Skip to main content
Applied Physics Letters logoLink to Applied Physics Letters
. 2010 Jul 20;97(3):032902. doi: 10.1063/1.3466906

Elastic, dielectric, and piezoelectric constants of Pb(In1∕2Nb1∕2)O3–Pb(Mg1∕3Nb2∕3)O3–PbTiO3 single crystal poled along [011]c

Enwei Sun 1,2, Shujun Zhang 2, Jun Luo 3, Thomas R Shrout 2, Wenwu Cao 1,2,a)
PMCID: PMC2921416  PMID: 20714370

Abstract

Ternary single crystals xPb(In1∕2Nb1∕2)O3–(1−xy)Pb(Mg1∕3Nb2∕3)O3yPbTiO3 (PIN-PMN-PT) poled along [011]c showed remarkable electromechanical properties. We report complete sets of elastic, dielectric, and piezoelectric constants of PIN-PMN-28%PT and PIN-PMN-32%PT, measured by using combined resonance and ultrasonic methods. The electromechanical coupling coefficients k15, k32, and k33 can reach 0.95, 0.90, and 0.92, and the piezoelectric strain coefficients d15, d32, and d33 are as high as 3354 pC∕N, −1781 pC∕N, and 1363 pC∕N, respectively. These full matrix data sets provide the base for fundamental studies on domain engineering phenomena as well as urgently needed input data for the design of electromechanical devices using [011]c poled PIN-PMN-PT single crystals.


[011]c-poled relaxor-based ferroelectric single crystals (1−x)Pb(Zn1∕3Nb2∕3)O3xPbTiO3 (PZN–xPT) and (1−x)Pb(Mg1∕3Nb2∕3)O3xPbTiO3 (PMN–xPT) with compositions near the morphotropic phase boundary (MPB) exhibit ultrahigh transverse piezoelectric properties, which provides the base for much better transverse mode piezoelectric devices.1, 2, 3, 4, 5, 6, 7 However, the coercive field EC (∼2.5 kV∕cm) of these binary crystals is too low for high-field driven devices. In addition, their relatively low Curie point Tc (∼130–170 °C) and low rhombohedral–tetragonal phase transition temperature TR–T (∼75–95 °C) cause poor temperature stability and restrict device operating temperatures.

It was demonstrated that the ternary xPb (In1∕2Nb1∕2) O3– (1−xy)Pb (Mg1∕3Nb2∕3) O3yPbTiO3 (PIN-PMN-PT) single crystal system has about 30 °C higher rhombohedral–tetragonal phase transition temperature than that of PMN-PT single crystals.8, 9, 10 The coercive field of this ternary single crystal has increased more than twice.11, 12 More importantly, this PIN-PMN-PT single crystal system has just as excellent piezoelectric properties as PMN-PT and PZN-PT single crystals. Recently, Liu et al.13, 14 have measured the complete sets of material constants for [001]c- and [111]c-poled rhombohedral PIN-PMN-PT single crystals with MPB composition using combined resonance and ultrasonic methods.

The PIN-PMN-PT ternary relaxor based ferroelectric single crystal has perovskite cubic structure above Tc, becomes tetragonal below Tc and transforms to rhombohedral below TR–T with 3m point group symmetry. When the crystal is being poled along [011]c direction, the domain pattern forms orthorhombic mm2 symmetry.15, 16 Following the convention, we take the [011]c pseudocubic direction as the Z axis, the [01¯1]c and [100]c as the X and Y axes, respectively. Based on such a coordinate choice, we report here two complete sets of material constants for PIN-PMN-28%PT and PIN-PMN-32%PT single crystals poled along [011]c.

The PIN-PMN-PT single crystals used in our work were grown by the modified Bridgman method. The nominal composition of xPIN–(1−xy)PMN–yPT crystals obtained are x∼0.25–0.35 and y∼0.30–0.32 but the composition along the growth direction varies due to the segregation of titanium in the crystal. Our crystal samples were cut from the bottom and middle part of the as-grown crystal boule, and the corresponding PT contents are 0.28 and 0.32, respectively.

All samples were oriented using the Laue x-ray machine with an accuracy of ±0.5°. Each sample was cut and polished into a parallelepiped with three pairs of parallel surfaces along [01¯1]c, [100]c, and [011]c, respectively. Then, the samples were sputtered with gold electrodes on the pair of [011]c surfaces, and poled with a field of 10–15 kV∕cm at room temperature. Because the [011]c poled multidomain PIN-PMN-PT single crystals have macroscopic orthorhombic mm2 symmetry, there are total 17 independent material constants to be determined for each composition; nine elastic, five piezoelectric, and three dielectric constants.

