of prosthetic cardiac valve detachment. Surgery. 1970 May;67(5):867–873. [PubMed] [Google Scholar]
  4. Kastor J. A., Akbarian M., Buckley M. J., Dinsmore R. E., Sanders C. A., Scannell J. G., Austen W. G. Paravalvular leaks and hemolytic anemia following insertion of Starr-Edwards aortic and mitral valves. J Thorac Cardiovasc Surg. 1968 Aug;56(2):279–288. [PubMed] [Google Scholar]
  5. Leachman R. D., Cokkinos D. V. Absence of opening click in dehiscence of mitral-valve prosthesis. N Engl J Med. 1969 Aug 28;281(9):461–464. doi: 10.1056/NEJM196908282810902. [DOI] [PubMed] [Google Scholar]
  6. Messmer B. J., Hallman G. L., Liotta D., Martin C., Cooley D. A. Aortic valve replacement: new techniques, hydrodynamics, and clinical results. Surgery. 1970 Dec;68(6):1026–1037. [PubMed] [Google Scholar]
  7. Messmer B. J., Okies J. E., Hallman G. L., Cooley D. A. Aortic valve replacement: two years' experience with the Björk-Shiley tilting-disc prosthesis. Surgery. 1972 Nov;72(5):772–779. [PubMed] [Google Scholar]
  8. Messmer B. J., Okies J. E., Hallman G. L., Cooley D. A. Mitral valve replacement with the Björk-Shiley tilting-disc prosthesis. J Thorac Cardiovasc Surg. 1971 Dec;62(6):938–946. [PubMed] [Google Scholar]
  9. Pellegrini A., Marcazzan E., Peronace B., De Gasperis C., Gordini V., Mombelloni G. Ten years' experience in heart valve replacement with artificial prostheses: immediate and long-term results in 1812 cases. J Cardiovasc Surg (Torino) 1975 Nov-Dec;16(6):612–625. [PubMed] [Google Scholar]
  10. Sandza J. G., Jr, Clark R. E., Ferguson T. B., Connors J. P., Weldon C. S. Replacement of prosthetic heart valves. A fifteen-year experience. J Thorac Cardiovasc Surg. 1977 Dec;74(6):864–874. [PubMed] [Google Scholar]
  11. Wada J. The knotless suture method for prosthetic valve fixation. Int Surg. 1966 Oct;46(4):317–320. [PubMed] [Google Scholar]
  12. Weldon C. S., Ferguson T. B. The elimination of periprosthetic leaks as a complication of mitral valve replacement. Ann Thorac Surg. 1974 Nov;18(5):447–455. doi: 10.1016/s0003-4975(10)64385-8. [DOI] [PubMed] [Google Scholar]

Articles from Cardiovascular Diseases are provided here courtesy of Texas Heart Institute