SEQUENTIAL HEMODYNAMIC STUDIES OF THE IONESCU-SHILEY PERICARDIAL XENOGRAFT VALVE UP TO SIX YEARS AFTER IMPLANTATION

Anand P Tandon 1, Donald R Smith 1, Marian I Ionescu 1
PMCID: PMC287795  PMID: 15216303

Abstract

Sequential hemodynamic studies consisting of one preoperative and three postoperative cardiac catheterizations were undertaken in 19 patients at approximately 1, 4, and 6 years after valve replacement. Thirteen patients had aortic and six patients had mitral pericardial xenograft valves. Significant improvement was noted in various hemodynamic parameters in both groups of patients at the postoperative studies as compared to the preoperative findings. In patients with aortic valve replacement, the peak systolic gradient was 7.0 ± 1.2 mm Hg at rest, and 10.0 ± 1.6 mm Hg after exercise during the third postoperative study. The calculated xenograft orifice areas were 1.6 ± 0.1 cm2 at rest and 2.1 ± 0.2 cm2 after exercise in the aortic group, and 2.2 ± 0.2 cm2 at rest and 2.7 ± 0.2 cm2 after exercise in the mitral group at the third postoperative investigation. No significant change was noted among the three postoperative studies in the hemodynamic parameters. The results confirm the maintenance of functional performance of the Ionescu-Shiley pericardial xenograft up to 73 months after valve replacement.

Full text

PDF
271

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Björk V. O., Bök K., Holmgren A. The Björk-Shiley mitral valve prosthesis. A comparative study with different prosthesis orientations. Ann Thorac Surg. 1974 Oct;18(4):379–390. doi: 10.1016/s0003-4975(10)64375-5. [DOI] [PubMed] [Google Scholar]
  2. Björk V. O., Holmgren A., Olin C., Ovenfors C. O. Clinical and haemodynamic results of aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis. Scand J Thorac Cardiovasc Surg. 1971;5(3):177–191. [PubMed] [Google Scholar]
  3. Bristow J. D., Kremkau E. L. Hemodynamic changes after valve replacement with Starr-Edwards prostheses. Am J Cardiol. 1975 May;35(5):716–724. doi: 10.1016/0002-9149(75)90064-8. [DOI] [PubMed] [Google Scholar]
  4. GORLIN R., GORLIN S. G. Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I. Am Heart J. 1951 Jan;41(1):1–29. doi: 10.1016/0002-8703(51)90002-6. [DOI] [PubMed] [Google Scholar]
  5. Gabbay S., McQueen D. M., Yellin E. L., Becker R. M., Frater R. W. In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates. J Thorac Cardiovasc Surg. 1978 Dec;76(6):771–787. [PubMed] [Google Scholar]
  6. Hultgren H., Hubis H., Shumway N. Cardiac function following mitral valve replacement. Am Heart J. 1968 Mar;75(3):302–312. doi: 10.1016/0002-8703(68)90086-0. [DOI] [PubMed] [Google Scholar]
  7. Ionescu M. I., Tandon A. P. Long term clinical and haemodynamic evaluation of the Ionescu-Shiley pericardial xenograft heart valve. Thoraxchir Vask Chir. 1978 Aug;26(4):250–258. doi: 10.1055/s-0028-1096633. [DOI] [PubMed] [Google Scholar]
  8. Ionescu M. I., Tandon A. P., Mary D. A., Abid A. Heart valve replacement with the Ionescu-Shiley pericardial xenograft. J Thorac Cardiovasc Surg. 1977 Jan;73(1):31–42. [PubMed] [Google Scholar]
  9. Pietras R. J., Long D. M., Rosen K. M. Late postoperative clinical and hemodynamic assessment of the early cloth-covered Starr-Edwards mitral valve prosthesis. J Thorac Cardiovasc Surg. 1974 Mar;67(3):450–458. [PubMed] [Google Scholar]
  10. Sigwart U., Schmidt H., Gleichmann U., Borst H. G. In vivo evaluation of the Lillehei-Kaster heart valve prosthesis. Ann Thorac Surg. 1976 Sep;22(3):213–220. doi: 10.1016/s0003-4975(10)64905-3. [DOI] [PubMed] [Google Scholar]
  11. Tandon A. P., Smith D. R., Ionescu M. I. Hemodynamic evaluation of the Ionescu-Shiley pericardial xenograft in the mitral position. Am Heart J. 1978 May;95(5):595–601. doi: 10.1016/0002-8703(78)90301-0. [DOI] [PubMed] [Google Scholar]
  12. Tandon A. P., Smith D. R., Whitaker W., Ionescu M. I. Long-term haemodynamic evaluation of aortic pericardial xenograft. Br Heart J. 1978 Jun;40(6):602–607. doi: 10.1136/hrt.40.6.602. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Cardiovascular Diseases are provided here courtesy of Texas Heart Institute

RESOURCES