It is nearly impossible to pole samples of different geometries to the same degree because the domain pattern formed depends on the geometry. Therefore, it is often very difficult to get self-consistency full matrix data by using the resonance method described in related textbooks. This is the main reason why some published data on [011]c poled PMN-PT single crystals measured by using the resonance technique are lack of self-consistency.17 Therefore, we used combined resonance and ultrasonic methods together with capacitance and d33 meter to obtain the maximum number of combinations from the least number of samples.18

For resonance measurements, the dimensions and geometries of samples used were specified by the IEEE standards on piezoelectricity.19 The resonance and antiresonance frequencies were obtained by an HP 4194 A impedance-phase gain analyzer. In ultrasonic measurements, a 5.0×5.0×5.0 mm3 cube was used and the orientations are [01¯1]c, [100]c, and [011]c. A 15 MHz longitudinal wave transducer (Ultran Laboratories, Inc.) and a 20 MHz shear wave transducer (Panametrics Com.) were used for the ultrasonic pulse-echo measurements. The transducers were excited by a 200 MHz pulser∕receiver (Panametrics Com.) and the time of flight between echoes was measured using a Tektronix 460 A digital oscilloscope. The phase velocities of the longitudinal and shear waves were measured along the three pure mode directions, i.e., [01¯1]c, [100]c, and [011]c. We can obtain eight elastic stiffness constants: c11E, c22E, c33D, c44E, c44D, c55E, c55D, and c66E based on the Christoffel wave equations from this one sample alone.

From the measured resonance and antiresonance frequencies, we can calculate the corresponding piezoelectric strain coefficients d31, d32, and d33, the elastic compliance constants s11E, s22E, s33E, and s33D, the elastic stiffness constants c33D and c33E, and electromechanical coupling coefficients k31, k32, k33, and kt. The free and clamped dielectric constants ε11T, ε22T, ε33T, ε11S, ε22S, and ε33S were determined from the low (1 kHz) and high frequency (2fa) capacitance measurements. Overall, we obtained 27 independent measurements for the 17 independent coefficients. A program was developed to extract a reliable self-consistent matrix data set based on error analysis.

The measured and derived elastic, piezoelectric and dielectric constants of the PIN-PMN-28%PT and PIN-PMN-32%PT single crystals poled along [011]c are given in Table 1. Material constants marked with a star (*) were determined directly by the resonance or ultrasonic measurements while others were derived values. Compared with [001]c poled PIN-PMN-PT single crystal, the main advantage of the [011]c poled crystal is its super large shear piezoelectric coefficient d15 (3354 pC∕N for PIN-PMN-32%PT), which is more than an order of magnitude larger than the d15 [232 pC∕N for PIN-PMN-33%PT (Ref. 13)] of [001]c poled single crystal.

Table 1.

Measured and derived material constants of PIN-PMN-28%PT and PIN-PMN-32%PT multidomain single crystals poled along [011]c. [Directly measured constants are denoted by star (*).]

  Elastic stiffness constants: cijE and cijD (1010 N∕m2)
c11E* c12E c13E c22E* c23E c33E c44E* c55E* c66E*      
28%PT 19.96 12.51 7.19 13.54 11.89 15.36 6.49 0.76 5.33      
32%PT 21.45 15.01 8.01 17.37 14.10 15.26 6.37 0.48 4.56      
                         
  c11D c12D c13D c22D c23D c33D* c44D* c55D* c66D      
28%PT 20.19 12.10 8.26 14.25 10.02 20.21 7.15 4.56 5.33      
32%PT 21.50 14.86 8.46 17.94 12.39 20.35 7.30 4.59 4.56      
                         
  Elastic compliance constants: sijE and sijD (10−12 m2∕N)
s11E* s12E s13E s22E* s23E s33E s44E s55E s66E      
28%PT 18.27 −29.36 14.05 69.97 −40.37 31.23 15.41 131.58 18.76      
32%PT 25.53 −45.13 27.87 101.45 −70.31 56.84 15.70 208.33 21.93      
                         
  s11D s12D s13D s22D s23D s33D* s44D s55D s66D      
28%PT 10.07 −8.75 0.11 18.18 −5.33 7.59 13.99 21.93 18.76      
32%PT 11.21 −10.84 1.63 19.37 −7.50 8.79 13.70 21.79 21.93      
                         
