Abstract
Membrane filter adsorption-elution is an efficient method for concentration and partial purification of several types of viruses from various aqueous solutions. For efficient virus adsorption to negatively charged filters, the sample is adjusted to pH 3.5 and trivalent salts are added before filtration. Since influenza virus is sensitive to extremes in pH, it cannot be concentrated by ordinary filters. Zeta Plus filters, which have a net positive charge of up to 5 or 6, were evaluated for the concentration of influenza virus from infectious allantoic fluids. Influenza virus efficiently adsorbed to Zeta Plus filters at pH 6, and addition of salts was not necessary. Adsorbed virus was eluted in a small volume of 2% bovine serum albumin plus 1 M NaCl at pH 10. By this procedure, viruses in 100 ml of allantoic fluid were concentrated to a final volume of 8 ml, with an average recovery efficiency of 71.0%.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Farrah S. R., Goyal S. M., Gerba C. P., Conklin R. H., Wallis C., Melnick J. L., DuPont H. L. A simple method for concentration of enteroviruses and rotaviruses from cell culture harvests using membrane filters. Intervirology. 1978;9(1):56–59. doi: 10.1159/000148921. [DOI] [PubMed] [Google Scholar]
- Francis T., Jr, Salk J. E. A SIMPLIFIED PROCEDURE FOR THE CONCENTRATION AND PURIFICATION OF INFLUENZA VIRUS. Science. 1942 Nov 27;96(2500):499–500. doi: 10.1126/science.96.2500.499. [DOI] [PubMed] [Google Scholar]
- Gerba C. P., Farrah S. R., Goyal S. M., Wallis C., Melnick J. L. Concentration of enteroviruses from large volumes of tap water, treated sewage, and seawater. Appl Environ Microbiol. 1978 Mar;35(3):540–548. doi: 10.1128/aem.35.3.540-548.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Henderson M., Wallis C., Melnick J. L. Acid sensitivity of the influenza virus hemagglutinin. Appl Microbiol. 1973 Apr;25(4):685–687. doi: 10.1128/am.25.4.685-687.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Heyward J. T., Klimas R. A., Stapp M. D., Obijeski J. F. The rapid concentration and purification of influenza virus from allantoic fluid. Arch Virol. 1977;55(1-2):107–119. doi: 10.1007/BF01314484. [DOI] [PubMed] [Google Scholar]
- MILLER H. K., SCHLESINGER R. W. Differentiation and purification of influenza viruses by adsorption on aluminum phosphate. J Immunol. 1955 Aug;75(2):155–160. [PubMed] [Google Scholar]
- NEWTON N., BEVIS R. E. Purification of animal viruses with Zn(OH)2. Virology. 1959 Jul;8(3):344–351. doi: 10.1016/0042-6822(59)90034-0. [DOI] [PubMed] [Google Scholar]
- Reimer C. B., Baker R. S., Van Frank R. M., Newlin T. E., Cline G. B., Anderson N. G. Purification of large quantities of influenza virus by density gradient centrifugation. J Virol. 1967 Dec;1(6):1207–1216. doi: 10.1128/jvi.1.6.1207-1216.1967. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Salk J. E. THE IMMUNIZING EFFECT OF CALCIUM PHOSPHATE ADSORBED INFLUENZA VIRUS. Science. 1945 Feb 2;101(2614):122–124. doi: 10.1126/science.101.2614.122. [DOI] [PubMed] [Google Scholar]
- Sobsey M. D., Jones B. L. Concentration of poliovirus from tap water using positively charged microporous filters. Appl Environ Microbiol. 1979 Mar;37(3):588–595. doi: 10.1128/aem.37.3.588-595.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- VEERARAGHAVAN N., SREEVALSAN T. Evaluation of some methods of concentration and purification of influenza virus. Bull World Health Organ. 1961;24:695–702. [PMC free article] [PubMed] [Google Scholar]
- Wallis C., Melnick J. L. Concentration of enteroviruses on membrane filters. J Virol. 1967 Jun;1(3):472–477. doi: 10.1128/jvi.1.3.472-477.1967. [DOI] [PMC free article] [PubMed] [Google Scholar]
