Abstract
The efficiency of concentrating poliovirus 1 from distilled water samples was determined by using a recirculating-flow molecular filtration system. The most efficient recoveries were achieved against members with a 10,000 nominal molecular weight limit pretreated with flocculated beef extract. This procedure yielded a mean virus recovery of 67%.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Berg G., Dahling D. R., Berman D. Recovery of small quantities of viruses from clean waters on cellulose nitrate membrane filters. Appl Microbiol. 1971 Oct;22(4):608–614. doi: 10.1128/am.22.4.608-614.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dahling D. R., Berg G., Berman D. BGM, a continuous cell line more sensitive than primary rhesus and African green kidney cells for the recovery of viruses from water. Health Lab Sci. 1974 Oct;11(4):275–282. [PubMed] [Google Scholar]
- Farrah S. R., Goyal S. M., Gerba C. P., Wallis C., Melnick J. L. Concentration of poliovirus from tap water onto membrane filters with aluminum chloride at ambient pH levels. Appl Environ Microbiol. 1978 Mar;35(3):624–626. doi: 10.1128/aem.35.3.624-626.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gangemi J. D., Connell E. V., Mahlandt B. G., Eddy G. A. Arenavirus concentration by molecular filtration. Appl Environ Microbiol. 1977 Sep;34(3):330–332. doi: 10.1128/aem.34.3.330-332.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Katzenelson E., Fattal B., Hostovesky T. Organic flocculation: an efficient second-step concentration method for the detection of viruses in tap water. Appl Environ Microbiol. 1976 Oct;32(4):638–639. doi: 10.1128/aem.32.4.638-639.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mathes L. E., Yohn D. S., Olsen R. G. Purification of infectious feline leukemia virus from large volumes of tissue culture fluids. J Clin Microbiol. 1977 Mar;5(3):372–374. doi: 10.1128/jcm.5.3.372-374.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sobsey M. D., Jones B. L. Concentration of poliovirus from tap water using positively charged microporous filters. Appl Environ Microbiol. 1979 Mar;37(3):588–595. doi: 10.1128/aem.37.3.588-595.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sobsey M. D., Wallis C., Henderson M., Melnick J. L. Concentration of enteroviruses from large volumes of water. Appl Microbiol. 1973 Oct;26(4):529–534. doi: 10.1128/am.26.4.529-534.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wallis C., Henderson M., Melnick J. L. Enterovirus concentration on cellulose membranes. Appl Microbiol. 1972 Mar;23(3):476–480. doi: 10.1128/am.23.3.476-480.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