  Piezoelectric coefficients: eiλ(C∕m2), diλ(10−12 C∕N), giλ(10−3 Vm∕N), and hiλ(108 V∕m)
e15 e24 e31 e32 e33 d15 d24 d31* d32* d33*    
28%PT 16.74 7.39 3.43 −6.00 15.74 2203 114 460 −1156 782    
32%PT 16.10 10.32 1.44 −5.50 16.47 3354 162 744 −1781 1363    
                         
  g15 g24 g31 g32 g33 h15 h24 h31 h32 h33    
28%PT 49.79 12.51 17.80 −44.73 30.26 22.71 8.94 6.79 −11.89 31.20    
32%PT 55.63 12.34 19.28 −46.15 35.32 25.51 9.01 2.72 −10.41 31.17    
                         
  Dielectric constants: εij0) and β(10−4∕ε0)
ε11S* ε22S* ε33S* ε11T* ε22T* ε33T* β11S β22S β33S β11T β22T β33T
28%PT 833 935 570 5000 1030 2920 12.01 10.70 17.54 2.00 9.71 3.43
32%PT 713 1294 597 6814 1483 4361 14.03 7.73 16.75 1.47 6.74 2.29
                         
  Electromechanical coupling factors kij and density
k15 k24 k31* k32* k33* kt* Density (kg∕m3)          
28%PT 0.91 0.30 0.67 0.86 0.87 0.49 8102          
32%PT 0.95 0.36 0.75 0.90 0.92 0.50 8185          

Some material constants for different relaxor-based ferroelectric single crystals poled along [011]c are listed in Table 2 for comparison. We found that the electromechanical coupling coefficients and the piezoelectric strain coefficients of PIN-PMN-32%PT single crystal are comparable to that of PMN-30%PT, much better than PMN-28%PT and PMN-29%PT. The dielectric constants of PIN-PMN-PT system are lower than those of PMN-PT crystal system, making it a better candidate for ultrahigh frequency medical imaging transducers. The coercive field of PIN-PMN-28%PT and PIN-PMN-32%PT is around 5.5 kV∕cm, which is more than twice of the value of binary PMN-31%PT (∼2.6 kV∕cm). Figure 1 shows the temperature dependence of the dielectric constant ε33T. It can be seen that the Curie temperatures of the PIN-PMN-28%PT and PIN-PMN-32%PT are 165 °C and 192 °C, respectively, which is more than 20 °C higher than that of PMN-31%PT (143 °C). Both the rhombohedral–orthorhombic and orthorhombic–tetragonal phase transition temperatures TR–O and TO–T of PIN-PMN-32%PT (93 °C and 118 °C) are more than 15 °C higher than that of PMN-31%PT (77 °C and 100 °C). For PIN-PMN-28%PT, there is only rhombohedral–tetragonal phase transition, which occurs at TR−T=120 °C.

Table 2.

Comparison of some important material constants for different relaxor-based ferroelectric single crystals poled along [011]c.

Single crystals d15 (pC∕N) d32 (pC∕N) d33 (pC∕N) k15 k32 k33 ε11Tε0 ε22Tε0 ε33Tε0
PMN-28%PTa 2816 −1761 1766 0.90 0.89 0.91 7466 4713 6366
PMN-29%PTb 1188 −1883 1020 0.83 0.94 0.78 3564 1127 4033
PMN-30%PTa 3262 −2116 1916 0.95 0.94 0.92 8783 5233 6966
PIN-PMN-28%PTc 2203 −1156 782 0.91 0.86 0.87 5000 1030 2920
PIN-PMN-32%PTc 3354 −1781 1363 0.95 0.90 0.92 6814 1483 4361
a

See Reference 6.

b

See Reference 7.

c

This work.

Figure 1.

Figure 1

Dielectric constant ε33Tε0 as a function of temperature for PMN-31%PT, PIN-PMN-28%PT, and PIN-PMN-32%PT single crystals measured in the poling direction [011]c.

In summary, by using combined resonance and ultrasonic methods, we have measured the elastic, dielectric, and piezoelectric constants of relaxor-based ferroelectric PIN-PMN-28%PT and PIN-PMN-32%PT ternary multidomain single crystals poled along [011]c. Due to higher phase transition temperature and much larger field endurance, [011]c poled PIN-PMN-PT single crystals are much better candidates than PMN-PT and PZN-PT single crystals for shear and transverse piezoelectric devices. The two complete sets of material constants for two compositions of [011]c-poled rhombohedral PIN-PMN-PT domain engineered single crystals can be used to perform fundamental theoretical analysis on domain engineering phenomena as well as being the input for finite element packages to design and optimize practical electromechanical device, such as transducers, sensors and actuators.

