Skip to main content
Springer logoLink to Springer
letter
. 2010 May 26;37(7):1436–1437. doi: 10.1007/s00259-010-1476-3

Reply to: The diagnostic accuracy of 18F-FDG PET in cutaneous malignant melanoma

Roberto C Delgado-Bolton 1,, Felisa Jiménez-Requena 2, Cristina Fernández-Pérez 3, Sanjiv S Gambhir 4, Judy Schwimmer 5, José M Pérez-Vázquez 2, José L Carreras-Delgado 1
PMCID: PMC2886141  PMID: 19727717

Dear Sir,

Following the publication of our study entitled “Meta-analysis of the performance of 18F-FDG PET in cutaneous melanoma” in the February 2010 issue [1], we reply to the comments presented in the above letter to the editor.

First, as described in the “Materials and methods” section, we performed a systematic search of the literature to identify relevant studies published between January 2000 and January 2006. Then, the meta-analysis was performed and the manuscript was prepared for publication. Finally, it was accepted for publication in 2009. Because of this 3-year delay between the literature search and publication, studies published after January 2006 were not included. The delay between the presentation of results as abstracts and full publication of results has been previously studied in the meta-analysis published by Scherer et al. [2]. In this meta-analysis, most studies were published in full within 2 years of their appearance as abstracts, although some studies presented a delay of up to 3 years. However, the results of our meta-analysis may be updated to include the most recent studies.

Second, the methodological quality criteria applied in our meta-analysis had been developed and applied in previous meta-analyses by Huebner et al. [3], Gould et al. [4], Delgado-Bolton et al. [5] and Schwimmer et al. [6]. These methodological quality criteria were developed to systematically analyse studies focusing on the performance of 18F-FDG PET. They apply 7 guidelines which include 38 items, in order to extensively evaluate the methodological quality of the studies and, also, establish guidelines for carrying out methodologically rigorous studies. These criteria are based on evidence-based medicine criteria and, to the best of our knowledge, are not biased. Regarding the quality assessment of studies of diagnostic accuracy included in systematic reviews (QUADAS) criteria [7, 8], which is a 14-item instrument, it can be useful for the assessment of diagnostic accuracy studies and, if used extensively, it will facilitate comparison among meta-analyses. However, the QUADAS tool has not been designed specifically for 18F-FDG PET. As evidenced in the meta-analysis by Kwee et al. [9], the QUADAS criteria present certain limitations when analysing 18F-FDG PET diagnostic accuracy studies. These authors eliminated 3 of the 14 criteria and added another different one. This indicates that the QUADAS criteria may not be the optimal tool for evaluating the methodological quality in 18F-FDG PET studies. Furthermore, the methodological quality criteria applied in our meta-analysis include certain guidelines and items not analysed or incomplete in the QUADAS criteria, such as: description of study design and patient selection criteria, characteristics of patient population finally studied, sensitivity and specificity data, and change in management information. These additional aspects not included in the QUADAS criteria can be of relevance when assessing the methodological quality and establishing guidelines for performing methodologically rigorous studies on 18F-FDG PET.

Third, regarding the end-points chosen for our meta-analysis, it would have been very interesting to analyse the diagnostic performance of 18F-FDG PET depending on the American Joint Committee on Cancer (AJCC) stage. Unfortunately, most of the original papers did not supply enough information on the AJCC stage of the patients included. Many studies included heterogeneous populations regarding the AJCC stage and the results of the 18F-FDG PET were not presented independently for each AJCC stage. Therefore, it was not possible to study this end-point. If future studies include enough details of population characteristics and present the results of sensitivity and specificity for each subgroup of patients, it will be possible to analyse this end-point in a meta-analysis.

Fourth, in our meta-analysis the quantitative analysis evaluated subgroups of studies that presented the same method of counting findings (patients, lesions, basins, etc.). We separately analysed like data (patients, lesions, basins, lymph nodes, areas or scans), because we considered the results of studies that referred to different data (patients, lesions, basins, etc.) not comparable. Because of this, the pooled data were reduced. However, we considered it methodologically more rigorous than pooling together different data.

Finally, we agree with the comment regarding the need for standardization in the reporting of studies to improve the information provided by each individual study, which will allow future meta-analyses and cost-effectiveness analyses to establish the role of 18F-FDG PET.

Acknowledgments

Open Access

This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

Footnotes

This reply refers to the letter to the editor at http://dx.doi.org/10.1007/s00259-010-1475-4

References

  • 1.Jiménez-Requena F, Delgado-Bolton RC, Fernández-Pérez C, Gambhir SS, Schwimmer J, Pérez-Vázquez JM, et al. Meta-analysis of the performance of (18)F-FDG PET in cutaneous melanoma. Eur J Nucl Med Mol Imaging. 2010;37:284–300. doi: 10.1007/s00259-009-1224-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Scherer RW, Dickersin K, Langenberg P. Full publication of results initially presented in abstracts. A meta-analysis. JAMA. 1994;272:158–162. doi: 10.1001/jama.272.2.158. [DOI] [PubMed] [Google Scholar]
  • 3.Huebner RH, Park KC, Shepherd JE, Schwimmer J, Czernin J, Phelps ME, et al. A meta-analysis of the literature for whole-body FDG PET detection of recurrent colorectal cancer. J Nucl Med. 2000;41:1177–1189. [PubMed] [Google Scholar]
  • 4.Gould MK, Maclean CC, Kuschner WG, Rydzak CE, Owens DK. Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions: a meta-analysis. JAMA. 2001;285:914–924. doi: 10.1001/jama.285.7.914. [DOI] [PubMed] [Google Scholar]
  • 5.Delgado-Bolton RC, Fernández-Pérez C, González-Maté A, Carreras JL. Meta-analysis of the performance of 18F-FDG PET in primary tumor detection in unknown primary tumors. J Nucl Med. 2003;44:1301–1314. [PubMed] [Google Scholar]
  • 6.Schwimmer J, Essner R, Patel A, Jahan SA, Shepherd JE, Park K, et al. A review of the literature for whole-body FDG PET in the management of patients with melanoma. Q J Nucl Med. 2000;44:153–167. [PubMed] [Google Scholar]
  • 7.Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol. 2003;3:25. doi: 10.1186/1471-2288-3-25. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Whiting PF, Weswood ME, Rutjes AW, Reitsma JB, Bossuyt PN, Kleijnen J. Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies. BMC Med Res Methodol. 2006;6:9. doi: 10.1186/1471-2288-6-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Kwee TC, Kwee RM. Combined FDG-PET/CT for the detection of unknown primary tumors: systematic review and meta-analysis. Eur Radiol. 2009;19:731–744. doi: 10.1007/s00330-008-1194-4. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from European Journal of Nuclear Medicine and Molecular Imaging are provided here courtesy of Springer

RESOURCES