Acknowledgments

This research was supported by the NIH under Grant No. P41-EB21820 and ONR under Grant Nos. N00014-09-01-0456 and N00014-07-C-0858, and the Chinese Ministry of Education for the oversea joint-training Ph.D. student program.

References

  1. Liu T. and Lynch C. S., Acta Mater. 51, 407 (2003). 10.1016/S1359-6454(02)00422-6 [DOI] [Google Scholar]
  2. Zhang R., Jiang B., and Cao W., J. Phys. Chem. Solids 65, 1083 (2004). 10.1016/j.jpcs.2003.10.072 [DOI] [Google Scholar]
  3. Zhang R., Jiang B., Jiang W., and Cao W., Appl. Phys. Lett. 89, 242908 (2006). 10.1063/1.2404613 [DOI] [Google Scholar]
  4. Rajan K. K., Shanthi M., Chang W. S., Jin J., and Lim L. C., Sens. Actuators, A 133, 110 (2007). 10.1016/j.sna.2006.03.036 [DOI] [Google Scholar]
  5. Rajan K. K., Jin J., Chang W. S., and Lim L. C., Jpn. J. Appl. Phys., Part 1 46, 681 (2007). 10.1143/JJAP.46.681 [DOI] [Google Scholar]
  6. Shanthi M., Lim L. C., Rajan K. K., and Jin J., Appl. Phys. Lett. 92, 142906 (2008). 10.1063/1.2907702 [DOI] [Google Scholar]
  7. Wang F., Luo L., Zhou D., Zhao X., and Luo H., Appl. Phys. Lett. 90, 212903 (2007). 10.1063/1.2743393 [DOI] [Google Scholar]
  8. Hosono Y., Yamashita Y. H, Sakamoto, and Ichinose N., Jpn. J. Appl. Phys., Part 1 42, 5681 (2003). 10.1143/JJAP.42.5681 [DOI] [Google Scholar]
  9. Hosono Y., Yamashita Y., Hirayama K., and Ichinose N., Jpn. J. Appl. Phys., Part 1 44, 7037 (2005). 10.1143/JJAP.44.7037 [DOI] [Google Scholar]
  10. Zhang S., Luo J., Hackenberger W., and Shrout T. R., J. Appl. Phys. 104, 064106 (2008). 10.1063/1.2978333 [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Tian J., Han P., Huang X., Pan H., J. F.CarrollIII, and Payne D. A., Appl. Phys. Lett. 91, 222903 (2007). 10.1063/1.2817743 [DOI] [Google Scholar]
  12. Zhang S., Luo J., Hackenberger W., Sherlock N. P., R. J.Meyer, Jr., and Shrout T. R., J. Appl. Phys. 105, 104506 (2009). 10.1063/1.3131622 [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Liu X., Zhang S., Luo J., Shrout T. R., and Cao W., J. Appl. Phys. 106, 074112 (2009). 10.1063/1.3243169 [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Liu X., Zhang S., Luo J., Shrout T. R., and Cao W., Appl. Phys. Lett. 96, 012907 (2010). 10.1063/1.3275803 [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Viehland D., Amin A., and Li J. F., Appl. Phys. Lett. 79, 1006 (2001). 10.1063/1.1392307 [DOI] [Google Scholar]
  16. Lu Y., Jeong D. -Y., Cheng Z. -Y., Zhang Q. M., Luo H., Yin Z., and Viehland D., Appl. Phys. Lett. 78, 3109 (2001). 10.1063/1.1372360 [DOI] [Google Scholar]
  17. Topolov V. Yu., Appl. Phys. Lett. 96, 196101 (2010). 10.1063/1.3429603 [DOI] [Google Scholar]
  18. Zhang R., Jiang B., Cao W., and Amin A., J. Mater. Sci. Lett. 21, 1877 (2002). 10.1023/A:1021573431692 [DOI] [Google Scholar]
  19. ANSI∕IEEE Std. 176-1987, IEEE Standard on Piezoelectricity (IEEE, New York, 1987), p. 176.

Articles from Applied Physics Letters are provided here courtesy of American Institute of Physics

RESOURCES